INSTRUCTION MANUAL. TC041-L Precipitation Sensor (Precipitation Occurrence & Rainfall Intensity) Sept 2008

Similar documents
INSTRUCTION MANUAL. HMP45C212 Temperature & Relative Humidity Probe. March Copyright 2007 Campbell Scientific (Canada)Corp.

INSTRUCTION MANUAL. C1701 Relay Kit. December Copyright 2007 Campbell Scientific (Canada)Corp.

CURS OHM CURRENT SHUNT TERMINAL INPUT MODULE INSTRUCTION MANUAL

VDIV10.1, VDIV2.1 Voltage Divider Terminal Input Modules

LI190SB QUANTUM SENSOR

Precipition Sensor with analogue Intensity Output ,

CS105 BAROMETRIC PRESSURE SENSOR

SAT SCD/ARGOS INSTRUCTION MANUAL

INSTRUCTION MANUAL , 05106, and R.M. Young Wind Monitors. Revision: 7/05. Copyright (c) Campbell Scientific, Inc.

Precipitation Monitor ,

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

SAT ARGOS INSTRUCTION MANUAL

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

DC1765 CELLULAR PHONE PACKAGE OPERATOR S MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

ECG PATIENT SIMULATOR FIVE LEAD

Model 113 Scintillation Preamplifier Operating and Service Manual

ECG PATIENT SIMULATOR SIX LEAD

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Instruction Manual Model M Switch, DPDT, Manual Select

Broadband Current Probe Series Operation Manual

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

Broadband Current Probe Series Operation Manual

LLAC4 Four-Channel, Low-Level AC Conversion Module Revision: 3/12

NR-LITE NET RADIOMETER INSTRUCTION MANUAL

Bulk Current Injection Probe Test Procedure

PCO-7114 Laser Diode Driver Module Operation Manual

80i-600A AC Current Probe

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

1523, 1524 Thermometer Readout User s Guide

742A Series Resistance Standards

For detailed specifications and ordering info go to

INSTRUCTION MANUAL. CURS Ohm Current Shunt Terminal Input Module Revision: 4/17. Copyright Campbell Scientific, Inc.

supplied o-ring grease can be used to hold the o-ring in the groove during installation.

PDB4. Four Channel Passive Direct Box USER'S GUIDE

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

HDTV Antenna. Contemporary Indoor. User s Guide

Glass Electrode Meter

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

PULSE OXIMETRY SIMULATOR

Operator s Manual. PP016 Passive Probe

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

True RMS AC / DC Power Clamp Meter Model

AMP-13 OPERATOR S MANUAL

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Series 3000 Model R-107A

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

o-ring grease can be used to hold the o-ring in the groove during installation.

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Pen Multimeter. Model

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

Circuit Breaker Finder

LD8000 Series LD8025 LD8050 LD8100

Current Probe Fixture Instruction Manual

SPM-50 RF Spectrum Power Meter PC Software User Manual

INSTRUCTION MANUAL UTL260

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

GNSS-750 ANTENNA GUIDE SITE SELECTION GUIDELINES. Additional Equipment Required. Accessories

Angular Rate Sensor. Owner's Manual

TE525 Tipping Bucket Rain Gage Revision: 10/10

200Amp AC Clamp Meter + NCV Model MA250

Electrical Multimeter

TK 100 Probe Calibrator. Instruction Manual

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Copyright 2014 by Minarik Drives

OPERATOR S MANUAL Model 77E Pneumatic Cable Stripper

Inline Antenna Signal Amplifier

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Warranty Terms & Conditions

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Earth Fault Indicator EFI-BLZ-50 User Manual

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Instruction Sheet SNE SERIES. Cable Chase

Broadband Step-Up Transformer. User Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

o-ring grease can be used to hold the o-ring in the groove during installation.

AMP-12 OPERATOR S MANUAL

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

Global Water Instrumentation, Inc.

Instruction Manual Model Upconverter

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

Model 863 Quad Timing Filter Amplifier Operating and Service Manual

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers

LOW NOISE AMPLIFIER LN4000 OPERATING MANUAL THIS AMPLIFIER IS FOR RECEIVER ONLY. DO NOT USE WITH TRANSMITTER!

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Leaf Wetness Smart Sensor (Part # S-LWA-M003)

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd.

SSR-150xxx-40VL-12P-xC-xxxCS

Transcription:

INSTRUCTION MANUAL TC041-L Precipitation Sensor (Precipitation Occurrence & Rainfall Intensity) Sept 2008 Copyright 2008 Campbell Scientific (Canada)Corp.

WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. ( CSC ) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. ***** Batteries are not warranted. ***** CSC's obligation under this warranty is limited to repairing or replacing (at CSC's option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CSC. CSC will return such products by surface carrier prepaid. This warranty shall not apply to any CSC products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CSC is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. To obtain a Return Merchandise Authorization (RMA), contact CAMPBELL SCIENTIFIC (CANADA) CORP., at (780) 454-2505. An RMA number will be issued in order to facilitate Repair Personnel in identifying an instrument upon arrival. Please write this number clearly on the outside of the shipping container. Include description of symptoms and all pertinent details. CAMPBELL SCIENTIFIC (CANADA) CORP. does not accept collect calls. Non-warranty products returned for repair should be accompanied by a purchase order to cover repair costs.

TABLE OF CONTENTS 1. Specifications:... 2 2. Introduction:... 2 3. Operation:... 3 4. Mounting:... 4 5. Wiring:... 4 6. Program Examples:... 5 6.1. Event Based Output Program Example... 5 7. Maintenance:... 7 Notes: Only open sensor housing in dry conditions, if ever necessary. Moisture contamination may damage internal electronics. Power supply installation should follow applicable National and Local electrical codes. Warnings: Do not conduct power supply installation or wiring of power supply with the AC source turned on. Personal injury and equipment damage may occur.

1. Specifications: Output: 4 20 ma constant current (requires the use of CURS100 current shunt to interface with Campbell Scientific datalogger) Measurement Range (millimeters per minute): 4 8 ma: 0 0.01 mm/min 8 12 ma: 0.01 0.1 mm/min 12 16 ma: 0.1 1 mm/min 16 20 ma: 1 10 mm/min The four output ranges represent four linear characteristic segments of rainfall intensity. Active sensor surface: 25 cm 2 Minimum particle size: 0.2 mm Accuracy (Rainfall only) ± 10% for rainfall intensity Operating Temperature: -30 C - 60 C Power Supply: Weight: Sensor dimensions: Operating voltage: 24 V AC/DC ± 15% Operating current: 90 ma (continuous) Heating current: 1.0 A (maximum) 0.4 Kg 135mm (length), 125mm (width), 38mm (depth) Protection: IP 65 acc. To DIN 40050 EMV: EN 61000-6-2, EN 61000-6-3 2. Introduction: The TC041-L is an effective precipitation occurrence sensor which also serves to measure instantaneous rainfall intensities (i.e. millimeters per minute mm/min). The precipitation can be in the form of drizzle, rain, snow, or hail. The TC041-L does not differentiate between types of precipitation. 2

The sensor signal output is an intensity dependent milliampere (ma) value over the range of 4 to 20mA. The current output represents a rainfall intensity range of 0 to 10 mm/min. The use of a current shunt is required in order to interface the sensor with a Campbell Scientific datalogger (i.e. CURS100). Outputs are divided into four linear characteristic segments. Each segment has a slope that is 10% of the magnitude of the next segment. Figure 1 is a graphical representation of the four rainfall intensity output segments. Rainfall Intensity Outputs 10.00 9.00 Rainfall (mm/min) 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Segments Sensor output (ma) Figure 1 Rainfall Intensity Outputs 3. Operation: When the sensor is operational, light emitting diodes are used to create a light band across the sensor opening. As precipitation falls through the sensor opening a shadowing effect is seen in the light band, on the receiving side. The extent of shading and the duration of shading are used as factors to determine if a precipitation event is occurring, and are used to calculate intensity. The light sent from the emitting diodes is pulse modulated so that ambient light cannot influence the measurement results. 3

In order to avoid icing and snow accumulation the sensor is equipped with a heating system. In freezing conditions the sensor housing will retain a temperature greater than 0 C by means of regulated heating. 4. Mounting: The included mounting hardware is meant to attach the sensor to a mast or tower leg. The mounting hardware is to be used with a 34mm to 50mm (1 3/8 to 2 inch) outside diameter mast. When mounting the sensor be sure to avoid locations where rain shadowing will occur, or where the sensor will be subject to vibration or shock. 5. Wiring: Two cables are connected to the base of the sensor to allow for the connection of both power and signal output. Be sure the main AC power source is disconnected and off while making the power and signal cable connections. The FIN2PWR-L power cable will need to be connected to the C1966 AC transformer once the cable has been run into the appropriate location. The FIN2PWR-L cable will have crimp connectors attached to the end for ease of connection to the AC transformer. Table 1 provides a reference for the power supply wiring. The FIN2COND-L signal output cable will need to be connected to a CURS100 current shunt, which in turn needs to be interfaced with the datalogger. First connect the FIN2COND-L to the CURS100 as listed in 4

