Damping of Sub-synchronous Resonance and Power Swing using TCSC and Series capacitor

Similar documents
COORDINATEDD CONTROL OF HYBRID SERIES CAPACITIVE COMPENSATION FOR DAMPING WIND FARM

Dynamic Modeling of Thyristor Controlled Series Capacitor in PSCAD and RTDS Environments

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

ELEMENTS OF FACTS CONTROLLERS

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Power Control Scheme of D-Statcom

Chapter 10: Compensation of Power Transmission Systems

Power Flow Control/Limiting Short Circuit Current Using TCSC

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Voltage Control and Power System Stability Enhancement using UPFC

Comparison of FACTS Devices for Power System Stability Enhancement

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Damping of Sub synchronous Resonance Using SSSC Based PWM Hysteresis Controller

A.V.Sudhakara Reddy 1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar 3

Design and Control of Small Scale Laboratory Model of a Thyristor Controlled Series Capacitor (TCSC) to Improve System Stability

PERFORMANCE COMPARISON OF POWER SYSTEM STABILIZER WITH AND WITHOUT FACTS DEVICE

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

I. INTRODUCTION. Keywords:- FACTS, TCSC, TCPAR,UPFC,ORPD

Power Quality Improvement using Shunt Passive Filter

Address for Correspondence

Investigation of D-Statcom Operation in Electric Distribution System

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Improvement of Transient stability in Power Systems with Neuro- Fuzzy UPFC

Transient Stability Improvement of Multi Machine Power Systems using Matrix Converter Based UPFC with ANN

Power System Oscillations Damping and Transient Stability Enhancement with Application of SSSC FACTS Devices

Brief Study on TSCS, SSSC, SVC Facts Device

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

International Journal of Advance Engineering and Research Development

Designing Of Distributed Power-Flow Controller

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Power Quality enhancement of a distribution line with DSTATCOM

Dynamic Phasors for Small Signal Stability Analysis

Transient Stability Improvement Of IEEE 9 Bus System With Shunt FACTS Device STATCOM

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

IMPORTANCE OF VSC IN HVDC

Power System Dynamics Enhancement Through Phase Unbalanced and Adaptive Control Schemes in Series FACTS devices

A MPPT ALGORITHM BASED PV SYSTEM CONNECTED TO SINGLE PHASE VOLTAGE CONTROLLED GRID

Optimal Placement of Shunt Connected Facts Device in a Series Compensated Long Transmission Line

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Considerations for the Application of Thyristor Controlled Series Capacitors to Radial Power Distribution Circuits

Power Quality improvement of a three phase four wire system using UPQC

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Fuzzy PID Controller Enhancement of Power System using TCSC

DAMPING POWER SYSTEM OSCILLATIONS USING AN SSSC- BASED HYBRID SERIES CAPACITIVE COMPENSATION SCHEME

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Interline Power Flow Controller: Review Paper

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Determination of Optimal Account and Location of Series Compensation and SVS for an AC Transmission System

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

BIDIRECTIONAL SOFT-SWITCHING SERIES AC-LINK INVERTER WITH PI CONTROLLER

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

Comparison and Performance Analysis of FACTs Controller in System Stability

ISSN Vol.04,Issue.16, October-2016, Pages:

Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multimachine System

EVALUATION OF A NEW MODEL FOR UPFC OPERATING AS IMPEDANCE COMPENSATION APPLIED TO MULTI- MACHINE SYSTEMS WITH NONLINEAR LOAD

A DYNAMIC POWER FLOW CONTROLLER FOR POWER SYSTEM STABILITY IMPROVEMENT AND LOSS REDUCTION

A Comprehensive Approach for Sub-Synchronous Resonance Screening Analysis Using Frequency scanning Technique

PRECISION SIMULATION OF PWM CONTROLLERS

Available ONLINE

Power Flow Control in HVDC Link Using PI and Ann Controllers

Design And Analysis Of Control Circuit For TCSC FACTS Controller

Digital Simulation of Thyristor Controlled Interphase Power Control Technology (TC- IPC) to limit the fault currents

