Time Comparisons by GPS C/A, GPS P3, GPS L3 and TWSTFT at KRISS

Similar documents
Improvement GPS Time Link in Asia with All in View

LONG-BASELINE TWSTFT BETWEEN ASIA AND EUROPE

THE FIRST TWO-WAY TIME TRANSFER LINK BETWEEN ASIA AND EUROPE

STABILITY OF GEODETIC GPS TIME LINKS AND THEIR COMPARISON TO TWO-WAY TIME TRANSFER

ESTIMATING THE RECEIVER DELAY FOR IONOSPHERE-FREE CODE (P3) GPS TIME TRANSFER

Recent Calibrations of UTC(NIST) - UTC(USNO)

INITIAL TESTING OF A NEW GPS RECEIVER, THE POLARX2, FOR TIME AND FREQUENCY TRANSFER USING DUAL- FREQUENCY CODES AND CARRIER PHASES

STABILITY OF GEODETIC GPS TIME LINKS AND THEIR COMPARISON TO TWO-WAY TIME TRANSFER

STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE

Time and Frequency Activities at NICT, Japan

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.

THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY

MULTI-GNSS TIME TRANSFER

TWSTFT NETWORK STATUS IN THE PACIFIC RIM REGION AND DEVELOPMENT OF A NEW TIME TRANSFER MODEM FOR TWSTFT

BUREAU INTERNATIONAL DES POIDS ET MESURES

GPS Carrier-Phase Time Transfer Boundary Discontinuity Investigation

THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD.

Timing-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach

TIME TRANSFER EXPERIMENT BY TCE ON THE ETS-VIII SATELLITE

A COMPAROTIVE STUDY OF GPS P3 AND GPS L3

THE TIME LINK BETWEEN CSAO AND CRL

Certificate of Calibration No

TIME AND FREQUENCY TRANSFER COMBINING GLONASS AND GPS DATA

USE OF GEODETIC RECEIVERS FOR TAI

ABSOLUTE CALIBRATION OF TIME RECEIVERS WITH DLR'S GPS/GALILEO HW SIMULATOR

UNCERTAINTIES OF TIME LINKS USED FOR TAI

Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina

Evaluation of timing GPS receivers for industrial applications

A Comparison of GPS Common-View Time Transfer to All-in-View *

Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias

TWO-WAY TIME TRANSFER WITH DUAL PSEUDO-RANDOM NOISE CODES

A CALIBRATION OF GPS EQUIPMENT IN JAPAN*

Federal Department of Justice and Police FDJP Federal Office of Metrology METAS. Measurement Report No

Pilot study on the validation of the Software- Defined Radio Receiver for TWSTFT

GOTOH Tadahiro, KANEKO Akihiro, SHIBUYA Yasuhisa, and IMAE Michito

2-2 Summary and Improvement of Japan Standard Time Generation System

Time and Frequency Activities at KRISS

Time and frequency transfer methods based on GNSS. LIANG Kun, National Institute of Metrology(NIM), China

The Timing Group Delay (TGD) Correction and GPS Timing Biases

PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES

CCTF 2012: Report of the Royal Observatory of Belgium

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)

Recent Time and Frequency Transfer Activities at the Observatoire de Paris

RESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES

Clock Synchronization of Pseudolite Using Time Transfer Technique Based on GPS Code Measurement

GPS WEEK ROLL-OVER AND Y2K COMPLIANCE FOR NBS-TYPE RECEIVERS, AND ABSOLUTE CALIBRATION OF THE NIST PRIMARY RECEIVER"

UNCERTAINTIES OF TIME LINKS USED FOR TAI

ATOMIC TIME SCALES FOR THE 21ST CENTURY

BIPM TIME ACTIVITIES UPDATE

BUREAU INTERNATIONAL DES POIDS ET MESURES

5-3 JJY, The National Standard on Time and Frequency in Japan

TIME TRANSFER BETWEEN USNO AND PTB: OPERATION AND CALIBRATION RESULTS

Report of the CCTF WG on TWSTFT. Dirk Piester

Time and Frequency Activities at NICT, Japan

CALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT

The Multi-Mode Time Transfer Based on GNSS

SIMULTANEOUS ABSOLUTE CALIBRATION OF THREE GEODETIC-QUALITY TIMING RECEIVERS

Report of Time and Frequency Activities at NICT

RECENT TIME AND FREQUENCY ACTIVITIES AT PTB

Comparison of Cesium Fountain Clocks in Europe and Asia

Precise Common-View Time and Frequency Transfer (PCVTFT) based on BDS GEO Satellite

