Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Similar documents
Power Quality Analysis in Power System with Non Linear Load

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

Power Quality enhancement of a distribution line with DSTATCOM

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Investigation of D-Statcom Operation in Electric Distribution System

Volume I Issue VI 2012 September-2012 ISSN

Power System Oscillations Damping and Transient Stability Enhancement with Application of SSSC FACTS Devices

Power System Stability Improvement in Multi-machine 14 Bus System Using STATCOM

Transient Stability Improvement Of IEEE 9 Bus System With Shunt FACTS Device STATCOM

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Long lasting transients in power filter circuits

Power Quality Analysis of Non- Linear Loads for Industrial Power System

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Voltage Control and Power System Stability Enhancement using UPFC

POWER QUALITY ENHANCEMENT IN ARC FURNACE ENVIRONMENT Nupur Laxman Mali,

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

PERFORMANCE COMPARISON OF POWER SYSTEM STABILIZER WITH AND WITHOUT FACTS DEVICE

II. RESEARCH METHODOLOGY

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Improvement of Power system transient stability using static synchronous series compensator

Voltage Flicker Mitigation in Electric Arc Furnace using D-STATCOM

Transfer Capability Enhancement of Transmission Line using Static Synchronous Compensator (STATCOM)

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Brief Study on TSCS, SSSC, SVC Facts Device

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Transient Stability Enhancement with Application of FACTS Devices

Keywords: Stability, Power transfer, Flexible a.c. transmission system (FACTS), Unified power flow controller (UPFC). IJSER

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

HARMONIC COMPENSATION USING FUZZY CONTROLLED DSTATCOM

ELEMENTS OF FACTS CONTROLLERS

Journal of Electrical and Electronic Engineering

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Power Quality Compensation by using UPFC

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

Fundamental Concepts of Dynamic Reactive Compensation. Outline

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Interline Power Flow Controller: Review Paper

WIND FARM Flexible AC Transmission Systems

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

Transients under energizing multiple power filter circuits

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Power Quality Improvement in Distribution System Using D-STATCOM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

A Voltage Controlled Dstatcom for Power Quality Improvement

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Analysis of Harmonic Distortion in Non-linear Loads

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Improvement in Power Quality of Distribution System Using STATCOM

Comparison of FACTS Devices for Power System Stability Enhancement

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Chapter 10: Compensation of Power Transmission Systems

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Mitigation of Voltage Sag and Swell using D-STATCOM to improve Power Quality

Transient Stability Improvement of Multi Machine Power Systems using Matrix Converter Based UPFC with ANN

Multilevel Inverter Based Statcom For Power System Load Balancing System

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

ANALYSING THE EFFECT OF USSC CONNECTION TO DISTRIBUTION SYSTEM ON VOLTAGE FLICKER

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

CHAPTER 3 MODELLING OF PV SOLAR FARM AS STATCOM

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

I. INTRODUCTION. Keywords:- FACTS, TCSC, TCPAR,UPFC,ORPD

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Address for Correspondence

SIMULATION OF STATCOM FOR VOLTAGE QUALITY IMPROVEMENT IN POWER SYSTEM

Power System Reliability and Transfer Capability Improvement by VSC- HVDC (HVDC Light )

International Journal of Advance Engineering and Research Development

A Review on Mid-point Compensation of a Two-machine System Using STATCOM

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multimachine System

Simulation Study of a Monopole HVDC Transmission System Feeding a Very Weak AC Network with Firefly Algorithm Based Optimal PI Controller

Enhancement of Power System Voltage Stability Using SVC and TCSC

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

Power Quality and the Need for Compensation

Improvement of Power Quality Using a Hybrid Interline UPQC

Power flow improvement using Static Synchronous Series Compensator (SSSC)

Improve Power Factor and Reduce the Harmonics Distortion of the System

Transcription:

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load MADHYAMA V. WANKHEDE Department Of Electrical Engineering G. H. Raisoni College of Engineering, Nagpur 446, India madhyamawankhede@gmail.com V. K. CHANDRAKAR Department Of Electrical Engineering G. H. Raisoni College of Engineering, Nagpur 446, India Abstract: - This paper investigates performance of Static Synchronous Compensator for the transient stability improvement of the two area multi machine electrical power system with nonlinear load. The improvement of transient stability of a two-area multi-machine power system, by using STATCOM (Static Synchronous Compensator) which is a superior Flexible AC Transmission System (FACTS) tool capable of controlling the active and reactive power flowing in a transmission line by controlling appropriate parameters. Simulations are accompanied in Matlab/Simulink environment for the two-area multi-machine power system model with and without STATCOM to analyze the effects of STATCOM on transient stability performance of the system under the different conditions with and without nonlinear load. The simulation results demonstrate the effectiveness and hardiness of the proposed STATCOM on transient stability improvement of the system for the nonlinear load. Keywords FACTS, STATCOM, Nonlinear load, arc type, Matlab/Simulink, Two-area Two machine power system and PSS. Introduction A load is considered as a non-linear type of load if its impedance varies with the supplied voltage. The variable impedance means that the nature of the current which is drawn by the Non linear load will not be sinusoidal even when it is given a sinusoidal voltage. The nature of the none sinusoidal currents contains harmonic currents that interacts with the impedance of the power distribution system and create voltage distortion that can affect the distribution system equipment as well as the loads connected to it. Previously, non-linear loads were mainly found in heavy Industrial applications such as Electric Arc Furnaces, heavy rectifiers for Electrolytic refining, large Variable Frequency Drives (VFD) etc. Nowadays a very popular type of load which is used in the industry is EAF i.e., electric arc furnace type of load which is highly nonlinear in nature. Conversion of Electrical Energy into Mechanical Energy is done by Electric Arc Furnaces (EAF). Electric Arc Furnaces (EAF) are widely used in the iron and steel industry for melting the metal. Presently, 4% of the steel production is given by EAF and it is expected that this proportion will rise up to fifty percent in 25. In the industry s most of the electrical energy is utilized by EAF, and therefore efficiently use of electrical energy in EAF systems is very important problems at present. EAF causes many power quality problems as they are time varying and nonlinear type of loads. The power quality issues caused by EAF are imbalances, inter harmonics, odd and even harmonics, voltage drops and flicker in the electrical power systems. Disturbances in the waveform are the main factors in the power quality which is getting worse and these disturbances are generated by stochastic behavior of electric arc furnace [2]. The Electricity developers and the customers are trying to reduce as much as the negative effects which are caused by EAF []. The power quality issues can be solved by many techniques, in this paper we are using Static Synchronous Compensator that is STATCOM for mitigation of the voltage flickering and reduction of the total harmonic distortion. The voltage control at the required bus can be done by the first generation FACTS device Static VAR Compensator (SVC) which results in the improvement of the voltage profile of power system. The main function of SVC is used to maintain the voltage at a particular bus with the help of reactive power compensation (acquired by changing the firing angle of the thyristors) [4]. Compared with classical shunt compensation, SVCs have been used for voltage control of high performance steady state and transient condition. By optimized reactive power ISSN: 2367-8976 27 Volume, 26

control SVCs are also applied for damping power swings, improve transient stability and reduce system losses [3]. The next generation of flexible ac transmission system (FACTS) devices is Static Synchronous Compensator (STATCOM). The STATCOM is used in the electrical power system for different purposes such as line loss minimization, reactive power compensation, power oscillation damping etc. The Static Synchronous Compensator is a combination of voltage source converter in parallel with the capacitor which acts as a DC energy source link tied to the transmission line. Almost Sinusoidal current of varying magnitude at the PCC (point of connection) is injected by the STATCOM. This injected current is almost in 9 phase with the line voltage, which helps in emulating an inductive or a capacitive reactance at the point of common coupling with the transmission line. Although the functions of STATCOM and SVC are same, but STATCOM has more advantages as compared to SVC which are, Responds faster. Space required is less as bulky passive components (such as reactors) are eliminated. It is inherently relocatable and modular. It can be interfaced with real power sources such as fuel cell, battery or Superconducting magnetic energy storage (SMES). As the reactive current can be maintained constant STATCOM has high quality performance during the low voltage condition. In SVC, the capacitive reactive current drops in linear manner with the voltage at the limit. Under transient conditions, it is even possible to increase the reactive current in a STATCOM if the devices are rated for transient overload whereas in SVC, the maximum reactive current is determined by rating of the passive components reactors and capacitors.[4] As the STATCOM is more advantageous as compared to SVC, therefore it is preferred over SVC. If STATCOM is designed well, then it serves as an advantageous Investment for the power companies. Therefore it can bring Productive Gains for the company as well as customers. 2 Static Synchronous Compensator (STATCOM) Fig. shows the configuration of STATCOM, which consists of a solid state synchronous voltage source converter (VSC), a coupling transformer and a dc capacitor. The solid state synchronous voltage source converter (VSC) generates a balanced bunch of 3 sinusoidal voltages at the fundamental frequency with rapidly controllable amplitude and phase angle. Idc Iq Vdc Vt Cdc DC ENERGY SOURCE TRANSMISSION LINE COUPLING TRANSFORMER VSC Fig. Static Synchronous Compensator (STATCOM) 3. Multi Machine Power System Model The system model considered for analysis is a two area multi machine system which is shown in the fig 3. And the system data is shown in the Table. GENERATOR TRANSFORMER BUS BUS 2 Fault STATCOM Fig. 3 Single line diagram BUS 3 TRANSFORMER2 L O A D NON LINEAR LOAD GENERATOR2 ISSN: 2367-8976 28 Volume, 26

