Series CCRS-33S/CRS-33S Miniature DC 18 GHz Failsafe 2P3T Coaxial Switch

Similar documents
Series CCRS-53S/CRS-53S Miniature DC 26.5 GHz Failsafe 2P3T Coaxial Switch

Series CCRS-53S/CRS-53S Miniature DC 26.5 GHz Latching 2P3T Coaxial Switch

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCR-39S/CR-39S Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-58S/CR-58S Multi-Throw DC 26.5 GHz Normally Open Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCT-38S/CT-38S Multi-Throw DC 18 GHz/DC-22 GHz Normally Open Coaxial Switch

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCT-38S Multi-Throw DC 12 GHz, SP7T & SP8T Normally Open Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

Series CCR-48K/CR-48K Multi-Throw DC 40 GHz Normally Open Coaxial Switch

Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Latching SPDT Coaxial Switch

Series CCT-59S Multi-Throw DC-18 GHz, SP7T & SP8T Latching Coaxial Switch, Internal 50Ω Termination

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCS-32/CS-32 High Power DC 12 GHz Failsafe SPDT Coaxial Switch

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Failsafe TRANSFER Coaxial Switch

Series CCRT-53S/CRT-53S Internal 50Ω Termination DC-26.5 GHz Failsafe SPDT Coaxial Switch

Series CCT-59S/CT-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

Series CCP-47N Low PIM DC 3 GHz Latching TRANSFER Coaxial Switch

Series CCR-53S/CR-53S Miniature DC 26.5 GHz Latching SPDT Coaxial Switch

Series CCR-40K/CR-40K Miniature DC 40 GHz Latching SPDT Coaxial Switch

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Latching SPDT Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Latching TRANSFER Coaxial Switch

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Latching SPDT Coaxial Switch

Series CCS-37K/CS-37K Miniature DC 36 GHz Latching TRANSFER Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Latching TRANSFER Coaxial Switch

Series H-33S DC up to 26.5 GHz Latching SPDT Space Grade Coaxial Switch

Series H-47N DC up to 12 GHz Latching Transfer Space Grade Coaxial Switch

PAGE 1/12 ISSUE SERIES DP3T/SPDT PART NUMBER R595 XXX XXX

Failsafe Latching SPDT. Up to 8T High Power

RAMSES SERIES R 570 PART NUMBER SELECTION. SPDT up to 18 GHz. Our Most Important Connection is with You. N - TNC - BNC

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.

FMSW6097 DATA SHEET. SPDT Failsafe Electro-Mechanical Relay Switch From DC to 26.5 GHz, 20 Watts with TTL, Diodes, Indicators, SMA.

FMSW6124 DATA SHEET. Transfer Latching Electro-Mechanical Relay Switch From DC to 40 GHz, 5 Watts with Indicators, TTL, Self Cut Off, Diodes, 2.

DPDT/TRANSFER COAXIAL SWITCH

FMSW6129 DATA SHEET. SP4T Normally Open Electro-Mechanical Relay Switch From DC to 22 GHz, 20 Watts with Indicators, TTL, Diodes, SMA.

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

SEMS-4079-SP8T-SMA DATA SHEET

Standard Custom Electro-Mechanical Switches

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

Stocked Electro-Mechanical Switches

Standard Custom Electro-Mechanical Switches

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT DC-4 GHz

Standard Custom Electro-Mechanical Switches

DPDT (TRANSFER) COAXIAL SWITCH

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

HIGH REPEATABILITY, TO-5 RELAYS DPDT

Agilent 8761A/B Microwave Switches

Series HD 2A, 60Vdc, True Output Status Feedback, Short-Circuit Protected DC Solid-State Relay

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Agilent 8761A/B Microwave Switches

433 & 443 Series INTELLIGENT RELAY SP3T & SP4T IN-LINE Multithrow Switches

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ, 20 Gbps MAGNETIC-LATCHING RF RELAY

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

ponents Com ped Lum Lumped Components

SERIES 8000 LAN FOUR 1X6 TWO 1X2 Product Part Number:

CENTIGRID ESTABLISHED RELIABILITY RELAYS

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 16 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

HIGH REPEATABILITY, DC-8 GHz/20Gbps TO-5 RELAYS, DPDT

COAXIAL SWITCHES GENERAL INFORMATION WIDE FIELD OF ACTIVITY EXPERIENCE

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 18 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

SDA SMA DATA SHEET

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Series HR255/HR257 DC up to 3 GHz Magnetic Latching Space Grade DPDT Relay

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Keysight Technologies 87104/6D Multiport Electromechanical Coaxial Switches

Features. = +25 C, Vdd = +5 Vdc, 50 Ohm System. trise, tfall (10/90% RF) ton, toff (50% CTL to 10/90% RF)

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

MSW3T SP3T Surface Mount High Power PIN Diode Switch

Features. Parameter Frequency Min. Typ. Max. Units DC GHz DC GHz DC GHz DC GHz DC GHz Isolation DC - 4.