CCTF 2015: Report of the Royal Observatory of Belgium

National time scale UTC(SU) and GLONASS system time scale: current status and perspectives

THE STABILITY OF GPS CARRIER-PHASE RECEIVERS

Relative Calibration of the Time Transfer Link between CERN and LNGS for Precise Neutrino Time of Flight Measurements

Experimental Assessment of the Time Transfer Capability of Precise Point Positioning (PPP)

LONG-BASELINE COMPARISONS OF THE BRAZILIAN NATIONAL TIME SCALE TO UTC (NIST) USING NEAR REAL-TIME AND POSTPROCESSED SOLUTIONS

Update of research activities on time and frequency at the National Institute of Information and Communications Technology (NICT)

LIMITS ON GPS CARRIER-PHASE TIME TRANSFER *

RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND

Activity report from NICT

CALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT

BUREAU INTERNATIONAL DES POIDS ET MESURES

COMPARISON OF LASSO AND GPS TIME TRANSFERS

A NEW APPROACH TO COMMON-VIEW TIME TRANSFER USING ALL-IN-VIEW MULTI-CHANNEL GPS AND GLONASS OBSERVATIONS

On Optimizing the Configuration of Time-Transfer Links Used to Generate TAI ABSTRACT I. INTRODUCTION

CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI)

Impact of multi-gnss on international timekeeping

REPORT ON THE 8TH MEETING OF THE CCTF WORKING GROUP ON TWO-WAY SATELLITE TIME AND FREQUENCY TRANSFER

Report of the GPS calibration trip among NIMT, NMIM, and VMI in 2017

Two-Way Time Transfer via Satellites and Optical Fibers. Physikalisch-Technische Bundesanstalt

Expert Site Visit Report

Calibration schedule 2016/9/29

Activity report from NICT

CCTF WG on GNSS time transfer

NMI's Role and Expertise in Synchronization Applications

5-2 Generating and Measurement System for Japan Standard Time

GALILEO COMMON VIEW: FORMAT, PROCESSING, AND TESTS WITH GIOVE

GPS WEEK ROLL-OVER AND Y2K COMPLIANCE FOR NBS-TYPE RECEIVERS, AND ABSOLUTE CALIBRATION OF THE NIST PRIMARY RECEIVER"

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY

METAS TIME & FREQUENCY METROLOGY REPORT

AOS STUDIES ON USE OF PPP TECHNIQUE FOR TIME TRANSFER

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

STUDIES ON INSTABILITIES IN LONG-BASELINE TWO-WAY SATELLITE TIME AND FREQUENCY TRANSFER (TWSTFT) INCLUDING A TROPOSPHERE DELAY MODEL

Technology of Precise Orbit Determination

PROGRESS REPORT OF CNES ACTIVITIES REGARDING THE ABSOLUTE CALIBRATION METHOD

STATISTICAL CONSTRAINTS ON STATION CLOCK PARAMETERS IN THE NRCAN PPP ESTIMATION PROCESS

First Evaluation of a Rapid Time Transfer within the IGS Global Real-Time Network

OPTICAL LINK TIME TRANSFER BETWEEN IPE AND BEV

A New Algorithm to Eliminate GPS Carrier-Phase Time Transfer Boundary Discontinuity.pdf

Transcription:

Time Comparisons by GPS C/A, GPS, GPS L3 and at KRISS Sung Hoon Yang, Chang Bok Lee, Young Kyu Lee Division of Optical Metrology Korea Research Institute of Standards and Science Daejeon, Republic of Korea shyang@kriss.re.kr Abstract We present an overview of time transfer activities at Korea Research Institute of Standards and Science (KRISS). During the last few years, we have equipped the geodetic receivers for P code and carrier phase measurements, and built two-way satellite time and frequency transfer () system to improve the time comparison accuracy. Now, we are conducting the time comparisons between KRISS and National Institute of Information and Communications (NICT, Japan) including several institutes in Asia using various GPS time transfer methods such as GPS C/A code, code, carrier phase, and techniques. The equipment for time transfers are TTR6, 3S-R100, Euro-80, and a geodetic receiver (Z12-T) for GPS link, and multi-channel via JCSAT- 1B satellite for two-way link. From the all data, we have compared and evaluated the differences between the various comparison methods by GPS versus TWTSTF. Ji Ae Han, Yun Jeon Heo Chungbuk National University Cheongju, Republic of Korea geodetic receivers. Moreover recently we have constructed links as shown in Fig. 1. We present the comparison results between UTC(KRIS) and UTC(NICT) by using the several types of time transfer methods mentioned before: multi-channel GPS C/A code, GPS code, GPS L3 and. Besides s are compared with GPS code between UTC(KRIS) and UTC(NMIJ), UTC(NTSC), UTC(TL) based on Circular T. The intention of this paper is to introduce KRISS time transfer activities and to present how well we can compare time difference between KRISS and other institutes in Asia using GPS satellites and links at the present. I. INTRODUCTION In 1981, the first GPS common-view time transfers using single-channel C/A code were introduced [1]. BIPM has been using clock data via GPS since 1983 for establishing the International Atomic Time (TAI). And UTC scale is realized by using the combination of TAI. For the purpose of this, timing laboratories are using navigation satellites and/or geostationary satellites, that is, GPS, GLONASS and communication satellites. Especially, GPS has offered many effective ways to national standard institutes for time comparisons between clocks over the last two decades. But the first common-view method so-called single-channel GPS C/A code common-view time transfer is insufficient for the present-day clock comparison. Accordingly more accurate time transfer method becomes to be essential. The needs of the current of the times have developed the methods of multi-channel GPS C/A code [2], GPS code, GPS carrier phase [3] and [4]. KRISS has begun to report the time transfer data by GPS in the place of LORAN-C to BIPM since 1987. Up to the present we have equipped and maintained various time transfer receivers: AOA TTR6 receivers, a 3S Navigation R100-40T GPS/GLONASS receiver and Ashtech Z12-T II. Figure 1. links at KRISS. TIME TRANSFER APPARATUS AT KRISS A. TTR6 The NBS-type single channel GPS C/A code common view receiver is well known to timing laboratories. We have maintained three TTR6 receivers and these are operating for 0-7803-9052-0/05/$20.00 2005 IEEE. 716

