Preloaded. PreciSAL. EZ Toric

Similar documents
Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Wide Diopter Range and Different Haptic Platforms

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Long-term quality of vision is what every patient expects

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

ROTATIONAL STABILITY MAKES THE DIFFERENCE

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Unique Aberration-Free IOL: A Vision that Patients

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

THE ASPHERIC PRELOADED INJECTION

Improving Lifestyle Vision. with Small Aperture Optics

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Evolution of Diffractive Multifocal Intraocular Lenses

I N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE

Clinical Evaluation 3-month Follow-up Report

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

PreciSAL Preloaded Lens System

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Intraocular lens Difficulties

COMPARISON OF THE MEDICONTUR 860FAB

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

Treatment of Presbyopia during Crystalline Lens Surgery A Review

FOR PRECISE ASTIGMATISM CORRECTION.

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Roadmap to presbyopic success

Clinical Update for Presbyopic Lens Options

Optical Perspective of Polycarbonate Material

Dr. Magda Rau Eye Clinic Cham, Germany

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Raise your expectations. Deliver theirs.

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

OPTICS BASIC. Course Objectives WELCOME!!! Refractive Error and How Spectacle Lenses Correct It. Basic Anatomy. Hyperopia - Far Sighted PTICS:

Headline. IOLMaster. Subline. The gold standard in biometry

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

Multifocal and Accommodative

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Technicians & Nurses Program

Clinical Evaluation 3-month Follow-up Report

HYDROPHILIC ACRYLIC ADVANCED POLYMER

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

OCULUS Pentacam AXL Always an Axial Length Ahead

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

The Dysphotopsia Mystery. John J. Bussa, M.D.

Ocular Scatter. Rayleigh Scattering

Refractive Power / Corneal Analyzer. OPD-Scan III

Fitting Manual Use with kerasofttraining.com

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

UIN: IOL Date of Prep: April Avansee Preload1P. Technical Slide Kit April 2017

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/16

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Optical Connection, Inc. and Ophthonix, Inc.

The complete choice in refractive lens solutions

Choosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS

HIGH DEFINITION VISION SOLUTIONS THE COMPLETE GUIDE TO LASER VISION CO R R EC T I O N

József Győry. Veszprem, Hungary

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Customized intraocular lenses

10/8/ dpt. n 21 = n n' r D = The electromagnetic spectrum. A few words about light. BÓDIS Emőke 02 October Optical Imaging in the Eye


Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Advanced Technology IOLs

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

Aberrations Before and After Implantation of an Aspheric IOL

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Design of a Test Bench for Intraocular Lens Optical Characterization

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

Fitting Manual Use with

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Advances in the design and

11/23/11. A few words about light nm The electromagnetic spectrum. BÓDIS Emőke 22 November Schematic structure of the eye

The Miracle of Pi in Eye. Rajesh Khanna, MD

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

The Aberration Structure of the Keratoconic Eye

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Surgical data reveals that Q-Factor is important for good surgical outcome

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

ISO Ophthalmic optics and instruments Instruments to measure axial distances in the eye

Transcription:

Preloaded PreciSAL EZ Toric

Experience the beauty with new vision Make a difference every time 1 Why you should choose MBI 3 Our vision is clear 4 PreciSAL quality 5 MTF of PreciSAL 7 Optical precision 8 Chromatic aberration 9 PreciSAL design 10 PreciSAL asphericity 12 PreciSAL results 13 EZ Toric the cutting edge difference 14 PreciSAL Yellow 16 Believing is seeing 17 PreciSAL 1-Piece IOL Yellow and Clear 18 PreciSAL EZ Toric 1-Piece IOL Yellow 19 PreciSAL 3-Piece IOL Yellow and Clear 20

