MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

Similar documents
MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

MUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3

MUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2

MUELLER E-5TM. and D-5TM. Drilling Machines. Reliable Connections. E-5 General Information 2. D-5 General Information 3. Operating Instructions 4-5

GP-SD GENIE PROBE SMALL DIAMETER

MUELLER. Drilling and Tapping Machine A-3TM. Reliable Connections. table of contents PAGE. General Information 2. Maintenance Instructions 3

Maintenance Information

General Four-Way Operation, Maintenance & Service Manual

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

Fisher 667 Diaphragm Actuators Size 80 and 100

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

Caution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

MUELLER. CL-12 Drilling. Machine. Reliable Connections. Maintenance 2. General Specifications 3-4. Drilling Equipment 4

Operating Instructions for

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

HDL(M)6 Nut/Screw Assembly

RTI TECHNOLOGIES, INC.

Technical Information

MSR/MSB Mechanical Setting Tool

25000 Series Lo-T TM Butterfly Control Valve Instructions

MSR/MSB Mechanical Setting Tool

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS

Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87

RBP-1215B-RX DODGE RAM QUAD CAB RX3

AR15 SUPER SLIM AND ULTRA SLIM FREE FLOAT RAIL SYSTEMS

Water Line and Water Line Assembly Gasket

TECHNICAL INSTRUCTIONS

Installation Instructions

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

Additional Information

DRIVE COMPONENTS REMOVAL. 9. FXCW/C: see Figure Remove bolt (9), sprocket retainer (8), and thrust washer (7). NOTE PRIMARY DRIVE LOCKING TOOL

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

1904, 1904Pg, 1904PgSB, and 1906SB High Capacity Ratchet Knockout Drivers

COYOTE ENTERPRISES, INC. RIMLOC BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

TorqueMaster Replacement Spring

Fisher 657 Diaphragm Actuators Size 80 and 100

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Form No Assembly & Operating Instructions for: SAFETY PRECAUTIONS

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

MODEL SK61732 COMPRESSOR SERVICE KIT

SECTION 7. SAFETYING

Fig Remove chain cover plate bolts. Fig Remove hammer member. Fig Loosen set screws at base of 12-tooth sprocket.

Power Train Lift Max. Capacity: 1,250 lbs.

FIRE PROTECTION PRODUCTS

Installation Instructions 8115F 8115SF

JARVIS. Model Brisket Scissor EQUIPMENT... TABLE OF

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR

Service Manual. Chipper/Shredder - CS4210 and CS4265 IMPORTANT: READ SAFETY RULES AND INSTRUCTIONS CAREFULLY

Click Here to Go Back

Model: SCD430 SCD640. Installation & Operation Guide P/N SCD640-95

Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions

Strata. urniture. Adriana Instructions. Parts in the Arm Box: Parts in the Body Box: Watch our assembly videos at

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Big Block Installation Manual For Systems without A/C

caroma marc newson wall basin mixer

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

HYDRAULIC NUT SPLITTER

CV Control Valves Installation and Operation Manual

INSTALLATION INSTRUCTIONS

Reliance SG777 Series Steel Water Gage Valves

Reliance SG800 Series Steel Water Gage Valves

Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves

Page 1. SureMotion Quick-Start Guide: LACPACC_QS 1st Edition - Revision A 03/15/16

QB78 CO 2 Pellet Rifle

#4500 BULLET SIZER & LUBRICATOR

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

DYNATRAC BALL JOINT REBUILD INSTRUCTIONS V4.0

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

INSTALLATION INSTRUCTIONS

Auto-Spreader Spreader HS10K Hydraulic Flange Spreader

PROSTEER BALL JOINT REBUILD INSTRUCTIONS V1.0

DYNATRAC BALL JOINT REBUILD INSTRUCTIONS V5.0

HARDINGE Installation booklet For: Dead-Length Collet Adaptation Chucks Stationary Collet

MIL-STD B (SH) UPDATE

Mechanical Frappe Press

Maintenance & Parts list for:

AFB (AIR FAN BEARING) INSTALLATION GUIDE

AutoSPLITTER STRAIGHT HEAD MODELS

w w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models

MS25 OPERATION MANUAL

KL50000 Counter Bore OPERATING INSTRUCTIONS. U.S. Patent No CA Patent No

SUPER PRO GUN & SUPER PRO GUN II

SAFETY INSTRUCTIONS. Wear protective clothing, including safety glasses and steel toe boots.

