HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

Similar documents
Advance on High Power Couplers for SC Accelerators

OVERVIEW OF INPUT POWER COUPLER DEVELOPMENTS, PULSED AND CW*

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

CAVITY DIAGNOSTIC SYSTEM FOR THE VERTICAL TEST OF THE BASELINE SC CAVITY IN KEK-STF

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

KEK ERL CRYOMODULE DEVELOPMENT

Couplers for Project X. S. Kazakov, T. Khabiboulline

High Power Couplers for TTF - FEL

EXPERIMENTAL RESULT OF LORENTZ DETUNING IN STF PHASE-1 AT KEK-STF

HIGH POWER COUPLER FOR THE TESLA TEST FACILITY

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

DEVELOPMENTS OF HORIZONTAL HIGH PRESSURE RINSING FOR SUPERKEKB SRF CAVITIES

RF power tests of LEP2 main couplers on a single cell superconducting cavity

Coupler Electromagnetic Design

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

Current Status of cerl Injector Cryomodule

Mircea Stirbet. RF Conditioning: Systems and Procedures. Jefferson Laboratory

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

Third Harmonic Superconducting passive cavities in ELETTRA and SLS

THE CRYOGENIC SYSTEM OF TESLA

Superconducting RF cavities activities for the MAX project

THE PROTOTYPE FUNDAMENTAL POWER COUPLER FOR THE SPALLATION NEUTRON SOURCE SUPERCONDUCTING CAVITIES: DESIGN AND INITIAL TEST RESULTS*

CRAB CAVITY DEVELOPMENT

Processing and Testing of PKU 3-1/2 Cell Cavity at JLab

RF thermal and new cold part design studies on TTF-III input coupler for Project-X

Liquid Helium Heat Load Within the Cornell Mark II Cryostat

THE HIGH LUMINOSITY PERFORMANCE OF CESR WITH THE NEW GENERATION SUPERCONDUCTING CAVITY

HIGH POWER PULSED TESTS OF A BETA=0.5 5-CELL 704 MHZ SUPERCONDUCTING CAVITY

QUARTER WAVE COAXIAL LINE CAVITY FOR NEW DELHI LINAC BOOSTER*

CAGE CAVITY: A LOW COST, HIGH PERFORMANCE SRF ACCELERATING STRUCTURE*

LEP Couplers..a Troubled Story of a Success. HPC2002, Jefferson Lab, October 30 th, 2002 R. Losito, CERN 1

DEVELOPMENTS AND PROGRESS WITH ESS ELLIPTICAL CRYOMODULES AT CEA-SACLAY AND IPN-ORSAY -

A few results [2,3] obtained with the individual cavities inside their horizontal cryostats are summarized in Table I and a typical Q o

Development of a Vibration Measurement Method for Cryocoolers

SRF Advances for ATLAS and Other β<1 Applications

Design and technology of high-power couplers, with a special view on superconducting RF

3.9 GHz work at Fermilab

Status and Plans for the 805 MHz Box Cavity MuCool RF Workshop III 07/07/09 Al Moretti

KEYWORDS: ATLAS heavy ion linac, cryomodule, superconducting rf cavity.

MULTIPACTING IN THE CRAB CAVITY

LOW BETA CAVITY DEVELOPMENT FOR AN ATLAS INTENSITY UPGRADE

CEBAF waveguide absorbers. R. Rimmer for JLab SRF Institute

Design of the 352MHz, beta 0.50, Double- Spoke Cavity for ESS

Report of working group 5

Superconducting RF System. Heung-Sik Kang

5.5 SNS Superconducting Linac

Current Industrial SRF Capabilities and Future Plans

REVIEW ON SUPERCONDUCTING RF GUNS

Design, Development and Testing of RF Window for C band 250 kw CW Power Klystron

Tuning systems for superconducting cavities at Saclay

Experience with 3.9 GHz cavity HOM couplers

S. Ghosh On behalf of Linac, IFR, Cryogenics, RF and beam transport group members. Inter University Accelerator Centre New Delhi India

