Wing Gate Instructions. Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016

Similar documents
Aqua-Gen 3BR INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

Installers guide Deadbolt 02.

SA-320 Installation Guide SA-320. Installation Guide. Date: Mar, 2011 Version: 2.5. All Rights Reserved

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

YDL100SF USER M A N U A L. Smart-Ashley. Smart-Ashley. Y D L S F N a m e and C a u t i o n. A u t u e n t i c a t i o n T y p e

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

SA-320 Installation Guide SA-320. Installation Guide. Date: June, 2007 Version: 2.2. All Rights Reserved

CA80 Series Vari-Angle IR Illuminator

OPERATION MANUAL MOB 112

Technical data. General specifications. Measurement range min max. 360

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Radio Control Installation and Operating Instructions System 4

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK

USB-TC Instructions. Description

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

Overview of types. Technical data

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

Wireless Occupancy Sensor User Guide

Wireless Pressure Station with Backlight

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND)

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Senior Swing. Caution

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

RIGGING MANUAL English

INSTALLATION INSTRUCTIONS

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

with Light Level, Isolated Relay and Manual On features

Micro Wizard Instructions K1 KIT ASSEMBLY INSTRUCTIONS With Remote Start Switch

BH series Paddle joystick controllers

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

FD 125 Large-Format Card Cutter

200 RTH OFF ON IN OUT ALARM RESET

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

Operation Manual February Opticom Infrared System

F10F Series Wide band booster User s Manual

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F

Steele TV Stand Stock # BH

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

Crosby & Bown. Motorised Projection Screen. User Guide. Thank you for purchasing a Crosby and Bown projection screen

Blue Point Engineering

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Installation Instructions For Profile Series v.g1 Exit Device

RT200 Series Single-axis Industrial Joystick. RunnTech

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

Disclaimers. Important Notice

BL series Miniature paddle joystick controllers

Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

R PROFLAME Instruction Book Collection

34112-TE 8-digit LED Frequency Counter Module Model PLJ-8LED-C User Manual V 1.0 May 2014

General-Purpose Photoelectric Sensor

MODEL 1703E THE CHAMBERLAIN ARM TM INSTALLATION INSTRUCTIONS To be used in conjunction with the Lift-Master Garage Door Operator Owner's Manual

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

DICTATOR RTS Tube Door Closer

8V General information. 2 Order data 8V

Ford Pick Up Rear leaf Spring Kit Installation Instructions

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Wall Mount Bracket YM-81

USERS GUIDE EAGLE SMR MOTION SENSOR

Absolute Encoders - Singleturn

Note: This assembly instruction will cover all configurations of Alloy adjustable height double bases.

Model:CB-MRC. Instruction Manual of Mini Recessed Motorized Screen

RBP-1215B-RX DODGE RAM QUAD CAB RX3

UR3 Coin Validator rel. 1.3 UR3 MDB-Executive Coin Validator rel. 1.2 UR3 T Coin Validator rel User and Maintenance Manual

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

HYDRO-TOWER INSTALLATION INSTRUCTIONS

S E L E C T I O N. Arm Curl. User manual

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Installing Your Electronic Deadbolt

(Build Instructions)

Expandable Series Wireless Multi Unit Doorbell System

( F L O W I Z F A M I L Y )

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

MegaPoints Controller

INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09

QDV120 Operation and Pointing manual

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

STX Stair lighting controller.

Absolute Encoders Multiturn

WPR400 Wireless Portable Reader

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Device Manual Chapter 4.1-R optosonic u 3 radio net

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

Transcription:

Wing Gate Instructions Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016

Contents Chapter 1 Overview... 2 1.1 Product Model and Appearance... 2 1.2 Features... 3 1.3 Technical Parameters... 4 Chapter 2 Power-on Test Prior to Installation... 5 Chapter 3 Electric and Civil Installation... 6 3.1 Device Installation Conditions and Installation Position... 6 3.2 Cable Installation... 6 3.3 Device fixing and Installation... 7 3.4 Card Swiping Guard Lines... 9 Chapter 4 Device Wiring and Commissioning... 10 4.1 Function Description of Terminals on the Gate Control Board... 10 4.2 Wiring Diagram of the Controller... 11 4.3 Connection Cables Between the Master Chassis and the Slave Chassis... 11 4.4 Wiring Diagram of the Access Control System... 12 4.5 DIP Switch Functions and Setting... 12 4.5.1 Setting Gate Opening Duration... 12 4.5.2 Setting the Passage Direction Indicator... 13 4.5.3 Setting the Color of Wing Arm Indicators... 13 4.5.4 Passage Status... 13 4.6 Commissioning of the Standard Machine... 13 Appendix 1 Factory Defaults... 15 1

