Pressure transmitter For general industrial applications Model A-10

Similar documents
Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-10

OEM pressure transmitter For mobile working machines Model MH-3

High-quality pressure transmitter For general industrial applications Model S-20

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Flush pressure transmitter For viscous and solids-containing media Model S-11

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Electronic temperature switch with display Model TSD-30

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

Resistance thermometer Model TR31, miniature design

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure Transmitter SIL

Pressure transmitter For sanitary applications Model SA-11

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Submersible pressure sensor For oils and fuels Model LF-1

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Submersible pressure sensor For water and wastewater Model LW-1

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Submersible pressure sensor For superior applications Model LF-1

Resistance thermometer Model TR30, compact design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

ED701 General Industry Pressure Transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Indicator for panel mounting Model

Materials (other materials see WIKA diaphragm seal program) Model S-10

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Float switch For industrial applications, plastic version Model RLS-2000

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

High-precision process calibrator Model CED7000

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Resistance Thermometers Model Series TR7X0, Sheathed Design

Digital indicator for panel mounting With multi-function input Model DI25

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Hand-held temperature calibrator Model CEP3000

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

NAT Applications. Features

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Field indicator for current loops with HART communication Models DIH50, DIH52

ECT Applications. Features

Heavy Duty Pressure Transducers

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

U5300 Industrial Pressure Transducer

NAT Applications. Features

Mechatronic pressure measurement. Applications. Special features. Description

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Your Global Automation Partner. PT2000 Pressure Transmitter

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Screw-in resistance thermometers with plug connector

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Digital inductive conductivity transmitter

U5700 Submersible Liquid Level Pressure Transducer

M5200 Industrial Pressure Transducer

Electronic Pressure Switch Type MEP

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

M5200 Industrial Pressure Transducer

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Field indicator for current loops with HART communication Models DIH50, DIH52

Electronic Temperature Transmitters

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Low Pressure NSL Applications. Features

Analogue Temperature Transmitter

Industrial Pressure Transmitter

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Valve Island with Electronic I/O

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Primary-standard resistance thermometry bridge Model CTR9000

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

General Specification

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Electronic Pressure Measurement

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

ph or ORP Transmitter

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Transcription:

Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology Hydraulics and pneumatics Pumps and compressors Special features Measuring ranges from 0 0.6 to 0 1,000 bar Non-linearity 0.25 % or 0.5 % Output 4... 20 ma, DC 0... 10 V, DC 0... 5 V and others Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m Process connection ¼ A DIN 3852-E, ¼ NPT and others Pressure transmitter model A-10 Description The model A-10 pressure transmitter for general industrial applications is not only notable for its compact design, but it also offers excellent quality at an extremely competitive price. The user can choose between a non-linearity of 0.25 % and 0.5 %. A free test certificate provides information on the measuring points recorded during manufacture. The model A-10 is set up for worldwide use through the international culus and OST-R certification. The various pressure units and process connections required for particular operating conditions are available at short notice. Page 1 of 8 Data sheets showing similar products: Pressure transmitter for general applications; model S-10; see data sheet PE 81.01

Measuring ranges Relative pressure bar Measuring range 0... 0.6 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 1) 0... 16 1) Overpressure limit 1.2 2 3.2 5 8 12 20 32 Measuring range 0... 25 1) 0... 40 0... 60 0... 100 0... 160 0... 250 0... 400 0... 600 Overpressure limit 50 80 120 200 320 500 800 1,200 Measuring range 0... 1,000 Overpressure limit 1,500 psi Measuring range 0... 15 0... 25 0... 30 0... 50 0... 100 0... 160 1) 0... 200 1) 0... 300 1) Overpressure limit 30 60 60 100 200 290 400 600 Measuring range 0... 500 0... 1,000 0... 1,500 0... 2,000 0... 3,000 0... 5,000 0... 10,000 Overpressure limit 1,000 1,740 2,900 4,000 6,000 10,000 17,400 Absolute pressure bar Measuring range 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 0... 16 0... 25 Overpressure limit 2 3.2 5 8 12 20 32 50 psi Measuring range 0... 15 0... 25 0... 30 0... 50 0... 100 0... 150 0... 200 0... 300 Overpressure limit 30 60 60 100 200 290 400 600 Vacuum and +/- measuring range bar Measuring range -1... 0-1... +0.6-1... +1.5-1... +3-1... +5 Overpressure limit 2 3.2 5 8 12 Measuring range -1... +9-1... +15-1... +24 Overpressure limit 20 32 50 psi Measuring range -30 inhg... 0-30 inhg... +15-30 inhg... +30-30 inhg... +60-30 inhg... +100 Overpressure limit 30 60 60 150 250 Measuring range -30 inhg... +160-30 inhg... +200-30 inhg... +300 Overpressure limit 350 450 600 1 ) If the medium water is measured, a higher overpressure limit is recommended. The given measuring ranges are also available in kg/cm 2, MPa and kpa. Other measuring ranges available on request Vacuum resistance Yes Output signal Signal type Current () Voltage () Ratiometric () Signal 4... 20 ma DC 0... 10 V DC 0... 5 V DC 1... 5 V DC 0.5... 4.5 V DC 0.5... 4.5 V Other output signals available on request Depending on the signal type the following loads apply: Current (): (power supply - 8 V) / 0.02 A Voltage (): > maximum output signal / 1 ma Ratiometric (): > 4.5k Page 2 of 8