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

General Safety and Maintenance Manual

Universal Projector Ceiling Mount Model: DPM-45

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications

1.1.1 The cube assembly has two filter retainer rings; one is located on the Exciter side and one is on the Emitter side as shown below.

General Safety and Maintenance Manual

LPK1550 Hydraulic Crimping Tool 15-ton

SAVVY OFF ROAD GAS TANK SKID INSTALLATION INSTRUCTIONS

Commercial & Industrial Meter Maintenance Guide

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

8-Ton Manual Splitter OWNER S MANUAL

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

OPERATOR'S MANUAL 46" SNOW BLADE. Model Numbers OEM IMPORTANT: READ SAFETY RULES AND INSTRUCTIONS CAREFULLY

PORTABLE PULL TESTER

General Safety and Maintenance Manual 3 H.P HORIZONTAL GRINDERS. and Thread RPM T1-5/8-11 X 1.9. Lever. Lever. Handle

Transcription:

insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extension 2-3 Improved Fire Hydrant Inserting Extension Section (All Models Prior to 1962) 4-5 Improved Fire Hydrant Inserting Extension Section (Sealed Oil Reservoir 1962 Style) 6-7 Improved Fire Hydrant Inserting Extension Section with Steel Stem Coupling (Sealed Oil Reservoir 1962 Style) 8-9 Modern Improved Fire Hydrant Inserting Extension Section 10-11 107 Fire Hydrant Inserting Extension Section 12-13 Inserting Extension Sections Notes 14-15 Fire Hydrants Inserting Extension Sections TM Reliable Connections Customer Service Center Decatur, Illinois 800.423.1323 www.muellercompany.com moreinfo@muellercompany.com! WARNING: Before working on, or disassembling the Hydrant (including removing any bolts(s) holding the Hydrant together), shut off gate valve to isolate Hydrant from main water source. Loosen (do not remove) one nozzle cap two turns and check for water under pressure inside Hydrant - bleed off any pressure, then remove nozzle cap completely. Open Hydrant main valve completely. A continuous flow of water, no matter how slight, indicates Hydrant is not properly isolated from the main water supply, and that problem must be corrected before any Hydrant disassembly can proceed. Disassembly of Hydrant with pressurized water acting against the main valve could result in unexpected ejection of Hydrant parts, debris or high-pressure water stream, which could cause serious bodily injury.

! MUELLER Centurion Series Fire Hydrant Adding an Extension WARNING: Before removing any bolt(s) holding the Hydrant together, shut off gate valve to isolate Hydrant from main water source. Loosen (do not remove) one nozzle cap two turns and check for water under pressure inside Hydrant bleed off any pressure, then remove nozzle cap completely. Open Hydrant main valve completely. A continuous flow of water, no matter how slight, indicates Hydrant is not properly isolated from the main water supply, and that problem must be corrected before any Hydrant disassembly can proceed. Disassembly of Hydrant with pressurized water acting against the main valve could result in unexpected ejection of Hydrant parts, debris or high-pressure water stream, which could cause serious bodily injury. Tools: Wrench, A-311 operating wrench, pliers. 1. Remove Hold-Down Nut, Anti-Friction Washer and Operating Nut from Bonnet. Lubricate outside of Brass Sleeve and slide over threaded stem end to prevent O-ring damage. Unbolt Bonnet from Upper Barrel and remove. Remove Brass Sleeve. 2. Unbolt Traffic Flange. Remove Upper Barrel. Remove Upper Stem and Stem Coupling by removing the lower stainless steel Cotter Pin and stainless steel Clevis Pin. 3. Place Extension Stem and Extension Coupling on Lower Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. 4. Attach Extension Barrel to Lower Barrel with solid Flange halves (without groove) and Bolts, being sure O-ring is in place. 5. Assemble Upper Stem and Stem Coupling onto Extension Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. NOTE: Make sure Stem Coupling is installed with This End Up towards the Upper Stem. 2