Chapter 1 Overview The wing gate is composed of a chassis, core component, wing arms, Printed Circuit Board (PCB), infrared sensors, read head, and access control system. The system uses standard electric interfaces. It meets fire-fighting passage requirements and is equipped with dedicated fire control linkage interfaces. The entire system complies with the same quality standard to ensure reliability, stability, and smoothness of the system during operation. The wing gate is applicable to work attendance, access control, consumption management, and special passage control of enterprises and institutional organizations. It is conducive to management of ticket check passages in stations, wharfs, convention and exhibition centers, and swimming pools. 1.1 Product Model and Appearance Sharp-angled Wing Gate FB1000 & FB1200 Oval Wing Gate FB3000 & FB3200 In the preceding models, FB1200 and FB3200 are dual-passage wing gates, as shown in the middle of the preceding figures; FB1000 and FB3000 are single-passage wing gates, as shown on both sides of the preceding figures. Note: The functions, installation methods, wiring, commissioning, and wiring diagrams of all models are the same. This document uses sharp-angled wing gates FB1000 & FB1200 as an example for description. 2

1.2 Features Power-ON self-test: The device automatically tests whether functions are normal during power-on or restart. Humanized passage indicators: When the wing gate is closed in standby mode, the indicator of the wing gate delivers a static light (a dual in-line package (DIP) switch is provided for selecting red light or green light). When the wing gate is opened, the green indicator is turned ON and on the opposite passage red indicator indicating access forbidden is turned ON. Any false action will trigger the red indicator and the generation of an audible alarm. The software-based access control mode is used in perfect combination with visual alarms. Passage mode setting: A DIP switch is available to set one-way passage, two-way passage, and free passage (wing arms collapsed). Automatic reset function: If no person passes through the wing gate within the specified period of time after the wing gate is opened, the system automatically closes the wing gate. The default duration is 5 seconds. The pass-through duration can be set by using a DIP switch. For details, see 4.5.1 "Setting Gate Opening Duration." Infrared anti-pinch and anti-bump functions: Four pairs of infrared sensors are installed inside the anti-pinch and anti-bump area (close to the wing arm movement area). When the infrared sensor detects a person or object in the anti-pinch area, the wing arms automatically stop the action and continue the action after the person or object leaves the anti-pinch area. Audible and visual alarms: The system generates alarms in any of the following cases: illegal break-in, reverse pass-through, pass-through timeout, and illegal signal input. Fire control function (optional): The fire linkage alarm function can be configured to open the wing gate. Counting function (optional): The system automatically collects statistics of pass-through persons and displays the statistical results using LEDs in a visualized manner. Fire control function (optional): When a power failure occurs, the wing gate automatically opens and no storage batteries are required. The wing arms retract into the chassis by virtue of the elastic force and the passage is open for crowd evacuation. This function better resolves the problem that the wing gate cannot be opened due to a power failure caused by storage battery aging. The wing gate is equipped with a read head conversion board, which allows replacing different types of read heads easily. The wing gate can be connected to an ON/OFF button or remote controller, which is set to normally open to meet requirements of different sites. Anti-follow function: After receiving a legal signal, the device opens the wing gate. After a person passes through the wing gate, the device judges that a follow event occurs and generates an audible and visual alarm if another person follows the person ahead. 3

1.3 Technical Parameters Overall dimensions (mm) FB1000 / FB1200: L = 1400, W = 300, H = 1008 FB3000 / FB3200: L = 1212, W = 316, H = 1017 Outer package dimensions (mm) FB1000 / FB1200: L = 1440, W = 365, H = 1072 FB3000 / FB3200: L = 1257, W = 365, H = 1090 Net weight of FBX000 series FB1000: 156 kg Net weight of FB1200: 103 kg (master machine + slave FB3000: 138 kg FBX200 series FB3200: 93 kg machine) Length of wing arms 260 mm Input voltage AC 100 V ~ 240 V, 50 Hz ~ 60 Hz Input control signal ON/OFF signal Output voltage DC 24 V 5 A, DC 12 V 3 A Wing gate ON/OFF duration 1s Rated power Standby mode: 60 W; gate-opening working mode: 150 W Ambient temperature range -28 C to +60 C Pass-through speed 25-30 persons/min (normally closed mode) Average failure-free operation count 5 million times Relative humidity 5% to 80% Indoor and outdoor (It Number of infrared correlation Operating 4 pairs is recommended that a tubes environment canopy be set up.) 4