the redundant transfer system and domestic time synchronization experiments [5]. B. R100-40T An R100-40T receiver purchased in 1999 can provide highly accurate time transfer capabilities with temperature stabilized antenna. Besides, it combines measurements of GLONASS as well as GPS satellites. But unfortunately it had worked abnormally after being built. Recently this receiver has been working well owing to the upgrade of software and hardware. However the comparison by this receiver is not evaluated in this paper. C. Euro-80 We have operated a Topcon Euro-80 receiver introduced in 2002, which is developed by NMIA in Australia for the purpose of GPS dual frequency L1/L2 common view time transfer system. So we can get the measured ionosphere delay with modeled results. At present this receiver has been operating as main time transfer equipment at KRISS. We present the time difference between KRISS and NICT by multi-channel C/A code using these receivers in this paper. D. Z12-T Ashtech Z12-T GPS receiver provides highly accurate time transfer through P-code and carrier phase comparison. GPS P-code signal has two main advantages for precise time transfer: (1) GPS P code pseudo-range measurements are more precise than GPS C/A code measurements because of one tenth of chip-length, compared to GPS C/A code; (2) it is possible to measure the ionospheric delays owing to receiving both L1 and L2 frequencies at the same time. In addition, this one offers the capability of conducting the carrier phase measurement of which accuracy is at the level of sub nanosecond [6]. Two Z12-T receivers have been equipped and the comparison results by code will contribute to time scale. Now one of these is participating in calibration trip by BIPM and we will report regularly the comparison results to BIPM as a master link in this year. E. earth stations at KRISS have been established since 2002. At present we have constructed two stations, one has linked to Asia region via JCAST-1B satellite and the other has linked to Oceania region via PAS-8 satellite. Besides one more system will be introduced for Europe link in this year. All of s were developed by NICT and have multi-channel function, therefore we are able to compare simultaneously with several institutes [7]. KRISS, NICT, NMIJ, NTSC, TL and SPRING are participating in these comparisons via JCSAT-1B using this. Unfortunately during April, we did not have the comparison data of SPRING because of the system failure at that time. In addition to JCSAT-1B, KRISS has the link to NMIA and NICT via PAS-8 satellite. NICT calculated and reported the calibration results of Asia-Pacific two-way link using GPS all-in-view, GPS common view and/or previous link using Atlantis [8]. We compensated these calibration results for this computation and could verify that they were in consistency with Circular T and calibrated GPS comparison. III. TIME COMPARISON RESULTS For measuring the time difference between KRISS and NICT, we used the GPS receivers (TTR6, Euro-80, Z12-T) and for the period of three months. Fig. 2 to Fig. 4 show the time comparison results by various time transfer equipment from April to June 2005. They are coincident well with each other, so the curves are shifted up from Circular-T by 20 ns each for better visibility. The data from TTR6 and Euro-80 receivers are gathered up to 48 each day by BIPM schedule. By the observation schedule, we computed the difference between UTC(KRIS) and UTC(NICT) from [UTC(KRIS) - GPS time] and [UTC(NICT) - GPS time]. But we did not compensate the delays and offsets by Z12-T receiver because it was not calibrated yet. So we drew the inartificial results, and only code data were shifted against L3 by 20 ns for visibility. In order to compare the quality, all the stabilities are computed by transfer methods during the same period for about 4 days (MJD 53475 to 53478). The selected evaluation date was chosen by the period of the consecutive measured time of both and GPS comparison results. Here we calculated the stabilities using one-second sampled two-way data, 16-minute sampled code data and 30-second sampled carrier phase data obtained from RINEX file. As shown in Fig. 4, we observe a significant improvement in frequency stability of the carrier phase and the measurement for consecutive period for averaging time. Table I shows the rms values in average for the measurement period. Figure 2. Time differences between UTC(KRIS) and UTC(NICT) computed by L3,,, M/C CV, S/C CV and Circular T in order. Curves were intentionally shifted by 20 ns each for visibility. L3 and data were not compensated with calibration offset values. 717

TABLE I. UTC(NICT) BY EACH METHOD Transfer method Rms in ns Equipment GPS Single channel C/A-code 11.5 TTR6 GPS Multi-channel C/A-code 5.7 Euro-80 GPS P-code 2.7 Z12-T GPS carrier phase 2.6 Z12-T 2.8 Figure 3. Time differences between UTC(KRIS) and UTC(NICT) computed by L3,,, M/C CV, S/C CV and Circular T in order. Curves were intentionally shifted by 20 ns each for visibility. L3 and data were not compensated with calibration offset values. (May 2005). We compared the time differences between UTC(KRIS) and UTC(NMIJ) by GPS -code and during April 2005. The comparison results are shown in Fig. 6. In this figure, the code data moved towards the time difference of and Circular T in order to compare each other easily. As shown in Fig. 7, then we calculated the stabilities during the period from MJD 53461 to 53467 (denoted tm in Fig. 6) and presented their rms values in Table II. Figure 4. Time differences between UTC(KRIS) and UTC(NICT) computed by L3,,, M/C CV, S/C CV and Circular T in order. Curves were intentionally shifted by 20 ns each for visibility. L3 and data were not compensated with calibration offset values. (June 2005). Figure 6. Time differences between UTC(KRIS) and UTC(NMIJ) computed by, and Circular T. The code data were not UTC(KRIS)-UTC(NICT) UTC(KRIS)-UTC(NMIJ) TTR6 E-80 L3 Averaging Time, Seconds Averaging Time, Seconds Figure 5. Stabilities between UTC(KIRS) and UTC(NICT) by time transfer methods. Figure 7. Stabilities between UTC(KIRS) and UTC(NMIJ) by code and. 718