Make a difference every time We believe perfect eyesight can be restored. It s not a theory, it s a reality. PreciSAL is an aspheric intraocular lens with negative spherical aberration. It will transform patients lives by giving them back what they thought was lost forever - clear, sharp vision. PreciSAL is a revolutionary new technology, proprietary to MBI. As people who care about eyesight, we want to see optimum results, and to see them consistently. We want the products we offer to be reliable and of the highest quality. We want to be certain we are helping you make a difference every time you treat someone. While some are content to use current technology, MBI embraces the forward thinkers of this world the people who are developing tomorrow s technology. We believe PreciSAL performs consistently during implant. PreciSAL MBI More than meets the eye 1

2 MBI More than meets the eye Our goal is to supply surgeons with the world s best hydrophobic acrylic IOLs.

Why you should choose MBI We delve for difference, we search for innovation, and we insist on world s best technology and precision manufacturing. We are committed to manufacture truly innovative products. But that s still not enough Our vision is truly focused on making a difference to people s lives. You will be inspired by MBI because you look for the highest quality and innovatiion in medical device. Our goals are built on supplying surgeons with the world s best hydrophobic IOLs PreciSAL (Precision Soft Acrylic Lenses). We deliver 0.25 Diopter precision (currently only in Australia). We believe our unique Material has no micro-vacuoles and no mie-scattering. We have outstanding contrast sensitivity and visual acuity. Our Products are easy to use. MBI is an FDA registered and ISO 13485 certified company located in Southern California. Since 1997, MBI has been engaged in the development, prototyping and manufacturing of innovative medical products. Nothing is outsourced. All work are carried out at MBI. By combining the Medicel preloaded Injector with MBI IOL s together, we offer an excellent injectable lens system to our customers. We not only meet the ISO standards, we try to exceed them. PreciSAL MBI More than meets the eye 3

Our vision is clear The proprietary material, unique manufacturing processes and better than ISO precision make PreciSAL a vastly superior product. In every way quality, precision, performance, usability and repeatability PreciSAL out-performs all other IOLs, and represents a significant advancement in ophthalmic surgery. By using the preloaded injector from Medicel, MBI offers an excellent and opimized system. Manufactured in 0.5 Diopter increments * to a tolerance of only ± 0.25D in a range from 0D 40D, you can be assured that what s labeled on the box is what s in the box. * Delivery range details on page 18,19,20. Preloaded PreciSAL 4 MBI More than meets the eye

PreciSAL quality PreciSAL Clear IOLs are made from a unique, soft, hydrophobic acrylic material, with less than 0.5% water content that incorporates the most desirable UV blocking properties. PreciSAL Yellow IOLs have the same benefits, with the addition of a proprietary blue-light filter. They behave much like hydrophilic lenses. They unfold and center perfectly, and position in the bag exactly where you want them, making them easy to implant. In fact, there is no need to change your implant technique PreciSAL lenses are intended to be inserted through a 2.2mm incision with MBI s Preloaded injectable lens system, or with the injection system of your choice. They are simply beautiful to use. MBI More than meets the eye 5

PreciSAL A High Definition IOL 6 MBI More than meets the eye

MTF of PreciSAL Modulation Transfer Function (MTF) is the most superior tool for objectively measuring visual acuity and contrast sensitivity. PreciSAL has an excellent MTF value (as high as 0.65), because of the high precision in manufacturing and the unique acrylic material of MBI. PreciSAL simultaneously offers both the advantages of enhanced visual acuity and good depth of focus. PreciSAL is a unique product for your patient. PreciSAL MBI More than meets the eye 7

Optical precision PreciSAL means using the best, not the adequate. We believe the current tolerance for error in IOL labelling (established by the International Standards Organisation) is obsolete, and significantly contributes to today s refractive errors. Take a 20 Diopter IOL, for example: 20D is written on the box, but the ISO tolerance allows for an error of ± 0.4D. The IOLs could actually be anywhere from 19.6D 20.4D. Added to this are the constraints of 0.5D steps, and the judgement involved in selecting the appropriate power. This creates the potential for a refractive error of up to ± 0.7D. The error can be even more significant with higher powered lenses. This means a patient could be given, quite unintentionally, IOLs that are almost a Diopter off target. We believe it s better to have the lens fit the patient, rather than the other way around. We believe that what s labeled on the box should be what s in the box. PreciSAL 8 MBI More than meets the eye

