SCXI Terminal Block

Similar documents
SCXI TERMINAL BLOCK

SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

The following conventions apply to this document:

Contents. Software Requirements. Documentation Requirements. Calibration Interval CALIBRATION PROCEDURE NI TB-4300B

NI sbrio-9632/9642 Verification Procedure

NI PXIe Contents. Required Software CALIBRATION PROCEDURE. Dual-Output Programmable DC Power Supply

NI 6624 Calibration Procedure

NI PXIe Contents CALIBRATION PROCEDURE. Single-Channel Precision Source-Measure Unit (SMU)

Contents. Software Requirements

NI PXIe Contents CALIBRATION PROCEDURE. Four Channel Precision Source-Measure Unit (SMU)

CALIBRATION PROCEDURE NI PXIe-4330/4331. Contents

NI PXI-4110 Calibration Procedure Addendum

CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

PXIe Contents. Required Software CALIBRATION PROCEDURE

PXIe, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

NI PXIe-5171R. Contents. Required Software CALIBRATION PROCEDURE

TBX-68S Isothermal Terminal Block

NI PXI ½ Digit FlexDMM Calibration Procedure

NI SCXI Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

PXIe Contents. Required Software CALIBRATION PROCEDURE

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

SCC-ACC01 Accelerometer Input Module

SCC-FV01 Frequency Input Module

SCXI High-Voltage Terminal Block

Contents. CALIBRATION PROCEDURE NI PXIe-5698

Contents. CALIBRATION PROCEDURE NI PXIe-4463 DSA Analog Output

if it is used in a manner not described in the user documentation.

Required Software. Related Documentation. Password. Calibration Interval

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

NI PXI-2530 Specifications

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

SCXI High-Voltage Terminal Block

is used in a manner not described in the user documentation.

NI 6143 Specifications

NI PXI/PXIe-2532 Specifications

SPECIFICATIONS FOR THE NI PXI/PCI-4060

Contents CALIBRATION PROCEDURE NI PXI-5422

BNC-2121 Connector Accessory for 660X Devices

SCC-DI01 Isolated Digital Input Module

Contents. CALIBRATION PROCEDURE NI 5421/ MS/s Arbitrary Waveform Generator

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

Specifications for the NI PXI/PCI-6552/6551

PXIe Contents CALIBRATION PROCEDURE. 10 GHz or 20 GHz RF Analog Signal Generator

Contents. CALIBRATION PROCEDURE PXIe-5673 Vector Signal Generator

NI PXI-2532 Specifications

NI Channel SPST Electromechanical Relay Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

NI 4070/4072 6½-Digit FlexDMM

NI 6013/6014 Family Specifications

NI PXI/PCI-5411/5431 Specifications

NI Channel, Universal Digital Input Module

SCC-CO20 Isolated Current Output Module

NI PXIe-5601 Specifications

PXIe, 24-Channel, ±24 V, 50 ma Precision PXI Source Measure Unit

SCXI MHz Quad 8x1 50 Ω Multiplexer

Measuring Temperature with an RTD or Thermistor

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-5663E

NI PXI/PCI-5411/5431 Specifications

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

NI DAQPad -6020E Family Specifications

Contents. Software Requirements CALIBRATION PROCEDURE NI PXI-5663

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

Contents. Software. Documentation. CALIBRATION PROCEDURE NI PXIe-6674T

NI PXI/PXIe-2529 Specifications

OPERATING INSTRUCTIONS NI Channel, 24-Bit, Universal Analog Input Module

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

Eight-Channel Thermocouple Input Module

NI 6731/6733 Specifications

NI 6023E/6024E/6025E Family Specifications

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

Contents. USER MANUAL NI ISM-7400 Integrated Stepper

NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

NI PXI-4461 Specifications

670K9 SORtrax Level Transmitter

NI PXI-2521 Specifications 40-Channel DPST Relay Module

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

Contents. CALIBRATION PROCEDURE NI PXIe-6555/6556. ni.com/manuals

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

NI PXI-2520 Specifications 80-Channel SPST Relay Module

NI PXIe-5630 Specifications

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

NI Introduction. Contents CALIBRATION PROCEDURE

NI PXI-2557 Specifications

NI Channel, 24-Bit, Universal Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, ±10 V, 16-Bit Simultaneous Analog Input Module. ni.com/manuals