! MUELLER Centurion Series Fire Hydrant Adding an Extension CAUTION: Always fill the oil reservoir with the Bonnet installed, the Hydrant in its normal upright position, and the main valve fully closed. If the Hydrant is filled with lubricant under any other circumstances, excess lubricate can overfill the Bonnet and create a pressure lock. This could result in damage to the seals or Bonnet or prevent proper Hydrant operation. Tools: Wrenches, A-311 operating wrench. 6. Attach Upper Barrel with Traffic Flange Halves (with bevel on outer edge downward) and Bolts; being sure Traffic Flange O-ring* is in groove in Upper Barrel. Tighten Bolts to 60 ft-lbs. 7. Check Bonnet O-ring* for proper position and condition. Attach Brass Sleeve to Upper Stem and lubricate outside to protect O-ring Seals from thread damage. Place Bonnet onto Upper Barrel and assemble Bonnet Bolts only hand-tight. Remove Brass Sleeve. Reassemble Operating Nut, Anti-Friction Washer, and Hold-Down Nut (snug-tighten). Be sure O-ring Seals are in good condition at thread shoulder on outside of Hold-Down Nut and on inside where contact is made with Operating Nut. 8. Remove Oil Filler Plug in side of Bonnet. Pour MUELLER Hydrant Lubricant into Oil Reservoir until it is level with Oil Filler Plug Hole. Replace Oil Filler Plug (see Lubrication section on page 8). 9. Torque Bonnet Bolts to 40-80 ft-lbs. Torque Hold-Down Nut to 200-300 ft-lbs. after Bonnet Bolts are tight. Open Gate Valve. Unscrew one Hose Nozzle Cap slightly to bleed air. Open Hydrant fully. Tighten Hose Nozzle Cap when water starts flowing and check all flange connections for leaks. Turn Operating Nut to fully closed position and remove Hose Nozzle Cap to allow Barrel to drain. Replace Hose Nozzle Cap. 10. Turn Operating Nut in closing direction to make sure Main Valve is closed tightly, then turn in opening direction approximately 1/4 turn to relieve tension on operating mechanism. *To determine correct O-rings for Bonnet and Ground Line flanges, which are similar in appearance: smaller diameter O-ring is used at Bonnet flange; larger at Ground line flange. 3

MUELLER Improved Fire Hydrant Inserting Extension Section (All Models Prior to 1962) Equipment & ToolS Needed PPE: Safety shoes, safety vest, safety glasses, work gloves. Tools: 1 /4 hex-head wrench, A-51 lubricating oil, A-311 operating wrench, A-367 brass sleeve. 1. Remove four Bonnet Bolts and turn operating nut in the opening direction until free of stem. Remove Bonnet. 2. Remove four bolts in stuffing box. Lubricate A-366 Brass Sleeve. Slide Sleeve over threaded area of stem to protect O-rings from damage by threads. Lift stuffing box off carefully. Remove Brass Sleeve. 3. Unbolt Traffic Flange and remove Upper Barrel. Unscrew set screw in Sleeve. Screw Stem Coupling down against shoulder. Slide Sleeve up and unscrew Upper Stem from Stem Coupling. Unscrew Stem Coupling from Lower Stem. Screw Extension Stem Coupling down on Lower Stem against shoulder. 4. Screw Extension Stem into Extension Coupling until it contacts Lower Stem. Align tongue and groove of stems with hole in Extension Stem Coupling. Screw Extension Stem Coupling upward until tongue and groove of stems firmly lock together. Tighten with wrench, then, screw in Set Screw in Extension Stem Coupling. 5. Place new Stem Coupling Sleeve part onto Upper Stem. Screw new Stem Coupling part onto Lower Stem as far as threads permit. Screw Upper Stem into Stem Coupling until it contacts the Lower Stem. Turn Stem Coupling and Upper Stem so that slot in Thimble aligns with the tongue and groove of stems. Hold Upper Stem in alignment and screw Stem Coupling upward until tongue and groove of stems firmly lock together. Tighten with wrench. With Stem Coupling in place, slide Sleeve downward so that lower end of sleeve surrounds upper end of Stem Coupling. Be sure Sleeve projections fit into Stem Coupling slots. With Sleeve in place, tighten set screw in Sleeve. 4

