Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Similar documents
Orbipac CPF81/CPF82 and CPF81D/CPF82D

Technical Information Memosens CPS96D

Technical Information Orbipore CPS91D and CPS91

Technical Information Condumax CLS21D/CLS21

Memosens CPS96D. Technical Information

Technical Information Condumax CLS15D/CLS15

Ceramax CPS341D. Technical Information

Condumax CLS21 and CLS21D

Technical Information Memosens CLS82D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Technical Information Memosens CCS50D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Indumax CLS50D/CLS50

Condumax CLS16 and CLS16D

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Memosens New technology for contactless, inductive, digital transmission of ph signals

ph / ORP Measurement mypro CPM 431

Indumax CLS50/CLS50D. Technical Information

OPTISENS PH 8390 Technical Datasheet

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Tophit CPS491 and CPS491D

Technical Information Smartec CLD18

OPTISENS ORP 8590 Technical Datasheet

Tophit CPS491 and CPS491D

Indumax CLS54D. Technical Information

Technical Information Smartec CLD18

Signet ph/orp Electrodes

ph or ORP Transmitter

Signet ph/orp Electrodes General Purpose

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

OPTISENS PH 8100 Technical Datasheet

OPTISENS PH ph sensor. Technical Datasheet

SMARTPAT PH 1590 Technical Datasheet

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Tophit CPS441 and CPS441D

Technical Information Smartec CLD18

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Technical Information Indumax CLS54

Bulb ph and ORP Electrodes

Liquisys M CPM223/253

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

The transducer component converts the measured signal and displays the actual value.

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

IsFET sensor for ph Measurement TopHit CPS 491

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

ph/orp Measurement OPM223/253

Digital ORP sensor for the water and wastewater industry

Measuring and Controlling Unit Multronic OC

Memosens Make the most of your process with better analysis quality and lower operating costs

ABB ph/orp analyzer and probe package

Measuring and Controlling Unit Multronic

Operating Instructions Turbimax CUS71D

SMARTPAT COND 1200 Technical Datasheet

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Technical Information Liquisys M CCM223/253

SMARTPAT ORP 8510 Technical Datasheet

Digital ORP sensor for the industrial wastewater industry

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

TUpH 396RVP and 398RVP Retractable ph/orp Sensors

Sterilizable IsFET sensor for ph Measurement TopHit CPS 441

Conductivity Analyzer

Submersible pressure sensor For water and wastewater Model LW-1

Ultrasonic level transmitter, non-contact

Submersible pressure sensor For superior applications Model LF-1

Technical Information OUSBT66

Submersible pressure sensor For oils and fuels Model LF-1

Liquisys M CCM223/253

Liquisys M CPM223/253

Conductivity Transmitter

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Key Number I II III IV V _ - - _ - - _ - _, _,

Signet 9950 Dual Channel Transmitter

B Operating Instructions V1.00/EN/

Flow Measurement SITRANS F M

High-quality pressure transmitter For general industrial applications Model S-10

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

High-precision process calibrator Model CED7000

Operating Instructions Liquiline To Go CYM290

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Lines, plugs and sockets for ph, redox, conductivity and temperature sensors

XPC10 High temperature miniature pressure sensor

SMARTPAT ORP 8150 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Conductivity measurement

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

OEM radar transmitter, for aggressive media level measurement

Transcription:

TI00191C/07/EN/1.1 717156 Products Solutions Services Technical Information Orbipac CPF81D/CPF8D and CPF81/CPF8 ph/orp compact electrodes, with digital Memosens technology or analog For processes in mining industries and for treatment of industrial water and wastewater Application Flotation Leaching Neutralization Outlet monitoring Your benefits With patented KNO electrolyte bridge for better protection against electrode poisons such as S - or CN ions Optionally available with flat membrane for improved wear resistance Threaded connection NPT ¾" top and bottom for easy installation at user end Suitable for measurements within ph range 0 to 1 and within temperature range 0 to 110 C ( to 0 F) Digital ph sensors with integrated temperature sensor, analog ph electrodes with or without integrated temperature sensor Protection guard against damage Other advantages of Memosens technology Maximum process safety owing to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Predictive maintenance possible as sensor load data logged in the sensor

