6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

Similar documents
Level Measurement. GDSL Series. Ultrasonic Level Sensor

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

OEM radar transmitter, for aggressive media level measurement

MP Series Radar Transmitter Installation & Operation Manual

Radar Level Measurement micropilot FMR 130 for stilling wells

SITRANS LR 300: High Performance Radar for Level Measurement

Micropilot M FMR250. Technical Information

RADIATED MICROWAVES. Application. Working frequency. 6 GHz Band C 6 GHz Band C. Working temperature C C.

Rosemount 5408 and 5408:SIS Level Transmitters

Ultrasonic level meters ULM 70

Level Measurement Continuous level measurement Radar transmitters

Main features. Operation. LEVEL Transmitters

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

REFLEX RADAR INDICATOR

TGF2200 Micro Pulse Level Meter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level measurement Radar

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

OPTIWAVE 7300 C Supplementary instructions

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Ult r a s o n i c le v e l me t e r s ULM 70

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement With REFLEX RADAR

FOSTEN AUTOMATION SÉRIE F500-RD

Global Water Instrumentation, Inc.

Ultrasonic level measuring device, non-contact

Level Measurement Continuous level measurement Radar transmitters

Level Measurement With REFLEX RADAR

Ult r a s o n i c le v e l me t e r s ULM 55

Propagation of Electromagnetic Waves

Xperience The Future in Level Measurements

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Ambient Conditions. Operating Conditions. Pressure

ED701 General Industry Pressure Transmitter

Rosemount 5400 Series Radar Level Transmitter

The transducer component converts the measured signal and displays the actual value.

LR10, LR15, LR20, LR25 & LR30 Series Manual

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Digital inductive conductivity transmitter

OPTIWAVE 1010 Technical Datasheet

analytical bulk flow distance flow LEVEL pressure temperature industrial communication

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Magnetostrictive Level Transmitter

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Ultrasonic level transmitter, non-contact

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

PAD - Heavy Duty Differential Pressure Trasmitter

U Series Non-Contact Ultrasonic Transmitter

Smart Radar Level Transmitter ALT6200 Overview Features Specification

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

Serie NW - Acoustic Wave. Option list. Applications / Overview

INLINE flowmeter for continuous flow measurement

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Installation guide 971 SmartRadar LTi

Level Measurement Products Installation Considerations-Radar

NCR-80. BinMaster Price Book binmaster.com Subject to change without notice 1

MaxxFlow HTC Flow measurement for dry bulk solids

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

SATRON VB Pressure Transmitter

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

RPL Radar level transmitter K group

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

Field indicator for current loops with HART communication Models DIH50, DIH52

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Technologies, Solutions, and Applications. Level Switching

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

JTR Guided Wave Radar Level Transmitter.

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

Digital conductivity transmitter

Submersible pressure sensor For oils and fuels Model LF-1

Metal tube variable area flowmeters for gases, liquids and steam

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Ultrasonic level indicator type INOWAFE

JFR Series FMCW Radar Level Transmitter.

DRS390 High stability, flange mounting

EchoPro. LR11, LR16, LR21, LR26 & LR31 Series Manual. Intrinsically Safe Radar Level Transmitter

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

ATG SERIES Growco Servo Tank Gauges

analytical bulk flow distance flow LEVEL pressure temperature industrial communication

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

INSERTION paddle wheel flowmeter for continuous flow measurement

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

TGR Wire Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

Transcription:

6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES

Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument Commissioning...8 6 Structure Size...9 7 Technical Parameters...12 8 Meter Linearity...13 9 Product Model Selection...16 Material level meter selection parameter table...22

26GHz Radar Level Meter 1. Product Overview This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 80 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment. Principle Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous). A Range set B Low adjustment C High D Blind area Datum measurement: Screw thread bottom or the sealing surface of the flange. Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below). The characteristics of 26G radar level meter: Small antenna size, easy to install; Non-contact radar, no wear, no pollution. Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes. Serious dust environment on the high level meter work has little effect. A shorter wavelength, the reflection of solid surface inclination is better. Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference. The measuring range is smaller, for a measurement will yield good results. High signal-to-noise ratio, the level fluctuation state can obtain better 1 www.flowmeter.cc

performance. High frequency, measurement of solid and low dielectric constant of the best choice. 2. Product Introduction KRD521 KRD522 KRD523 Application: All kinds of corrosive liquid Measuring Range:10 meters Process Connection: Thread, Flange Medium Temperature: -40 ~ 130 Process Pressure: -0.1~0.3 MPa Accuracy: ± 5mm Protection Grade: IP67 Frequency Range: 26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus Explosion-proof Grade: Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb Application:Liquid Measuring Range:30 meters Process Connection:Thread, Flange Medium Temperature:-40 ~ 250 Process Pressure:-0.1 ~ 4.0 MPa Accuracy: ± 3mm Protection Grade:IP67 Frequency Range: 26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus Explosion-proof Grade: Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb Application:Solid material, Strong dust easy to crystallize, condensation occasion Measuring Range: 70 meters Process Connection:Universal Flange Medium Temperature: -40 ~ 250 Process Pressure: -0.1 ~ 0.1 MPa Protection Grade: IP67 Accuracy: ± 15mm Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus 2 www.flowmeter.cc

