Synchronous Measurement, Control, & Protection of Electric Power Systems. Dr. Edmund O. Schweitzer, III February 29, 2012

Similar documents
RELIABILITY: Our Advantages, Challenges, and Opportunities

Our Cyber Security History and Future

Synchrophasors and the Smarter Grid

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Anti-Islanding Today, Successful Islanding in the Future

Measurement tools at heart of Smart Grid need calibration to ensure reliability

Wide-Area Measurements to Improve System Models and System Operation

State Estimation Advancements Enabled by Synchrophasor Technology

System Protection Schemes in Power Network based on New Principles

Use of Synchrophasors to Detect Control System and Circuit Breaker Reclosing Issues

Testing and Validation of Synchrophasor Devices and Applications

Considerations for the Application of Synchrophasors to Predict Voltage Instability

GRID RELIABILITY MONITORING

Practical PMU Applications for Utilities

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

SDG&E Transmission Synchrophasor Project Update

Phasor Measurements for Blackout Prevention

Linear State Estimation

Smart Grid Where We Are Today?

Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

Wide Area Visualization & SynchroPhasors

Adamantios Marinakis, Scientist, 12 th IEEE SB Power Engineering Symposium, Leuven, Enhancing Power System Operation with WAMS

Using Synchrophasors for Controlled Islanding A Prospective Application in the Uruguayan Power System

In addition to wide-area monitoring systems, synchrophasors offer an impressive range of system benefits, including:

ROSE - Real Time Analysis Tool for Enhanced Situational Awareness

Application of Synchrophasors in Power Plants Incorporated with Condition Monitoring Systems K P C L

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

Monitoring and Situational Awareness Conference. Improving EMS Reliability Denver, CO September 18, 2013

Advanced Real-Time Synchrophasor Applications

Turning Synchrophasor Data Into Actionable Information

Wide Area Monitoring with Phasor Measurement Data

A Novel Online Wide Area Voltage Stability Control Algorithm for Power Systems: RT-VSMAC Tool

Synchrophasors for Distribution Applications

Transmission Protection Overview

Use of the Power System Outlook (PSO) and SMART 1 Programs to View PSLF Dynamic Simulation Data Files

DISTRIBUTION STATE ESTIMATION

March 27, Power Systems. Jaime De La Ree ECE Department

Use of Synchronized Phasor Measurements for Model Validation in ERCOT

EH2741 Communication and Control in Electric Power Systems Lecture 2

REDESIGN OF THE ESKOM CAPE CORRIDOR OUT-OF-STEP TRIPPING SCHEME. A Bartylak ESKOM System Operator

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

International Collaboration in Synchronized Measurement Experiment in Russia

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

Microgrid Islanding with a Battery Energy Storage System (BESS) Gabriel Haines

TEAMS Competition 2014

Phase Angle Monitoring:

ESB National Grid Transmission Planning Criteria

Protective Relay Synchrophasor Measurements During Fault Conditions

Task Force on Synchrophasor Protection Applications NASPI Engineering Analysis Task Team Matthew Rhodes 3/22/16

A Software Tool for Real-Time Prediction of Potential Transient Instabilities using Synchrophasors

Wide Area Monitoring Network Stability & Synchrophasors. GE Consumer & Industrial Multilin

PMU Application in Out-of-Step Protection

Experiences of Using Synchrophasors at Duke Energy

Accurate Synchrophasor Estimation to Support the Islanding Maneuver of Active Distribution Networks

Suggested reading for this discussion includes the following SEL technical papers:

Engineering Thesis. The use of Synchronized Phasor Measurement to Determine Power System Stability, Transmission Line Parameters and Fault Location

Communication Aided Tripping. Common Methods, Schemes and Considerations

Fault Location Using Sparse Wide Area Measurements

openpdc in the Control Center

Adaptive Distance Protection for Microgrids Lin, Hengwei; Zapata, Josep Maria Guerrero; Quintero, Juan Carlos Vasquez; Liu, Chengxi

POWER SYSTEM BACKUP PROTECTION USING SYNCHRONIZED PMU

SynchroPhasor Roadmap

Protection & Control Challenges with Distributed Generation

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

Transmission System Phase Backup Protection

Application Example Document ID: SA Rev. - September 24, 2004

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

SEL-311C TRANSMISSION PROTECTION SYSTEM

Oscillatory Stability: Extended Range & Enhanced Source Location

POWER systems are being operated closer to the stability

Identifying Long Term Voltage Stability Caused by Distribution Systems vs Transmission Systems

A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection. Steve T. Watt, Shankar V. Achanta, and Peter Selejan

Contingency Analysis using Synchrophasor Measurements

Best Assignment of PMU for Power System Observability Y.Moses kagan, O.I. Sharip Dept. of Mechanical Engineering, Osmania University, India

Locating Faults by the Traveling Waves They Launch

A Topology-based Scheme for Adaptive Underfrequency Load Shedding

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

Introduction to micropmu. PSL Australasian Symposium 2017 September 29 Thomas Pua Product Engineer

Catastrophic Relay Misoperations and Successful Relay Operation

Case Study of a Multiterminal Generation Interconnect Scheme

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

SYNCHRONIZED PHASOR MEASUREMENT TECHNIQUES. A.G. Phadke

Using Protective Relays for Microgrid Controls

Line Protection Roy Moxley Siemens USA

UNIT II: WIDE AREA MONITORING SYSTEM

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/

Distance Relay Response to Transformer Energization: Problems and Solutions

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Risk of unintentional islanding in the presence of multiple inverters or mixed generation types

A short introduction to Protection and Automation Philosophy

New Standards for Test and Calibration of Phasor Measurement Units

Inverter-Based Resource Disturbance Analysis

EE Lecture 14 Wed Feb 8, 2017

ANALYTICAL AND SIMULATION RESULTS

Power System Stability. Course Notes PART-1

A. df/dt Measurement principle by relays

Surviving and Operating Through GPS Denial and Deception Attack. Nathan Shults Kiewit Engineering Group Aaron Fansler AMPEX Intelligent Systems

Postprint. This is the accepted version of a paper presented at IEEE PES General Meeting 2016, Boston.

