Pressure transmitter for general industrial applications Model A-10

Similar documents
Pressure transmitter For general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-10

OEM pressure transmitter For mobile working machines Model MH-3

High-quality pressure transmitter For general industrial applications Model S-20

Flush pressure transmitter For viscous and solids-containing media Model S-11

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Electronic temperature switch with display Model TSD-30

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

Resistance thermometer Model TR31, miniature design

Pressure Transmitter SIL

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Submersible pressure sensor For oils and fuels Model LF-1

Pressure transmitter For sanitary applications Model SA-11

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Resistance thermometer Model TR30, compact design

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For superior applications Model LF-1

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

ED701 General Industry Pressure Transmitter

Indicator for panel mounting Model

Materials (other materials see WIKA diaphragm seal program) Model S-10

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Float switch For industrial applications, plastic version Model RLS-2000

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-precision process calibrator Model CED7000

Digital indicator for panel mounting With multi-function input Model DI25

Hand-held temperature calibrator Model CEP3000

Resistance Thermometers Model Series TR7X0, Sheathed Design

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

NAT Applications. Features

U5300 Industrial Pressure Transducer

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

NAT Applications. Features

Field indicator for current loops with HART communication Models DIH50, DIH52

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Heavy Duty Pressure Transducers

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Screw-in resistance thermometers with plug connector

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

ECT Applications. Features

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Your Global Automation Partner. PT2000 Pressure Transmitter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

U5700 Submersible Liquid Level Pressure Transducer

M5200 Industrial Pressure Transducer

Electronic Pressure Switch Type MEP

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Mechatronic pressure measurement. Applications. Special features. Description

M5200 Industrial Pressure Transducer

Analogue Temperature Transmitter

Digital inductive conductivity transmitter

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Valve Island with Electronic I/O

Electronic Temperature Transmitters

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Industrial Pressure Transmitter

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Primary-standard resistance thermometry bridge Model CTR9000

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Field indicator for current loops with HART communication Models DIH50, DIH52

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

General Specification

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

ph or ORP Transmitter

In-Line Resistance Thermometers Model TR25

Low Pressure NSL Applications. Features

INSERTION paddle wheel flowmeter for continuous flow measurement

Transcription:

Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology Hydraulics and pneumatics Pumps and compressors Special features Measuring ranges from 0 1 to 0 600 bar Non-linearity 0.25 % or 0.5 % Output 4... 20 ma, DC 0... 10 V, DC 0... 5 V and others Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m Process connection ¼ A DIN 3852-E, ¼ NPT and others Pressure transmitter model A-10 Description The model A-10 pressure transmitter for general industrial applications is not only notable for its compact design, but it also offers excellent quality at an extremely competitive price. The user can choose between a non-linearity of 0.25 % and 0.5 %. A free test certificate provides information on the measuring points recorded during manufacture. The model A-10 is set up for worldwide use through the international culus and OST certification. The various pressure units and process connections required for particular operating conditions are available at short notice. Page 1 of 8 Data sheets showing similar products: Pressure transmitter for general applications; model S-10; see data sheet PE 81.01

Measuring ranges Relative pressure bar Measuring range 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 1) 0... 16 1) 0... 25 1) Overpressure limit 2 3.2 5 8 12 20 32 50 Measuring range 0... 40 0... 60 0... 100 0... 160 0... 250 0... 400 0... 600 Overpressure limit 80 120 200 320 500 800 1,200 psi Measuring range 0... 15 0... 25 0... 30 0... 50 0... 100 0... 160 1) 0... 200 1) 0... 300 1) Overpressure limit 30 60 60 100 200 290 400 600 Measuring range 0... 500 0... 1,000 0... 1,500 0... 2,000 0... 3,000 0... 5,000 0... 10,000 Overpressure limit 1,000 1,740 2,900 4,000 6,000 10,000 17,400 Absolute pressure bar Measuring range 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 0... 16 0... 25 Overpressure limit 2 3.2 5 8 12 20 32 50 psi Measuring range 0... 15 0... 25 0... 30 0... 50 0... 100 0... 150 0... 200 0... 300 Overpressure limit 30 60 60 100 200 290 400 600 Vacuum and +/- measuring range bar Measuring range -1... 0-1... +0.6-1... +1.5-1... +3-1... +5 Overpressure limit 2 3.2 5 8 12 Measuring range -1... +9-1... +15-1... +24 Overpressure limit 20 32 50 psi Measuring range -30 inh... 0-30 inh... +15-30 inh... +30-30 inh... +60-30 inh... +100 Overpressure limit 30 60 60 150 250 Measuring range -30 inh... +160-30 inh... +200-30 inh... +300 Overpressure limit 350 450 600 1 ) If the medium water is measured, a higher overpressure limit is recommended. The given measuring ranges are also available in kg/cm 2, MPa and kpa. Other measuring ranges available on request Vacuum resistance Yes Output signal Signal type Current () Voltage () Ratiometric () Signal 4... 20 ma DC 0... 10 V DC 0... 5 V DC 1... 5 V DC 0.5... 4.5 V DC 0.5... 4.5 V Other output signals available on request Depending on the signal type the following loads apply: Signal type Load in Ω Current () (power supply - 8 V) / 0.02 A Voltage () > maximum output signal / 1 ma Ratiometric () > 4.5k Page 2 of 8