SPACE COAXIAL SWITCHES

Features. = +25 C, With 0/-5V Control, 50 Ohm System. Parameter Frequency Min. Typ. Max. Units

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 XXX 10X. (All dimensions are in mm [inches]) R 516 _ 1 0 _

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

Series HR412K/ HRS412K DC up to 1 GHz, High Shock Non-Latching Space Grade DPDT Relay

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

Features. = +25 C, With 0/-5V Control, 50 Ohm System. Parameter Frequency Min. Typ. Max. Units

Features. = +25 C, Vctl = 0/+5 Vdc, 50 Ohm System RF1 / RF2 RF1 / RF2. trise, tfall (10/90% RF) ton, toff (50% CTL to 10/90% RF)

Multi-Function Assemblies

PAGE 1/6 ISSUE Jul SERIES Micro-SPDT PART NUMBER R516 XXX 10X R 516 _ 1 0 _

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Features OBSOLETE. Isolation DC GHz db

Series HR422/ HRS422 DC up to 1 GHz Magnetic Latching Space Grade DPDT Relay

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

Parameter Min. Typ. Max. Units. Frequency Range 8-11 GHz. Saturated Output Power (Psat) 52 dbm. Input Max Power (No Damage) Psat Gain dbm

Our Experience As the world s largest manufacturer of electromechanical switches, Dow-Key Microwave Corporation is committed to providing unparalleled

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

TABLE OF CONTENTS. RF Connector/Type. Dow-Key Microwave Ordering Information. Power Chart: Standard Switches.


Transcription:

COAX SWITCHES Series CCRS-33S/CRS-33S PART NUMBER CCRS-33S CRS-33S DESCRIPTION Commercial Failsafe 2P3T, DC-18GHz Elite Failsafe 2P3T, DC-18GHz The CCRS-33S/CRS-33S is a broadband, 2P3T, electromechanical coaxial switch designed to switch a microwave signal from a common input to either of two outputs. The characteristic impedance is 50 Ohms. The switches are small with the minimum spacing that is compatible with SMA connectors, and can also be used as a SPDT switch with external terminations. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS Operating Temperature Commercial Model, CCRS-33S Elite Model, CRS-33S Vibration (MIL-STD-202 Method 214, Condition D, non-operating) Shock (MIL-STD-202 Method 213, Condition D, non-operating) Standard Actuator Life Actuator Life w/ Additional Features Connector Type Humidity (Moisture Seal) Weight 40 C to 65 C 55 C to 85 C 10 g s RMS 500 g s 5,000,000 cycles 1,000,000 cycles SMA Available 2.65 oz. (75.1g) (max.) ELECTRICAL CHARACTERISTICS Form Factor Frequency Range CCRS-33S CRS-33S Characteristic Impedance Operate Time Release Time 2P3T, break before make DC 18 GHz DC 18 GHz 50 Ohms 10 ms (max.) 10 ms (max.) Actuation Voltage Available 12 15 24 28 V Actuation Current, max. @ ambient 420 350 280 200 ma PERFORMANCE CHARACTERISTICS Frequency DC 6 GHz 6 12 GHz 12 18 GHz Insertion Loss, db, max. 0.1 0.2 0.3 Isolation, db, min. 85 80 75 VSWR, max. 1.1:1 1.2:1 1.3:1 PART NUMBERING SYSTEM CCRS-33 S 1 C - T ** Series Connectors Options Actuator Type Actuator Voltage Connector S: SMA Female Actuator Voltage 1: 28 Vdc Failsafe 2: 15 Vdc Failsafe 3: 12 Vdc Failsafe 4: 24 Vdc Failsafe Actuator Type O: Standard Contacts C: Indicator Contacts **SEE PARTS LIST ON PAGE 8 Options T: TTL Drivers with Diodes D: Transient Suppression Diodes M: Moisture Seal S: 9 Pin D-Sub Connector For other options, contact factory. 2012 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCRS-33S/CRS-33S Page 1

Series CCRS-33S/CRS-33S COAX SWITCHES SCHEMATICS AND MECHANICAL OUTLINE 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250ºC FOR NO MORE THAN 5 SEC H = 1.75 STD & Indicator Model H = 1.90 All OTHER Models Indicators TTL Analog 1 6 -S OPTION 9-PIN D-SUB CONNECTOR (EXAMPLE: CCRS-33S10-S) 9 PIN D-SUB PINOUT FOR FAILSAFE 2P3T OPTIONS Pin Basic Indicators TTL No. Indicators & TTL 1 + + 2 - - 3 Common Common 4 1 1 5 6 Vsw Vsw 7 A A 8 B B 9 C C TRUTH TABLE (with TTL option) Logic Input RF Path Indicator (if applicable) 1 0 2&3 4&5 B & C 1 1&2 3&4 A & C CCRS-33S/CRS-33S Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2012 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCRS-33S/CRS-33S TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES Insertion Loss ( DC-6 GHz ) Insertion Loss ( 6-12 GHz ) Insertion Loss (db) 0.0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0 0 1 2 3 4 5 6 Insertion Loss (db) 0.0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0 6 7 8 9 10 11 12 Insertion Loss ( 12-18 GHz ) Insertion Loss (db) 0.0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0 12 13 14 15 16 17 18 RF NOTES 2012 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCRS-33S/CRS-33S Page 3

