Introduction. Controls and Locations

Similar documents
MFJ-834 RF Ammeter. Introduction. Uses

MFJ-835 RF Ammeter. Introduction. Uses

MFJ-836H SWR/Wattmeter and RF Ammeter

1997 MFJ ENTERPRISES, INC.

ALWAYS ATTACH THE SAFETY ROPE TO A STABLE SUPPORT BEFORE ATTEMPTING TO ATTACH THE UNIVERSAL MOUNT TO A WINDOW FRAME OR RAIL.

MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS

Introduction LOADING COIL COUNTERPOISE ATTACHMENT ANTENNA ATTACHMENT. Figure 1: MFJ-1625 Window/Balcony Mount Antenna

MFJ-969 Versa Tuner II Instruction Manual

MFJ-249B HF/VHF SWR ANALYZER

Introduction. Understanding Power Ratings. Peak Reading SWR/Wattmeter

Instruction Manual. Model USB Wattmeter

Transmission lines. Characteristics Applications Connectors

MFJ-949E. tuner antenowy skrzynka antenowa. Instrukcja obsługi. importer:

MFJ-203 Bandswitched Dip Meter

MFJ-941E Versa Tuner II GENERAL INFORMATION:

Practical Tricks with Transformers. Larry Weinstein K0NA

Vectronics VC-300D DIGITAL BARGRAPH ANTENNA TUNER

MFJ ENTERPRISES, INC.

Clip-on RF Current Meter

MFJ Balanced Line Tuner

Definitions of Technical Terms

VECTRONICS HFT-1500 Digital Bargraph Antenna Tuner

Technician Licensing Class. Lesson 4. presented by the Arlington Radio Public Service Club Arlington County, Virginia

2006 MFJ ENTERPRISES, INC.

MFJ ENTERPRISES 300 INDUSTRIAL PARK STARKVILLE, MS USA

VECTRONICS. VC-300DLP Antenna Tuner

BTM Series Pulsed RF Power Amplifier Modules. Application Note

2006 MFJ ENTERPRISES, INC.

2013 MFJ ENTERPRISES, INC.

Model Directional RF Wattmeter

IntelliTuner Automatic Antenna Tuners

VC-300D VECTRONICS R. Digital Bar Graph Antenna Tuner. Owner's Manual. CAUTION: Read All Instructions Before Operating Equipment!

WA3RNC 30 METER CRYSTALPLEXER TRANSMITTER KIT ASSEMBLY INSTRUCTIONS

2014 MFJ ENTERPRISES, INC.

2006 MFJ ENTERPRISES, INC.

2005 MFJ ENTERPRISES, INC.

MFJ 259 Operation & Simplified Calibration

MFJ-2982 Feather-Lite 80-6 Meter Vertical Antenna

MFJ-2389 Compact 8 Band Vertical

Ameritron RCS-10 INTRODUCTION

Exercise MM About the Multimeter

2006 MFJ ENTERPRISES, INC.

Current Probes. User Manual

SUBELEMENT T5 Electrical principles: math for electronics; electronic principles; Ohm s Law 4 Exam Questions - 4 Groups

INSTALLATION MANUAL. CTA-30RK-550 Rack Mount Distribution Amplifier

RF Power Meter. where V is the peak power across the load, R is the resistance of the load and P is the r.m.s. power.

Mirage B-320-G FEATURES

User Guide for the Alpha Loop Jr+ Antenna

1. What is the unit of electromotive force? (a) volt (b) ampere (c) watt (d) ohm. 2. The resonant frequency of a tuned (LRC) circuit is given by

731A seismic accelerometer and P31 power unit/amplifier Operating guide

Microphone audio, from the MFJ-1278B to your transmitter. Ground, audio and PTT common. Push-to-talk, to allow the MFJ-1278B to key your transmitter.

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

TZ-RD-1740 Rotary Dipole Instruction Manual

Connecting The EasySense unit will detect that the Current Sensor is connected.

Lesson 11: Antennas. Copyright Winters Version 1.0. Preparation for Amateur Radio Technician Class Exam

Central Electronics Model 600L Linear Amplifier

MFJ-904. tuner antenowy skrzynka antenowa. Instrukcja obsługi. importer:

ALWAYS ATTACH THE SAFETY ROPE TO A STABLE SUPPORT BEFORE ATTEMPTING TO ATTACH THE UNIVERSAL MOUNT TO A WINDOW FRAME OR RAIL.