Voltage supply Power supply Output signal Power supply Standard Option 4... 20 ma DC 8... 30 V DC 8... 35 V 1) DC 0... 10 V DC 14... 30 V DC 14... 35 V DC 0... 5 V DC 8... 30 V DC 8... 35 V DC 1... 5 V DC 8... 30 V DC 8... 35 V DC 0.5... 4.5 V DC 8... 30 V DC 8... 35 V DC 0.5... 4.5 V ratiometric DC 5 V ± 10 % - 1) Not possible with non-linearity 0.25 % BFSL The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.3 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC 60950-1, or class 2 in accordance with U310/U585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude. Total current consumption Signal type Current () Voltage () Ratiometric () Total current consumption Signal current, max. 25 ma 8 ma 8 ma Accuracy Optionally the model A-10 is available with an improved non-linearity. Depending on the selected non-linearity the following values result: Standard Option Non-linearity per BFSL (IEC 61298-2) ±0.5 % of span ±0.25 % of span Measuring deviation of the zero signal Typical: ±0.5% of span Maximum: ±0.8 % of span Typical: ±0.15% of span Maximum: ±0.4 % of span Accuracy at room temperature 1) ±1 % of span ±0.5 % of span ±0.6 % of span (at DC 0... 5 V) 1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2), calibrated in vertical mounting position with process connection facing downwards Non-repeatability 0.1 % of span Signal noise ±0.3 % of span Temperature error at 0... 80 C Typical: 1 % of span Maximum: 2.5 % of span Long-term drift ±0.1 % of span Page 3 of 8

Time response Settling time < 4 ms Switch-on time < 15 ms Operating conditions Ingress protection (per IEC 60529) see table "Specifications" Vibration resistance 10 g (IEC 60068-2-6, under resonance) 20 g available on request Shock resistance 500 g (IEC 60068-2-27, mechanical) Service life 10 million load cycles Temperatures Permissible temperature ranges Standard Option Ambient 0... +80 C -30... +100 C Medium 0... +80 C -30... +100 C Storage -20... +80 C -30... +100 C Reference conditions (per IEC 61298-1) Temperature 15... 25 C Atmospheric pressure 860... 1,060 mbar Process connections Standard Thread size EN 837 ⅛ B 1) ¼ B ¼ female ⅜ B ½ B DIN 3852-E 2) ¼ A ½ A M14 x 1.5 ANSI/ASME B1.20.1 ⅛ NPT 1) ¼ NPT ¼ NPT female ½ NPT DIN 16288 M20 x 1.5 ISO 7 R ¼ R ⅜ R ½ KS PT ¼ PT ½ PT ⅜ SAE 2) 3) 7/16-20 UNF O-ring BOSS 9/16-18 UNF O-ring BOSS 1) Maximum measuring range 400 bar 2) Maximum overpressure limit of 600 bar 3) Maximum permissible temperature -10... +100 C All process connections are available, as standard, with an entry bore of diameter 3.5 mm. Optional diameters for: ¼ A DIN 3852-E: Ø 6 mm, Ø 0.6 mm, Ø 0.3 mm ¼ NPT: Ø 6 mm, Ø 0.6 mm, Ø 0.3 mm Sealings For the process connections of the following standards the listed sealing materials are available. Standard Standard Option EN 837 Copper Stainless steel DIN 3852-E NBR FKM SAE FKM - The sealings listed under "Standard" are included in the delivery. Humidity 45... 75 % relative Power supply DC 24 V Mounting position as required Page 4 of 8