Voltage supply Power supply Output signal Power supply Standard Option 4... 20 ma DC 8... 30 V DC 8... 35 V 2) DC 0... 10 V DC 14... 30 V DC 14... 35 V DC 0... 5 V DC 8... 30 V DC 8... 35 V DC 1... 5 V DC 8... 30 V DC 8... 35 V DC 0.5... 4.5 V DC 8... 30 V DC 8... 35 V DC 0.5... 4.5 V ratiometric DC 5 V ± 10 % - 2) Not possible with non-linearity 0.25 % BFSL The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.3 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC 60950-1, or class 2 in accordance with U310/U585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude. Total current consumption Current (): Signal current, max. 25 ma Voltage (): 8 ma Ratiometric (): 8 ma Accuracy Optionally the model A-10 is available with an improved non-linearity. Depending on the selected non-linearity the following values result: Non-linearity per BFSL (IEC 61298-2) Measuring deviation of the zero signal Standard ±0.5 % of span Typical: ±0.5% of span Maximum: ±0.8 % of span Option ±0.25 % of span Typical: ±0.15% of span Maximum: ±0.4 % of span Accuracy at room temperature 3) ±1 % of span ±0.5 % of span ±0.6 % of span (at DC 0... 5 V) 3) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2), calibrated in vertical mounting position with process connection facing downwards Non-repeatability 0.1 % of span Signal noise ±0.3 % of span Temperature error at 0... 80 C Typical: 1 % of span Maximum: 2.5 % of span Long-term drift ±0.1 % of span Page 3 of 8

Time response Settling time < 4 ms Switch-on time < 15 ms Reference conditions (per IEC 61298-1) Temperature 15... 25 C Atmospheric pressure 860... 1,060 mbar Humidity 45... 75 % relative Power supply DC 24 V Mounting position as required Operating conditions Ingress protection (per IEC 60529) see table Specifications Vibration resistance 10 g (per IEC 60068-2-6, under resonance) 4) 20 g on request 5) 4) With approval L and measuring range 0... 0.6 only possible with accuracy 1 % 5) With approval L only possible with measuring ranges > 0... 1 bar Shock resistance 500 g (per IEC 60068-2-27, mechanical) Service life 10 million load cycles Process connections Standard Thread size EN 837 ⅛ B 6) ¼ B ¼ female ¼ female, with flange connection 7) ⅜ B ½ B DIN 3852-E 8) ¼ A ½ A M14 x 1.5 ANSI/ASME B1.20.1 ⅛ NPT 6) ¼ NPT ¼ NPT female ½ NPT DIN 16288 M20 x 1.5 ISO 7 R ¼ R ⅜ R ½ KS PT ¼ PT ½ PT ⅜ SAE 8) 9) 7/16-20 UNF O-ring BOSS 6) Maximum measuring range 400 bar 7) Maximum measuring range 100 bar 8) Maximum overpressure limit of 600 bar 9) Maximum permissible temperature -10... +100 C All process connections are available, as standard, with an entry bore of diameter 3.5 mm. Optional diameters for: ¼ A DIN 3852-E: Ø 6 mm, Ø 0.6 mm, Ø 0.3 mm ¼ NPT: Ø 6 mm, Ø 0.6 mm, Ø 0.3 mm Sealings For the process connections of the following standards the listed sealing materials are available. Standard Standard Option EN 837 Copper Stainless steel DIN 3852-E NBR FKM SAE FKM - The sealings listed under Standard are included in the delivery. Temperatures Permissible temperature ranges Standard Option Ambient 0... +80 C -30... +100 C Medium 0... +80 C -30... +100 C Storage -20... +80 C -30... +100 C Page 4 of 8

