IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Similar documents
Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

RJ Series Slim Power Relays

Relays & Sockets. General-purpose electromechanical relays and sockets

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

RU Series. Full featured universal miniature relays. Designed with environment taken into consideration.

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

20 Series Power Relays

RU Series Universal Relays

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Timers GE1A. GE1A Series ON Delay Timers Single Function

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Model Number Structure

OMRON MK-I / -S RELAY

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

6mm Interface Relays RV8 Series

RF1V Force Guided Relays / SF1V Relay Sockets

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Safety Monitoring Relays

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Technical Information General Purpose Relays

Compact Relay Family with Forcibly Guided Contacts

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

SPST-NO SPDT DPST-NO DPDT

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Transistor drive 2c/4c 5A slim power relays

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

UNIQUELY DESIGNED RELAY FEATURES

Relays. Switching & Controls. Selection Guide

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Relays. Switching & Controls.

SPST-NO SPDT DPST-NO DPDT

Solid-state Twin Timer

Palm-sized, 16-channel Relay Terminals

3. Contact Form A: SPST-NO

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Slim compact safety relay

Relays. Switching & Controls. Selection Guide

General-purpose Relay

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Relays & Sockets. Switching & Controls.

General-purpose Relay

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay


PARM-SIZED, 16-CHANNEL RELAY TERMINALS

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Suitable for lighting and motor load, 1 Form A 50A latching relays

Compliant with European standards 1a/1c 6A Slim power relays

1a/1c/2a/2c/5A/10A power relays for power supply

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

1a 16A power relay for micro wave oven

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects

High Capacity of Max. 1,000 V DC Cut-off Possible

G2RL-1A G2RL-1 G2RL-2A G2RL-2

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

RT-3 UNIT RELAY 4-POINT TERMINAL

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Relays & Sockets. Switching & Controls.

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Technical Information General Purpose Relays. Glossary. Maximum switching power [W(VA)] Switching current (A) Switching voltage (V) Contact Symbols

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

SLIM COMPACT SAFETY RELAY

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Emitting and receiving element pitch: 10 mm in

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

1a/1c/2a/2c/5A/10A power relays for power supply

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor

TV-15, 30 AMP (1 Form A) Power Relay

RT-3 UNIT RELAY 4-POINT TERMINAL

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

MINIATURE RELAY FOR WIDER APPLICATIONS

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Model Number Structure

38 Series - Relay interface modules A. Features /


COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

Transcription:

IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact reliability with bifurcated contacts (minimum applicable load: V DC, 00µA) The smallest width for 2-pole/bifurcated contacts relay Non-polarized green LED indicator available (except for simple type) IDEC s unique light-guide structure enables an RJ relay to be identified by the illuminating LED Diode, reverse polarity diode, and RC circuits are available Peak inverse voltage is 000V UL recognized, CSA certified, VDE approved, CE marked Applicable Standards UL Standards Mark File No. or Organization CSA C22.2 No.4 UL Recognized File No. E55996 CSA File No. LR3544 IDEC's unique light-guide structure EN- VDE No. 055 EU Low Directive Lightguide Green LED indicator compliant with IEC requirements. Relays Bifurcated Contacts Type Part No. 2-pole (bifurcated contacts DPDT) Coil Code Standard (with LED indicator) RJ22S-CL-* A2, A24, A20, Simple (without LED indicator) RJ22S-C-* A2, D5, D2, D24, D00 With diode (with LED indicator) With diode (without LED indicator) Contact Ratings Allowable Contact RJ22S-CLD-* RJ22S-CD-* Rated Load Resistive Load Inductive Load Resistive Load 2VA AC 30W DC 00VA AC 5W DC D5, D2, D24, D4, D00 Inductive Load cosø=0.4 L/R=7ms 2V AC A 0.4A 30V DC A 0.5A Allowable Switching Current A Coil Code A2 A24 A20 A2 D5 D2 D24 D4 D00 Code Allowable Switching 2V AC 25V DC 2V AC 24V AC 20V AC 2V AC 5V DC 2V DC 24V DC 4V DC 00-0V DC Minimum Applicable Load (Note) V DC 00μA (reference value) Note: Measured at operating frequency of 20 operations per minute (failure rate level P, reference value) High contact reliability with bifurcated contacts Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) Ratings UL Ratings CSA Ratings VDE Ratings Resistive General Use Resistive Inductive General Use Resistive NO NC NO NC NO NC NO NC NO NC NO NC 2V AC A A A A A A 30V DC A A A A A A A A Coil Ratings Rated (V) Coil Code Without LED Indicator Rated Current (ma) ±5% (at 20 C) Coil Resistance (Ω) ±0% (at 20 C) Hz Hz Hz Hz With LED Indicator Rated Current (ma) ±5%, (at 20 C) Coil Resistance (Ω) ±0% (at 20 C) Operating Characteristics (against rated values at 20 C) Pickup (initial value) Dropout (initial value) Maximum Continuous Applied (Note) 2V A2 7.3 75.0 62.5 9. 7. 62.5 AC 24V A24 43.9 37.5 243 47.5 4. 243 0% 30% % / Hz 20V A20. 7.5 6,0.7 7.4 6,0 maximum minimum 2V A2 4.3 3.7 25,5 4.3 3.7 25,5 5V D5 06 47.2 0 47.2 2V D2 44.2 27 4.0 27 % 0% DC 24V D24 22.,00 25.7,00 maximum minimum 4V D4.0 4,3 0.7 4,3 00-0V D00 5.3-5., 5.2-5.7, % Note: Maximum continuous applied voltage is the maximum voltage that can be applied to relay coils. Specifications Relay Number of Poles Contact Configuration Contact Material Degree of Protection Contact Resistance (initial value) Operating Time (at 20 C) Release Time (at 20 C) Impulse Withstand Insulation Resistance Between contact and coil Dielectric Strength Vibration Resistance Shock Resistance Electrical Life Mechanical Life Operating Temperature (00% rated voltage) Operating Humidity Storage Temperature Storage Humidity Weight (approx.) RJ22S 2-pole DPDT (bifurcated contacts) AgNi (gold clad) IP mω maximum (measured using 5V DC, A voltage drop method) 5ms maximum (at the rated coil voltage, excluding contact bounce time) With diode or RC: 20 ms maximum 0ms maximum (at the rated coil voltage, excluding contact bounce time) With diode or RC: 20 ms maximum 0,000V AC (between contact and coil) 00MΩ minimum (0V DC megger) 5,000V AC, minute Between contacts of the same pole,000v AC, minute Between contacts of the different poles 3,000V AC, minute Operating Extremes 0 to 55Hz, amplitude 0.75mm Damage Limits 0 to 55Hz, amplitude 0.75mm Operating Extremes NO contact: 200 m/s 2, NC contact: 00 m/s 2 Damage Limits,000 m/s 2 AC load: 00,000 operations minimum (operating frequency,00 per hour) DC load: 200,000 operations minimum (operating frequency,00 per hour) AC load: 0 million operations minimum (operating frequency,000 operations per hour) DC load: 20 million operations minimum (operating frequency,000 operations per hour) to C (no freezing) 5 to 5%RH (no condensation) to 5 C (no freezing) 5 to 5%RH (no condensation) 9g Applicable Sockets Style Standard Screw Terminal Finger-safe Screw Terminal PC Board Terminal Consumption Approx..VA (Hz) 0.9 to.2va (Hz) % Approx. 