How to Guide: Controlling Blinds in C-Bus

Similar documents
1. Use of the application program

Instruction manual. art Installation manual

EIB/KNX Switch Actuators. User manual

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

WHEN A PLC IS TOO MUCH, AND SPACE FOR

BMS BMU Vehicle Communications Protocol

FX 3U -20SSC-H Quick Start

K-BUS Switch Actuator

MULTILINK. Installation and Operating Instruction

ServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version.

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

BASIC IMAGE RECORDING

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

[ 4 ] Using pulse train input (F01 = 12)

Chapter 14. using data wires

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

application software

HCA Tech Note 102. Checkbox Control. Home Mode aka Green Mode

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

application software

MD12-2 Metal Loop Detector

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA

CCG Referral App - Northern Ireland

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

MDT Switch Actuator/FanCoil

InstaSPIN-BLDC Lab. DRV8312 Setup Jumpers and switches must be setup properly or the kit will not function correctly!

OTHER RECORDING FUNCTIONS

AN-SERV-009. Luis Miranda 1

Output a drawing layout to a printer, a plotter, or a file. Save and restore the printer settings for each layout.

Installer manual inputs/outputs interface for led KNX

Relay Driver Overview and Applications

GM Arts Firmware v4.0. for BJ Devices MIDI Foot Controllers USER GUIDE

MegaPoints Controller

INSTALLATION & OPERATION MANUAL

instabus EIB product documentation

6.9 Jump frequency - Avoiding frequency resonance

Tebis application software

Magic Contest, version 4.5.1

KNX manual 1-channel flush-mounted switch actuator SU 1

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

Midi Fighter 3D. User Guide DJTECHTOOLS.COM. Ver 1.03

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

Section Table of Contents: Section 11.0

HPVFP High Performance Full Function Vector Frequency Inverter

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Features, Benefits, and Operation

Technical Guide for Radio-Controlled Advanced Wireless Lighting

CineMoco v2.0. anual

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

30.march.2015 MULTIAMP MULTIAMP MIDI PEDALBOARD MIDI PEDALBOARD

BCV-1203 Barcode Verification System Users Guide Version 1.2

BR2 Lap Beacon Manual

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

FlatPack Ultrasonic Sensors

Push-to-talk ios User Guide (v8.0)

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

CAMTO. Arc detecting relay. system. January Revised August D D1200

SeeTool - Solutions for KNX

Altus RTS, Orea RTS & Sonesse RTS Programming

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

Reverse Auction Addon

MegaPoints Servo Controller

WELCOME TO BINGO CALLER

KIRNU - CREAM MOBILE Kirnu Interactive

application software

Chapter5 Camera Settings and Other Functions

30 MODE PLUS. XMOD Modded Controller. User s Manual

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

DAB+ / FM RDS digital clock radio with dual alarm

M-300 & M-320 Low Cost Ultrasonic Sensors

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

FPGA SI Tutorial - Simulating the Reflection Characteristics

Short form User Manual

Ness MCR Multi-Channel Radio Receiver

Medic Box Users Manual

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

USER MANUAL 2AMDI511VPVRDS

Lock Cracker S. Lust, E. Skjel, R. LeBlanc, C. Kim

EZDOME User Guide v.1.2

Chief Architect X3 Training Series. Layers and Layer Sets

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

Directions for Wiring and Using The GEARS II (2) Channel Combination Controllers

AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

REB500 TESTING PROCEDURES

PaperCut PaperCut Payment Gateway Module - Nelnet Business Solutions Commerce Manager Quick Start Guide

Addendum SmartPAC Third Party Communications Firmware

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Transcription:

How to Guide: Controlling Blinds in C-Bus This document is a guide to controlling electrical blinds with C-Bus. Part 1 shows how the blind could be controlled by C-Bus directly and part 2 shows how C-Bus could control dedicated blind controllers made by blind manufacturers. Prior knowledge of C-Bus is assumed as in how to program units such as the C-Bus key input units, relay modules and Touch Screen (C-Touch). A blind controlled by electrical motors is typically a single-phase forward-reverse motors. The forward and reverse direction is achieved by reversing the magnetic field in the winding by physically changing switching positions on the windings. Only forward or reverse should be switched on at any one time. The changeover between forward and reverse should occur after a delay, typically 500ms to 1s. This allows enough time for the motor to release its energy before changing directions. This is bit like driving a car in the forward direction and going into neutral and then (after the car has stopped) switching to reverse. The delay between the changeover allows the motor to discharge its energy and stop before changing directions. If there is no delay then it can be compared to driving a car in the forward direction and putting it into reverse without going into neutral. So basically the two main criteria for controlling a blind motor; 1. Interlocking so that forward and reverse are never switched simultaneously. 2. Delay typically 500ms to 1s. This allows the motor to stop before changing directions. If both these criteria are not met it is very likely that damage to the motor will occur either immediately or overtime. This is one of the reason blind manufacturers recommend dedicated blind controllers that require pulses to be sent for On, Off and Stop functions. The controllers take care of the interlocking and delay. This guide shows how to achieve these two criteria in C-Bus. It is important to check with the blind manufacturer what the requirements are. Always test the installation on the relay outputs without the motor connected and only connect the motor after testing has been completed.