Superconducting Cavity Fabrication for ILC in Japan

To produce more powerful and high-efficiency particle accelerator, efforts have

Packaging of Cryogenic Components

The transition for the Elettra Input Power Coupler to the standard WR1800

C100 Cryomodule. Seven cell Cavity, 0.7 m long (high Q L ) 8 Cavities per Cryomodule Fits the existing Cryomodule footprint

2 Theory of electromagnetic waves in waveguides and of waveguide components

EXPERIENCE ON THE SUPERCONDUCTING RF SYSTEM IN TRISTAN

Mechanical study of the «Saclay piezo tuner» PTS (Piezo Tuning System) P. Bosland, Bo Wu DAPNIA - CEA Saclay. Abstract

R.Bachimanchi, IPAC, May 2015, Richmond, VA

CHALLENGES IN ILC SCRF TECHNOLOGY *

TESTS AND DESIGNS OF HIGH-POWER WAVEGUIDE VACUUM WINDOWS AT CORNELL

MuCool Test Area Experimental Program Summary

Cavity development for TESLA

International Technology Recommendation Panel. X-Band Linear Collider Path to the Future. RF System Overview. Chris Adolphsen

ALICE SRF SYSTEM COMMISSIONING EXPERIENCE A. Wheelhouse ASTeC, STFC Daresbury Laboratory

Superconducting 1.3 GHz Cavities for European XFEL

SUPERCONDUCTING PROTOTYPE CAVITIES FOR THE SPALLATION NEUTRON SOURCE (SNS) PROJECT *

L W C S1 S & & ILC L 1 C

PROGRESS IN THE ELLIPTICAL CAVITIES AND CRYOMODULE DEMONSTRATORS FOR THE ESS LINAC

RENASCENCE * PERFORMANCE AND PROBLEMS ON FIRST TEST Feedthrough leaks sub 70 K. End group quenching

OVERVIEW OF REGIONAL INFRASTRUCTURES FOR SCRF DEVELOPMENT

INSTRUMENTATION AND CONTROL SYSTEM FOR THE INTERNATIONAL ERL CRYOMODULE

Completion of the first SSR1 cavity for PXIE

ACHIEVEMENT OF ULTRA-HIGH QUALITY FACTOR IN PROTOTYPE CRYOMODULE FOR LCLS-II

Status Alcator C-Mod Engineering Systems. DoE Quarterly Review October 27, 2005

Preparation of RF Power Couplers For the Tesla Test Facility

Behavior of the TTF2 RF Gun with long pulses and high repetition rates

THE MULTIPACTING STUDY OF NIOBIUM SPUTTERED HIGH-BETA QUARTER-WAVE RESONATORS FOR HIE-ISOLDE

2008 JINST 3 S The RF systems and beam feedback. Chapter Introduction

SRF EXPERIENCE WITH THE CORNELL HIGH-CURRENT ERL INJECTOR PROTOTYPE

Overview of ERL Projects: SRF Issues and Challenges. Matthias Liepe Cornell University

XFEL Cryo System. Project X Collaboration Meeting, FNAL September 8-9, 2010 Bernd Petersen DESY MKS (XFEL WP10 & WP13) 1 st stage. Possible extension

Yongming Li Institute of modern physics 31/07/2017

ASSEMBLY PREPARATIONS FOR THE INTERNATIONAL ERL CRYOMODULE AT DARESBURY LABORATORY

Commissioning of the ALICE SRF Systems at Daresbury Laboratory Alan Wheelhouse, ASTeC, STFC Daresbury Laboratory ESLS RF 1 st 2 nd October 2008

Development Status of KSTAR LHCD System

Third Harmonic Cavity Status

Nb 3 Sn Present Status and Potential as an Alternative SRF Material. S. Posen and M. Liepe, Cornell University

Advances in CW Ion Linacs

DESIGN OPTIONS FOR CEBAF ENERGY UPGRADE

On behalf of: Sang-hoon Kim Zack Conway Mark Kedzie Tom Reid Ben Guilfoyle

Progresses on China ADS Superconducting Cavities

CONICAL HALF-WAVE RESONATOR INVESTIGATIONS

Construction Status of SuperKEKB Vacuum System

Project X Cavity RF and mechanical design. T. Khabiboulline, FNAL/TD/SRF

R.L. Geng, C. Crawford, H. Padamsee, A. Seaman LEPP, Cornell University, Ithaca, NY14853, USA