TABLE II. UTC(NMIJ) BY EACH METHOD TABLE III. UTC(NTSC) BY EACH METHOD. GPS P-code 1.4 Z12-T 1.0 GPS P-code 1.6 Z12-T 1.6 We also show the measured differences between UTC(KRIS) and UTC(NTSC) for a month in Fig. 8, and calculate the stabilities by GPS code and for the period from MJD 53461 to 53467 (denoted tm in Fig. 8) in Fig. 9. We also shift the code data for better visibility. Figure 10. Time differences between UTC(KRIS) and UTC(TL) computed by, and Circular T. The code data were not Figure 8. Time differences between UTC(KRIS) and UTC(NTSC) computed by, and Circular T. The code data were not Figure 9. UTC(KRIS)-UTC(NTSC) Averaging Time, Seconds Stabilities between UTC(KIRS) and UTC(NMIJ) by code and. For comparing UTC(KRIS) with UTC(TL), we calculated the time differences during the period from MJD 53472 to 53481 (denoted tm in Fig. 10) and Fig. 11 represents the stabilities of each time transfer method. Figure 11. TABLE IV. UTC(KRIS)-UTC(TL) Averaging Time, Seconds Stabilities between UTC(KIRS) and UTC(TL) by code and. UTC(TL) BY EACH METHOD. GPS P-code 2.5 Z12-T 2.3 719

IV. CONCLUSIONS We presented the activities of KRISS time transfer and the comparison results of time differences between several institutes in Asia using various types of methods. The stability of time transfer is improved when GPS common-view time transfer is carried out in code measurement. Furthermore, we observed a significant improvement in frequency stability, using GPS carrier phase and. Here for carrier phase measurement between KRISS and NICT, we used the self-developed software to process the RINEX file from a Z12-T geodetic receiver [9]. We have performed the manifold time transfer applications to improve the accuracy. At present, we are participating in the Z12-T receiver calibration trip performed by BIPM. Therefore, after compensating the offset value from the calibration result, we will generate the more accurate time transfer data. In the near future, the comparison results by GPS code and link will be reported officially with multi-channel GPS C/A code data. Furthermore, we expect that GPS carrier phase measurement and link to Europe (we plan to link to PTB with NICT via PAS-4 satellite) will contribute to the better TAI computation. ACKNOWLEDGMENT The authors would like to thank the colleagues of NICT for cooperation. REFERENCES [1] Allan D.W., Weiss M.A. (1980), Accurate time and frequency transfer during common-view of a GPS satellite, Proc. 1980 Frequency Control Symposium, pp. 334-336 [2] J. Levine, Time transfer using multi-channel GPS receiver, IEEE Trans. UFFC, 46(2), pp 392-398, 1999. [3] G. Petit, P. Moussay, and C. Thomas, GPS tiem transfer using carrier-phase and P-code measurements, in Proc. 10 th EFTF, 1966, pp. 279-285. [4] Kirchner D, Two-way time transfer via communication satellites, Proc. IEEE 79, 1991, pp.983-990. [5] Y. B. Kim, S. H. Yang, C. B. Lee, Remote measurement and verification for the network synchronization by GPS commonview technique, Proc. Asia-Pacific Workshop on Time and Frequency, 2002, pp. 264-268. [6] G. Petit, C. Thomas, Z. Jiang, P. Uhrich, and F. Taris, Use of GPS Ashtech Z12T receivers for accurate tiem and frequency comparisons, IEEE Transactions on Ulrasonics, Ferrorlectronics, and Frequency Control, 1999, 46(4), pp.941-949. [7] M. Imae, T. Gotoh, T.Suzuyama, Y. Shibuya, F. Nakagawa, R. Tabuchi, Time transfer for developed by CRL, Proc. Asia-Pacific Workshop on Time and Frequency, 2002, pp. 210-217. [8] NICT, Calibration results of Asia-Pacific two-way link with NICT s, 2005. unpublished. [9] Y. J. Heo, C. B. Lee, S. H. Yang, and Y. K. Lee, Time transfer technique by KRISS software using GPS carrier phase, Proc. Asia-Pacific Workshop on Time and Frequency, 2004, pp. 285-290. 720