Part 1: How to Control Blinds using C-Bus Only INTERLOCKING To satisfy this you could use 2 channels of the C-Bus 4 channel interlocking relay L5504RVFC or L5504RVFCP or alternatively you could use a standard C-Bus relay in conjunction with the interlocking relay. Plse see diagrams below. Figure 1 : Wiring Diagram for C-Bus Changeover Relay Figure 2: Wiring Diagram 2 (Alternate Wiring Arrangement using 4-ch Changeover Relay and a standard 12-ch Relay)

There are other means of wiring for interlocking using say conventional 240V relays driven by C-Bus relays. Whichever method is used the Up and Down channel on the motor MUST be wired for electrical interlocking. In the Options discussed in the next few pages the C-Bus units used are; 1. 1 x standard C-Bus 4 key input unit 2. 1 x C-Bus changeover relay module 3. 1 x C-Bus touch screen Assuming we have two Blinds called Blind 1 and Blind 2 to control, the following options will show how to individually control the blinds via a C-Bus key input unit and C-Touch, C-Touch only and also perform group control of both blinds. How it all works Up Action Blind 1 Up: A key on C-Bus key input is programmed to trigger two scenes in the C- Touch where Blind 1 Up Scene is triggered on a Short Press and also starts a timer x where x is a few seconds more than the length of time it takes for the blind to go up. This is achieved by the Recall 1 function in the C-Bus key input unit set to 1%. Blind 1 Up Scene is programmed in the C-Touch and it says Reset all groups assigned for Blind 2 Down. Ramp Blind 1 Up to On over 4 seconds. If the blind was going down then all groups related to the Down action are set to Off. As the Blind 1 Up is ramped and because of the Turn On threshold in the Relay module set to 25% the relay Blind 1 Up is assigned to turns On after 1s. Blind Fully Up - When the blind has gone fully up after a time x sec Blind 1 Fully Up scene in the C-Touch is triggered which sets every group address related to Blind 1 to 0.. This is achieved by the Recall 2 function in the C-Bus key input unit set to 8%. If timer x is set to less than the time it takes for the blind to go up the blind will stop before it reaches fully up so it is important to set time x correctly. In summary the C-Bus key is not controlling the blind motor directly. All it is doing is triggering two scenes for the Up Action and two scenes for the Down Action. The scenes are stored in the C-Touch which contains the groups that control the blind motor. If the C-Touch is disconnected off the bus then control of the blinds is lost. This is indicated by the leds on the keys not turning off when pressed (this is how I have programmed it to be).

Stop To stop the blind a Long Release on the key will set Recall 2 which triggers the same Blind Fully Up scene which stops the blind. The Down Action is the reverse of the Up Action. The Changeover relay is programmed as in the following diagrams. The Turn On thresholds are set to 25% which corresponds to 1second if the Group Address assigned to the channel is ramped over a time period of 4s. Delay = Ramp time x Turn On Threshold = 4 sec x 25 % = 1 sec Figure 3: C-Bus Changeover Relay Setup (L5504RVFC or L5504RVFCP)

Figure 4: Turn On threshold set to 25%

Option 1: Control of Blinds via C-Bus Key Input Unit In this option a C-Bus key input unit is programmed as follows: Figure 5: C-Bus 4 Key Input Unit Basically how the Blind would function is as follows; On a Short Press of Key 1 (Up key) the blind 1 would start moving up after a delay (1s). After a time x (10s) seconds the blind would have moved completely up. A Long Release at any time would stop the blind. To continue the up motion the Up key would have to be short pressed again and the blind would move after 1s. If at any time the user presses the Down key while the blind is moving Up then the blind would first stop and then after 1s delay the blind would start its way down. A Long Release on the Down key while the blind is moving down will stop the blind. The delay time is selectable by setting the Turn On threshold in the relay as described earlier. Short Press Recall 1 set to 1%, this triggers scene Blind 1 Going Up. This scene sets groups assigned to the Down action to 0 and ramps the Blind Up to On over 4s. Short Release Start starts timer x set to 10s in this case, this is a few seconds more that the time is takes for the blind to go fully up. Long Press Idle Long Release Recall 2 set to 8%, this triggers scene Blind 1 Fully Up which sets all groups to 0.