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

Maurizio Vretenar Linac4 Project Leader EuCARD-2 Coordinator

Transcription:

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK E. Kako #, H. Hayano, S. Noguchi, T. Shishido, K. Watanabe and Y. Yamamoto KEK, Tsukuba, Ibaraki, 305-0801, Japan Abstract An input coupler, which consists of a cold coupler and a warm coupler, has two Tristan-type coaxial disk rf windows. There is no tuning mechanism for varying coupling for simplicity and cost reduction. Fabrication of four input couplers was completed, and the rf measurements with low rf power were carried out. The input couplers were assembled with coupling waveguides and doorknob-type transitions, and they were installed in a high power rf system. High power tests of four input couplers were carried out in the test stand with a 5 MW pulsed klystron. Rf processing up to 1.0 MW in a 1.5 msec and 5 Hz operation (1.9 MW in a short pulse) was successfully performed without any troubles. One cavity for the STF Phase-0.5 was assembled with an input coupler and a tuning system, and the cavity was installed in one of the 6m-cryomodules. Rf processing of the input coupler in the cryomodule was carried out at room temperature up to 250 kw in a 1.5 msec step pulse and 5 Hz operation. First cool-down and high power test of the cryomodule had been started in October, 2007. INTRODUCTION Construction of STF (Superconducting RF Test Facility) is being carried out at KEK, [1, 2]. The main purpose of STF is to develop the cryomodule including high performance cavities and to establish the industrial design of a Main-Linac unit for ILC (International Linear Collider). One of the important tasks is to carry out high power tests of the STF cryomodule, which includes four TESLA-type STF-Baseline 9-cell cavities and four Low- Loss-type High-Gradient 9-cell cavities. The specific feature of the STF-Baseline cavity is an improved stiffness of the total cavity supporting system to suppress deformation of cells due to Lorentz force in a pulsed operation. The cavity system mainly consists of a 9-cell niobium cavity, an input coupler, HOM couplers, a mechanical tuner, a He vessel and a magnetic shield, [3]. A high power input coupler, which is used for transferring rf power to a superconducting cavity, is designed for the STF baseline cavity system. The input coupler, which consists of a cold coupler and a warm coupler, has two Tristan-type coaxial disk windows, [4]. A similar design of the rf windows had been used in the 972MHz cryomodule for ADS, and input rf power of 2.2 MW in a pulsed operation had been successfully transferred, [5]. In this paper, design and fabrication of the input couplers with doorknobs and coupling waveguides, low power tests of the rf components, high power tests in the test stand and rf processing in the cryomodule are described. # eiji.kako@kek.jp COUPLER DESIGN Conceptual design of an input coupler for the STF- Baseline cavity is shown in Fig. 1, and the fundamental specification is summarised in Table 1. The specific feature is no tuning mechanism for varying coupling for simplicity and cost reduction, so that bellows with flexibility were eliminated at the cold coupler. The diameter of the input port to connect with a cavity was enlarged to 60 mm in order to make a usable rf window size larger to raise up a power capability. The cold coupler is cooled by a thermal anchor at 5 K by helium and at 80 K by nitrogen, and the calculated heat loads at 2 K, 5 K and 80 K are listed in Table 2. Although thin copper plating on an inner surface of the outer conductor is only 5 μm, the static loss at 5 K is larger than the dynamic loss of 0.2 W at input power of 350 kw. External Q of the input coupler was calculated by HFSS in a single-cell model cavity with two antennas, and the result is shown in Fig. 2. The distance between the antenna tip and the beam axis was determined to 32 mm, so as to obtain an external Q value of 2.0 x 10 6. The over-coupling ratio of 1.55 was determined for making a bandwidth widen to Figure 1: Input coupler for the STF-Baseline 9-cell Cavity. Table 1: Specification of the input coupler. Frequency 1.3 GHz Pulsed operation 1.5 msec, 5 Hz Beam current 10 ma Accelerating gradient 31.5 MV/m Input rf power 350 kw External Q value 2.0 x 10 6 Table 2: Calculation of the heat load. 80 K 5 K 2 K ==================================== Static Loss [W] 5.0 1.1 0.05 Dynamic Loss [W] 3.0 0.2 0.03 270 TUP: Poster Session I

