Guided Wave in Engineering Structures Using Non-Contact Electromagnetic Acoustic Transducers A Numerical Approach for the Technique Optimisation.

Similar documents
Piezoelectric transducer excitation for guided waves propagation on pipeline with flexural wave modes

Sensitivity analysis of guided wave characters for transducer array optimisation on pipeline inspections

NON-DESTRUCTIVE EVALUATION OF AIRCRAFT CABLES USING ULTRASONIC GUIDED WAVE TECHNIQUE

Inspection of pipe networks containing bends using long range guided waves

NDT 2010 Conference Topics

Determination of the width of an axisymmetric deposit on a metallic pipe by means of Lamb type guided modes

ULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE

Long Range Ultrasonic Testing - Case Studies

Multiple crack detection of pipes using PZT-based guided waves

Modelling of Pulsed Eddy Current Testing of wall thinning of carbon steel pipes through insulation and cladding

Detection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Fig. 1 Feeder pipes in the pressurized heavy water reactor.

Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities

Available online at ScienceDirect. Physics Procedia 70 (2015 )

THE LONG RANGE DETECTION OF CORROSION IN PIPES USING LAMB WAVES

Ultrasonic Guided Waves for NDT and SHM

Guided Wave Inspection of Supported Pipe Locations Using Electromagnetic Acoustic Transducers

Ultrasonic Guided Wave Testing of Cylindrical Bars

HEALTH MONITORING OF ROCK BOLTS USING ULTRASONIC GUIDED WAVES

Selective Excitation of Lamb Wave Modes in Thin Aluminium Plates using Bonded Piezoceramics: Fem Modelling and Measurements

Ultrasonic Guided Wave Applications

Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems

Guided Wave Travel Time Tomography for Bends

Mode mixing in shear horizontal ultrasonic guided waves

PRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves.

Reduction of Dispersive Wave Modes in Guided Wave Testing using Split-Spectrum Processing

Quasi-Rayleigh Waves in Butt-Welded Thick Steel Plate

A Numerical Study of Depth of Penetration of Eddy Currents

Corrosion detection under pipe supports using EMAT Medium Range Guided Waves

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves.

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

Professor Emeritus, University of Tokyo, Tokyo, Japan Phone: ;

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Author s Accepted Manuscript

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

MEASUREMENT OF SURFACE DISPLACEMENT EXCITED BY EMAT TRANSDUCER

DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS

Change in Time-of-Flight of Longitudinal (axisymmetric) wave modes due to Lamination in Steel pipes

Testing of Buried Pipelines Using Guided Waves

Study on Propagation Characteristics of Ultrasonic Guided Wave for EMAT Sensor

Implementation of electromagnetic acoustic resonance in pipe inspection

THE USE OF MAGNETOSTRICTIVE EMAT TRANSDUCERS ON OXIDE SCALED BOILER TUBES

Finite Element Modeling and Simulation of Ultrasonic Guided Wave Propagation using Frequency Response Analysis

In service application of EMAT in Boiler Water Wall Tubes and High Temperature Components

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

Modal Analysis of Microcantilever using Vibration Speaker

Hybrid Active Focusing with Adaptive Dispersion for Higher Defect Sensitivity in Guided Wave Inspection of Cylindrical Structures

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

Fault detection in small diameter pipes using ultrasonic guided wave technology

APPLICATION OF ULTRASONIC GUIDED WAVES FOR INVESTIGATION OF COMPOSITE CONSTRUCTIONAL COMPONENTS OF TIDAL POWER PLANTS

Acoustic Velocity Independent Ultrasonic Flow-Meter

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2

Passive Polymer. Figure 1 (a) and (b). Diagram of a 1-3 composite (left) and a 2-2 composite (right).

Ultrasonic sensors in subsea oil & gas production current use and opportunities

VERSATILE USAGE OF ELECTROMAGNETIC ACOUSTIC TECHNOLOGIES FOR IN-LINE INSPECTION OF AGEING PIPELINES

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

A New Guide Wave Inspection System Using Three Polarized Transverse Wave EMATs without Any Couplant

