Underground System Design TADP 547

Similar documents
Fault location on power cables. Fault location on power cables

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

POWER AND COMMUNICATION CABLES Theory and Applications

Field Measurement of Transmission Cable Dissipation Factor

MV Power Cable Testing Training

Power Cables and their Application

Underground System Design TADP 547

Medium Voltage Power Cables

MEDIUM VOLTAGE

Tests on Extruded Cables

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

CIR (Crush & Impact Resistant) VFD Power Cable

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Criteria. Table of Contents

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

Assuring the Reliability of Critical Power Cable Systems

A. Product Description: Stranded conductor insulated wire.

INTERNATIONAL STANDARD

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Basic Principles and Operation of Transformer

Addison Medium Voltage Cables

Industrial and Commercial Power Systems Topic 7 EARTHING

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

14 AWG 2 AWG: 600 Volt

EI HIGH VOLTAGE INSULATION TESTING POLICY

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Substation HV Cables. Document Number: 1-11-FR-07

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

TIGER BRAND MINING CABLES

This is a preview - click here to buy the full publication. IEC 2006 Copyright - all rights reserved

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Cable Data Collector (CDC): Application Guide

DLO Flexible Power Cable

Specialists in HV and MV test and diagnostics. Testing in Substations

Kerman & Kavian Cable Industries ( KCI )

TECHNICAL SPECIFICATION

A6.6 9 th International Conference on Insulated Power Cables A6.6

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Earthing of Electrical Devices and Safety

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

ECP HV INSULATION TESTING

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Testing 320 kv HVDC XLPE Cable System

LIST OF IS STANDARDS FOR ELECTRICAL PROJECTS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

CONTENTS. 1. Introduction Generating Stations 9 40

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

SECTION MEDIUM-VOLTAGE CABLES

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

CABLE JOINTING KITS &

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

7. INSPECTION AND TEST PROCEDURES

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

ECP HV INSULATION TESTING

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Conductors and Raceway Design

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

ASTA TEST REPORT NO: HEATSHRINK TERMINATIONS 3 CORE 12kV PILC AND XLPE

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

EVALUATION AND COMPARISON OF ON-LINE PD DETECTION METHODS FOR HIGH-VOLTAGE POWER CABLE

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Evaluation of Distribution Line Spacers through the Leakage Current Monitoring

Surge Protection and Grounding Issues

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

VSD cables in. Working with. industrial & automation applications

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

SECTION TRANSFORMERS

AMERICAN PUBLIC TRANSIT ASSOCIATION 2003 RAIL TRANSIT CONFERENCE. Cable Rating Considerations for Direct Current Traction Power Systems

CONTINUING EDUC ATION

Number: Prepared by: TABLE OF CONTENTS

Transcription:

Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas

Industry Organizations Several professional organizations develop standards and guides for the power cable industry worldwide. A main goal of these organizations is to standardize on material, test procedures, and adopt best practices. The main organizations in the U.S. are the Institute of Electrical and Electronics Engineers (IEEE), Insulated Cable Engineers Association (ICEA), and Association of Edison Illuminating Companies (AEIC). Standards used outside the U.S. are developed by the International Electrotechnical Commission (IEC).

IEEE History IEEE is an association dedicated to advancing innovation and technological excellence. IEEE s roots go back to 1884 when electricity was just beginning and has now become a major force in society. Originally formed as the American Institute of Electrical Engineers (AIEE) to support electrical engineering professionals and to help them apply innovation. The Institute of Radio Engineers (IRE) was formed in 1912 (and modeled after AIEE) to support the radio and electronics field. AIEE and IRE merged in 1963 to form the IEEE. At that time they had 150,000 members, with 140,000 in the U.S. Today IEEE has about 400,000 members in 160 countries.

IEEE Standards and Guides IEEE has numerous Standards, Specifications, and Guides related to the power cable industry. A few key standards and guides follow: IEEE 48 - IEEE Standard Test Procedures and Requirements for Alternating-Current Cable Terminations 2.5 kv Through 765 kv. Covers all indoor and outdoor cable terminations used on alternating- current (AC) cables with laminated or extruded insulation rated from 2.5 kv through 765 kv. Cable terminations and component parts manufactured for these voltages shall be capable of withstanding the tests and requirements as specified in this Standard.