Orbipac CPF81D/CPF8D and CPF81/CPF8 Function and system design Measuring principle Measuring system ph measurement The ph value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the ph value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as the required reference electrode. The transmitter converts the measured voltage into the corresponding ph value using the Nernst equation. ORP measurement The ORP potential is a unit of measurement for the state of equilibria between oxidizing and reducing components of a medium. The ORP is measured using a platinum or gold electrode instead of the ph-sensitive glass membrane. Analog to the ph measurement, an integrated Ag/AgCl reference system is used as a reference electrode. A complete measuring system comprises: Sensor CPF81D, CPF81, CPF8D or CPF8 Transmitter,e.g. Liquiline CMx/R or Liquiline M CM Measuring cable, e.g. CYK10 or sensor's fixed cable 1 1 Example of a measuring system 1 Sensor CPF81D Liquiline CMx transmitter Measuring cable CYK10 A0071 Communication and data transmission Communication with the transmitter Always connect digital sensors to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. Endress+Hauser

Orbipac CPF81D/CPF8D and CPF81/CPF8 The digital sensors are able to store the following system data in the sensor. Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Calibrated slope at 5 C (77 F) (CPF81D) Calibrated zero point at 5 C (77 F) (CPF81D) Calibrated offset (CPF8D, ORP mv measuring mode) Slope as % (CPF8D, ORP % measuring mode) Temperature offset Number of calibrations Serial number of the transmitter used for the last calibration Calibration database (stores the last 8 calibrations in the Memosens head) Application data Temperature application range ph application range (CPF81D) ORP application range (CPF8D) Date of first commissioning Maximum temperature value Operating hours at temperatures above 80 C (176 F) and 100 C (1 F) Operating hours at very low and very high ph values (Nernst voltage below -00 mv, above +00 mv) Reliability Dependability Interference immunity Safety Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours under extreme measuring conditions. Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. Data security thanks to digital data transmission Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter using a non-contact connection that is free from potential interference. The result: Automatic error message if sensor fails or connection between sensor and transmitter is interrupted Immediate error detection increases measuring point availability Maximum process safety With inductive transmission of the measured value using a non-contact connection, Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. Plug-in connection free from corrosion Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. Issues concerning "symmetrical highimpedance" or "asymmetry" or an impedance converter are a thing of the past. EMC safety is guaranteed by screening measures for the digital transmission of measured values. Endress+Hauser

GN/YE Orbipac CPF81D/CPF8D and CPF81/CPF8 Input Measured values CPF81D, CPF81 ph value Temperature CPF8D, CPF8 ORP Measuring range CPF81D, CPF81 Version LH: ph 0... 1 Temperature 0 to 110 C ( to 0 F) Version NN: ph 0 to 1 (11 to 1 with reduced accuracy) Temperature 0 to 80 C ( to 170 F) CPF8D, CPF8-1500 mv to +1500 mv Please note the process operating conditions. Power supply Electrical connection CPF81D and CPF8D The electrical connection of the sensor to the transmitter takes place via special measuring cable CYK10 or CYK0. GY GND YE Com B GN WH BN Com A + Measuring cable CYK10/CYK0 A00019 CPF81 and CPF8 with TOP68 plug-in head ph/orp + Pt 100 PM Screen connection Coax BK WH GN WH YE BN Ref. ph Temp Temp. Temp. PM Measuring cable CPK9 A00668-EN Endress+Hauser

Orbipac CPF81D/CPF8D and CPF81/CPF8 CPF81 and CPF8 with fixed cable A BK BK GN/YE BN Reference ph/orp Temperature Temperature Temperature Outer screen PM / n. c.* BK BK GN WH YE GN/YE BN B GN WH YE Fixed cable connection A Fixed cable CPF81 without temperature sensor and CPF8 B Fixed cable CPF81 with temperature sensor * The PML is connected only in the case of sensor versions with an internal PML (CPF81-xxxxx) A00680-EN Installation Installation instructions 5 Flow installation A00681 6 Immersion installation with Flexdip CYA11 Make sure to follow the installation instructions in the Operating Instructions of the used assembly. A00690 Endress+Hauser 5

Orbipac CPF81D/CPF8D and CPF81/CPF8 Environment Ambient temperature Storage temperature Degree of protection NOTICE Danger of frost damage The sensor must not be used at temperatures below 0 C ( F). 0 to 50 C ( to 10 F) CPF81D, CPF8D IP 68 (10 m ( ft) head of water at 5 C (77 F) over 5 days, 1 mol/l KCl) CPF81, CPF8 with TOP68 plug-in head IP 68 (1 m (. ft) water column, 50 C (1 F), 168 h) CPF81, CPF8 with fixed cable IP 67 Electromagnetic compatibility Interference emission and interference immunity in accordance with EN 616-1:006, EN 616--:006 Memosens versions for ESD > 8 kv: reduced accuracy ±1.5 ph Process Process temperature CPF81D, CPF81 Version LH Version NN CPF8D, CPF8 0 to 110 C ( to 0 F) 0 to 80 C ( to 170 F) 0 to 80 C ( to 170 F) Process pressure 1 to 10 bar absolute, at 80 C (15 to 15 psi absolute, at 176 F) Pressure temperature load curve psi bar 15 10 10 8 80 6 50.8.5 0 15 1 0 0 0 60 100 110 60 80 100 C 176 0 10 180 0 F A0070 Glass impedance Minimum conductivity 150 MΩ at 5 C (77 F) 50 μs/cm 6 Endress+Hauser