TUP60 assure more stable operation. The half bandwidth was extended from 210 Hz in an optimum coupling to 325 Hz, and the increase of the required input rf power is about 5% in this case. The optimum structure of a coaxial rf window with a planar ceramic disk, a doorknob transition to a waveguide system and a pair of coupling waveguide as a vacuum chamber was determined with the HFSS code, as shown in Fig. 3 and Fig. 4. The maximum electric field of 770 kv/mm at the rf window is estimated at input power of 350 kw. 10 7 Qext Cal. Q-inp. External Q of Input Coupler 10 6 Target ; Q = 2.0x10 6 at 32 mm φ = 84 mm L = 58 mm 10 5 20 25 30 35 40 45 Antenna Tip (from Beam axis) [mm] Figure 2: Calculated external Q value as a function of the antenna tip position from the beam axis. (φ is a diameter of the beam tube, 84 mm, and L is a length between the cell-end and the antenna axis, 58 mm) FABRICATION OF INPUT COUPLERS RF windows Ceramics disks are made of Al 2 O 3 with the purity of 95%, (HA95 from NTK). The disk sizes of a cold and a warm rf window are 6.2 mm and 6.6 mm in the thickness, 92 mm and 116 mm in the outer diameter, respectively. Thermal shock tests of the ceramics disks were repeatedly carried out by liquid nitrogen. After this, coating with TiN on the surface of the vacuum side was performed, and the thickness of the deposited layer is about 10 nm. First brazing for fabricating rf windows was carried out at about 1000 o C in a hydrogen furnace, and the completed coaxial rf windows are shown in Fig. 5, (at Toshiba ETD). Input Couplers The second step of the brazing procedure is the joining of rf windows and coaxial parts which consist of an inner conductor (antenna) and an outer conductor. The coaxial parts are made of stainless steel, and copper plating of 30 μm on the rf surface was carried out, except an outer conductor of a cold coupler (5 μm) to reduce a heat transfer. The completed couplers after the second brazing at about 800 o C are shown in Fig. 6. In the final step, small flanges made of stainless steel were welded with the ports by TIG. Figure 5: Two warm rf windows (Top) and two cold rf windows (Bottom) after the initial brazing. Figure 3: Rf electric field at a cold-warm input coupler and a doorknob, and the frequency characteristics ; (S11 = -26.2 db at 1.3 GHz, ε* of ceramic = 9.2). Figure 4: Rf electric field at a coupling waveguide and two cold couplers, and the frequency characteristics ; (S11 = -55. db at 1.3 GHz, ε* of ceramic = 9.2). Figure 6: Four cold couplers (Top) and two warm couplers (Bottom) after the final brazing. TUP: Poster Session I 271