Chromatic aberration PreciSAL lenses have a high Abbe number. That s a good thing. The Abbe number, also known as the V number, is a measure of a transparent material s dispersion in relation to the refractive index, with high values of V indicating low dispersion (or low chromatic aberration). In optics, the Abbe number indicates material quality and the capacity of an IOL to focus all colours to the same point. A high Abbe number not only means less chromatic aberration, it means better contrast and optical performance. We are proud of our V number. PreciSAL lenses have an Abbe number of 50*. *Abbe number: Source of Abbe numbers except PreciSAL : Zhao H. Mainster M. J Cataract Refract Surg. 2007, Zhao H, et al. Presented at ESCRS 2009. IOL material with high chromatic aberration (low Abbe number) IOL material with less chromatic aberration (high Abbe number) MBI More than meets the eye 9

PreciSAL design The way an IOL performs is defined by how it is made. The general way Injection Moulding is used to make hydrophobic acrylic IOLs. This process can create micro cracks and spaces between the lens material polymer chains. Over time, water in the material, along with aqueous, may condense into these spaces, forming fluid-filled micro vacuoles. These glistenings may then create mie-scattering within the eye, causing a significant loss of contrast and a decline in visual acuity. The MBI way The PreciSAL manufacturing process is state-of-the-art. It s the MBI material and ultimate precision of our lathing technique, which makes PreciSAL exceptional. Since the launch of PreciSAL in 2008, no glistenings have been reported. 10 MBI More than meets the eye

It s also about finesse. The MBI innovative manufacturing process delivers a square edge all around the optic and the haptic areas. We believe that this square edge contributes to blocking cell migration and minimizing PCO. Engineered with a low glass transition temperature (Tg), PreciSAL is also designed for the operating room: from 11 C, the material becomes soft and easy to inject. No waiting, no pressure just simple smooth unfolding. The unique PreciSAL proprietary material has less than half the water content of most other hydrophobic acrylic materials, yet it remains soft and pliable for ease of implantation. PreciSAL hydrophobic acrylic lens (Tg:11 C) SEM picture with 1,000 x magnification, showing the 90 edge of the PreciSAL optic under the electron microscope. PreciSAL MBI More than meets the eye 11

ff PreciSAL asphericity Your patients want clear, crisp sight in all conditions day, night, dim or bright. We offer it with PreciSAL. Contrast sensitivity is particularly important in environments such as driving at night or dining in a dimly lit restaurant. Negative spherical aberration (-SA) improves vision in these situations, producing the best visual acuity and contrast sensitivity with a modest depth of focus. PreciSAL lenses have negative spherical aberration (-SA) in both clear (302AC) and yellow (302A) models. The residual SA is 0.21μm at a 6mm corneal diameter. PreciSAL 12 MBI More than meets the eye

gg PreciSAL results PreciSAL is available in 0.5 Diopter increments with a manufacturing tolerance of ± 0.25D, so you can give your patients exactly what their vision needs. In a recent Australian study* the sight of 100 consecutive PreciSAL recipients was tested 3 months after surgery, where 89% of these patients were within 0.5D of target refraction. The result is unprecedented. The patients overjoyed. Drs. Dosso and Dreifuss, fom Geneva Switzerland, have observed clinically that the mean rotation of their patients PreciSAL Toric IOLs is only 1.20 after 30 days. * Conducted by Dr. Peter Stewart, Lasersight Maroochydore (2013). Data available on file, MBI Lenses of ± 0.125D tolerance were used. Dr. Dosso s mean pre-operative target refraction was -0.80 across his patient profile and the mean post-operative refraction result was -0.87, where 86% of all eyes implanted with PreciSAL Toric IOLs were within 0.5D of target refraction. MBI More than meets the eye 13