Explosion-proof Grade:Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb KRD524 KRD525 KRD526 Application:Solid material, Strong dust, easy to crystallize, condensation occasion Measuring Range:80 meters Process Connection:Universal Flange Medium Temperature: -40 ~ 250 Process Pressure:-0.1 ~ 0.1MPa Accuracy: ± 15mm Protection Grade:IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus Explosion-proof Grade:Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb Application:Solid particles, Powder Measuring Range:30 meters Process Connection:Thread, Flange Medium Temperature:-40 ~ 250 Process Pressure:-0.1 ~ 4.0MPa (Flat flange) -0.1 ~ 0.1MPa (Universal Flange) Accuracy:± 10mm Protection Grade:IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus Explosion-proof Grade:Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb Application:Hygienic liquid storage, Corrosive container Measuring Range:20 meters Process Connection:Flange Medium Temperature:-40 ~ 150 Process Pressure:-0.1 ~ 0.1MPa Accuracy:± 3mm Protection Grade:IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus Explosion-proof Grade:Exia ⅡC T6 Ga Exd ia ⅡC T6 Gb 3 www.flowmeter.cc

3. The Installation Requirements Installation guide: The minimum distance 200mm Be installed in the diameter of the 1/4 or 1/6. Note: The minimum distance from the tank wall should be 200mm. Note: 1 datum 2The container center or axis of symmetry The top conical tank level, can be installed at the top of the tank is intermediate, can guarantee the measurement to the conical bottom. A feed antenna to the vertical alignment surface. If the surface is rough, stack angle must be used to adjust the angle of cardan flange of the antenna to the alignment surface. 1/4 diameter (Due to the solid surface tilt will cause the echo attenuation, even Loss of signal.) Typical installation errors: Conical tank cannot be installed above the feed port. Note: outdoor installation should adopt sunshade. 1 Correct 2 Error rainproof measures 4 www.flowmeter.cc

The instrument cannot be installed in the arched or domed roof intermediate. In addition to produce indirect echo is also affected by the echoes. Multiple echo can be larger than the real value of signal echo, because through the top can concentrate multiple echo. So cannot be installed in a central location. 1 Correct 2 Error There are obstacles affecting measurement needed reflection plate. 1 Correct 2 Error Height of nozzle: Antenna extends into the tank at least 10mm distance. 5 www.flowmeter.cc

4. The Electrical Connection The power supply voltage: (4~20)mA/HART (Two wire system) The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument. (4~20)mA/HART(Four wire system) Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data. RS485 / Modbus Power supply and Modbus signal line separate drespectively using a two-core shielded cable, the power supply voltage range see technical data. Connection mode: 24V two wire wiring diagram as follows: 220V four wire connection is as below: 6 www.flowmeter.cc

24V RS485/Modbus wiring diagram as follows: Safety instructions: Please observe the local electrical code requirements! Please comply with local requirements for personnel health and safety regulations. All electrical components of instrument operation must be completed by the formal training of professionals. Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements. Protection grade: This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram: : 7 www.flowmeter.cc

How to install to meet the requirements of IP67: Please make sure that the sealing head is not damaged. Please make sure that the cable is not damaged. Please make sure that the cable for use with electrical connection specification. Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the1 Tighten the cable seal head, see the2 Please electrical interface will not use blind plug tight, see the3 5. Instrument Commissioning There are three kinds of debugging method: 1) Display / Keyboard 2) Host debugging 3) HART handheld programmer Display / Keyboard: Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly. Display / Keyboard 1 Liquid crystal display(lcd) 2 The key 8 www.flowmeter.cc

PC debugging: Connected to PC by HART 24 VDC Power Supply 1 RS232 interface or USB interface 2 Radar level meter 3 HART adapter 4 250 Ω resistor HART handheld programmer: 1 HART handheld programmer 2 Radar level meter 3 250 Ωresistor 24 VDC Power Supply 6. Structure Size (Unit: mm) The outer shell: 9 www.flowmeter.cc