Voltage-Current and Harmonic Characteristic Analysis of Different FC-TCR Based SVC

Power Quality Improvement in Distribution System Using D-STATCOM

Volume I Issue VI 2012 September-2012 ISSN

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Mitigation of Voltage Sag and Swell Using Distributed Power Flow Controller

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Power Quality Enhancement and Mitigation of Voltage Sag using DPFC

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

Transcription:

Damping of Sub-synchronous Resonance and Power Swing using TCSC and Series capacitor Durga Prasad Ananthu Assistant Professor, EEE dept. Guru Nanak Dev Engg College, Bidar adp.ananthu@gmail.com Rami Reddy Mannem M.Tech Scholar, EEE Dept. SVEC, Suryapet- INDIA ramreddy.mannem@gmail.com Abstract The proposed series capacitive compensation scheme is effective in damping power swing as well as sub synchronous resonance oscillations. The combination of fixed series capacitor and TCSC is termed as a Hybrid technique. In this paper, the effectiveness of a hybrid series capacitive compensation scheme in damping power system oscillations is evaluated. In this scheme, where two phases are compensated by fixed series capacitor (C) and the third phase is compensated by a TCSC in series with a fixed capacitor (Cc). The effectiveness of the scheme in damping power system oscillations for various network conditions, namely different system faults and tie-line power flows is evaluated using the EMTP-RV time simulation program. Key Words FACTS Controllers, series compensation, thyristor controlled series capacitor. ***** 1 INTRODUCTION The transmission network in the INDIA is being wider due to an increasing demand for power transmission combined with the difficulty in approving new lines. Series compensation of transmission lines is a widely-used method to improve the effective capacity of the transmission system, thus avoiding the need to build new lines in many parts of the network. Insertion of capacitive reactance in series with line s inherent inductive reactance lowers the total effective impedance of the line and thus virtually reduces its length. As a result both angular and voltage stability in the power system gets improved. However, series compensation of lines creates the risk of torsional oscillations between the electrical network and generators. These oscillations are referred to as sub-synchronous resonance (SSR) since they typically occur at sub-synchronous frequencies that means frequencies less than nominal 50Hz or 60 Hz frequency. Because of SSR, generators will get damage. During the 90 ies the Thyristor Controlled Series Capacitor (TCSC) was being introduced. In this apparatus a thyristor controlled, inductive branch has been connected as an add-on in parallel with the series capacitor bank (Fig. 1.). Fig.1 TCSC main circuit When a forward-biased thyristor is fired the capacitor will be partially discharged through the LC circuit constituted by the thyristor controlled inductive branch and the capacitor bank. The circulating current pulse passes through the capacitor in phase with the line current. It creates an additional voltage across the capacitor in excess of the voltage, which is caused by the line current. The increased voltage at a given line current amplitude is perceived by the transmission system as if the inserted capacitive reactance had been increased or boosted by the action of the thyristor valves. The generic waveform of the TCSC is shown in Fig. 2 It was recognized early that the characteristics of the TCSC with respect to SSR differed completely from that of a passive, fixed series capacitor. 1903