IEEE 81 - Guide for Measuring Earth Resistivity, IEEE 81 - IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System. The guide describes and discusses techniques for measuring ground resistance and impedance, earth resistivity, potential gradients from currents in the earth, and the prediction of the magnitudes of ground resistance and potential gradients from scale model tests. It also covers factors influencing the choice of instruments used and the techniques for various types of measurements. It includes the purpose of the measurements, accuracy required, type of instruments available, possible sources of error, and nature of the ground or grounding system being tested.

IEEE 82 - Test Procedure for Impulse... IEEE 82 - Test Procedure for Impulse Voltage Tests on Insulated Conductors. Insulated conductors in service are subjected to voltage surges from lightning, switching, and other sources. These surges vary widely in wave shape, magnitude, and frequency of occurrence. This procedure was developed to simulate in service conditions and is intended as a guide for impulse testing of cables and cables with accessories (cable systems). It can be used as a qualification or design test for cables and/or cable systems.

IEEE 83 - Test Procedure For Radial IEEE 83 - Test Procedure For Radial Power Factor Tests on Insulating Tapes in Paper-Insulated Power Cable. Procedure covers the method for testing and determining the radial power factor of insulating tapes of an oil impregnated insulated power cable. The power factor determines the insulating quality and condition of each insulating tape in a power cable system.

IEEE 100 - Authoritative Dictionary IEEE 100 - Authoritative Dictionary of IEEE Standards Terms Publication includes technical terms and definitions used in all IEEE standards and guides from several industries (Communications, Power, Information Technology, etc.. It also provides a list of the IEEE Standards and Guides.

IEEE 400 - Guide for Field Testing IEEE 400 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems. Guide lists various field test methods currently available or under development with a guidance on how to perform each test, along with advantages and disadvantages of each test. It covers shielded, insulated power cable systems rated from 5 kv through 500 kv.

IEEE 404 - Standard for Extruded IEEE 404 - Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2500 V to 500,000 V. Standard establishes electrical ratings and test requirements for cable joints used with extruded and laminated dielectric shielded cable rated from 2500 V to 500,000 V. It also defines a variety of common joint constructions. The standard is designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints to perform reliably in service.

IEEE 532 - Guide for Selecting and IEEE 532 - Guide for Selecting and Testing Jackets for Underground Cables Provides recommendations for the properties, characteristics, design, and testing of various types of cable jackets. The guide ensures that jacket materials are suitably specified for their intended applications. Also, jackets should provide a level of electrical, thermal, mechanical, and chemical durability to ensure that cable performance is reliable under normal use, and without danger to the user or surroundings.

IEEE 575 - Guide for the Application IEEE 575 - Guide for the Application of Sheath-Bonding Methods for Single-Conductor Cables and the Calculation of Induced Voltages and Currents in Cable Sheaths. Describes common sheath-bonding systems now in use and methods of calculating sheath voltages and currents, particularly as applied to three-phase systems operating at 60 kv and above, with the neutral grounded directly or through an impedance.

IEEE 592 - Standard for Exposed Semiconducting IEEE 592 - Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Insulated Connectors. Covers design tests for shield resistance and a simulated fault-current initiation for exposed semiconducting shields used on cable accessories, specifically joints and separable insulated connectors rated 15 kv through 35 kv.

IEEE 1142 - Guide for the Selection IEEE 1142 - Guide for the Selection, Testing, Application, and Installation of Cables having Radial- Moisture Barriers and/or Longitudinal Water Blocking Provides cable manufacturers and users with extensive information on design, testing, application, and installation of low, medium, and high-voltage power cables, as well as communication, control and instrument cables that make use of metal-plastic laminates as radialmoisture barriers. The guide also addresses additional means of protecting cables from the entrance of moisture through use of polymeric super absorbent materials for longitudinal water blocking of stranded conductors and other spaces within the cables.

IEEE 1299 - Guide for the Connection IEEE 1299 - Guide for the Connection of Surge Arresters to Protect Insulated, Shielded Electric Power Cable Systems. The guide suggests surge arrester installation methods at distribution cable terminal poles in order to minimize the total impressed transient voltage on medium-voltage distribution cables. Different protection schemes are included to assist the user in designing overvoltage protection for cable systems.