Chapter 2 Power-on Test Prior to Installation Test Procedure 1 Connect a temporary test cable to the device and supply the input power of AC 100-240 V adaptive to the device (Note that a ground cable must be connected.) 2 Wait 30 seconds till the wing gate completes the self-test procedure. 3 Start the air switch inside the wing gate to check whether the wing gate and the LED indicators functions properly. If they all function properly, then start the civil installation. If an exception occurs, contact your sales agent. Figure 2-1 Air Switch 5

Chapter 3 Electric and Civil Installation 3.1 Device Installation Conditions and Installation Position The ground foundation for installation must be a concrete structure to ensure that expansion screws can be fastened securely. If the ground foundation does not meet this condition, consult professional building or decoration personnel and create stable conditions for reliably fastening the wing gate, for example, drive piles or lay out steel plates. Determine the device installation position. Determine the installation position based on the space proportion of the wing gate by referring to Figure 3-1A, Figure 3-1B, and Figure 3-2. Determine the installation scheme and build one or multiple intelligent management passages. When a wing gate is installed against the wall, reserve 100 mm space for opening the upper cover of the wing gate for maintenance and commissioning. The master machine and slave machine of the FB1000 wing gate form a passage, as shown in Figure 3-1A. Two FB1000 wing gates and one FB1200 wing gate can be installed to form dual passages, as shown in Figure 3-1B. The unit of data in the figures is mm. 60 300 260 260 300 100 300 260 60 260 300 260 60 260 300 100 Figure 3-1A Single-Passage Wing Gate Figure 3-1B Dual-Passage Wing Gate 3.2 Cable Installation For the outlet of concealed cables, see the installation hole positions of the FB1000 wing gate in Figure 3-2. The device uses 3 x 1.5 mm²cables with the voltage input range of AC 100-240 V as the power supply cable (including ground cables) and 4 x 0.5mm²shielded cables or RJ45 network cables as the signal cable. The power cable and signal cable must be laid out independently to prevent communication interference.. The power cable (strong current) and the signal cable (weak current) are laid out through different rubber hoses. Only professional electricians are allowed to wire the wing gate and a ground cable must be connected for the wing gate. A dedicated ground cable binding post is provided on the inner bottom side of the chassis, to ensure that the ground cable at the far end is grounded reliably. 6

3.3 Device fixing and Installation Procedure 1 Power ON the master machine and slave machine, adjust the wing arms to ensure that the wing arms are in the same line and the distance between the wings is 60 mm. Make the wings to be in the OFF state. 2 Test whether the infrared frays transmitted by infrared sensors on both sides align with each other. 3 Make marks: Mark the screw hole centers of the base and chassis base edges on the ground. 4 Drill holes: Move away the chassis, get ready a hammer drill and a 14 mm drill bit, and vertically drill a hole with the depth of 80 mm in the screw hole center marks. Alternatively, drill holes according to installation hole positions. For FB1000/2000/3000/4000/5000 devices, see Figure 3-2A for installation hole positions. For FB3000 devices, see Figure 3-2B for installation hole positions. The unit of data in the figures is mm. Expansion screw Figure 3-2A 7

Figure 3-2B 5 Apply screw glue to the outer surface and threads of the expansion screws, insert expansion screws, and fix the master machine and slave machine in the marked positions. Use a level checker (or spirit level) to check whether the installation ground foundation is in correct level. If not, use a pad for adjustment. Note: Eight expansion screws must be completely inserted, as shown in Figure 3-3. Figure 3-3 8

3.4 Card Swiping Guard Lines It is recommended to set guard lines to prompt the users to swipe cards outside the guard lines, as shown in Figure 3-4. Figure 3-4 9

Chapter 4 Device Wiring and Commissioning 4.1 Function Description of Terminals on the Gate Control Board Figure 4-1 10

The functions of terminals in areas are described as follows: Wing arm indicator: passage indicator Left/Right passage indicator: the sers judge whether they can pass through the wing gate based on the passage indicators. If green indicator is turned ON, they can pass through the wing gate. If red indicator is turned ON, they are not allowed to pass through the wing gate. Counter or Facial Terminal: This area can be connected to fingerprint readers, card readers, Facial Terminal, and other devices. Gate opening area: The terminal in this area controls the wing arms for allowing users to pass through. Area 1: The terminal in this area detects whether passengers enter the passage area and judges whether an illegal break-in occurs. Area 2: After passengers pass through area 2, the wing gate starts the wing arm closing procedure. The terminal in this area judges whether passengers pass through the wing gate to prevent pinch. Area 3: After a user passes verification, the wing gate is opened. The terminal in this area also judges whether a user breaks in from the opposite side. A DIP switch can be used to set this area as an anti-pinch function area. Right point 0/1: The terminal here detects the ON/OFF state signal of the wing arms. Point 0 indicates the OFF state and point 1 indicates the ON state. GND, +24 V: The terminal here is connected to an external power supply. Motor: The terminal here converts the electrical energy into mechanical movement of the wing gate. 4.2 Wiring Diagram of the Controller 4.3 Connection Cables Between the Master Chassis and the Slave Chassis Three 6-core connection cables (totaling 18 cores) are deployed between two wing gates. On the wiring terminal of the slave machine, there is a white transparent ruler marked with terminal numbers (1-20). Complete the wiring according to the following table. 11