yield a resultant compensation equal to the other phases. Thus, the phase balance is maintained t the power frequency while at any other frequency, a phase imbalance is created. To further enhance power oscillations damping, the TCSC is equipped with a supplementary controller. The proposed series compensation scheme can be explained mathematically as: 1) At the power frequency, the series reactances between buses X and Y in Fig. 1,in phase a, b and c are given by Fig. 2. Generic waveforms for the TCSC. From top to bottom: line current, valve current, capacitor voltage, apparent reactance The latter reveals a capacitive reactance, which is inversely proportional to the frequency. Accordingly it tends towards infinity at zero frequency (DC). The apparent reactance of the TCSC, in contrast, decreases with frequency and gets zero at zero frequency (DC). The reason for this dissimilarity is that the TCSC reacts on an injected sub synchronous line current component by modulating the thyristor current in the inductive branch. This influences the sub synchronous current passing through the capacitor, which determines the sub synchronous voltage across the TCSC. The algorithm that has been selected for the thyristor triggering control plays the main role in forming the characteristics of the TCSC with respect to SSR behaviour. However, also the regulators executing synchronization and boost control do have an impact on the TCSC s SSR properties. The thyristor-controlled series capacitor (TCSC) is one of the most effective countermeasures in practice due to its natural mitigating effect, as well as its ability to damp SSR through a controller. However, the strong dependency between network parameters and generator data plus the complex function of the TCSC require comprehensive studies prior to the installation of a TCSC into the transmission system. Fig. 3 shows the series capacitive compensation scheme. It is a hybrid series compensation scheme, where the series capacitive compensation in one phase is created using a single-phase TCSC in series with a fixed capacitor (C c ), and the other two phases are compensated by fixed series capacitors(c). The TCSC control is initially set such that its equivalent compensations at the power frequency combined with the fixed capacitor Where is the effective capacitive reactance of the TCSC at the power frequency such that 2) During any other frequency,f e The first terms in (2) and (3) are different because of the difference in frequency. The third term in (3) represents the change in the effective capacitive reactance of the TCSC due to the action of the TCSC supplementary controller. Fig. 3 A Schematic Diagram of the hybrid series compensation scheme This scheme would, definitely, be economically attractive when compared with a full three-phase TCSC which has been used/proposed for power oscillations damping. Furthermore reducing the number of thyristor valves to one third will also have a positive impact on system reliability. The effectiveness of the scheme in damping power swings and sub synchronous resonance oscillations is reported in [2], [3]. This paper evaluates the effectiveness of the scheme in damping power system oscillations. Time domain simulations were conducted on a benchmark network using the EMTP-RV. 1904

II.TEST SCHEME To demonstrate the effectiveness of the proposed scheme in power system oscillations damping, the system shown in Fig. 4 is adopted as a test scheme. It consists of three large generating stations (G 1, G 2 and G 3 ) supplying two load centers (S 1 and S 2 ) through five 500 kv transmission lines. The two double-circuit transmission lines L 1 and L 2 are series compensated with fixed capacitor banks located at the middle of the lines. The compensation degree of L 1 and L 2 is 50%. The compensation degree is defined as the ratio (X C /X L )* 100% for fixed capacitor compensated phases and (X Cc +X TCSC )/X L * 100% for the hybrid compensated phase. The total installed capacity and peak load of the system are 4500 MVA and 3833 MVA respectively. Shunt capacitors are installed at buses 4 and 5 to maintain their voltages within 1±0.05 p.u. Two loading profiles designated as Load Profiles A and B are considered in the investigations of this paper. In Load Profile A, S 1 = 1400 + j200 MVA and S 2 = 2400 + j300 MVA while in Load Profile B, S 1 = 2000 + j200 MVA and S 2 = 1800 + j300 MVA. The power flow results for the bus voltages and the line real power flows of the system for these two loading profiles are shown in the Appendix. The EMTPRV is used as the simulation study tool. III. MODELING OF THE SINGLE-PHASE TCSC The single-phase TCSC is modeled in the EMTP- RV as a single module using an ideal thyristor pair and an RC snubber circuit as shown in Fig. 5. A Phase Locked Loop (PLL) is used to extract phase information of the fundamental frequency line current, which will be used to synchronize TCSC operation. The thyristor gating control is based on the Synchronous Voltage Reversal (SVR) technique [4]. The TCSC impedance is measured in terms of a boost factor kb, which is the ratio of the apparent reactance of the TCSC seen from the line to the physical reactance of the TCSC capacitor bank. A positive value of kb is considered for capacitive operation. A low-pass filter based estimation algorithm is used to estimate the voltage and the current phasors. A boost measurement block performs complex impedance calculations for the boost factor of the TCSC as kb = Imag{VˆC / IˆC }/ X CTCSC, where, VˆC and IˆC are the estimated phase voltage and current and X CTCSC is the capacitive reactance of the TCSC capacitor branch at the fundamental frequency. Fig. 4 Test Scheme A proportional-integral (PI) control based boost level controller is implemented to control the TCSC boost level to the desired value by adjusting the instant of the expected capacitor voltage zero crossing. The integral part of the controller helps in removing the steady state errors. The controller parameters were determined by performing repeated time domain simulations for the different operating conditions. This algorithm uses the difference between the actual boost level and the reference boost level (err) shown in Fig. 5 as an objective function. The algorithm starts with arbitrary initial values for the control parameters and calculates the values of the objective function each time. The control parameters are incremented for the next iteration and the procedure is repeated until the objective function approaches a minimum value (below a threshold value). The procedure described above is widely used by industry for tuning of controller parameters. The multiple simulations run based tuning procedure similar to the above was reported in [5]-[6]. In Fig. 5, D(t) is a supplemental signal generated from an m-stage lead-lag compensation based controller. As the real power flow in the transmission line is proportional to the inverse of the total line reactance, the power swing damping can be achieved by properly modulating the apparent TCSC reactance through this controller. The supplemental controller input (stabilizing) signals could be 1905