Appearance size: KRD521 KRD522 KRD523 10 www.flowmeter.cc

KRD524 KRD525 KRD526 11 www.flowmeter.cc

Flange type: 7. Technical Parameters The outer shell The seal between the shell and the shell cover Casing window The ground terminal Silicone rubber Polycarbonate Stainless steel The power supply voltage Two wire system The standard type (16 ~ 26) V DC Intrinsically safe (21.6 ~ 26.4) V DC Power dissipation max 22.5mA / 1W Allowable ripple - <100Hz Uss<lV - (100~100K) Hz Uss<l0mV The cable parameters Cable entrance / plug Terminal Output parameters The output signal Communication protocol Resolution Fault signal The integral time 1 M20xl.5 cable entrance 1 blind plug Conductor cross section 2.5mm² (4 ~ 20) ma/rs485 HART 1.6μA Constant current output; 20. 5mA 22mA 3.9mA (0 ~ 50) s, adjustable 12 www.flowmeter.cc

Blind area the ends of the antenna The maximum distance measurement 80 meters Microwave frequency 26GHz Communication interface HART communication protocol The measurement interval about 1 second (depending on the parameter settings) Adjust the time Display resolution about 1 second (depending on the parameter settings) 1 mm Working storage and transportation temperature (-40~100) Process temperature (the temperature of the antenna part) KRD521 (-40~130) KRD522/KRD523/KRD524/KRD525 (-40~250) KRD526 (-40~150) Pressure Seismic Max.4MPa Mechanical vibration l0m/s², (10 ~ 150) Hz 8. Meter Linearity KRD521 Emission angle 20 Precision See chart 13 www.flowmeter.cc

KRD522 Emission angle Depending on the size of the antenna - 46mm 18-76mm 12-96mm 8-121mm 6 Precision See chart KRD523 Emission angle Depending on the size of the antenna - 46mm 182-76mm 12-96mm 8-121mm 6 Precision See chart KRD524 Emission angle Depending on the size of the antenna - 196mm 4-242mm 4 Precision See chart 14 www.flowmeter.cc

KRD525 Emission angle Depending on the size of the antenna - 76mm 12-96mm 8-121mm 6 Precision See chart KRD526 Emission angle Depending on the size of the antenna - 46mm 18-76mm 12-96mm 8 Precision See chart 15 www.flowmeter.cc

9. Product Model Selection KRD521 License P Standard (Non-explosion-proof) I Intrinsically safe (Exia IIC T6 Ga) G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Antenna Type / Material / Temperature F Sealing horn / PTEE / -40... 130 Process Connection / Material G Thread G1½ A N Thread 1½ NPT A Flange DN50 /PP B Flange DN80 /PP C Flange DN100 /PP Y Special custom The Outlet Pipe Length of the Container A Outlet pipe 100mm B Special custom The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic / IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A Belt X Without 16 www.flowmeter.cc

KRD522 License P Standard (Non-explosion-proof) I Intrinsically safe (Exia IIC T6 Ga) G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Process Connection / Material G Thread G1½ A / Stainless Steel 304 N Thread 1½ NPT / Stainless Steel 304 A Flange DN50 / Stainless Steel 304 B Flange DN80 / Stainless Steel 304 C Flange DN100 / Stainless Steel 304 Y Special Custom Antenna Type / Material A Horn Antenna Φ46mm / Stainless Steel 316L B Horn Antenna Φ76mm / Stainless Steel 316L C Horn Antenna Φ96mm / Stainless Steel 316L Y Special Custom Seal Up / Process Temperature V Viton / (-40~150) K Kalrez / (-40~250) The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic/ IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A Belt X Without 17 www.flowmeter.cc

KRD523 License P Standard (Non-explosion-proof) I Intrinsically safe (Exia IIC T6 Ga) G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Process Connection / Material G Thread G1½ A / Stainless Steel 304 N Thread 1½ NPT / Stainless Steel 304 B Flange DN80 / Stainless Steel 304 C Flange DN100 / Stainless Steel 304 D Flange DN125 / Stainless Steel 304 E Flange DN150 / Stainless Steel 304 F Flange DN200 / Stainless Steel 304 H Flange DN250 / Stainless Steel 304 M Flange DN80 / Cardan joint K Flange DN100 / Cardan joint T Flange DN125 / Cardan joint Z Flange DN150 / Cardan joint W Flange DN200 / Cardan joint V Flange DN250 / Cardan joint Y Special Custom Antenna Type / Material B Horn Antenna Φ76mm / Stainless Steel 316L C Horn Antenna Φ96mm / Stainless Steel 316L D Horn Antenna Φ121mm / Stainless Steel 316L Seal Up / Process Temperature V Viton / (-40~150) K Kalrez / (-40~250) The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic/ IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A Belt X Without 18 www.flowmeter.cc