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

USE OF MICROWAVES FOR THE DETECTION OF CORROSION UNDER INSULATION

Leaky Guided Ultrasonic Waves in NDT

Application of Guided Wave Technology to Tube Inspection

Excitation and reception of pure shear horizontal waves by

Projects in microwave theory 2017

Long Range Guided Wave Monitoring of Rail Track

1. Introduction. 2. Concept. reflector. transduce r. node. Kraftmessung an verschiedenen Fluiden in akustischen Feldern

System Inputs, Physical Modeling, and Time & Frequency Domains

EDDY-CURRENT MODELING OF FERRITE-CORED PROBES

ULTRASONIC GUIDED WAVES FOR AGING WIRE INSULATION ASSESSMENT

MODELLING AND EXPERIMENTS FOR THE DEVELOPMENT OF A GUIDED WAVE LIQUID LEVEL SENSOR

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

Use of Lamb Waves High Modes in Weld Testing

REFLECTION AND TRANSMISSION OF LAMB WAVES AT DISCONTINUITY IN PLATE Z. Liu NDT Systems & Services AG, Stutensee, Germany

BINDT Telford. Guided Wave Testing and Monitoring Over Long and Short Ranges

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Validated AE Application for Continuous Monitoring of the Structural Condition of the Supporting Structure of Offshore Wind Turbines

Final Report: Guided Acoustic Wave Monitoring of Corrosion in Recovery Boiler Tubing

Rayleigh Wave Interaction and Mode Conversion in a Delamination

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity

New Instrument for Rock Bolt Inspection Using Guided Waves

430. The Research System for Vibration Analysis in Domestic Installation Pipes

Research on An Inspection Method for De-bond Defects in Aluminum. Skin-Honeycomb Core Sandwich Structure with Guided Waves

APPLICATIONS OF GUIDED WAVE PROPAGATION ON WAVEGUIDES WITH IRREGULAR CROSS-SECTION. Zheng Fan

Simulation of ultrasonic guided wave inspection in CIVA software platform

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

Ultrasonics. Introduction

Experimental and theoretical investigation of edge waves propagation and scattering in a thick plate with surface-breaking crack-like defect

Mode Dispersion Curves

A Simulation Study of Attenuation Factors in a Gas Pipeline Guided Wave Testing

Transcription:

Excerpt from the Proceedings of the COMSOL Conference 2009 Milan Guided Wave in Engineering Structures Using Non-Contact Electromagnetic Acoustic Transducers A Numerical Approach for the Technique Optimisation. S. Soua* 1, A. Raude 1, and T-H. Gan 1 1 NDT Technology Group, TWI Ltd * S. Soua, Granta Park, Great Abington, Cambridge CB21 6AL, UK, slim.soua@twi.co.uk Abstract: There are over 10 million kilometres of pipes and pipelines around the world that carry hazardous fluids and gases. Fluids include oil, oil products, chemicals such as solvents, caustics, acids, corrosives and combustibles often at high pressure and temperature. These pipes are susceptible to corrosion if they are not protected properly by the environment or the contents. Inspection of pipes is usually mandatory to ascertain their structural integrity as corrosion can lead to failure or rupture of the pipe leading to leakage of hazardous material into the environment or even explosion. Guided wave inspection such as Teletest is a screening technique that is utilised to locate corrosion on pipelines. These commonly use piezoelectric transducers in contact with the pipe surface to induce the ultrasonic wave into the pipe. This paper looks into an alternative approach for generating guided ultrasonic wave in pipes using non-contact electromagnetic transduction (NCET) technique to overcome limitations of using surface contact sensors. Numerical modelling was carried out, using COMSOL, to determine the axisymmetric modes of guided wave with minimal radial displacement and maximum axial displacement. The work focuses on the selection of guided ultrasonics wave (GUW) in the frequency * thickness range of [2.4-3.25] mm.mhz. For standard pipe dimensions, [2.4-3.25] mm.mhz represents short range inspection at relatively high frequency whereas long range inspection of pipes is usually applied at [0.1-1] mm.mhz at frequencies lower then 100kHz. Keywords: Electromagnetic transduction, EMAT, Guided ultrasonic wave, Long range ultrasonics, NDT inspection, Modelling, COMSOL, Tubular structures. 1. Introduction Guided Ultrasonic Wave (GUW) techniques are widely used in the industry for the inspection of pipelines. The standard technique offers rapid screening of long lengths of pipe for the detection of corrosion and other defects under insulation. The existing piezoelectric techniques require mechanical coupling between the transducer and surface of the solid whose properties or structure are to be studied in order to propagate the ultrasonic wave. Coupling is usually achieved using either (i) immersing method (transfer of the ultrasonic signals between the transducer and test sample by placing both objects in liquids) or (ii) contact (the transducer is pressed directly against the test sample with or without coupling gel). For some applications; e.g. inspection of very high temperature pipelines and tubes above 500 o C, both coupling methods are extremely problematic. An alternative approach is to use the contactless and coupling-free NCET technique. The technique is based on the generation of transitory Lorentz forces using an enhanced magnetic field. The aim of this work was to simulate the generation of the GUW in pipes using axisymmetrical NCET and optimise the performance of the NCET technique. In this paper, the longitudinal L(0,3) mode has been selected because it has significant particle displacement at both the inner and outer surfaces which is good for the detection of surface breaking flaws [1]. 2. Model description 2.1 General Modelling of the wave propagation in pipes is an efficient way to predict the performance of