Operationalizing Phasor Technology. Model Validation. Webinar. Ken Martin. March 4, Presented by. Page 0

Transcription:

Synchronous Measurement, Control, & Protection of Electric Power Systems Dr. Edmund O. Schweitzer, III February 29, 2012 Copyright SEL 2011

The Future of Power Systems No Blackouts New Sources Better Control Faster Tripping Islanding State Measurement Distributed Generation Intermittent Sources Innovations Fast Remedial Action Wide-Area Control Secure Solutions must be: efficient, low-cost, robust, reliable

Building Blocks and Solutions Measure, control, protect Process information anywhere Dependable, deterministic, secure communications utility rated Reliable, redundant precise time Real-time wide-area solutions for control, protection, and automation of electric power systems

Synchronous measurement, control, and protection capabilities are in your relays, meters, VRCs, TODAY, for free.

SEL Synchrophasors Are Everywhere, and Growing Every Day! Western Interconnection >40,000 units Eastern Interconnection >125,000 units Texas Interconnection >18,000 units

RTAC & SVP: Relay-Speed Processing, Anywhere State Equations: Stability, Thermal Phasor Math: Self-Checks, Interpolation

Generator relays will directly measure δ Z + δ - E V, I a S a ' Generator N E δ IZ V

Rotor δ Test System

Communications for Critical Infrastructure Secure, 5ms healing, reliable, redundant, 0.5µs absolute time, deterministic. 1 2 7 ms 3 1 2 3 7 ms 12 ms

Relay SVP ICON SVP Relay t E t E t E SVP PMU

Radios for POTT and Network Backup Network RTAC X RTAC RTAC Radio Radio Radio Radio Relay Relay Relay Relay

GPS Time Is Not Guaranteed! Jamming or interference (NAVWAR) Equipment failure DoD Control Solar flares On December 6, 2006, a solar flare created an unprecedented intense solar radio burst causing large numbers of receivers to stop tracking the GPS signal. -- NOAA Press Release

Reliable and Redundant Precise Time Satellites: GPS is great when available ICON networks +/- 0.5µs of all nodes with or without GPS Rubidium and cesium standards WWVB? You can build systems today that enjoy the precision of GPS and provide wide-area synchrony even when GPS is lost.

We Must Operate, Control, Protect Our Wide-Area Systems Better Quicker loop times Cycles or seconds vs minutes Automation / operators State-based control Measure the state Drive the system to desired state Distributed control/successful islanding

CFE (Mexico): Generation Shedding 400 kv 400 kv National System A3130 A3030 A3T60 900 MW Chicoasen (MMT) Sabino (SSB) Angostura (ANG) Tapachula City 400 kv 115 kv Network Southern Region Load Synchrophasors

Georgia: Tiblisi Relies on Enguri Dam Line Loss Requires Load Shedding Enguri HPP Copyright SEL 2011

Florida Power & Light Anti-islanding T Angle Frequency Slip Acceleration SVP Relay Relay DG

Directly Measure the State V 1 Network Synchronized Data V 2... V n Sub 1 Sub n Detect bad data RTAC... SVP Average measurements V 1 Determine topology V n Calculate V at adjacent stations: V = V + ZI

Complete State Vector, S Every Location Gets the State Vector Lateral Communications: ICON, Radio V j V k V l = S V m V n V 1. V j = V k V l V m V n V j j k l m n... N = j + k + l + m + n

State Interpolation or Linear Estimation Line 4 Line 1 V L4 Sub 1 V L1 Z 12 I 1 V 2 Sub 2 V L3 Line 3 V L2 Line 2 V 1 = ¼ V L1 + V L2 + V L3 + V L4 if all breakers closed and if all voltages about the same V 2 = V 1 + Z 12 I 1

Determining Wide-Area Voltages Use Local V and I to Determine Remote V 1 2 3 4 5 6 7 8 9 V2 = V1 + Z12 I12

Voltage Stability Assessment System SVP Computer Time Alignment Voltage Collapse Prediction Visualization and Control Automatic Control PMUs Major Interconnection Weak Buses Eskom Network

Governor Mode Control Utility Power System Plant Distribution System Abbott Generator Relay Frequency and Angle Measurements Across Relay-to-Relay Logic Communications Relay Regulate Power Regulate Frequency Generator Governor

Traditional Control to Isolate Line Master Control Bus 1 Bus 2 224 230 kv 224 206 kv Tap Down Close Cap

Synchronous Recipes Execute Sent Control to Local at Precise to Controllers Isolate Instant Line Local Control Master Control Local Control Execute Recipe Simultaneously Bus 1 Bus 2 224 kv 224 kv Tap Down Close Cap

Conclusions Measurement, control, protection Dependable, deterministic communications Reliable, redundant precise time Distributed state and vector processing Demand-driven solutions are emerging Soon we will see traditional SCADA replaced by fast, distributed, automated, synchronized measurement & control.