IEEE 1300 - Guide for Cable. IEEE 1300 - Guide for Cable Connections for Gas- Insulated Substations. The guide establishes typical dimensions for connections of a gas insulated substation (GIS) to extruded, self contained fluid filled and high pressure fluid filled (pipe type) cables in single and three phase arrangements for voltages 72.5 kv to 550 kv. Connecting a GIS to cables requires coordination of design, material, installation and test procedures of several manufacturers and designers. The guide provides detailed directions for such coordination.

IEEE 1333 - Guide for Installation of IEEE 1333 - Guide for Installation of Cable Using the Guided Boring Method. Considers the method and equipment involved in proper and economical installation of insulated conductors and/or conduits using the guided boring method. The method may be used to install insulated cable, cable preinstalled in conduit, or conduit alone.

IEEE 1406 - Guide to the Use of IEEE 1406 - Guide to the Use of Gas-In-Fluid Analysis for Electric Power Cable Systems. The purpose of this guide is to provide users of highpressure fluid-filled (HPFF) pipe cable systems and self-contained fluid-filled (SCFF) or Low Pressure Fluid Filled (LPFF) cable systems with the basis to establish the use of gas-in-fluid analysis for diagnostic purposes and as an operating maintenance tool.

IEEE 1425 - Guide for the Evaluation IEEE 1425 - Guide for the Evaluation of the Remaining Life of Impregnated Paper-Insulated Transmission Cable Systems. The guide provides technical information regarding factors that can affect the life of an impregnated paper insulated transmission cable system, and it reviews available methods to evaluate the remaining life of such systems and preventive maintenance to extend their service life.

IEEE 1511 - Guide for Investigating IEEE 1511 - Guide for Investigating and Analyzing Power Cable, Joint, and Termination Failures on Systems Rated 5 kv through 46 kv. Purpose of the guide is to provide an introduction to the concepts of failure analysis, how it can be used, and the value that can be obtained. The guide covers some commonly used methods employed in failure analysis and how these methods can be applied in determining the cause of failure of components used in construction of an underground power cable system. IEEE standards and guides can be obtained through GU s Library website.

Association of Edison Illuminating Companies Association of Edison Illuminating Companies (AEIC) was organized in 1885 to provide guidance to Edison illuminating companies within the USA. Initially, the organization s function was to license the illuminating companies to use Edison s inventions and patents. After the companies went their separate ways in 1895, AEIC became more of an electric industry association, seeking improvements to the technological aspects of the industry.

CS1-90 Specification for Impregnated CS1-90 - Specification for Impregnated Paper- Insulated Metallic-Sheathed Cable, Solid Type (11th Edition) Specification covers manufacturing and testing requirements that apply to impregnated paper insulated solid type power cables with metallic sheaths used at transmission and distribution voltages.

CS2-97 Specification for Impregnated CS2-97 - Specification for Impregnated Paper and Laminated Paper Polypropylene Insulated Cable, High Pressure Pipe Type (6th Edition) The specification covers manufacturing and testing requirements that apply to impregnated paper insulated and laminated paper polypropylene insulated cables for High Pressure Fluid Filled (HPFF) and High Pressure Gas Filled (HPGF) power cables.

CS3-90 Specification for Impregnated- CS3-90 - Specification for Impregnated-Paper- Insulated Metallic Sheathed Cable, Low Pressure Gas- Filled Type (3rd Edition) Covers manufacturing and testing requirements that apply to impregnated paper insulated low pressure gas filled type power cables with metallic sheaths used at transmission and distribution voltages.

CS4-93 Specification for Impregnated- CS4-93 - Specification for Impregnated-Paper- Insulated Low and Medium Pressure Self- Contained Liquid Filled Cable (8th Edition) Specification covers manufacturing and testing require-ments that apply to impregnated paper insulated low and medium pressure fluid filled type power cables with metallic sheaths used at transmission and distribution voltages.

CS8-07 Specification for Extruded CS8-07 - Specification for Extruded Dielectric Shielded Power Cables Rated 5 kv through 46 kv (2 nd Edition) Specification covers manufacturing and testing require-ments that apply to power cables 5 kv to 46 kv insulated with various types of crosslink polyethylene and ethylene propylene rubber insulated cables.