DEVICE Generator Generator2 Transformer Transformer 2 Transformer 3 Transmission Line RATING MVA 5MVA MVA, 3.8/5KV 5MVA, 3.8/5KV MVA, 5KV/ KV 35km distribution system equipment as well as the loads which are connected to it. Previously, Non-Linear loads were primarily found in heavy Industrial applications such as electric arc furnaces, large variable frequency drives (VFD), heavy rectifiers for electrolytic refining, etc []. In this paper a very popular load which is EAF that is Electric Arc Furnace load which is highly Non-linear in nature is presented along with its equivalent circuit and Simulink model. 4. Equivalent Circuit of the Electricity System Supplying to Electric Arc Furnace Transmission Line 2 Three Phase Load Non Linear Load 35km 5MW MW (.7 power factor) Pr imary c ircu it Step Down Transformer Regulator Table. Data sheet for the system model The system model consists of 3 phase hydraulic generation plant at the two ends along with the 3 phase transformers which are connected by transmission lines of 5km. The hydraulic generation plant at the one end is of MVA capacity whereas the other hydraulic generation plant is of 5 MVA capacity. The system model consists of two step up transformers which step ups the voltage from 3.8KV to 5 KV. There are three buses which are connected with the help of transmission lines of 35 km long. At the third bus, three phase load is connected which is of 5 MW capacity. The non-linear type of load is connected at the bus 3 with the help of a three phase transformer. The nonlinear type of load is of MW capacity. The performance of the system under the different load conditions along with the different types of faults such as ground fault, three phase fault etc., is observed. Secandary c ircu it EAF Transformer Flexible Cable Electrodes Fig. 4 Equivalent Circuit of EAF The the equivalent circuit of EAF is shown in the figure above. In the primary circuit a step down transformer is used which will reduce the value of the voltage and then that voltage level is regulated for that regulator is used. The secandary circuit EAF transformer is used which will lower the value of the voltage as per the voltage required by the EAF load. For production of huge amount of heat the elctrodes are connected. The MATLAB/simulink model for the EAF is shown below. The MATLAB simulink model of arc type of load is shown in the fig below 4. Non Linear Load:- A load is considered as Non-Linear if the load impedance changes with the applied voltage. The changing impedance can be defined as the current given by the Non-Linear load will not be sinusoidal even when it is connected to a sinusoidal voltage. These Non-Sinusoidal currents consists of harmonic currents that interacts with the impedance of the electrical power distribution system and create voltage distortion that can affect both the ISSN: 2367-8976 29 Volume, 26

Fig 5. MATLAB/ Simulink Model The arc type of characteristics can be obtained with the help of MATLAB simulink model which is shown in the figure. The above MATLAB simulink model gives the nature of characteristics shown in the figure which gives the characteritics of the arc type of load. The x axis represents voltage axis, whereas y axis represents current axis. As shown in the figure non linearity of the load varies in both the polarities under the different condition are observed which are explained below. 5. Case :- Under the normal condition, without STATCOM & without Nonlinear load As shown in the figure Vb, Vb2 & Vb3 are the bus voltages in PU at the buses, 2 & 3 respectively. The second curve is of line power in MW. ȏ is the rotor angle in degrees. ɷ & ɷ2 are the rotor speeds in PU. Vt and Vt2 are the terminal voltages in PU. As shown in the figure, as there is no non linear load present in the system the bus voltages and the line power are at the required value which are giving the stable results. Similarly the rotor angle and the terminal voltages are also giving the stable results as there is normal condition..5 V pos, seq. B B2 B3 (pu).5 Fig6. V-I characteristics 8 6 4 2 Line power (MW) x 4.5 -.5-53.2 53. 53 d_theta_2 (deg) 5-5 - Fig 7. Arc currents and arc voltages The nature of the arc current and arc voltage is shown in the fig. From the fig we can see that for the very minimum span of time the arc current and arc voltage varies rapidly. This nature of the arc type of characteristics can cause many problems such as voltage drop different power quality issues, etc. Therefore these type of non linearities should be reduced in order to minimize the bad effects which may be occurred in the power system due to these non linearity. We can reduce these type of non linearity by using Static Synchronous Compensator. 5. Simulation Results The simulation is done in the MATLAB Simulink software and observations are done under the different conditions. The behavior of the system 52.9.2.9998 w w2 (pu).9996.5.5 Vt Vt2 (pu) Fig 8. Simulation Results when under the normal condition, without STATCOM & without nonlinear load 5.2 Case 2:- Without STATCOM and With Non linear load The second case we have taken is when there is no STATCOM but nonlinear load is connected into the system. As soon as nonlinear load is connected the disturbances can be seen in the simulation results. The arc type of load is highly nonlinear and because of that the bus voltages are affected, and the system parameters are fully disturbed which are shown in the figure. Now next task is to reduce these disturbances caused by the nonlinear load which is done in the next case. ISSN: 2367-8976 3 Volume, 26