MUELLER Improved Fire Hydrant Inserting Extension Section (All Models Prior to 1962) Equipment & ToolS Needed PPE: Safety shoes, safety vest, safety glasses, work gloves. Tools: 1 /4 hex-head wrench, A-51 lubricating oil, A-311 operating wrench, A-367 brass sleeve. 6. 7. Attach Extension Barrel to Lower Barrel with solid Flange Halves (without groove) and bolts, being sure Flange Gasket is in place. Attach Upper Barrel to Extension Barrel with Traffic Flange Halves (with groove) and bolts, being sure Flange Gasket is in place. 8. Check Stuffing Box Gasket. Lubricate A-366 Brass Sleeve. Slide Sleeve over threaded area of stem to protect O-rings from damage by threads. Place Stuffing Box in position and bolt to barrel. Remove Brass Sleeve. Pour Mueller Hydrant Lubricant into Oil Reservoir until 3 /4 from top. Turn Operating Nut in the 10. closing direction to make sure Main Valve is closed, then turn in the opening direction approximately 1/4 turn to relieve tension on the operating mechanism. 9. Replace bonnet. Turn Operating Nut in closing direction to engage stem. If Bonnet has Filler Plug, make sure that the Filler Plug Hole is aligned with the offset portion of the Oil Reservoir. Bolt in place. 5

MUELLER Improved Fire Hydrant Inserting Extension Section (Sealed Oil Reservoir 1962 Style) Tools: Wrench, A-316 nozzle wrench, brass hammer. 1. 2. 3. Remove Weather Cap, Hold Down Nut and Operating Nut from Bonnet. Lubricate A-366 Brass Sleeve and slide over threaded stem end to prevent O-ring damage. Unbolt Bonnet from Upper Barrel and remove. Remove Brass Sleeve. Unbolt Traffic Flange and remove Upper Barrel. Unscrew set screw in Sleeve. Screw Stem Coupling down against shoulder. Slide Sleeve up and unscrew Upper Stem from Stem Coupling. Unscrew Stem Coupling from Lower Stem. Screw Extension Stem Coupling down on Lower Stem against shoulder. Screw Extension Stem into Extension Coupling until it contacts Lower Stem. Align tongue and groove of stems with hole in Extension Stem Coupling. Screw Extension Stem Coupling upward until tongue and groove of stems firmly lock together. Tighten with wrench, then screw in set screw in Extension Stem Coupling. 4. Place new Stem Coupling Sleeve part onto Upper Stem. Screw new Stem Coupling part onto Lower Stem as far as threads permit. Screw Upper Stem into Stem Coupling until it contacts the Lower Stem. Turn Stem Coupling and Upper Stem so that slot in Thimble aligns with the tongue and groove of stems. Hold Upper Stem in alignment and screw Stem Coupling upward until tongue and groove of stems firmly lock together. Tighten with wrench. With Stem Coupling in place, slide Sleeve downward so lower end of sleeve surrounds upper end of Stem Coupling. Be sure Sleeve projections fit into Stem Coupling slots. With Sleeve in place, tighten set screw in Sleeve. 5. Attach Extension Barrel to Lower Barrel with solid Flange Halves (without groove) and bolts, being sure Flange Gasket is in place. 6. Attach Upper Barrel to Extension Barrel with Traffic Flange Halves (with groove) and bolts, being sure Flange Gasket is in place. 6

MUELLER Improved Fire Hydrant Inserting Extension Section (Sealed Oil Reservoir 1962 Style) Tools: Wrench, A-367 brass sleeve, A-359 seat wrench, A-311 operating wrench. Turn Operating Nut in the 9. closing direction to make sure Main Valve is closed, then turn in the opening direction approximately 1/4 turn to relieve tension on the operating mechanism. 7. 8. Check Bonnet Gasket. Attach the A- 24099 Brass Sleeve, if it had been removed, to Upper Stem and lubricate outside to protect O-ring seals from thread damage. Place Bonnet onto Upper Barrel and assemble Bonnet Bolts only hand tight. Remove Brass Sleeve. Reassemble Operating Nut and remove Oil Plug in side of Bonnet. Pour Mueller Hydrant Lubricant into Oil Reservoir until it is filled to the level of the Oil Plug. Replace Oil Plug. Replace Hold Down Nut* being sure O-ring seals are in good condition at thread shoulder on outside of Hold Down Nut and on inside where contact is made with Operating Nut. Replace Weather Cap. Tighten Bonnet Bolts. Check gasket tightness by opening one hose cap slightly before opening Hydrant to bleed air. Open Hydrant until barrel fills with water, tighten Hose Cap, open Hydrant fully. Check gaskets, and then turn Operating Nut to fully closed position. *Tighten hold down nut to 200-300 ft-lbs of torque. If torque wrench is not available, use a 3 lb hammer to strike the end of the A-311 wrench firmly two times to assure the nut is properly tightened. 7