After time x has lapsed Recall 2 is issued which then triggers Blind 1 Fully Up which inturn sets all groups to 0. C-Touch : C-Bus Touch Screen In the Touch Screen the scenes to be programmed for Blind 1; 1. Blind 1 Going Up - for UP Action 2. Blind 1 Fully Up to set all groups to Off 3. Blind 1 Going Down for Down Action 4. Blind 1 Fully Down to set all groups to Off. Note : When choosing time x allow for 2 to 5 seconds extra as error margin as electric motors normally slow down over time. The sequence of scenes in C-Touch are shown below. Notice the Triggered By setting is set to Tags which are basically levels on the Blind Up/Down Sc group at 1% and 8 %. Figure 6: Blind 1 Going Up Scene

Figure 7: Blind 1 Fully Up Scene Figure 8: Blind 1 Going Down Scene

Figure 9: Blind 1 Fully Down Scene

Option 2: Control of Blinds via C-Touch only The functions of the C-Bus key input unit in Option 1 is duplicated using a timer function in the C-Touch triggering the same scenes as in Option 1. The timer for Blind 1 for Up Action is programmed in C-Touch shown below. Figure 10: Timer in C-Touch equivalent to C-Bus Key Input Unit Figure 11: Blind 1 Going Up Scene Figure 12: Blind 1 Fully Up Scene

Figure 12: An example of the actual Touch Screen page : The timer settings are programmed as shown in figure 10.

Option 3: Group Control of Blinds via C-Bus Key Input Unit In figure 5 shown earlier Key 1 and Key 2 are for Blind 1 Up and Blind 1 Down. Keys 3 and 4 are programmed for group control of Blind 1 and 2. In the same principle as in option 1 the keys are programmed to trigger two scenes for Up Action and two scenes for Down Action. The only difference is that within the scenes the individual scenes for the blinds are triggered (triggering another scene within a scene is called circular triggering which pops a warning message in C-Touch-this is normal just Click Ok). As an example see this screenshot: Figure 14: All Blinds Up Scene All this scene is doing is by setting the corresponding groups for Blind 1 and 2 to 1% Blind 1 Going Up and Blind 2 Going Up scenes are triggered. Blind 1 Going Up scene is shown in figure 6 earlier. Blinds All Down Sc group is set to 0 to cancel the Down timer if it was in process (like a software interlock).

Figure 15: All Blinds Fully Up Scene All this scene is doing is by setting the corresponding groups for Blind 1 and 2 to 8% causes Blind 1 Fully Up and Blind 2 Fully Up scene to be triggered. Blind 1 Fully Up scene is shown in figure 7 earlier. Blinds All Down Sc and Blind All Up Sc group is set to 0 to reset these group addresses. The Down Action is the reverse of the up action.

Option 4: Group Control of Blinds via C-Touch Only This option is very similar to Option 3. The only difference is that instead of C-Bus keys triggering the scenes the scenes are triggered by timers in C-Touch. Hoping screenshots are self-explanatory! These screenshots are for controlling All Blinds Up or Down. Timer for Up Action Time for Down Action Figure 16: C-Touch Screenshot for Group Control of Blinds Figure 17: Timer for Up Action as show in figure 16 The scenes triggered by the timer in figure 17 are shown in figures 14 and 15.

Important Points to Remember Power Fail (Recovery) When there is a power failure the default levels that the blinds will restore can be set in the settings for the relay under the Recovery tab. I have set the relay channels to restore to 0% which means that the blinds will stay in the position they were just before the power failure. The reason for this is that if the blinds were forced to recover to Up or Down the channel would stay On until something else turned it off. The limit switches in the blind would stop power to the motor but this would not be good practice. To overcome this it could be possible to detect real power failure by a conventional relay with N.O/N.C outputs connected to C-Bus coupler (5104BCL) and trigger events in C- Bus via a scene that could set events to how they should be after a power failure long story short this could be done if required. Ensure that both up and down channels are never set to recover to 100% since both up and down will come on at the same time. Even though the interlocking prevents both channels to be physically on at the same this would not be good programming practice. For the key input units I have selected under the Power Fail tab restore preset settings of 0%. This resets all groups. Since the keys are programmed as a timer and set to trigger scenes in C-Touch, if a power failure does occur when the blind is moving up or down, the timer would be lost and it would be impossible to recover from that state. So basically if a power failure does occur and the blinds are fully up or down they would stay in that position on recovery. If a blind was moving when the power failure occurred then the blind would stay on recovery in the same position it stopped just before the failure. Another option is to have a power-up delay set under the Delay Tab if required. This allows power to be delayed to the channel upon power recovery and minimum time is 10s. Disable Local Toggle (Relay) This feature allows the user to manually override the relay channels. Disable this feature by unchecking Enable Local Toggle under the Global Tab otherwise it would be possible for the user to turn on both up and down channels at one time. It is common practice for most people (hey we have all done this!) to manually turn everything on when something is not working so by disabling this feature we can be sure that the user will not damage the motor by this means. Disable Learn Mode (Relay) Disable Enable Learn Mode under Global tab as this could also cause both Up