CS9-06 Specification for Extruded CS9-06 - Specification for Extruded Insulation Power Cables and Their Accessories Rated 46 kv through 345 kv ac (1st Edition) Specification evolved from CS7 and describes design and test requirements for solid dielectric cables with crosslinked polyethylene and ethylene propylene rubber insulated power cables rated above 46 kv through 345 kv voltage range. Note: AEIC CS7 was replaced by AEIC CS9

AEIC - CG1-07 Guide for Establishing CG1-07 - Guide for Establishing the Maximum Operating Temperatures of Impregnated Paper and Laminated Paper Polypropylene Insulated Cable (4 th Edition) Guide covers proper operating temperatures and operating temperature limits and the effects it has on the operation of the power cable with paper and paper laminated insulation.

CG3-05 Guide for Installation of CG3-05 - Guide for Installation of Pipe-Type Cable Systems (2nd Edition) Provides various construction techniques relating to the installation of HPFF and HPGF cable systems, including the following topics: General installation requirements Trenching and backfill requirements Steel pipe handling Installation instructions for coated steel pipes Installation instructions for pipe-type cable and accessories

CG4-97 Guide for Installation of CG4-97 - Guide for Installation of Extruded Dielectric Insulated Power Cable Systems Rated 69 kv through 138 kv (2nd Edition) Guide provides various construction techniques relating to the installation of extruded dielectric cable systems. It helps users prepare installation specifications for cables rated 69 kv through 138 kv voltage range.

CG5-05 Underground Extruded Power CG5-05 - Underground Extruded Power Cable Pulling Guide (2nd Edition) Guide outlines the pulling parameters that need to be considered when designing and installing power cables in duct. The guide covers extruded cables only.

CG6-05 Guide for Establishing the CG6-05 - Guide for Establishing the Maximum Operating Temperatures of Extruded Dielectric Insulated Shielded Power Cables (1st Edition) Guide covers proper operating temperatures and operating temperature limits and the effects it has on the operation of the power cables with extruded dielectric insulation.

CG7-05 Guide for Replacement and CG7-05 - Guide for Replacement and Life Extension of Extruded Dielectric 5-35 kv Underground Distribution Cables (1st Edition) Covers considerations that are addressed in pursuing courses of action available for cable replacement or cable life extension in power cables ranging from 5 kv through 46 kv.

CG8-03 Guide for an Electric Utility CG8-03 - Guide for an Electric Utility Quality Assurance Program for Extruded Dielectric Power Cables (2nd Edition) Describes techniques and procedures that can be used to establish a quality assurance program for extruded dielectric cables. These procedures will help ensure that the purchaser consistently receives cable as specified.

CG9-00 Guide for Installing, Operating... CG9-00 - Guide for Installing, Operating, and Maintaining Lead Covered Cable Systems Rated 5 kv through 46 kv (1st Edition) Guide covers the most common material and techniques associated with the installation and maintenance of paper insulated lead covered (PILC) cables.

CG10-02 Guide for Developing CG10-02 - Guide for Developing Specification for Extruded Power Cables Rated 5 through 46 kv (1st Edition) Guide describes the various choices that an engineer must consider when developing a cable specifications for cables ranging from 5 kv to 46 kv. The guide is also designed to familiarize the user with the criteria required to ensure the cable will perform as intended.

CG11-02 Guide for Reduced Diameter CG11-02 - Guide for Reduced Diameter Extruded Dielectric Shielded Power Cables Rated 5 through 46 kv (1st Edition) Guide covers design criteria that should be considered when specifying reduced diameter extruded dielectric power cables ranging from 5 kv to 46 kv. It also covers the effects reduced diameters cables will have on the accessories.

CG12-05 Guide for Minimizing CG12-05 - Guide for Minimizing the Cost of Extruded Dielectric Shielded Power Cables Rated 5 through 46 kv (1st Edition) Provides general information that can be used to reduce the initial cost of extruded dielectric cables rated at 5 kv through 46 kv. However, each design variable may have an effect on the performance of the cable and the cable accessories. AEIC publications can be obtained through the AEIC website: www.aeic.org

Insulated Cable Engineers Association (ICEA) Insulated Cable Engineers Association (ICEA) is a professional organization dedicated to developing cable standards for the electric power, control, and telecommunications industries. ICEA was founded in 1925, the members are typically cable manufacturers, engineers and consultants. A listing of key ICEA standards and guides related to the power cable industry are provided on the following slides.