Technician License. Course

2012 MFJ ENTERPRISES, INC.

Technician Licensing Class T5

MASTR II BASE STATION MHz RECEIVER IF/AUDIO/SQUELCH & RF ASSEMBLY (25 khz/12.5 khz CHANNEL SPACING) Maintenance Manual LBI-38506A

RBS RADIO BATTERY SWITCH CONSTRUCTION MANUAL. RBS Construction Manual Issue 1 Page 1

P R O T R O N I X D i g i t a l P o w e r M e t e r M o d e l : A I n s t r u c t i o n M a n u a l

ARNSW Balun Day. Balun construction

Technician Licensing Class. Antennas

2013 MFJ ENTERPRISES, INC.

MFJ-208 VHF SWR Analyzer

COAXIAL TRANSMISSION LINE COMMON-MODE CURRENT

Hendricks QRP Kits The Twofer Rev

Note: 1. All the students must strictly follow all the safety precautions. 2. In case of any question or concern, please contact LAB INSTRUCTOR or TA.

INSTRUCTION MANUAL. Specifications Mechanical. 1 5/8 to 2 1/16 O.D. (41mm to 52mm)

4/25/2012. Supplement T9. 2 Exam Questions, 2 Groups. Amateur Radio Technician Class T9A: T9A: T9A: T9A:

Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM

Electronic Instrument Disadvantage of moving coil meter Low input impedance High loading error for low-voltage range voltmeter

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

Calibration Procedure for the Heathkit Antenna Tuner SA-2060 and SA2060A

Least understood topics by most HAMs RF Safety Ground Antennas Matching & Feed Lines

Technician Licensing Class T9

Weatheradio Alert ( ) Features Faxback Doc. # 47648

Long Loopstick Antenna

Analog S-Meter: Responsive mechanical meter gives accurate meaningful reports.

The 21st Century R-390A/URR Reference Y2K-R3 Edited 7/09: No Technical Changes Chapter 2 - Operation. Page Table Of Contents 2-1

This file was downloaded from the website of G7SYW.

Getting started with the 2 Port Antenna Switch

MFJ-1026 MFJ Deluxe Noise Canceling Signal Enhancer Instruction Manual

MFJ ENTERPRISES, INC.

Electrical Fundamentals and Basic Components Chapters T2, T3, G4

Broadband Current Probe Series Operation Manual

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

+ 24V 3.3K - 1.5M. figure 01

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

IntelliTuner Automatic Antenna Tuner

Radio Control Installation and Operating Instructions System 4

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Manual AMERITRON QSK-5PC T/R SWITCH PC BOARD INTRODUCTION

MFJ-945E. tuner antenowy skrzynka antenowa. Instrukcja obsługi. importer:

Mirage B-310-G FEATURES

Broadband Current Probe Series Operation Manual

Transcription:

Introduction Congratulations on purchasing the MFJ-854 RF-Current Meter. The MFJ-854 is designed for measuring current distribution on antenna elements and radials, and for checking common-mode current levels on coaxial feedlines and grounds. It also works well for tracking down RFI-causing current on household wiring and cables. Here are some important features we think you'll like: Wide Range: Measures RF current from as little as 1 ma to 3 Amps in six ranges. Full HF Coverage: Accurate from 1 MHz to 30 MHz and beyond. Low Interaction: Sense coil has minimal effect on circuits under test. Large Cable Capacity: Accepts cables up to approximately 1/2" in diameter. Accurate: Diode-compensated Op-Amp delivers improved meter linearity. Rugged: Built to last with a sturdy all-aluminum case and G-10 pc board. Battery Saver: Press-to-test power circuit turns unit off automatically after 15 seconds. Long Battery Life: Meter draws 3-mA, battery's service life approaches shelf life. Handheld Size: Weighs 11 ounces, only 2.3" x 1.6" x 6.5" (including sense coil). Controls and Locations 1 2 Cable 3 100mA 300mA 30mA 1A <30mA 3A Adj Ampres 4 Sensitivity MFJ-854 Power On 5 9-V 6 1. Sense Coil: Clamps onto conductor under test, accepts diameters to around 1/2". 2. Meter: Calibrated scale indicates readings in ma or Amps. 3. Range: Selects from six measurement ranges. 4. Sensitivity: Works on <30 ma range, adjusts gain for low-level measurements. 5. Power On: Momentary switch applies power, activates 15-second power-off delay. 6. Battery Clip: Accepts any standard 9-V flat-pack battery.