0.53 to 4W Part No. SJ2S-05B SJ2S-07L SJ2S-6 Standard Screw Terminals Finger-safe Screw Terminals (IP20) PC Board Terminals Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) Dimensions (mm) When mounted in a socket 6.0 27.0 55.7mm 55.7mm ø.2 3 elongated hole 0.5 0.5 2.6 3. 4 3 2 5 6 7 7mm 7mm 2.7 2.6 5.5mm 5.5mm 2. Internal Connection (bottom view) RJ22S-CL-* Standard (with LED indicator) (A) 2(2) 3() 4(4) (A) 2(2) 3() 4(4) RJ22S-CLD-* With diode (with LED indicator) (A) 2(2) 3() 4(4) (A) 2(2) 3() 4(4) 7(22) 6(2) 5(24) 24V AC/DC or less Over 24V AC/DC 7(22) 6(2) 5(24) 7(22) 6(2) 5(24) 7(22) 6(2) 5(24) 24V AC/DC or less Over 24V AC/DC RJ22S-C-* Simple RJ22S-CD-* With diode (A) 2(2) 3() 4(4) (A) 2(2) 3() 4(4) 7(22) 6(2) 5(24) 7(22) 6(2) 5(24) Operating Temperature and Coil Temperature Rise 30 20 0 00 0 30 20 0 0 AC Coil ( Hz) AC Coil ( Hz) DC Coil 30 30 20 20 0 0 00 00 0 0 Load current A x 2 poles 30 Load current A x 2 poles 30 No load current 20 No load current 20 Load current A x 2 poles 0 0 No load current 0 20 30 0 0 20 30 The slanted dashed line indicates the allowable temperature rise for the coil at different ambient temperatures. The above temperature rise curves show the characteristics when 00% of the rated coil voltage is applied. 0 0 20 30 Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay PC Board Terminal (Bifurcated Contacts) High contact reliability with bifurcated contacts (minimum applicable load: V DC, 00 µa) DPDT, DPST-NO contacts are available. The smallest width for 2-pole/bifurcated contacts relay IDEC s unique spring return mechanism ensures long life. Flux-tight structure Applicable Standards Standards Mark File No. or Organization UL UL Recognition File No. E55996 CSA C22.2 No.4 EN- CSA File No. LR3544 VDE No. 055 EU Low Directive DPST-NO contact (bifurcated) DPDT contact (bifurcated) Relays Bifurcated Contacts Type Contact DPDT Plain DPST-NO Part No. (Ordering Part No.) RJ22V-C-* RJ22V-A-* 2-pole (bifurcated contacts DPDT) Coil Code A2, A24, A20, A2, D5, D2, D24, D4, D00 Coil Code Code A2 2V AC A24 24V AC A20 20V AC A2 2V AC D5 5V DC D2 2V DC D24 24V DC D4 4V DC D00 00-0V DC Contact Ratings Allowable Contact Rated Load Allowable Switching Inductive Load Resistive Load Inductive Load Resistive Load cosø=0.4 L/R=7ms Current Allowable Switching Minimum Applicable Load (Note) 2VA AC 30W DC 00VA AC 5W DC 2V AC A 0.4A 30V DC A 0.5A A 2V AC 25V DC V DC 00μA (reference value) Note: Measured at operating frequency of 20 operations per minute (failure rate level P, reference value) Ratings UL ratings CSA Ratings VDE Ratings Resistive General Use Resistive Inductive General Use Resistive NO NC NO NC NO NC NO NC NO NC NO NC 2V AC A A A A A A 30V DC A A A A A A A A Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay PC Board Terminal (Bifurcated Contacts) Coil Ratings Rated (V) Coil Code Rated Current (ma) ±5% (at 20 C) Hz Hz Coil Resistance (Ω) ±0% (at 20 C) 2V A2 7.3 75.0 62.5 AC / Hz 24V 20V A24 A20 43.9. 37.5 7.5 243 6,0 2V A2 4.3 3.7 25,5 5V D5 06 47.2 2V D2 44.2 27 DC 24V D24 22.,00 4V D4.0 4,3 00-0V D00 5.3-5., Note: Maximum continuous applied voltage is the maximum voltage that can be applied to relay coils. Pickup (initial value) 0% maximum % maximum Operating Characteristics (against rated values at 20 C) Dropout (initial value) 30% minimum 0% minimum Maximum Continuous Applied (Note) % % % Consumption Approx..VA (Hz) 0.9 to.2va (Hz) Approx. 0.53 to 4W Specifications Relay RJ22V Number of Poles 2-pole Contact Configuration DPDT (bifurcated), DPST-NO (bifurcated) Contact Material AgNi (gold clad) Degree of Protection Flux-tight structure Contact Resistance (initial value) mω maximum (measured using 5V DC, A voltage drop method) Operating Time (at 20 C) 5 ms maximum (at the rated coil voltage, excluding contact bounce time) Release Time (at 20 C) 0 ms maximum (at the rated coil voltage, excluding contact bounce time) Insulation Resistance 00 MΩ minimum (0V DC megger) Impulse Withstand 0,000V AC (between contact and coil) Between contact and coil 5,000V AC, minute Dielectric Strength Between contacts of the same pole,000v AC, minute