MUELLER Improved Fire Hydrant Inserting Extension Section with Steel Stem Coupling (Sealed Oil Reservoir 1962 Style) Tools: Wrench, A-316 nozzle wrench, brass hammer. 1. 2. 3. Remove Weather Cap, Hold Down Nut and Operating Nut from Bonnet. Lubricate A-366 Brass Sleeve and slide over threaded stem end to prevent O-ring damage. Unbolt Bonnet from Upper Barrel and remove. Remove Brass Sleeve. Unbolt Traffic Flange and remove Upper Barrel. Remove Upper Stem and Stem Coupling by removing the lower stainless steel Cotter Pin and stainless steel Clevis Pin. Place Extension Stem and Extension Coupling on Lower Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. 4. Assemble Upper Stem and Stem Coupling onto Extension Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. Make sure Stem Coupling is installed with notches towards the Lower Stem, words this end up towards the Upper Stem. 5. Attach Extension Barrel to Lower Barrel with solid Flange Halves (without groove) and bolts, being sure Flange Gasket is in place. 6. Attach Upper Barrel to Extension Barrel with Traffic Flange Halves (with groove) and bolts, being sure Flange Gasket is in place. 8

MUELLER Improved Fire Hydrant Inserting Extension Section with Steel Stem Coupling (Sealed Oil Reservoir 1962 Style) Tools: Wrench, A-366 brass sleeve, A-359 seat wrench, A-311 operating wrench. Turn Operating Nut in the 9. closing direction to make sure Main Valve is closed, then turn in the opening direction approximately 1/4 turn to relieve tension on the operating mechanism. 7. 8. Check Bonnet Gasket. Attach the A-366 Brass Sleeve, if it had been removed, to Upper Stem and lubricate outside to protect O-ring seals from thread damage. Place Bonnet onto Upper Barrel and assemble Bonnet Bolts only hand tight. Remove Brass Sleeve. Reassemble Operating Nut and remove Oil Plug in side of Bonnet. Pour Mueller Hydrant Lubricant into Oil Reservoir until it is filled to the level of the Oil Plug. Replace Oil Plug. Replace Hold Down Nut* being sure O-ring seals are in good condition at thread shoulder on outside of Hold Down Nut and on inside where contact is made with Operating Nut. Replace Weather Cap. Tighten Bonnet Bolts. Check gasket tightness by opening one hose cap slightly before opening Hydrant to bleed air. Open Hydrant until barrel fills with water, tighten Hose Cap, open Hydrant fully. Check gaskets, and then turn Operating Nut to full closed position. *Tighten hold down nut to 200-300 ft-lbs of torque. If torque wrench is not available, use a 3 lb hammer to strike the end of the A-311 wrench firmly two times to assure the nut is properly tightened. 9

MUELLER Modern Improved Fire Hydrant Inserting Extension Section Tools: Wrench, A-316 nozzle wrench, brass hammer. 1. 2. 3. Remove Weather Cap, Hold Down Nut, Lock Washer and Operating Nut. Put on Brass Sleeve and lubricate to protect O-rings in operating housing. Unbolt Traffic Flange Clips and lift hydrant over stem. Remove Upper Stem and Stem Coupling by removing the lower stainless steel Cotter Pin and stainless steel Clevis Pin. 4. Place Extension Stem and Extension Coupling on Lower Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. 5. Assemble Upper Stem and Stem Coupling onto Extension Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. Make sure Stem Coupling is installed with notches towards the Lower Stem. NOTE: This End Up stamped on coupling. 6. Attach Extension Barrel to Lower Barrel with solid flange halves and bolts, being sure Flange Gasket is in place (tighten bolts to 1,000 in-lbs). 10