Series CCRS-33S/CRS-33S COAX SWITCHES TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES 0 Isolation ( DC-6 GHz ) 0 Isolation ( 6-12 GHz ) -20-20 -40-40 Isolation (db) -60-80 -100 Isolation (db) -60-80 -100-120 -120-140 0 1 2 3 4 5 6-140 6 7 8 9 10 11 12 0 Isolation ( 12-18 GHz ) -20 Isolation (db) -40-60 -80-100 -120-140 12 13 14 15 16 17 18 RF NOTES CCRS-33S/CRS-33S Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2012 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCRS-33S/CRS-33S TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES 2.0 VSWR ( DC-6 GHz ) 2.0 VSWR ( 6-12 GHz ) 1.9 1.9 1.8 1.8 1.7 1.7 VSWR 1.6 1.5 1.4 VSWR 1.6 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1.0 0 1 2 3 4 5 6 1.0 6 7 8 9 10 11 12 2.0 VSWR ( 12-18 GHz ) VSWR 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 12 13 14 15 16 17 18 RF NOTES 2012 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCRS-33S/CRS-33S Page 5

Series CCRS-33S/CRS-33S COAX SWITCHES TYPICAL POWER PERFORMANCE CURVE Power Handling vs. Frequency 3000 2000 1000 800 600 Power (W) 400 300 200 100 80 60 STANDARD SMA SWITCHES 40 30 20 10.1.2.3.4.6.8 1 2 4 6 8 10 18 Frequency GHz Estimates based on the following reference conditions: Ambient temperature of 40 C or less Sea level operation Load VSWR of 1.20:1 maximum No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. CCRS-33S/CRS-33S Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2012 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCRS-33S/CRS-33S GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the reverse EMF spike generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MIL- STD-1285 Paragraph 5.2.5 and consist of four digits. The fi rst two digits defi ne the year and the last two digits defi ne the week of the year (YYWW). Thus, 1032 identifi es switches that passed through fi nal inspection during the 32nd week of 2010. Failsafe A failsafe switch reverts to the default or failsafe position when actuating voltage is removed. This is realized by a return spring within the drive mechanism. This type of switch requires the continuous application of operating voltage to select and hold any position. (Multi-position switches are normally open with no voltage applied). Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specifi ed, the maximum indicator contact rating is 30 Vdc, 50 ma, or 1.5 Watts into a resistive load. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as worst case at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: I A I T = [1 +.00385 (T-20)] Where: I T = Actuator current at temperature, T I A = Room temperature actuator current see data sheet T = Temperature of interest in C Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fi elds. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fi elds should be limited to a fl ux density of less than 5 Gauss. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specifi ed in db below the input power level. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. 2012 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCRS-33S/CRS-33S Page 7

Series CCRS-33S/CRS-33S COAX SWITCHES FAILSAFE CCRS-33S/CRS-33S PART NUMBER LIST PART NO. PART NO. 1 CCRS-33SXC 43 CRS-33SXO-MS 2 CCRS-33SXC-D 44 CRS-33SXO-S 3 CCRS-33SXC-DM 45 CRS-33SXO-T 4 CCRS-33SXC-DMS 46 CRS-33SXO-TM 5 CCRS-33SXC-DS 47 CRS-33SXO-TMS 6 CCRS-33SXC-M 48 CRS-33SXO-TS 7 CCRS-33SXC-MS 8 CCRS-33SXC-S 9 CCRS-33SXC-T 10 CCRS-33SXC-TM 11 CCRS-33SXC-TMS 12 CCRS-33SXC-TS 13 CCRS-33SXO 14 CCRS-33SXO-D 15 CCRS-33SXO-DM 16 CCRS-33SXO-DMS 17 CCRS-33SXO-DS 18 CCRS-33SXO-M 19 CCRS-33SXO-MS 20 CCRS-33SXO-S 21 CCRS-33SXO-T 22 CCRS-33SXO-TM 23 CCRS-33SXO-TMS 24 CCRS-33SXO-TS 25 CRS-33SXC 26 CRS-33SXC-D 27 CRS-33SXC-DM 28 CRS-33SXC-DMS 29 CRS-33SXC-DS 30 CRS-33SXC-M 31 CRS-33SXC-MS 32 CRS-33SXC-S 33 CRS-33SXC-T 34 CRS-33SXC-TM 35 CRS-33SXC-TMS 36 CRS-33SXC-TS 37 CRS-33SXO 38 CRS-33SXO-D 39 CRS-33SXO-DM 40 CRS-33SXO-DMS 41 CRS-33SXO-DS 42 CRS-33SXO-M * X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc) CCRS-33S/CRS-33S Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2012 TELEDYNE COAX SWITCHES