EZ Toric 1,2 - The Cutting Edge difference Easy to use, with precise, reliable results. EZ Toric That s what PreciSAL EZ Toric lenses bring to you as a surgeon. What we try to do for patients is to correct their astigmatism, and bring them back to a world of color, contrast and clarity. The lathe-cut technology used to create PreciSAL lenses provides precision and clarity that we believe is unmatched in the world of ophthalmology. It s precision you can see. Less rotation We believe that the lens is easy to position and remains relatively stable once in position because of our manufacturing process. We believe that the MBI process provides a good coefficient of friction on the finished edges which, in turn, should facilitate a much better attachment of the capsular bag to the lens post-op to hold it in place. The precise quadrant lathing is intended to spread the lens power over a greater area and, therefore, should be far more forgiving of rotational misplacement. In conjunction with the intended improved attachment of the capsular bag, PreciSAL EZ Toric promotes lens positioning that is intended to be fail-safe. Greater accuracy / more capacity Both spheres and cylinders are available in 0.5 Diopter increments, providing our vision of great accuracy in treatment. Cylinders start at 1.0D, so you ll be able to treat the majority of people more effectively. The way we ve manufactured, the ease with which we perform, and the results we achieve, will take you and your patients to a new level of satisfaction. The figure above shows the quadrants of a PreciSAL EZ Toric IOL. The two steeper quadrants have increased curvature (added power) for the cylinder, and blend crisply with the flatter (reduced power; marked with three dots) quadrants. The cylinder quadrants have a straight and minimal transition zone to the sphere, meaning the cylinder correction covers up to 85 of the available 90 surface. The quadrants also extend to within 0.5mm of the optic edge, so the power is more precise across a significantly greater area from competing Toric IOLs. PreciSAL EZ Toric is more forgiving of both rotation and off-axis implantation, as well as providing a crisp, clear astigmatic correction. 1: continued european clinical study 2:Trade Mark Pending 14 MBI More than meets the eye

EZ Toric MBI MBI The mean preoperative keratometric cylinder was 2.41D (range 1.5 to 3.25) and the postoperative refractive cylinder was 0.44 (range 0 to 0.75) At day one, the mean axis misplacement was 6.3 (range 0 to 12 ). At one month, the mean IOL rotarion was 1.2 (range 0 to 3 ). None of the IOLs required realignment....the good tolerance of some axis misplacement of MBI EZ Toric IOL allows achievement of excellent postoperative visual outcomes. OTHER OTHER The superior manufacturing capability of the MBI EZ Toric lens is compared to other manufacturer in the above topography and histogram. The transition edge between cylinder and sphere is much better defined by the MBI PreciSAL EZ toric IOL. Note: Presented at 2017 ESCRS Meeting in Lisbonne by Andre Dosso, M.D., Geneva, Switzerland. PreciSAL MBI More than meets the eye 15

PreciSAL Yellow PreciSAL Yellow is not the yellow lens you think it is. It looks different because it is different. PreciSAL Yellow gives your patients the clarity and filtering properties equivalent to the lens of a 4½ year old. They will see in all kinds of visible light clearer, crisper and more colourfully and they will sleep better. The high-energy filter protects the macula from cytotoxic violet light. However, it doesn t block all the benign blue wavelengths (440nm 500nm) that contribute significantly to the body s sense of diurnal rhythm, effective dim-light vision, colour perception and circadian photoreception. 1 With PreciSAL Yellow, MBI achieve this with transmission values of 78% 94% (440nm 500nm) compared to the industry standard of 32% 81%. Therefore, PreciSAL Yellow more accurately replicates the spectral transmission of a normal, healthy eye. Spectral sensitivity of photoreception and spectral transmittance of IOLs 2 S-cone (lmax z 420 nm), circadian (lmax z 460 nm), aphakic scotopic (lmax z 500 nm) and photopic (lmax z 555 nm) spectral sensitivities, where lmax is the wavelength of peak spectral sensitivity The spectral transmittances of [PreciSAL 302A (20D)], a UV-blocking (AMO Tecnis Z9002 20D), and a blue- blocking (Alcon AcrySof Natural SN60AT 20D) IOL are also shown. We believe your patients will see better and sleep better their lives will be transformed. 1 Except the MBI spectral transition curve, source of graphic: Mainster M.A., Turner P.L.: Blueblocking IOLs Decrease Photoreception Without Providing Significant Photoprotection, Table 1. Surv. Ophthal. 55(3) May- June 2010 p 273. 2010 2,3,4 Reprinted from Survey of Ophthalmology, Vol 55, Number 3, May-June 2010, Mainster M.A., Turner P.L.: Blue-blocking IOLs Decrease Photoreception Without Providing Significant Photoprotection, pp 274 275. Copyright 2010, with permission from Elsevier. PreciSAL 16 MBI More than meets the eye