MUELLER Modern Improved Fire Hydrant Inserting Extension Section Tools: Wrench, A-316 nozzle wrench, brass hammer. 7. 8. 9. With lubricated Brass Sleeve on threads of Upper Stem and Upper Barrel Seal in position, lift Upper Barrel over Upper Stem and onto extension section Attach Traffic Flange Clips and Traffic Flange Clip Bolts loosely, face nozzles in desired position and tighten Traffic Flange Clip Bolts uniformly to 1,000 in-lbs. With extension section and Hydrant securely bolted in place, remove Brass Sleeve, replace Operating Nut, Lock Washer, and Hold Down Nut. Tighten Hold Down Nut to 100 ft-lbs and bend Lock Washer Ears over Hold Down Nut flats in two places and over Operating Housing in two places. Open Hydrant fully and loosen 11. one Hose Nozzle Cap, to bleed air. When barrel is filled with water, tighten Nozzle Cap and check gaskets. Turn Operating Nut to fully closed position, loosen one nozzle cap to allow barrel to drain. Turn Operating Nut in the 12. closing direction to make sure Main Valve is closed, then turn in the opening direction approximately 1/4 turn to relieve tension on the operating mechanism. 10. Remove Oil Filler Plug and add Mueller Hydrant Lubricant until level with Filler Plug hole. Replace Oil Filler Plug and replace Weather Cap. 11

MUELLER 107 Fire Hydrant Inserting Extension Section Tools: Wrench, A-316 nozzle wrench, brass hammer. 1. 2. 3. Remove Bonnet Bolts and Nuts. Rotate Operating Nut in opening direction to fully opened position. This lifts Bonnet off the Upper Barrel. Rotate bonnet assembly counter-clockwise to detach Bonnet from Upper Stem threads. Lift off Bonnet, remove Bonnet Gasket. Unbolt Traffic Flange and remove Upper Barrel. Remove Upper Stem and Stem Coupling by removing the lower stainless steel Cotter Pin and stainless steel Clevis Pin. Place Extension Stem and Extension Coupling on lower stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. 4. Assemble Upper Stem and Stem Coupling onto Extension Stem and retain it with stainless steel Clevis Pin and stainless steel Cotter Pin. Make sure Stem Coupling is installed with notches towards the Lower Stem, words this end up towards the Upper Stem. 5. Attach Extension Barrel to Lower Barrel with solid flange halves (without groove) and bolts, being sure flange gasket is in place. 6. Attach Upper Barrel to Extension Barrel with Traffic Flange halves (with groove) and bolts, being sure Traffic Flange Gasket is in place. 12

MUELLER 107 Fire Hydrant Inserting Extension Section Tools: Wrench, A-316 nozzle wrench, brass hammer. Turn Operating Nut in the 8. closing direction to make sure Main Valve is closed, then turn in the opening direction approximately 1/4 turn to relieve tension on the operating mechanism. 7. Check Bonnet Gasket on top of Upper Barrel, replace if damaged. Check to see that Upper Stem threads are lubricated and Upper Stem Seal (O-ring) is not damaged. Check to be sure that the Operating Nut is in the fully open position, which is with the Stem Nut fully extended. Reassemble Bonnet Assembly to Upper Stem by rotating clockwise as far as possible, then back up only enough to align bolt holes, if needed. Rotate Operating Nut in closing direction, which lowers Bonnet Assembly onto Upper Barrel and allows bolts to be replaced. With all bolts in Bonnet, rotate Operating Nut using the same torque as normally used to close the Hydrant. Tighten all Bonnet Bolts and Nuts. 13

Inserting Extension Sections Notes 14

Inserting Extension Section Notes 15

TM Reliable Connections Water (U.S.) 1.800.423.1323 www.muellercompany.com moreinfo@muellercompany.com Water (Canada) 1.705.719.9965 www.muellercanada.com more-info@muellercanada.com International 1.423.490.9555 www.mueller-international.com international@muellercompany.com Copyright 2016 Mueller Co., LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Mueller Co., LLC, its affiliates or other third parties. Products marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your Mueller Sales or Customer Service Representative concerning any other application(s). Form 10923 - Rev 09/17