Table 2. Once this is complete locate the CURS100 in the datalogger differential channel allocated to measure the sensor. Wire Color Function Connection Black (FIN2PWR-L) Power Ground L1 Terminal of AC Transformer (Crimp connector) Red (FIN2PWR-L) +24VAC Power L2 Terminal of AC Transformer (Crimp connector) Table 1 Power Supply Wiring Connections for CR800 series, CR1000, and CR3000 dataloggers Wire Color Function Connection White (FIN2COND-L) Signal Output CURS100 H» Diff 1H Black (FIN2COND-L) Signal Reference CURS100 L» Diff 1L Clear (FIN2COND-L) Shield Earth Ground Table 2 Differential Datalogger Connections 6. Program Examples: This section provides a program example for the measurement of the TC041-L with a CR1000 datalogger. Precipitation occurrence and rainfall intensity are measured differentially with the use of the CURS100 current shunt module. As the sensor outputs rainfall intensity in four linear characteristic segments, the program will need to account for this when calculating intensity. The datalogger program calculates a milliampere representation of the measured millivolt value in order to calculate rainfall for the specific characteristic segment. 6.1. Event Based Output Program Example ' CR1000 Series Datalogger ' Date: March 3rd, 2008 ' Program Author: Campbell Scientific (Canada) Corp. ' Measure Thies Clima TC041-L Sensor on CR1000 with CURS100 ' SENSOR AND PERIPHERAL WIRING: ' Thies Clima Precipitation Sensor Example 5

' 1H - CUSR100* H - Current Signal ' 1L - CURS100* L - Current Ground ' AG - CURS100* G - Shield ' * NOTE: The CURS100 (100 Ohm current shunt) is a required component of this wiring scheme. ' The sensor outputs a 4-20mA signal that must be converted to a voltage output ' in order to be measured by the datalogger. ' DECLARE PUBLIC VARIABLES: Public Rw Public Rainfall_Rate Public TmpRw Public Prec_Occurance As String ' DECLARE UNITS Units Rw = ma Units Rainfall_Rate = mm/min Units TmpRw = ma ' DATA TABLE DECLARATIONS ' One Minute Average of Raw Measurement DataTable(Table1,true,1) TableHide DataInterval (0,1,Min,10) Average (1,Rw,FP2, 0) EndTable ' Conditional One Minute Table of Rainfall Rate ' (will only occur if Precipitation Rate is greater than zero) ' *** Note: This output is valid for rainfall only. *** DataTable (Rate_1min,Rainfall_Rate>0,-1)'Table size should be customized for individual applications. DataInterval (0,1,Min,10) Sample (1,Rainfall_Rate,FP2) Sample (1,Prec_Occurance,String) EndTable ' \\\\\\\\\\\\\\\\\\\\ PROGRAM SECTION //////////////////// BeginProg Scan (5,Sec,0,0) ' Measure Precipitation (THIES CLIMA SENSOR) VoltDiff (Rw,1,mv5000,1,True,0,_60Hz,0.01,0) ' Redirect Raw 1 Minute Precipitation Values in Order to Calculate Rainfall Rate CallTable Table1 If TimeIntoInterval (0,1,Min) Then GetRecord (TmpRw,Table1,1) 6

' \\\\\\\\\\\\\\\\\\\\ Calculations //////////////////// ' Determine Rate of Rainfall from the one minute average of the raw ' Thies Clima sensor measurements. ' Use starting value of 4.4mA so that particles smaller than sensor resolution (0.001 mm) ' are not counted as rainfall. If TmpRw >= 4.4 AND TmpRw < 8 Then Rainfall_Rate = ((0.0025 * TmpRw) - 0.01) ' mm/min ElseIf TmpRw >= 8 AND TmpRw < 12 Then Rainfall_Rate = ((0.0225 * TmpRw) - 0.17) ' mm/min ElseIf TmpRw >= 12 AND TmpRw < 16 Then Rainfall_Rate = ((0.225 * TmpRw) - 2.6) ' mm/min ElseIf TmpRw >= 16 AND TmpRw < 20 Then Rainfall_Rate = ((2.25 * TmpRw) - 35) ' mm/min Else Rainfall_Rate = 0 EndIf ' Generate Precipitation Occurance Output based on Rainfall Rate. If Rainfall_Rate >0 Then Prec_Occurance = "Yes" Else Prec_Occurance = "No" EndIf ' \\\\\\\\\\\\\\\\\\\\ Output //////////////////// ' Output Conditional 1-Minute Data if a Rainfall Event is occuring: CallTable (Rate_1min) NextScan EndProg 7. Maintenance: It is possible for a layer of dirt to form on the sensor and along the inside of the sensor opening. Typically this is washed off in a precipitation event. However, it is recommended to regularly check the sensor and clean the sensor opening and top with water and a non-abrasive cloth (unsoiled). 7