Believing is seeing Spectral dependence of phototoxicity 3 The action spectra for UV-blue phototoxicity and RPE lipofuscin phototoxicity are quite similar. Both increase rapidly with decreasing wavelength. Thus, UV-radiation is much more hazardous than violet light, which in turn is more hazardous than blue light. Acute blue-green retinal phototoxicity has an action spectrum similar to scotopic sensitivity [where it] peaks around 500 nm (blue-green) and decreases at shorter and longer wavelengths, as depicted in this figure by the absorption spectrum of rhodopsin. We believe perfect eyesight is achievable. We believe that 0.5D precision, ± 0.25D tolerance, no glistenings will transform people s vision. We believe you can experience an unprecedented refractive accuracy, with up to 89% of patients being within 0.5D of target, because it s been shown across a study* of 100 consecutive patients in Australia. We believe in embracing better ways, where attention to detail is unique. In hundreds of thousands implants, no glistenings were reported. We believe PreciSAL will change the way you think about cataracts and give you the confidence to perform lifechanging surgery, to believe in seeing, and restore what was thought lost. Age-related sensitivity (relative to a 10 year old phakic eye) 4 Acute retinal phototoxicity risk (UV-blue phototoxicity), scotopic sensitivity (rod photoreception) and circadian photoreception (melatonin suppression) for phakic eyes ( crystalline lens ) relative to a 10-yearold phakic eye, taking into consideration age-related decreases in crystalline lens transmittance and pupil area and increases in RPE cell phototoxicity consistent with the age-related accumulation of lipofuscin. * Conducted by Dr. Peter Stewart, Lasersight Maroochydore (2013). Data available on file.mbi Lenses of ± 0.125D tolerance were used. MBI More than meets the eye 17

PreciSAL 1-Piece IOL Yellow and Clear IOL design Material Model UV cut off at 10% T ( 20D) Material water content <0.5% Refractive index 1.5 Abbe number 50 Optic design Haptic design Optic diameter Overall diameter Haptic angle 0 Diopter range Manufacturer s A-constant Aspheric single piece posterior chamber lens UV Absorbing or UV+Blue Light Filtering Hydrophobic Acrylic Polymer Preloaded: P302AC(uv) and P302A(uv+ blue light filter) Non preloaded: 302AC(uv) and 302A(uv+blue light filter) 386nm ± 2nm (302AC), 388nm ±2nm (302A) Biconvex, square edged optic and haptic Modified C-Loop 6.0mm 13.0mm Available in powers from 0.0D to 30.0D: 0.0D-10.0D in 1D steps 10.0D-30.0D in 0.5D steps 118.7 (for contact and immersion biometry) Recommended A-constant * ACD 1 Method of sterilization Recommended Insertion Instrument SRK II: 119.2 SRK-T: 118.9 sf: 1.75 [Holladay I] HAIGIS: [a0: 1.32, a1: 0.40, a2: 0.10] 5.337 [Holladay II]; 5.51 [Hoffer Q]; 5.51 [Manufacturer] Ethylene Oxide (ETO) A suitable Preloaded Injector (Medicel) Non Preloaded: Medicel AG: Accuject LP604535 or ASB2200, 2.2-2.4mm Incision MDJ: Mini Glider, 2.2mm Incision, cartridge Mini B 1: These values are shown as guidelines only for use with optical biometry for calculation of implant power. MBI recommend that surgeons develop their own values based on individual technique, measuring equipment and desired post-operative results. In no way are these values meant to be definitive. PreciSAL 18 MBI More than meets the eye P r e l o a d e d P302AC 302AC P302A 302A CE0459