Battery Installation and Replacement: Use any fresh 9-volt flat-pack type battery (not supplied). To install, remove screw from each side of case and gently separate two halves. Install 9-volt battery on snap clip, then slip into retainer (see previous drawing). To prevent damage from battery leakage, always remove battery when storing meter for prolonged periods. Important Note: Always remove the battery when storing your unit for long periods. Operating Instructions Using the Sense Coil: The sense coil snaps over wires and cables, as shown below. To unlatch, squeeze the nylon carrier between thumb and forefinger--applying opposing pressure. The coil's top section should move forward slightly. With pressure applied, lift up to open. Position the wire or cable inside the core opening. Close the lid over the cable, pressing down until latch clicks shut. Unlatch Lift Press Click! 1 2 3 Meter: The meter is scaled from 0 to 100. On the 100-mA range, readout is direct (100 = 100 ma). On the 1-A range, move the decimal point 2 places to the left (100 = 1.00 A). To convert meter readings made on the 30 ma, 300 ma, and 3-A ranges, multiply accordingly. For example, a reading of 85 on the 300-mA range equals 300 x.85, or 255 ma. The chart below will help you estimate readings quickly: Range Meter 30 ma 100 ma 300 ma 1 A 3 A 10 3 10 30 0.1 0.3 20 6 20 60 0.2 0.6 30 9 30 90 0.3 0.9 40 12 40 120 0.4 1.2 50 15 50 150 0.5 1.5 60 18 60 180 0.6 1.8 70 21 70 210 0.7 2.1 80 24 80 240 0.8 2.4 90 27 90 270 0.9 2.7 100 30 100 300 1.0 3.0 The <30 ma range is uncalibrated and meter readings represent a relative indication only. It is normal, at high sensitivity, to see some residual meter reading (up to 15%).

Range: The Range switch selects between five calibrated scales (from 30 ma to 3 Amps). The sixth range is uncalibrated and tied to the unit's Sensitivity control. To prevent meter pegging, begin checks on a high range and work down. To estimate unknown current levels, use the formula below (I = Unknown Current in Amps, P = Applied Power in Watts, and R = Load Resistance in Ohms). P I = R Sensitivity: The Sensitivity control varies meter drive when reading weak RF-current levels (below 30 ma). At maximum setting (fully clockwise), RF currents of 1 ma or less will yield a usable meter deflection. This function is especially useful for tracking RFI pickup on household wiring and cables. Note that some residual meter deflection is present with the sensitivity control at maximum. This is normal. Power Switch: Power is applied via a "press-to-test" momentary contact switch. A built-in hold circuit keeps the unit powered for approximately 15-20 seconds after the switch is released. This feature permits "hands-off" measurement on energized conductors. RF Hazard--Important Warnings: 1. RF-current measurements must be conducted with extreme caution. Physical contact with conductors carrying even moderate RF-energy levels can result in severe RF burns, or injury. 2. Do not touch the metal meter case while measuring current with RF levels exceeding 5 Watts or RF voltages exceeding 50 Volts. Power the meter, then apply RF and make measurement "hands-off" using the 15-second power-down feature. 3. Avoid measuring RF current on conductors where high RF voltages may be present (>500 Volts). Damage to your meter may result. Theory of Operation Q1 Timed Switch Line Under Test Sense Coil T1 R2 Calibrate R3 9V Det D2 SW1 <30mA 3A U1a SW2b U1b Sensitivity SW2a <30mA Range 3A M

Induction coil T1 samples common-mode current flowing on the conductor under test. The coil winding is resistively terminated at a low value to minimize circuit perturbation and improve frequency linearity. Trimpot R3 adjusts the level of sampled signals, and is used to calibrate the metering circuit against a known reference. Detector D2 drives the meter movement directly through selected current-limiting resistors on the top three ranges. On the lower three ranges, dual op-amp U1 buffers and amplifies detector output prior to metering. Sensitivity control R1 expands the lowest measurement range-- extending meter sensitivity to the full gain limit of the amplifier. When SW1 is pressed and released, a RC circuit holds dc-switch Q1 in conduction for approximately 15 seconds to permit hands-off measurement. Maintenance In Case of Difficulty: Your meter is inherently trouble-free, but switches, controls, and the meter movement may sustain damage if dropped or exposed to harsh vibration. Also, avoid exposure to rain, snow, extreme heat, or other severe environmental conditions. If you experience a problem, always check battery condition first. If battery replacement fails to resolve the problem, you may contact MFJ Customer Service by phone at 601-323-5869 or reach them via E-mail at mfj@mfjenterprises.com. Be sure to include a complete description of the difficulty. Calibration Instructions: To check meter calibration, use the test set-up shown below: 50-Ohm Dummy Load 7.000 HF Transceiver 50 > In-Line Wattmeter MFJ-854 50-watts should indicate 1.0 Amp of RF current into a 50-ohm RF load. Set the meter's Range selector to 1-A. For meaningful results, your wattmeter must be accurate and the 50-ohm load free of significant reactance. To test, apply a 50-watt CW signal to the load. You should observe a full-scale reading of 1.0-A (100 on the scale). If results vary significantly from this reading, adjust trimpot R3 for the correct indication. Trimpot R3 is located on the unit's pc board below the sense coil. Important Warning: Avoid direct physical contact with this device when making measurements with power sources of over 5 Watts. RF burns or permanent injury may result from contact with high RF voltages. If your meter is out of calibration and you lack the equipment or skills to perform the calibration procedure, you may return it to the MFJ factory for service (see In Case of Difficulty).

Schematic Parts List