the GUW generation using NCET and establish theoretical parameters that can be subsequently used to optimise the sensor configuration and characteristics needed in the Long Range Ultrasonic Testing (LRUT). Guided waves can be represented in the form of displacement vector at an arbitrary point and this can be written in the frequency domain as: U(x,y,z,t)= A(x,y) exp(jξz) exp(jωt) (1) where ξ is the wave number and ω is the pulsation. The wave propagation is in the z direction and its amplitude is a function of the x and y coordinates [2, 3]. At a fixed ω, the dispersion curve gives fundamental solutions (ξ) of the guided waves that could appear in the pipe when excited using a transitory tone burst signal. When solving the wave equation using (1) as a solution form, an infinite number of ξ are generated; in which the solution is also known as the dispersion curves. In order to determine the dispersion curves of a pipe, the Eigen-frequency analysis was used to study a 40mm length pipe where the edges were clamped in the axial direction. This analysis provided the Eigen-frequencies and the mode shape of the pipe. The wavelength was then calculated based on the mode shape, and finally the velocity of the guided wave was obtained using the relationship (2) between the frequency and the wavelength: c= f.λ (2) For the transient analysis, three formulations were used in the development of the models. The first formulation dealt with the static field induced by a permanent magnet, the second formulation dealt with the induced magnetic field pulsed from the coils, and the third formulation dealt with the elastodynamic wave travelling in the pipe induced by the Lorentz forces. One of the advantages of having two magnetic formulations was to avoid numerical problems in the transient solver when solving a very small oscillation superposed to large static fields (tolerance issues, cancellation effects, etc). The models were first solved using the stationary solver in order to determine the magneto-static solutions. Then, the transient magnetic and structural problems were solved taking into account the magnetic field derived from the stationery solver. 2.2 Case study The electromagnetic transducers have been assessed with the aim to excite an axisymmetrical wave in the cross section of the pipe at high frequencies. A pipe diameter where the longitudinal mode L(0,3) has a cut-off frequency at 269kHz will be used. The excitation profile of the function used to excite the coil was a N cycles modulated tone burst (3): I= I0 sin(ωt) (1-cos(ωt/n)) (t<n/f) (3) The dimension of the pipe, coil and magnet modelled in this paper are summarised in Table 1 below. Table 1: Dimensions used for the models (in mm) Pipe length 1941 Pipe diameter (internal) 120 Pipe thickness 6.575 Coil diameter 133.6 Magnet diameter 134 Magnet thickness 8 2.3 Configuration of NCET The efficiency and performance of different types of EMATs have been reported in [4, 5]. These EMATs were used to excite in-plane and out of plane waves in half space configuration. The configuration in Figure 1 shows an example of an axisymmetric NCET coil setup to excite L waves, Rayleigh waves, or guided modes. This configuration was chosen for the modelling work conducted in this paper. Figure 1. Schematic of the current, magnetic field and the Lorentz force, generated in tubular structure.