M. V. Wankhede, V. K. Chandrakar.5.5 V pos, seq. B B2 B3 (pu) Fig. Simulation Results when without STATCOM and With Nonlinear load 5 5 Line power (MW) 6 4 d_theta_2 (deg) 2..5 w w2 (pu).95.5.5 Vt Vt2 (pu) Fig 9. Simulation Results when without STATCOM and With Nonlinear load 5.3 Case 3:- With STATCOM and Nonlinear load In the third case there is a nonlinear load and the STATCOM is now connected into the system. The results are shown in the simulation results where the disturbances which are caused by the nonlinear are reduced to some extent the bus voltages are coming to the PU. Similarly, the other system parameters are also getting balanced after few seconds. Therefore the effect of STATCOM can be seen in the simulation results which are balanced results..5.5 V pos, seq. B B2 B3 (pu) 5 5 Line power (MW) 6 5 4 d_theta_2 (deg) 3 w w2 (pu).2. Vt Vt2 (pu) 2 6. Conclusion This Paper deals with the applications of Static Synchronous Compensator for the performance improvement of the Electrical Power System for the nonlinear load. The detailed model of STATCOM was implemented and tested in MATLAB/Simulink environment. The verification of the STATCOM under the steady state condition is tested in the MATLAB/Simulink environment. The system behavior is observed under the various conditions with STATCOM and without STATCOM along with the nonlinear load. The behavior of the system parameters are then observed. The system parameters are the bus voltages in per unit, line power in MW, rotor angle in degree, rotor speeds in per unit and terminal voltages in per unit. The system model is applicable for voltage stability analysis. The effects of STATCOM installed in power transmission path are analyzed in this paper and the conclusion as follows: Under the normal condition the system behavior is balanced but when the nonlinear load is connected in the system the disturbances are observed. As the parameters are fully disturbed, therefore the disturbances gets reduced when the STATCOM is connected into the system. Therefore the power quality issues which are caused by the nonlinear load is resolved with the help of STATCOM. References: [] Mustafa Şeker, Arif Memmedov, Investigation of Voltage Quality in Electric Arc Furnace with Matlab/Simulink, International Journal of Engineering and Technical Research (IJETR) ISSN: 232-869, Volume-2, Issue-, November 24, pp 274-284 [2] Rafael Collantes-Bellido, Tomas Gomez, Identification and modelling of a Three Phase Arc Furnace for Voltage Disturbance Simulation., IEEE Transactions on Power Delivery, Vol. 2, No. 4, October 997, pp 82-87 [3] Prity Bisen and Amit Shrivastava, Comparison between SVC and STATCOM FACTS Devices for Power System Stability Enhancement, International Journal on Emerging Technologies, pp -9 ISSN: 2367-8976 3 Volume, 26

[4] K. R. Padiyar, FACTS CONTROLLERS IN POWER TRANSMISSION AND DISTRIBUTION, NEW AGE INTERNATIONAL PUBLISHERS, pp 73-77 [5] Prabha Kundur, Power System Stability And Control, TATA McGRAW-HILL EDITION, pp 335 [6] V. K. Chandrakar, A.G. Kothari, Fuzzy-based Static Synchronous Compensator (STATCOM) for improving transient stability performance, Int. J. Energy Technology and Policy, Vol. 5, No. 6, 27, pp 692-77 [7] B. Singh, R. Saha, A. Chandra, K. Al-Haddad, Static synchronous compensators (STATCOM): a review, The Institution of Engineering and Technology 29, pp 297-324 [8] Gary W. Chang, Fellow, Min-Fu Shih, Yi- YingChen, and Yi-Jie Liang, A Hybrid Wavelet Transform and Neural-Network-Based Approach for Modelling Dynamic Voltage- Current Characteristics of Electric Arc Furnace, IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 29, NO. 2, APRIL 24, pp 85-824 ISSN: 2367-8976 32 Volume, 26