Figure 8: Assembly of the input couplers in a clean room. Figure 7: Coupling waveguides for a vacuum chamber (Top) and two doorknob-type transitions (Bottom). Doorknob Transitions A doorknob, as shown in Fig. 7 (Bottom), is used for transition between a coaxial line (104D) and a waveguide system (WR650). The inner component like a doorknobshape was formed by spinning from a thin copper plate of 0.6 mm and was fixed with the outer frame made of aluminium. The location of an end-plate for a short circuit of a waveguide was adjusted before welding, so as to make a matching condition best at 1.3 GHz. Coupling Waveguides A pair of coupling waveguide, as shown in Fig. 7 (Top), is used for a vacuum chamber to install a pair of input couplers. The coupling waveguide was fabricated with stainless steel plates of 5 mm, and the inner surface was coated with copper plating of 30 μm to suppress heating due to rf losses. Two facing flanges were joined with an indium seal. HIGH POWER TEST STAND Assembling Procedure Components of the input couplers and the coupling waveguides were carefully rinsed with ultra-pure water at nominal pressure, and were dried for one day in a clean room (class 10), as shown in Fig. 8. After assembling of the input coupler system in a clean room, pumping was carried out by two vacuum systems composed of a turbo molecular pump of 320 l/s and a scroll pump of 250 l/m; one is for the cold coupler side including the coupling waveguide, and another is for two warm couplers. The input coupler system was bake out at 100 o C for 48 hours, prior to rf processing. The vacuum pressure at room temperature reached to less than 10-5 Pa. RF Measurement Rf characteristics of the whole input coupler system for high power tests were measured, as shown in Fig. 9. Reflection is less than about -20 db within the wide range of 70 MHz. Reflected power of about 1 % was confirmed in an operation at 1.3 GHz. Figure 9: RF measurement of the whole system of the test stand, (S11= -18.8 db at 1.3 GHz). Figure 10: Se-up of the high power test stand. High Power Test System An experimental set-up for high power tests is shown in Fig. 10. A pulsed klystron with the maximum output rf power of 5 MW in an operation with 1.5 msec and 5 Hz is used for the high power tests. The waveguide system is connected with a 5 MW circulator and terminated by a water-cooled dummy load. Forward and reflected rf powers are monitored by two directional couplers connected at both the up-stream and the down-stream of the test stand. An ionization vacuum gauge is installed in each pumping system of the cold coupler side and the warm coupler side. An arc sensor is attached at the vacuum side of each rf warm window. Three electron pick-up probes in each coupler are attached at the location close to both sides of the cold rf window and only vacuum side of the warm rf window. Temperature rises at the rf windows are monitored by thermal sensors. Two video cameras at the bottom of the coupling waveguides can observe visible lights like a glow discharge by multipacting. These monitoring instruments are very important to prevent a fatal sparking discharge around the rf windows. 272 TUP: Poster Session I

TUP60 RF PROCESSING AT TEST STAND Processing of #1 and #2 Input Couplers Rf processing was initially started in a 100 μsec and 1 Hz operation. The first deterioration of the vacuum pressure was observed at 40 kw in the cold side and at 70 kw in the warm side. Interlock level of the vacuum pressure was set to 7 x 10-4 Pa in the initial processing, and then reduced to 2 x 10-4 Pa. The rf processing procedure was carried out very carefully, so that the processing time was 13 hours up to 300 kw and 22 hours up to 1 MW, as shown in Fig. 11. After this, the repetition rate was increased to 5 Hz, and no severe vacuum deterioration was observed with the increase of the rf power. The power supply system of the klystron was improved in order to extend an available pulse width from 100 μsec to 1.5 msec. The second run of rf processing was carried out up to 1.4 MW in a 100 μsec and 500 μsec operation with 5 Hz, and finally the rf power of 1.0 MW in a 1.5 msec operation was successfully transferred to the input couplers. Figure 13: Total processing time up to 1.0 MW in a 1.5 msec and 5 Hz operation. ASSEMBLY OF CRYOMODULE Installation of a Cold Coupler in a Cavity One cavity for the STF Phase-0.5 was assembled with a cold input coupler in a new clean room (class-10), as shown Fig. 14. The outside of the coupler was carefully cleaned by wiping and blowing. The inside of the couplers was filled by filtered high purity nitrogen gasses, just before dismounting from the test stand. A helicoflex seal coated with indium plating of 30 μm and stainless steel bolts coated with silver plating were used for joining with the flange of the cavity port. Figure 11: Time evolution of the input rf power and the vacuum pressure during the initial rf processing in a 100 μsec and 1 Hz operation for the #1 and #2 couplers. Processing of #3 and #4 Input Couplers Initial rf processing was started in a shorter pulse width of a 10 μsec and 5 Hz operation, and the processing time up to 1.9 MW was about 20 hours, as shown in Fig.12. Then, the pulse width was extended to 30 μsec, 100 μsec and 500 μsec, and finally processing up 1.0 MW in a 1.5 msec and 5 Hz operation was carried out without any problem. The total processing time was about 50 hours and is summarised in Fig.13. Figure 14: Installation of a cold coupler into a cavity Assembly of the Cryomodule The cavity equipped with a cold input coupler and a tuner system was installed in a gas return pipe of one 6mcryomodule, as shown in Fig. 15. A heater was attached surround a cold window with a thermal sensor for in-situ baking inside the cryomodule. Baking of a cold rf window prior to rf processing at room temperature is very effective to reduce the processing time. Since bellows at the cold input coupler were eliminated, the supporting system of the coupler is unnecessary and the installation work had been very simple and easy. Figure 12: Time evolution of the input rf power and the vacuum pressure during the initial rf processing in a 10 μsec and 5 Hz operation for the #3 and #4 couplers. Figure 15: Baking heater and 80 K shielding attached on a cold rf window (Left), and an assembled cavity mounted on 2 K gas return pipe (Right). TUP: Poster Session I 273