local (e.g. real power flows) or remote (e.g. load angles or speed deviations of remote generators). If a wide-area network of Synchronized Phasor Measurement (SPM) units is available, then the remote signals can be downloaded at the controller in real time without delay. Local signals are generally preferred over remote signals as they are more reliable since they do not depend on communications. IV. TESTSIMULATIONS This section demonstrates the capability of the proposed hybrid series compensation scheme in power system oscillations damping. For this purpose, the scheme is assumed to be placed in the test scheme replacing the fixed series capacitive compensation in L 1 and L 2. Moreover, it is assumed that each TCSC provides 50% of the total capacitive compensation and the disturbance is a threecycle, three-phase fault at bus 4. Furthermore, the performance of the scheme is compared with only fixed capacitor compensation (Fixed C). TEST CASE 1: Fig. 5. Block diagram of a TCSC controller. In Fig. 5, kb ref is the TCSC boost level set point. The Synchronous Voltage Reversal block solves for angle γ from the non-linear relation, u CZ = X o i LM [λγ tan(λγ )], where u CZ is the estimated capacitor voltage at the desired instant when the capacitor voltage zero crossing occurs, i LM is the measured value of the line current i L, X 0 is the TCSC capacitor reactance at the TCSC resonance frequency, λ is the ratio between the TCSC resonance frequency and the system fundamental frequency and γ is the angle difference between the firing time and the voltage zero-crossing. The value of γ is used to calculate the exact firing instants of the individual thyristors. The non-linear relationship between the boost factor and the thyristor firing angle α is shown in Fig. 6 In this test four different combinations of stabilizing signals (tabulated in Table I) are examined in order to determine the combination that would result in the best system transient time responses. The final results of the time-domain simulation studies (controllers tuning) are shown in Fig. 9 which illustrates the generator load angles, measured with respect to generator 1 load angle, during and after fault clearing. Fig. 7 Simulation diagram of Fixed Compensatin It can also be seen from Fig. 9 that the best damping of the relative load angle responses are achieved with the δ 21 - δ 21 combination. The second best damped responses are obtained with the δ 31 -δ 21 combination. These results should be expected due to the direct relationship between the relative load angles and the generators that yield the problem. It can also be seen from Fig. 9 that the worst damped responses are obtained with P L1 - δ 21 combination which results also in the increase of the first swings. Fig. 6. TCSC boost factor as a function of the thyristor firing angle α. 1906