PreciSAL EZ Toric 1-Piece IOL Yellow IOL design Material Model UV cut off at 10% T Material water content <0.5% Refractive index 1.5 Abbe number 50 Optic design Optic diameter Overall diameter Haptic angle 0 Spherical equivalent range Cylinder range Manufacturer s A-constant Toric Aspheric single piece posterior chamber lens UV+Blue Light Filtering Hydrophobic Acrylic Polymer Preloaded : PT302A Non Preloaded: T302A 388nm ± 2nm Toric, biconvex, square edged optic and haptic 6.0mm 13.0mm Available in spherical equivalent powers from 10.0D to 30.0D 0.5D steps 1.0D to 6.0D in 0.5D steps 118.7 (for contact and immersion biometry) Recommended A-constant * ACD 1 Method of sterilization Recommended Insertion Instrument SRK II: 119.2 SRK-T: 118.9 sf: 1.75 [Holladay I] HAIGIS: [a0: 1.32, a1: 0.40, a2: 0.10] 5.337 [Holladay II]; 5.51 [Hoffer Q]; 5.51 [Manufacturer] Ethylene Oxide (ETO) A suitable Preloaded Injector (Medicel) Non Preloaded : Medicel AG: Accuject LP604535 or ASB2200, 2.2-2.4 mm Incision MDJ: Mini Glider, 2.2mm Incision, cartridge Mini B 1: These values are shown as guidelines only for use with optical biometry for calculation of implant power. MBI recommend that surgeons develop their own values based on individual technique, measuring equipment and desired post-operative results. In no way are these values meant to be definitive. MBI Toric Calculator: www.mbius.com/en/calculator.php Barrett Toric Calculator: www.ascrs.org/barrett-toric-calculator P r e l o a d e d PT302A T302A CE0459 MBI More than meets the eye 19

PreciSAL 3-Piece IOL Yellow and Clear IOL design Material Model UV cut off at 10% T Material water content <0.5% Refractive index 1.5 Abbe number 50 Optic design Haptic design Haptic material Aspheric three piece posterior chamber lens UV Absorbing or UV+Blue Light Filtering Hydrophobic Acrylic Polymer Models 300AC(uv) and 300A(uv+ blue light filter) 386nm ± 2nm (300AC), 388nm ± 2nm (300A) Biconvex, square edged optic and haptic C-Loop PMMA Manufacturer s A-constant Recommended A-constant * ACD 1 Method of sterilization Recommended Insertion Instrument 118.3 (for contact and immersion biometry) SRK II: 118.9 SRK-T: 118.7 sf: 1.61 [Holladay I] HAIGIS: [a0: 1.26, a1: 0.40, a2: 0.10] 5.337 [Holladay II]; 5.51 [Hoffer Q]; 5.39 [Manufacturer] Ethylene Oxide (ETO) Medicel Naviject Injector Model LP604405, Incision 2.8mm MDJ, Model MEPLAT with 00264 cartridge, Incision 2.8mm 1:These values are shown as guidelines only for use with optical biometry for calculation of implant power. MBI recommend that surgeons develop their own values based on individual technique, measuring equipment and desired post-operative results. In no way are these values meant to be definitive. Optic diameter Overall diameter 6.0mm 13.0mm Haptic angle 8 Diopter range Available in powers from 0.0D to 30.0D: 0.0D-10.0D in 1D steps 10.0D-30.0D in 0.5D steps 300AC 300A CE0459 20 MBI More than meets the eye

Experience the beauty with new vision PreciSAL MBI More than meets the eye 21 MBI Product Catalog Brochure P/N 001-000-021 Rev L, CN 941, Date: 03-19-2018

Millennium Biomedical Inc. 360 E. Bonita Ave., Pomona CA 91767, USA Phone +1 (909) 621-7646 Fax +1 (909) 621-7556 Email mbi@mbius.com Web www.mbius.com www.facebook.com/mbiiol International Sales Germany Office Email rg@mbius.com