Between contacts of the different poles 3,000V AC, minute Vibration Operating Extremes 0 to 55 Hz, amplitude 0.75 mm Resistance Damage Limits 0 to 55 Hz, amplitude 0.75 mm Shock Operating Extremes NO contact: 200 m/s 2, NC contact: 00 m/s 2 Resistance Damage Limits,000 m/s 2 Electrical Life AC load: 00,000 operations minimum (operating frequency,00 per hour) DC load: 200,000 operations minimum (operating frequency,00 per hour) Mechanical Life AC load: 0 million operations minimum (operating frequency,000 operations per hour) DC load: 20 million operations minimum (operating frequency,000 operations per hour) Operating Temperature (00% rated voltage) to C (no freezing) Operating Humidity 5 to 5%RH (no condensation) Storage Temperature to 5 C (no freezing) Storage Humidity 5 to 5%RH (no condensation) Weight (approx.) DPDT: 7g, DPST-NO: 6g Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay PC Board Terminal (Bifurcated Contacts) Dimensions (mm) RJ22V-C-* RJ22V-A-* 25.5 max. (25.3) 4.0 0.3 25.5 max. (25.3) 0.4 29 max. (2.) 3 max. (2.7). 4.0 0.3 0.4 29 max. (2.) 3 max. (2.7). Mounting Hole Layout When mounted in a socket RJ22V-C-* (2.6) -ø.3 holes 5.0 5.0 7.5 RJ22V-A-* (2.6) 6-ø.3 holes 7.5 55.7mm 55.7mm (.9) 20.0 (.9) 20.0 5.0 7mm 7mm Internal Circuit Diagram (Bottom View) RJ22V-C-* (A) 2(2) 3() 4(4) RJ22V-A-* (A) 3() 4(4) 5.5mm 5.5mm 7(22) 6(2) 5(24) 6(2) 5(24) Operating Temperature and Coil Temperature Rise 30 20 0 00 0 30 20 0 0 AC Coil ( Hz) AC Coil ( Hz) DC Coil 30 30 20 20 0 0 00 00 0 0 Load current A x 2 poles 30 Load current A x 2 poles 30 No load current 20 No load current 20 0 0 0 20 30 0 0 20 30 0 Load current A x 2 poles No load current 0 20 30 The slanted dashed line indicates the allowable temperature rise for the coil at different ambient temperatures. The above temperature rise curves show the characteristics when 00% of the rated coil voltage is applied. Safety Precautions Turn off the power to the RJ relay prior to installation, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shock or fire. Observe the specifications and rated values, otherwise electrical shock or fire may occur. Use wires of the proper size to meet the voltage and current requirements. Tighten terminal screws to a proper tightening torque. Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) Instructions. Driving Circuit for Relays. To make sure of correct relay operation, apply rated voltage to the relay coil. 2. Input voltage for DC coil: Complete DC voltage is best for stable operation of the coil power. When using a power supply containing a ripple voltage, suppress the ripple factor within 5%. When power is supplied through a rectification circuit, relay operating characteristics, such as pickup voltage and dropout voltage, depend on the ripple factor. Connect a smoothing capacitor for better operating characteristics as shown below. Smoothing Capacitor R Relay Pulsation Emin Emax Emean DC Emax Emin Ripple Factor (%) 00% Emean Emax = Maximum of pulsating current Emin = Minimum of pulsating current Emean= DC mean value 3. Operating the relay in sync with an AC load: If the relay operates in sync with the AC power voltage of the load, the relay life may be reduced. If this is the case, select a relay with the required load reliability. Or, make the relay turn on and off irrespective of the AC power phase or near the point where the AC phase crosses zero voltage. TE R Load Vin EAC Vin 4. Leakage current while relay is off: EAC Incorrect R TE Correct R lo When driving an element at the same time as the relay is operating, special consideration is needed when designing the circuit. As shown in the incorrect circuit example above, leakage current (Io) flows through the relay coil while the relay is off. Leakage current causes coil release failure or adversely affects the vibration and shock resistance. Design a circuit as shown in the correct example. 