CILK2 Optical Coupler for Gate Opening of Slave Machine + Optical Coupler J-MD2 Output End (Magnetic for Gate Closing of Slave Machine + Pass-through Indicator + Side Read Head (Yellow 6 Pins) (Motor) Lock) Indicator Polarity +24 V GND +24 V GND NC1 NC2 +24 V GND +12 V RX GL GR L2R L2G Terminal No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Small Line Color Red Black Green White Yellow Orange Red Black Green White Yellow Orange Red Black Green White Yellow Orange Cable Color Black (6 pins) Red (6 pins) Green (6 pins) 4.4 Wiring Diagram of the Access Control System Figure 4-3 Note: The duration of the lock driver needs to be set to 1s or 0s for the access control device and access controller, and the door magnet status is none. 4.5 DIP Switch Functions and Setting Figure 4-4 Pin K1-1 K1-2 K1-3 K1-4 K1-5 K1-6 K1-7 K1-8 Function Gate opening Passage Wing arm indicator Passage Idle Setting duration direction setting color in standby mode closed Default Value 1 1 1 0 1 0 0 0 4.5.1 Setting Gate Opening Duration Gate opening duration refers to the time range from wing gate opening to wing gate closing when a user passes verification but does not pass through the wing gate. DIP switches K1-1, K1-2, and K1-3 are used for setting the duration, which ranges from 5s to 60s. See the following table. 12

Switch Status Duration Switch Status Duration 111 5s 011 30s 110 10s 010 40s 101 15s 001 50s 100 20s 000 60s 4.5.2 Setting the Passage Direction Indicator The passage direction indicator is used to prompt a user whether the passage is passable. The green arrow indicates passable and the red "X" indicates access forbidden. The DIP switches K1-4 and K1-5 control the passage direction indicator. See the following table. K1-4 K1-5 Passage Direction 0 1 Two-way passage 1 0 One-way passage on the right side (towards the front cover opening direction) 1 1 One-way passage on the left side (towards the front cover opening direction) 0 0 Invalid setting 4.5.3 Setting the Color of Wing Arm Indicators The wing gate allows selecting different standby state colors, including green and red. That is, the wing arm indicator can be set to green or red to indicate whether the wing gate is in standby state. K1-7 Color of Wing Arm Indicator in Standby Mode 0 Green 1 Red 4.5.4 Passage Status You can set the passage status in standby mode. K1-8 Selection of Anti-pinch or Anti-follow Function 0 Anti-pinch function 1 Anti-follow function Note: In the normal working state, turn K1-8 to 0 to enable the anti-pinch function. 4.6 Commissioning of the Standard Machine The default duration is 5s for the wing gate from opening to closing. The standard machine can be commissioned using three methods: Manual commissioning Short-circuit K1 and GND to open the left passage. Short-circuit K2 and GND to open the right passage. User registration commissioning on the access controller software 1 Connect to access control software, register users and grant permissions to users, verify 13

users, check and commission whether the wing gate runs properly. 2 Trigger access controller to open and close the door, and check whether the wing gate runs properly. Commissioning of the integrated access control machine Check that lines are connected correctly, power on the wing gate, register users on the integrated access control machine, and check whether the wing gate runs properly. Commissioning of the two-way switch with automatic reset (optional) The two-way switch with automatic reset is optional for the wing gate. Open the cover in the control board installation position of the wing gate. The gate opening signal input end (J7) can be connected to a two-way switch. After the wing gate is powered ON, press the two-way switch to check whether the wing gate runs properly. 14

Appendix 1 Factory Defaults Category No. Function Default Setting 1 Lock drive duration 1s For access control devices with the attendance count function, the door magnet status is normally closed; for Access 2 Door magnet status access control devices without the attendance count control function, the door magnet status is none. system 3 Access control delay 1s 4 Communication with the access control device TCP/IP: 192.168.1.201 1 Gate opening duration The gate opening duration of the wing gate is set to 5s when no user passes through the wing gate after the user passes verification. (K1-1 = 1, K1-2 = 1, K1-3 = 1) Wing gate Passage direction 2 system indicator Two-way passage (K1-4 = 0, K1-5 = 1) 3 Wing arm indicator color in standby mode Green (K1-7 = 0) 4 Passage status in standby mode Closed (K1-8 = 0) 15