and Down channels to be on at once. Learn mode could cause the settings to be lost which would not desirable. Reserve Group Address Ensure Group Addresses used for blind control are reserved and not used elsewhere. The blinds are directly controlled by group addresses within scenes so for example Blind 1 Up should not be assigned to any other scene or key input device. This is to avoid something else apart from the C-Touch scenes triggering the group address.

Part 2: How to Control Blinds with C-Bus using Dedicated Blind Controllers Typically blind controllers made by manufacturers take care of the interlocking and delay required when controlling blind motors. Some of the blind control manufacturers that I have come across are Somfy and Silent Gliss. See links for more; http://www.silentgliss.com.au/ http://www.somfysystems.com/ For the purpose of this guide I am using the Somfy IGC controller as an example. See this line for more info; http://www.somfysystems.com/www/addition/web.instructions/pdf/igc.pdf In the case of the IGC it require short pulses to be sent to the Up/Down inputs. In short; 1. A short pulse to the Up to start the blind Up motion 2. A short pulse to the Down to start the blind Up motion 3. A short pulse to both Up and Down to stop the blind The interlocking and delay is all built into the blind controller. A 3-wire connection typically exists Up/Down/Common. Two channels of a standard C-Bus relay can be wired to (just like you normally would to a load) to the Up side and Down side. Refer to the blind manufacturer for wiring details. Two keys of a C-Bus key input unit could be programmed as follows; Key 1 - Up Action: Pulse the UP group for 1s Key 2 Down Action: Pulse the UP group for 1s To stop the blind both key 1 and 2 have to be pressed simultaneously. Note if the user does a quick Short Press and Short Release then the pulse can be within < 1s + 48s or 1.048s. (48ms is the default debounce time for a Short release to be detected). If the user hold on to the key for longer than 48ms then the pulse can be a maximum 1s + 400ms = 1.4s where 400ms is the default time when Long Press command is issued. These default times can be adjusted under the Global tab of the key input unit.

Figure 18: C-Bus Key Input Unit (Pulse On/Off) If pressing both keys simultaneously is an issue (irritating!) then a 3 rd key can be assigned to the stop function. Here I have used a dummy group address for the 3 rd key just to turn on the led on the 3 rd key but all it does is simultaneously issues the commands for keys 1 (Up) and 2 (Down). Figure 19: C-Bus Key Input Unit (Pulse On/Off/Stop)

So 3 keys in C-Bus would be required very similar to how it is shown in the Somfy documentation. Since a 3 key or multiple of 3 key combination is only available in Reflection, Neo and Saturn these switches could be used for example a 6 key Neo where the left 3 keys is for Blind 1 and right 3 keys is for Blind 2. Otherwise using the option shown in figure 18 two keys would be adequate in which case a standard 4 key input should do for two blinds. If the blind is to be controlled via C-Touch only then it is very easy to send pulses via timers. The time is limited to 1s and above. To stop the blind 2 pulses simultaneously have to be sent and I have used 2 scenes triggered by a timer set to 1s. Figure 20: Example of C-Touch Page for Blind control using timers and scenes to send pulses Figure 21: Timer for 1 Up Button

Figure 22: Timer for Blind 1 Stop Button Figure 23: Blind 1 Pulse Stop On scene triggered by Blind 1 Pulse Sc at 1%

Figure 24: Blind 1 Pulse Stop Off scene triggered by Blind 1 Pulse Sc at 8% Anand Goru Clipsal Integrated Systems Pty Ltd Ph: +612 97949251 Fax: +612 97942327 NSW, Australia. Dated: 03 Sep 2004 Views expressed are my own and not that of Clipsal Integrated Systems Pty Ltd.