TABLE I The Four Examined Combinations Of Stabilizing Signals For Test Case 1 Combination Each TCSC in L1 Each TCSC in L2 1 δ 21 δ 21 2 δ 31 δ 21 3 δ 31 P L2 4 P L1 δ 21 TEST CASE 2: In this case, δ 21 is used as the supplementary controllers stabilizing signal. Fig. 10 illustrates the generator load angles, measured with respect to generator 1 load angle, during and after fault clearing. It can be seen from Fig. 10 that, at this loading profile, the hybrid singlephase-tcsc scheme provides again a better damping performance to system oscillations compared to fixed capacitor compensation. It is observed, however, that there Fig. 9 Generator load angles, measured with respect to generator 1 load angle, during and after clearing a three-phase fault at bus 4 (Test case A). is a slight increase in the first swing of δ 21 Fig. 10. Generator load angles, measured with respect to generator 1 load angle, during and after clearing a three-phase fault at bus 4 (Test case 2). Fig. 8 Simulation diagram of the hybrid TCSC compensation scheme. TEST CASE 3: In this case Any of the four signals, δ 21, δ 31, P L1 and P L2 contains the system s two natural modes of oscillations and can be used to add damping to these modes as it has been demonstrated in Test Case I. it is a dual channel controller, in this The sum of two properly selected signals, however, should result in a more effective damping. The reason is that the two natural modes of oscillations are, in general, not in phase. A dual-channel controller would adjust separately the gain and phase of each mode of oscillations and, thus, provides a better damping. The results shows that the best and second best damped responses are obtained with δ 21 P L1 and δ 31 P L2 Fig.11 illustrates the generator load angles, measured with respect to generator1 load angle, during and after fault clearing. These results (in red color) are compared to the hybrid case of Fig. 10 1907

V. CONCLUSION The paper presents the application of a new hybrid series capacitive compensation scheme in damping sub synchronous resonance (SSR) and power swing. The hybrid series capacitive compensation scheme is more effective in damping power system oscillations compared to a fixed series capacitor. The effectiveness of the presented scheme in damping power system oscillations is obtained through simulations of case studies on a test scheme. Fig. 11. Generator load angles, measured with respect to generator 1 load angle, during and after clearing a three-phase fault at bus (Test case 3,dual-channel controller). Fig. 12 illustrates the three-phase voltages, V X-Y, across the hybrid single-phase-tcsc compensation scheme (installed in L1 and the controllers are Pair 2) during and after clearing the fault. The system phase imbalance during the disturbance is clearly noticeable especially in phase C. REFERENCES [1] Narain G. Hingorani and Laszlo Gyugyi, Understanding FACTS, Concepts and Technology of Flexible AC Transmission Systems, IEEE Press, 2000. [2] E.V. Larsen, J.J. Sanchez-Gasca and J.H. Chow, Concepts for Design of FACTS Controllers to Damp Power Swings, IEEE Transactions on Power Systems, Vol. 10, No. 2, May 1995, pp. 948-95 [3] B. Chaudhuri and B. Pal, Robust Damping of Multiple Swing Modes Employing Global Stabilizing Signals with a TCSC, IEEE Transactions on Power System, Vol. 19, No. 1, February 2004, pp. 499 506. [4] Lennart Ängquist, Synchronous Voltage Reversal Control of Thyristor Controlled Series Capacitor, Royal Institute of Technology, TRITAETS- 2002-07, ISSN 1650-674X [5] A.M. Gole, S. Filizadeh, R.W. Menzies and P.L. Wilson, Optimization-enabled Electromagnetic Transient Simulation, IEEE Transactions on Power Delivery, Vol. 20, No.1 January 2005, pp 512 518 [6] R. Majumder, B.C. Pal, C. Dufour and P. Korba, Design and Real-Time Implementation of Robust FACTS Controller for Damping Inter-Area Oscillation, IEEE Transactions on Power Systems, Vol. 21, No.2, May 2006, pp. 809-816. BIOGRAPHY M RAMI REDDY completed B.Tech degree from JNTU Hyderabad and doing his M.Tech in Power Electronics from S.V Engg. College /JNTU Hyderabad. He worked for Sagar Cements as a Sr.Engineer and his area of interests in Power Electronics and Drives, PLC automation. A DURGA PRASAD, completed B.Tech degree from JNTU Hyderabad And obtained his M.Tech Power Electronics degree from JNTU Hyderabad. Currently he is working for Guru Nanak Dev Engineering College as an Assistant Professor and his area of interest in Renewable energy sources. Fig.12 Phase voltages, V X-Y across the hybrid single-phase-tcsc scheme on L 1 during and after clearing a three-phase fault at bus 4 1908