With this configuration, the magnetic field is present in the radial direction with the current tangent to the pipe and the resulting Lorentz force in the axial direction (Figure 1). The structure (i.e. coil, magnet and pipe) was represented as a 2D axisymmetric model in COMSOL. Indeed, the geometry, loadings, boundary conditions and materials were symmetric with respect to the axis. In the transitory analysis, the discretisation in the pipe region used mesh criteria that respects the condition le=λ L03 /6, where le is the element length in the z direction. 4.1 Eigen-frequency analysis: The results of the stationary analysis are presented in the Appendix. The table shows a list of wave mode frequencies and wave-number determined using COMSOL. Figure 3 shows the correlation between the results from the stationary analysis and the analytical calculations based on potential decomposition [5]. 3. Technique optimisation In order to investigate the propagation of the GUW in pipe using NCET, advanced post processing techniques had to be introduced. The two dimensional Fast Fourier Transform (2D FFT) was used in order to dissociate the mode content of the resulting displacement wave along the pipe. This technique transforms the displacement extrusion plot (Time, Distance) into dispersion curve plot (Frequency, Wavenumber) in the frequency bandwidth excited by the tone burst signal. In this model, a 5-cycle 441 khz tone burst signal was applied to the NCET technique. Figure 2 shows frequency spectrum of the signal. Figure 3. Correlation of the COMSOL dispersion curves results with analytical solution. The design of the NCET technique focused on exciting the L(0,3) mode at maximum group velocity to simplify experimental verification. This mode has significant particle displacement at both the inner and outer surfaces, demonstrating potential for surface defect detection. In addition, (441 khz, 459m -1 ) is the point of minimum dispersion of the L(0,3) which is advantageous for applications requiring propagation of GUW over long distances [1]. Table 2 shows L(0,3) and L(0,4) mode shapes of the guided waves in the frequency range from 400 khz to 500 khz (wave-number from300 m-1 to 600 m -1 ) at both the inner and outer surface of the pipe. Table 2: Mode shape of the L(0,3) and L(0,4) GUW Figure 2. Frequency spectrum of the 5 cycles tone burst excitation. The purpose of the optimisation was to assess the mode contents and amplitudes of L(0,1), L(0,2), L(0,3), L(0,4) and L(0,5) modes excited using the NCET technique. By optimising the NCET parameters the authors aimed to select the L(0,3) mode in order to enhance its amplitude and make it more efficient for complex inspection. 4. Results L(0,3) f (Hz) 402,476 448,270 492,446 L(0,4) f (Hz) 426,475 431,332 490,140

The study showed that L(0,1) and L(0,2) modes had concentrated energy near the outer surface of the pipe and did converge to Rayleigh waves at high frequencies. For this reason, these modes proved to be unsuitable for the inspection of pipes with internal corrosion or erosion. The L(0,4) mode may be used but remained relatively dispersive at high frequencies. Consequently, the L(0,3) mode remained the best mode for the application under study, because of its less dispersiveness at high frequencies and the possibility to cancel any other wave modes. As a result of these advantages, L(0,3) was expected to increase the resolution of the inspection leading to less complicated data analysis. 4.2 Transient analysis: a) Conf. 1: Full magnet without spacing In order to select the L(0,3) mode, the following part of the study presents a comparison between three NCET configurations where one used a full magnet covering the entire coil and the two others used a series of magnets (7 and 14 respectively for configurations 2 and 3) separated by a spacing equal to the mode s wavelength, λ L03. The spacing was selected as such, to improve the amplitude of the mode, however the number of elements (i.e. magnets) chosen was arbitrary. The 2D FFT results for those configurations are shown in the Figures 4, and 5. The parameters used in the 2D FFT analysis are summarised below: The time stepping was 2e -7 s. The resulting maximum frequency range was 5 MHz and the resulting resolution was 2 khz. The distance stepping was 5e -3 m. The resulting maximum wave-number covered by the analysis was 1291m -1 and the resulting resolution was 3.23m -1. The content of the generated field was dissociated and appeared to be in agreement with the dispersion curves obtained using the Eigenfrequency analysis of COMSOL (Figures 4). Figures 5 clearly shows an improvement of the L(0,3) mode spectra amplitude in the case of the selective NCET. In fact the amplitude of this mode increased compared with the case of the standard NCET, and the amplitude of the L(0,4) and L(0,5) decreased. b) Conf. 2: Series of 7 magnets with λ L03 spacing c) Conf. 3: Series of 14 magnets with λ L03 spacing Figure 4. 2D FFT analysis of the mode content for various NCET configurations.