Electrical connections Specifications Designation Ingress protection Wire cross-section Cable diameter Cable material Angular connector DIN 175301-803 A with mating connector IP 65 up to max. 1.5 mm 2 6... 8 mm - with solid laid cable IP 65 3 x 0.75 mm 2 6 mm PUR Angular connector DIN 175301-803 C with mating connector IP 65 up to max. 0.75 mm 2 4.5... 6 mm - with solid laid cable IP 65 4 x 0.5 mm 2 6.2 mm PUR Circular connector M12 x 1 (4-pin) without mating connector IP 67 - - - straight with solid laid cable IP 67 3 x 0.34 mm 2 4.3 mm PUR angled with solid laid cable IP 67 3 x 0.34 mm 2 4.3 mm PUR Cable outlet unshielded 10) IP 67 3 x 0.34 mm 2 4 mm PUR OEM version, unshielded 11) IP 67 3 x 0.14 mm 2 2.85 mm TPU 10) Not possible with approval L 11) up to max. 90 C The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection. Mating connectors (with and without cable) are also separately available as accessories. Cable lengths of 2 m or 5 m are available Short-circuit resistance S+ vs. 0V Reverse polarity protection U B vs. 0V Insulation voltage DC 500 V Connection diagrams All connectors with solid laid cable have the same colour assignment as the unshielded cable outlet. Angular connector DIN 175301-803 A Cable outlet, unshielded 3 1 2 U B 1 1 0V 2 2 S + - 3 U B brown brown 0V blue blue S + - black Angular connector DIN 175301-803 C Cable outlet, OEM version, unshielded U B 1 1 0V 2 2 S + - 3 U B brown brown 0V blue blue S + - black Circular connector M12 x 1 (4-pin) U B 1 1 4 3 0V 3 3 1 2 S + - 4 U B 0V S + Positive power supply terminal Negative power supply terminal Analogue output Page 5 of 8

Materials Wetted parts < 10 bar: Stainless steel 316L 10 bar: Stainless steel 316L and 13-8 PH Non-wetted parts Stainless steel 316L HNBR PA For sealing materials see "Process connections" For materials of the cables see "Electrical connections" Pressure transmission medium < 0... 10 bar relative: Synthetic oil 0... 25 bar absolute: Synthetic oil 0... 10 bar relative: Dry measuring cell CE conformity Pressure equipment directive 97/23/EC EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial application) Approvals culus, safety (e.g. electr. safety, overpressure,...), USA, Canada OST-R, import certificate, Russia L, ships, shipbuilding (e.g. offshore), ermany Approvals, see website. Dimensions in mm Pressure transmitters with angular connector form A with angular connector form C with angular connector form A, flange connection with circular connector M12 x 1 with standard cable outlet, unshielded Weight: approx. 350 g with cable outlet OEM version, unshielded Page 6 of 8

Process connections ¼ A DIN 3852-E 14 ½ A DIN 3852-E 17 M14 x 1.5 14 ¼ B EN 837 13 ⅜ B EN 837 16 ½ B EN 837 20 M20 x 1.5 20 7/16-20 UNF BOSS 12.85 Female Female L2 L3 D1 ¼ EN 837 20 13 10 Ø 25 L2 D1 ¼ NPT 20 14 Ø 25 ⅛ B EN 837 10 ⅛ NPT 10 ¼ NPT 13 ½ NPT 19 R ¼ 13 R ⅜ 15 R ½ 19 PT ¼ 13 PT ⅜ 15 PT ½ 19 ¼ female, with flange connection dimensions see drawing For information on tapped holes and welding sockets, see Technical Information IN 00.14 at www.wika.com Page 7 of 8

Accessories and spare parts Mating connector Sealing for mating connector Sealing for process connection Mating connector Designation Order number without cable with 2 m cable with 5 m cable Angular connector DIN 175301-803 C 1439081 12) 11225823 11250194 Angular connector DIN 175301-803 A with cable gland, metric 11427567 11225793 11250186 with cable gland, conduit 11022485 - - Circular connector M12 x 1, 4-pin straight 2421262 11250780 11250259 angled 2421270 11250798 11250232 12) Connector not permissible for A-10 with L approval. Sealings for mating connectors Designation Order number Angular connector DIN 175301-803 A 1576240 Angular connector DIN 175301-803 C 11169479 Sealings for process connection Designation Order number Cu Stainless steel NBR FKM ¼ EN 837 11250810 11250844 - - M14 x 1.5 - - 1537857 1576534 ½ EN 837 11250861 11251042 - - M20 x 1.5 11250861 11251042 - - ⅛ EN 837 11251051 - - - ¼ DIN 3852-E - - 1537857 1576534 ½ DIN 3852-E - - 1039067 1039075 Only use the accessories and spare parts listed, otherwise it could lead to the loss of the approval. Ordering information Model / Measuring range / Output signal / Power supply / Non-linearity / Temperature range / Process connection / Sealing / Electrical connection 2011 WIKA Alexander Wiegand SE & Co. K, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 07/2014 B WIKA Alexander Wiegand SE & Co. K Alexander-Wiegand-Straße 30 63911 Klingenberg/ermany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de