KRD524 License P Standard (Non-explosion-proof) I Intrinsically safe (Exia IIC T6 Ga) G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Process Connection / Material G Thread G1½ A / Stainless Steel 304 N Thread 1½ NPT / Stainless Steel 304 B Flange DN80 / Stainless Steel 304 C Flange DN100 / Stainless Steel 304 D Flange DN125 / Stainless Steel 304 E Flange DN150 / Stainless Steel 304 F Flange DN200 / Stainless Steel 304 H Flange DN250 / Stainless Steel 304 M Flange DN80 / Cardan joint K Flange DN100 / Cardan joint T Flange DN125 / Cardan joint Z Flange DN150 / Cardan joint W Flange DN200 / Cardan joint V Flange DN250 / Cardan joint Y Special Custom Antenna Type / Material B Horn Antenna Φ196mm / Stainless Steel 316L C Horn Antenna Φ242mm / Stainless Steel 316L Seal Up / Process Temperature V Viton / (-40~150) K Kalrez / (-40~250) The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic/ IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A Belt X Without 19 www.flowmeter.cc

KRD525 License P Standard (Non-explosion-proof) I Intrinsically safe (Exia IIC T6 Ga) G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Process Connection / Material G Thread G1½ A / Stainless Steel 304 N Thread 1½ NPT / Stainless Steel 304 B Flange DN80 / Stainless Steel 304 C Flange DN100 / Stainless Steel 304 D Flange DN125 / Stainless Steel 304 E Flange DN150 / Stainless Steel 304 F Flange DN200 / Stainless Steel 304 H Flange DN250 / Stainless Steel 304 M Flange DN80 / Cardan joint K Flange DN100 / Cardan joint T Flange DN125 / Cardan joint Z Flange DN150 / Cardan joint W Flange DN200 / Cardan joint V Flange DN250 / Cardan joint Y Special Custom Antenna Type / Material B Horn Antenna Φ76mm / Stainless Steel 316L C Horn Antenna Φ96mm / Stainless Steel 316L D Horn Antenna Φ121mm / Stainless Steel 316L Seal Up / Process Temperature V Viton / (-40~150) K Kalrez / (-40~250) The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic/ IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A Belt X Without 20 www.flowmeter.cc

KRD526 License P I G Standard (Non-explosion-proof) Intrinsically safe (Exia IIC T6 Ga) Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb) Process Connection / Material B Flange DN80 / Stainless Steel 304 C Flange DN100 / Stainless Steel 304 E Flange DN150 / Stainless Steel 304 Y Special Custom Antenna Type / Material B C D Horn Antenna Φ46mm / Stainless Steel 316L Horn Antenna Φ76mm / Stainless Steel 316L Horn Antenna Φ96mm / Stainless Steel 316L Seal Up / Process Temperature V Viton / (-40~150) The Electronic Unit 2 (4~20) ma / 24V DC / Two wire system 3 (4~20) ma / 24V DC / HART two wire system 4 (4~20) ma / 220V AC / Four wire system 5 RS485 / Modbus Shell / Protection Grade L Aluminum / IP67 G Plastic/ IP65 Cable Line M M 20x1.5 N ½ NPT Field Display/The Programmer A X Belt Without 21 www.flowmeter.cc

Material level meter selection parameter table: Customer information Company: Contact: Address: Zip code: The Telephone: Fax: Mobile phone: E-mail: Date: License The standard type (Non-explosion-proof) Intrinsically safe (Exia IIB T5) Intrinsically safe (Exia IIC T6 Ga) Intrinsically safe+marine license (Exia IIC T6 Ga) Intrinsically safe and Flame proof (Exd ia IIC T6 Gb) Tank / Container Information The Types of Tank: Tank Reaction Tank Separation Tank Marine Tank The Tank Structure: Material of Tank: Pressure: Tank size: Tank Height: m Diameter: The top of the tank: Vault Flat Open Cone type The bottom of the tank: Cone bottom Flat Slope bottom Arc bottom Installation: Top installation Side installation The bypass pipe mount Guided wave pipe installation Installation takes over the top of the tank (information): Height of take over : mm Diameter of take over :: mm Measurement of Medium Media name: Lliquid Solid Mixed Media Medium temperature: Dielectric Constant: Linked material: Yes No Mixing: Yes No Process Connection Thread: G1½ A 1½ NPT Flange Flange (DN= ) Flange (ANSI= ) Power supply: 24V DC Two wire system 24V DC Four wire system 220V AC Four wire system Output: 4-20mA HART Display: Take the meter display program Without meter display program 22 www.flowmeter.cc