L01 a) Configuration 1: Full magnet without spacing L01 L02 L02 b) Conf. 2: Series of 7 magnets with λl03 spacing L01 L02 L03 L04 L03 L04 L03 L04 L05 L05 L05 c) Conf. 3: Series of 14 magnets with λl03 spacing Figure 5. 2DFFT amplitude of the modes for various NCET configurations. Table 3 summarises the maximum amplitude obtained for the various modes, after 2D FFT post-processing for the three configurations previously studied (Figure 5). It can be noted that the amplitudes obtained with the use of multi-element magnets were improved from the original configuration. Moreover, the increase of elements enabled to increase the amplitude of L(0,3) and decrease the one of unwanted modes, such as L(0,4) and L(0,5). Notice that most of the L(0,3) and L(0,4) mode content appears in the axial DC, the L(0,1) and the L(0,2) mode content appears in the radial DC (figures 5). The axial component of the mode is more likely to be detected using NCET as a receiver transducer. Table3: Summary of modes maximum amplitude obtained after 2D FFT for various configurations Maximum Amplitude (10-9 ) Conf. 1 2 3 L(0,1) 0.2 1.1 +0.9 2.5 +2.3 L(0,2) 0.4 2.3 +1.9 2.7 +2.3 L(0,3) 0.5 4 +3.5 5 +4.5 L(0,4) 0.3 1 +0.7 0.6-0.3 L(0,5) 0.23 0.3 +0.07 0.1 +0.13 5. Conclusions The work carried out in this paper showed that COMSOL can be used to develop the modelling and the optimisation of guided wave generation and properties in order to inspect tubular structures such as pipes. The results were well correlated with the Eigen-frequency approach. In this paper, using multiphysics interaction, a new concept for generating GUW using non-contact transducers has been established. A high frequency range was selected in the order of 3mm.MHz. This range corresponds to a wavelength of 15mm (λ L03 ) which allow the short range inspection using high resolution. The optimisation of the NCET transducer using multi-magnets with constant spacing proved to be very efficient to select one mode and reduce the amplitude of undesired modes, such as L(0,4) and L(0,5). 6. Further work Further work will be carried out experimentally to validate the NCET approach. Experiments will be conducted to prove the performance of the L(0,3) mode when testing fluid loaded pipes. 7. References 1. Thomas R. Hay, Joseph L. Rose, Flexible PVDF comb transducers for excitation of axisymmetric guided waves in pipe, Sensors and Actuators A 100 18 23 (2002). 2. Slim Soua, Septimonette Chan, Tat-Hean Gan, Modelling of long range ultrasonic waves in

complex structures, BINDT (15-18 September 2008, Macclesfield, Cheshire, UK). 3. T. Hayashi, C. Tamayama, M. Murase, Wave structure analysis of guided waves in a bar with an arbitrary cross-section, Ultrasonics 44 17 24, 2006. 4. Y. Kurozumi, Y. Okano, Performance Characteristics of Electromagnetic Acoustic Transducer, 121-127, Electromagnetic Nondestructive Evaluation, T. Takagi et al. (Eds.), IOS Press, 1997. 5. http://www.ndt-ed.org /EducationResources/ CommunityCollege/Ultrasonics/EquipmentTrans /emats.htm 8. Acknowledgements This work was funded by the European FP7 project TidalSense. The authors would like to thank Magnus Olsson (magnus.olsson@comsol.com) for his kind contribution to the COMSOL model development. 9. Appendix The table below presents the numerical values of the wave modes calculated using the Eigen-frequency analysis of COMSOL. The number n was deduced based on the post processing of the displacement shape; it represents the number of the resulting of wavelength of the pipe deformation. λ was then deduced from the following formula (4): λ=l/n. (4) where L is the length of the pipe (L=40mm). f(hz) n λ(mm) c(m/s) k(1/m) 13465 0.5 80.00 1077 79 15641 0.5 80.00 1251 79 36070 1 40.00 1443 157 66818 0.5 80.00 5345 79 67827 1.5 26.67 1809 236 104124 2 20.00 2082 314 132206 1 40.00 5288 157 142295 2.5 16.00 2277 393 181192 3 13.33 2416 471 194712 1.5 26.67 5192 236 220295 3.5 11.43 2518 550 246307 0.5 80.00 19705 79 251258 2 20.00 5025 314 259371 4 10.00 2594 628 274540 1 40.00 10982 157 297347 2.5 16.00 4758 393 298322 4.5 8.89 2652 707 313028 1.5 26.67 8347 236 330777 3 13.33 4410 471 337112 5 8.00 2697 785 355723 3.5 11.43 4065 550 356698 2 20.00 7134 314 375741 5.5 7.27 2733 864 377883 4 10.00 3779 628 400395 4.5 8.89 3559 707 402476 2.5 16.00 6440 393 414221 6 6.67 2761 942 424432 5 8.00 3395 785 426475 1.5 26.67 11373 236 431333 2 20.00 8627 314 433116 1 40.00 17325 157 448173 0.5 80.00 35854 79 448270 3 13.33 5977 471 450275 5.5 7.27 3275 864 451987 2.5 16.00 7232 393 452573 6.5 6.15 2785 1021 477856 5.5 7.27 3475 864 490140 3 13.33 6535 471 490818 7 5.71 2805 1100 492447 3.5 11.43 5628 550 497254 0.5 80.00 39780 79 506985 6.5 6.15 3120 1021 528723 1 40.00 21149 157 528978 7.5 5.33 2821 1178 533696 4 10.00 5337 628 537448 7 5.71 3071 1100 540765 3.5 11.43 6180 550 563909 1.5 26.67 15038 236 567074 8 5.00 2835 1257