ICEA P-45-482 - Short Circuit Performance ICEA P-45-482 - Short Circuit Performance of Metallic Shields and Sheaths on Insulated Cable. Equations and parameters have been established for short circuit calculations for sheaths or shields made of aluminum, bronze, copper, lead, steel, zinc and cuppronickel alloy. The types of sheaths or shields included are: Wires, applied helically, as braid or serving; or longitudinal with corrugations. Helically applied flat tape, not overlapped. Helically applied, overlapped, flat tape. Corrugated tape, longitudinally applied. Tubular sheath

ICEA S-81-570 600 Volt Rated Cables.. ICEA S-81-570 600 Volt Rated Cables of Ruggedized Design for Direct Burial Installation as Single Conductors or Assemblies of Single Conductors Standard applies to the materials, construction, and testing of single conductor cables and assemblies of completed single conductor cables used for distribution of electrical energy at phase-to-phase voltages not exceeding 600 volts or phase-to-ground not exceeding 480 V, and at temperatures not exceeding 75 C or 90 C, as applicable to the construction.

ICEA S-94-649 Concentric Neutral ICEA S-94-649 Concentric Neutral Cables Rated 5 kv through 46 kv. Standard applies to materials, constructions, and testing of crosslinked polyethylene, tree retardant crosslinked polyethy-lene and ethylene propylene rubber insulated single conductor or multiplexed concentric neutral cables rated 5 kv to 46 kv which are used for the transmission and distribution of electrical energy.

ICEA S-96-639 5-46 kv Shielded ICEA S-96-639 5-46 kv Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy. Applies to materials, constructions, and testing of 5,000 volt to 46,000 volt shielded crosslinked polyethylene, and ethylene propylene rubber insulated wires and cables which are used for the transmission and distribution in the electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground, or submarine.

ICEA S-97-682 Utility Shielded ICEA S-97-682 Utility Shielded Power Cable Rated 5 kv through 46 kv Standard applies to materials, constructions, and testing of crosslinked polyethylene, tree retardant crosslinked polyethylene and ethylene propylene rubber insulated single conductor or multiplexed shielded power cables rated 5 kv to 46 kv which are used for the transmission and distribution in the electrical energy.

ICEA S-108-720 Standard For ICEA S-108-720 Standard For Extruded Insulation Power Cables Rated above 46 to 345 kv. Applies to materials, constructions, and testing of crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated single conductor shielded power cables rated above 46 kv to 345 kv used for the transmission of electrical energy.

ICEA T-24-380 - Guide for Partial ICEA T-24-380 - Guide for Partial Discharge Test Procedure. Covers how to detect and measure partial discharges occurring in single and multi-conductor cables.

ICEA T-26-465 - Guide for Frequency ICEA T-26-465 - Guide for frequency of Sampling Extruded Dielectric Power, Control, Instrumentation, and Portable Cables for Test. Guide provides a combination of plans for the frequencies at which cable samples may be obtained for tests to determine conformance to appropriate requirements of ICEA Standards Publications. Valid statistical sampling frequencies other than those listed herein are acceptable if evidence of statistical control can be demonstrated. The guide applies only to extruded dielectric power, control, instrumentation, and portable cables.

ICEA T-28-562 - Test Method for Hot ICEA T-28-562 - Test Method for Hot Creep of Polymeric Insulations. Provides a procedure which is suited for determining the relative degree of crosslinking of polymeric, electric power cable insulations during manufacturing. ICEA publications can be obtained from the ICEA website: www.icea.net

International Electrotechnical Commission (IEC) The (IEC) International Electrotechnical Commission was founded in 1906 in London, England. IEC is the world s leading organization for the preparation and publication of International Standards for all electrical, electronic and related technologies, known collectively as electrotechnology. Key IEC standards and guides related to the power cable industry are listed in the following slides.

IEC 62067 Power cables with IEC 62067 Power cables with extruded insulation and their accessories for rated voltages above 150 kv (U m = 170 kv) up to 500 kv (U m = 550 kv) Test methods and requirements. Standard specifies test methods and requirements for power cable systems and their accessories with extruded insulation rated from 150 kv up to 500 kv.

IEC TS 60589 Cable connections for IEC TS 60589 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages 72.5 kv and above. Fluid-filled and extruded insulation cables Fluidfilled and dry type cable terminations. Specification covers the connection of cables into gas insulated metal enclosed switchgear for single or three phase cable arrangements for fluid filled or extruded cable systems. IEC publications can be obtained from the IEC website: www.iec.ch