Electrical connections Specifications Designation Ingress protection Wire cross-section Cable diameter Cable material Angular connector DIN 175301-803 A with mating connector IP 65 up to max. 1.5 mm 2 6... 8 mm - with solid laid cable IP 65 3 x 0.75 mm 2 6 mm PUR Angular connector DIN 175301-803 C with mating connector IP 65 up to max. 0.75 mm 2 4.5... 6 mm - with solid laid cable IP 65 4 x 0.75 mm 2 5.9 mm PUR Circular connector M12 x 1 (4-pin) without mating connector IP 67 - - - straight with solid laid cable IP 67 3 x 0.34 mm 2 4.4 mm PUR angled with solid laid cable IP 67 3 x 0.34 mm 2 4.4 mm PUR Cable outlet unshielded IP 67 3 x 0.34 mm 2 4 mm PUR OEM version, unshielded IP 67 3 x 0.14 mm 2 2.85 mm TPU The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection. Mating connectors (with and without cable) are also separately available as accessories. Cable lengths of 2 m or 5 m are available Short-circuit resistance S + vs. 0V Reverse polarity protection UB vs. 0V Insulation voltage DC 500 V Connection diagrams All connectors with solid laid cable have the same colour assignment as the unshielded cable outlet. Angular connector DIN 175301-803 A Cable outlet, unshielded U B 1 1 0V 2 2 S + - 3 U B brown brown 0V blue blue S + - black Angular connector DIN 175301-803 C Cable outlet, OEM version, unshielded U B 1 1 0V 2 2 S + - 3 U B brown brown 0V blue blue S + - black Circular connector M12 x 1 (4-pin) U B 1 1 0V 3 3 S + - 4 U B 0V S + Positive power supply terminal round Analogue output Page 5 of 8

Materials Wetted parts < 10 bar: Stainless steel 316L 10 bar: Stainless steel 316L and 13-8 PH Non-wetted parts Stainless steel 316L HNBR PA66 Approvals, directives and certificates Approvals culus OST CE conformity EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial application) Pressure equipment directive 97/23/EC For sealing materials see "Process connections" For materials for electrical connections see "Electrical connections" Pressure transmission medium < 0... 10 bar relative: Synthetic oil 0... 25 bar absolute: Synthetic oil 0... 10 bar relative: Dry measuring cell Dimensions in mm Pressure transmitters with angular connector form A with angular connector form C with circular connector M12 x 1 Weight: approx. 80 g Weight: approx. 80 g Weight: approx. 80 g with standard cable outlet, unshielded with cable outlet OEM version, unshielded Weight: approx. 80 g Weight: approx. 80 g Page 6 of 8

Process connections ¼ A DIN 3852-E 14 ½ A DIN 3852-E 17 M14 x 1.5 14 ¼ B EN 837 13 ⅜ B EN 837 16 ½ B EN 837 20 M20 x 1.5 20 9/16-18 UNF BOSS 12.06 7/16-20 UNF BOSS 12.85 Female thread Female thread L2 L3 D1 ¼ EN 837 20 13 10 Ø 25 L2 D1 ¼ NPT 20 14 Ø 25 ⅛ B EN 837 10 ⅛ NPT 10 ¼ NPT 13 ½ NPT 19 R ¼ 13 R ⅜ 15 R ½ 19 PT ¼ 13 PT ⅜ 15 PT ½ 19 For information on tapped holes and welding sockets, see Technical Information IN 00.14 at www.wika.com Page 7 of 8

Accessories and spare parts Mating connector Sealing for mating connector Sealing for process connection Mating connector Designation Order number without cable with 2 m cable with 5 m cable Angular connector DIN 175301-803 C 1439081 11225823 11250194 Angular connector DIN 175301-803 A with cable gland, metric 11427567 11225793 11250186 with cable gland, conduit 11022485 - - Circular connector M12 x 1, 4-pin straight 2421262 11250780 11250259 angled 2421270 11250798 11250232 Sealings for mating connectors Designation Order number Angular connector DIN 175301-803 A 1576240 Angular connector DIN 175301-803 C 11169479 Sealings for process connection Designation Order number Cu Stainless steel NBR FKM ¼ EN 837 11250810 11250844 - - M14 x 1.5 11250810 11250844 - - ½ EN 837 11250861 11251042 - - M20 x 1.5 11250861 11251042 - - ⅛ EN 837 11251051 - - - ¼ DIN 3852-E - - 1537857 1576534 ½ DIN 3852-E - - 1039067 1039075 Only use the accessories and spare parts listed, otherwise it could lead to the loss of the approval. Ordering information Model / Measuring range / Output signal / Power supply / Non-linearity / Temperature range / Process connection / Sealing / Electrical connection 2011 WIKA Alexander Wiegand SE & Co. K, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA Alexander Wiegand SE & Co. K Alexander-Wiegand-Straße 30 63911 Klingenberg/ermany Tel. (+49) 9372/132-0 Fax (+49) 9372/132-406 E-mail info@wika.de www.wika.de 02/2012 B