Orbipac CPF81D/CPF8D and CPF81/CPF8 Mechanical construction Design, dimensions CPF81D, CPF8D 5 (1.8) 1 5 (1.8) 1 5 (1.8) 1 150 (5.91) 10 (5.51) 150 (5.91) 58.5 (.) 1.5 (0.9) (0.91) 5 Ø (0.87) Ø (0.87) Ø (0.87) 7 CPF81D, long shaft, protection guard 1 Memosens plug-in head NPT ¾" thread Across flats AF 6 Protection guard Dimensions in mm (inch) A0067 8 CPF81D, flat membrane 1 Memosens plug-in head NPT ¾" thread Across flats AF 6 Flat membrane A00671 9 CPF8D, short shaft, protection guard 1 Memosens plug-in head NPT ¾" thread Across flats AF 6 Platinum ring 5 Protection guard A0067 Endress+Hauser 7

Orbipac CPF81D/CPF8D and CPF81/CPF8 CPF81, CPF8 1 1 1 10 (5.51) 150 (5.91) 150 (5.91) 1.5 (0.9) (0.91) 58.5 (.) Ø (0.87) Ø (0.87) Ø (0.87) 10 A00676 CPF81 with TOP68 plug-in head, short shaft, flat membrane 1 TOP68 plug-in head NPT ¾" thread Across flats AF 6 Flat membrane Dimensions in mm (inch) 11 Fixed-cable version, short shaft, protection guard 1 Fixed cable NPT ¾" thread Across flats AF 6 Protection guard A0067 1 Fixed-cable version, long shaft, protection guard 1 Fixed cable NPT ¾" thread Across flats AF 6 Protection guard A00677 Weight 0.1 to 0.15 kg (0.6 to 0. lbs, depending on version and without cable) Materials Housing, electrode shaft PPS ph electrode (in contact with medium) ORP electrode (in contact with medium): Platinum ring Double chamber reference system: Lead-free membrane glass, suitable for process applications KNO and KCl/AgCl Process connection NPT ¾" Integrated preamplifier (optional) Structure Power supply Reference potential: cast in sensor body via integrated coin cells reference electrode With preamplifier versions, the sensor check function (SCS) of the transmitter is ineffective and should be turned off. Certificates and approvals Ex approval (optional) FM IS NI Cl. I Div.1&, Groups A-D 8 Endress+Hauser

Orbipac CPF81D/CPF8D and CPF81/CPF8 Ordering information Product page Product Configurator Scope of delivery www.endress.com/cpf81d www.endress.com/cpf81 www.endress.com/cpf8d www.endress.com/cpf8 The navigation area is located on the right of the product page. 1. Under "Device support" click "Configure your selected product". The Configurator opens in a separate window.. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device.. Export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the screen. The scope of delivery includes: Sensor in the version ordered Technical Information Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Assembly Flexdip CYA11 Immersion assembly for water and wastewater Modular assembly system for sensors in open basins, channels and tanks Product Configurator on the product page: www.endress.com/cya11 Technical Information TI00C Measuring cables CYK10 Memosens data cable For digital sensors with Memosens technology Product Configurator on the product page: www.endress.com/cyk10 Technical Information TI00118C CPK9 Terminated measuring cable for connecting analog sensors with TOP68 plug-in head Selection in accordance with product structure For more information and to order, please contact your sales office. Buffer High-quality buffer solutions from Endress+Hauser - CPY0 The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) and to standard reference material of NIST (National Institute of Standards and Technology) according to DIN 1966 by a DKD (German Calibration Service) accredited laboratory. Product Configurator on the product page: www.endress.com/cpy0 Technical buffer solutions for ORP electrodes +0 mv, ph 7, 100 ml; order no. CPY-0 +68 mv, ph 0.1, 100 ml; order no. CPY-1 Endress+Hauser 9

www.addresses.endress.com