RF PROCESSING IN THE CRYOMODULE Installation of a Warm Coupler After installation of the cryomodule in the STF tunnel, connection of a warm coupler with a cold coupler was carried out in a working area covered with a special clean booth to keep a clean environment, as shown in Fig.16. The cold rf window in a insulation vacuum of the cryomodule and the warm coupler pumping system were baked out at 100 o C for 65 hours, and the vacuum pressure in the cold (cavity) side and in the warm side reached to 3 x 10-7 Pa and 7 x 10-7 Pa at room temperature, respectively. Figure 16: Installation of a warm coupler in a cryomodule. RF Processing in the Cryomodule After baking, a doorknob transition was attached in the warm coupler and was connected with a 500 kw circulator by a flexible waveguide, as shown in Fig. 17. Rf processing in the cryomodule was started in a 30 μsec and 5 Hz operation, and the input rf power reached to a target power of 230 kw within only 2 hours, as shown in Fig.18. No vacuum deterioration was observed in the cold (cavity) vacuum. Electron activities were detected only at the warm side of the cold window, and the multipacting level was observed around 100 kw. There was no work of the interlock system during keeping at 250 kw for 7 hours, except trivial troubles of the rf power source. Temperature at the cold window increased to 37 o C in the end of the rf processing. Rf processing at room temperature was carried out for total 23 hours in three days. The high gradient test of the cavity at 2 K is scheduled in November 2007, in the next step. Figure 18: RF processing logs of one input coupler in the cryomodule at room temperature. SUMMARY Four input couplers for the STF baseline cavity system were designed and fabricated. They had been successfully tested at the high power test stand up to 1.0 MW in the pulsed operation with 1.5 msec and 5 Hz. One coupler had been installed in the STF cryomodule, and had been processed up to 250 kw at room temperature. High power tests in the cryomodule to achieve a higher accelerating gradient at 2 K will be carried out soon. ACKNOWLEDGMENTS The authors would like to thank A. Yano and K. Tetsuka (Toshiba Electron Tubes & Devices Co., Ltd.) for the fabrication of the input couplers. Special thanks are given to N. Okamoto (Broad Wireless Co., Ltd.) for manufacturing the doorknob transitions. One of the authors, Eiji Kako, deeply appreciates Mr. Minoru Kawaguchi for his continued effort and hard work in the construction of the high power rf distribution system. REFERENCES [1] S. Noguchi, et al., STF Baseline Cavities and RF Components, SRF2005, Cornell Univ., Ithaca, USA, (2005), http://www.lns.cornell.edu/public/srf2005/. Also, presentation for the ILC seminar at KEK, (May 11 th, 2007), http://lcdev.kek.jp/localmeetings/. [2] H. Hayano, Superconducting RF Test Facility (STF) in KEK, SRF2005, Cornell Univ., Ithaca, NY, USA (2005) p409-411. [3] E. Kako, et al., Construction of the STF Baseline Cavity System for STF at KEK, PAC07, Albuquerque, NM, USA, (2007) p2107-2109. [4] S. Noguchi, E. Kako and K. Kubo., Couplers Experience at KEK, 4 th SRF Workshop, KEK, Tsukuba, Japan, (1989) p397-412. [5] E. Kako, S. Noguchi and T. Shishido, Input Couplers for 972 MHz Superconducting Cavities in the High Intensity Proton Linac, 11 th SRF Workshop (SRF2003), Luebeck/Travemuende, Germany, (2003) ThP27. Figure 17: Set-up for the rf processing in the cryomodule. 274 TUP: Poster Session I