5. Surge suppression for transistor driving circuits: When the relay coil is turned off, a high-voltage pulse is generated. Be sure to connect a diode to suppress the counter electromotive force. Then, the coil release time becomes slightly longer. To shorten the coil release time, connect a Zener diode between the collector and emitter of the controlling transistor. Select a Zener diode with a Zener voltage slightly higher than the power voltage. Counter emf suppressing diode R Relay 2. Protection for Relay Contacts. The contact ratings show maximum values. Make sure that these values are not exceeded. When an inrush current flows through the load, the contact may become welded. If this is the case, connect a contact protection circuit, such as a current limiting resistor. 2. Contact protection circuit: When switching an inductive load, arcing causes carbides to form on the contacts, resulting in increased contact resistance. In consideration of contact reliability, contact life, and noise suppression, use of a surge absorbing circuit is recommended. Note that the release time of the load becomes slightly longer. Check the operation using an actual load. Incorrect use of a contact protection circuit will adversely affect switching characteristics. Four typical examples of contact protection circuits are shown in the following table: RC Diode Varistor C C R D Varistor R Ind. Load Ind. Load Ind. Load Ind. Load This protection circuit can be used when the load impedance is smaller than the RC impedance in an AC load power circuit. R: Resistor of approximately the same resistance value as the load C: 0. to μf This protection circuit can be used for both AC and DC load power circuits. R: Resistor of approximately the same resistance value as the load C: 0. to μf This protection circuit can be used for DC load power circuits. Use a diode with the following ratings. Reverse withstand voltage: voltage of the load circuit 0 Forward current: More than the load current This protection circuit can be used for both AC and DC load power circuits. For a best result, when using on a power voltage of 24 to 4V AC/DC, connect a varistor across the load. When using on a power voltage of 00 to 2V AC/DC, connect a varistor across the contacts. 3. Do not use a contact protection circuit as shown below: C C Load Load This protection circuit is very effective in arc suppression when opening the contacts. But, the capacitor is charged while the contacts are opened. When the contacts are closed, the capacitor is discharged through the contacts, increasing the possibility of contact welding. This protection circuit is very effective in arc suppression when opening the contacts. But, when the contacts are closed, a current flows to charge the capacitor, causing contact welding. Generally, switching a DC inductive load is more difficult than switching a DC resistive load. Using an appropriate arc suppressor will improve the switching characteristics of a DC inductive load. 3. Notes on PC Board Mounting When mounting 2 or more relays on a PC board, keep a minimum spacing of 5mm in each direction. Manual soldering: Solder the terminals at 3 C within 3 sec. Using a soldering iron of W (Sn-Ag-Cu type) is recommended. Auto-soldering: Solder at 2 C within 4 to 5 sec. Because the terminal is filled with epoxy resin, do not excessively solder or bend the terminal. Otherwise, air tightness will degrade. Avoid touching the relay cover or the epoxy filled terminal with the soldering iron. Use a non-corrosive resin flux. 4. Others. General notice: To maintain the initial characteristics, do not drop or shock the relay. The relay cover cannot be removed from the base during normal operation. To maintain the initial characteristics, do not remove the relay cover. Use the relay in environments free from dust, sulfur dioxide (SO 2 ), hydrogen sulfide (H 2 S), or organic gases. Make sure that the coil voltage does not exceed the applicable coil voltage range. 2. Connecting outputs to electronic circuits: When the output is connected to a load which responds very quickly, such as an electronic circuit, contact bouncing causes incorrect operation of the load. Take the following measures into consideration. a. Connect an integration circuit. b. Suppress the pulse voltage due to bouncing within the noise margin of the load. 3. Do not use relays in the vicinity of strong magnetic fields, as this may affect relay operation. Think Automation and beyond... Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com