Contents CALIBRATION PROCEDURE NI 5412

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

FP-DO-400 and cfp-do-400

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

Analog Characteristics

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

Transcription:

CALIBRATION PROCEDURE SCXI -1322 Terminal Block What Is Calibration? Why Calibrate? This document contains information and step-by-step instructions for verifying the temperature sensor performance of the National Instruments SCXI-1322 terminal block. For SCXI-1322 terminal blocks, calibration is simply determining the measurement accuracy of the components on the SCXI-1322. Because these components are not user-adjustable, calibration consists of a verification procedure only. Electronic components drift with time, which can affect measurement accuracy as the device ages. Calibration ensures that your SCXI-1322 terminal block is still meeting NI standards. If the results of the procedure indicate that your terminal block is out of specification, return it to NI for repair. How Often Should You Calibrate? The measurement accuracy requirements of your application determine the calibration interval of your SCXI-1322 terminal block. NI recommends you perform a complete calibration at least once every year. You can shorten this interval to six months or 90 days, based on the demands of your application.

Equipment and Other Test Requirements This section describes the equipment, software, documentation, and test conditions needed for verification. Test Equipment Verification requires a high-precision voltage source with at least 50 ppm accuracy, and a multiranging 5 1/2 digit digital multimeter (DMM) with 15 ppm accuracy. Software and Documentation NI recommends you use the following instruments for verification of an SCXI-1322: Calibrator Fluke 5700A DMM NI 4070 or HP 34401A If these instruments are not available, use the accuracy requirements previously listed to select a substitute calibration standard. No software is required to verify the operation of the SCXI-1322. All required documentation is found in this calibration procedure. However, if you would like more information on the product, refer to the SCXI-1322 High-Voltage Terminal Block Installation Guide. Test Conditions Follow these guidelines to optimize the connections and the environment during verification: Keep connections to the SCXI-1322 short. Long cables and wires act as antennae, picking up extra noise that can affect measurements. Use shielded copper wire for all cable connections to the device. Use twisted-pair wire to eliminate noise and thermal offsets. Keep relative humidity below 80%. Maintain temperature between 15 C and 35 C. Allow a warm-up time of at least 15 minutes to ensure that the circuitry is at a stable operating temperature. SCXI-1322 Terminal Block Calibration Procedure 2 ni.com

Verification Procedure 1. Connect a +5 VDC power source to the terminal block. a. Hold the SCXI-1322 vertically and view it from the rear. The terminals on the 96-pin DIN connector are illustrated in Figure 1. 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Column C B A Figure 1. SCXI-1322 96-Pin DIN Connector National Instruments Corporation 3 SCXI-1322 Terminal Block Calibration Procedure

This conforms to the labeling of the pins on the front connector of a matching SCXI terminal block. It does not necessarily correspond to labeling of the pins on the rear of the terminal block connector itself, which you can only view by opening the terminal block enclosure. b. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A7 on Attach the other end of this wire to the positive terminal of the +5 VDC power supply. c. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A1 on Attach the other end of this wire to the negative terminal of the +5 VDC power supply. 2. Connect a calibrated DMM to the temperature sensor output of the terminal block. a. Strip 12.7 mm (0.5 in.) of insulation from one end of a 22 AWG solid wire. Insert the stripped end of the wire into terminal A3 on Attach the other end of this wire to the positive input terminal of the calibrated DMM. b. Connect the negative input terminal of the calibrated DMM to the negative terminal of the +5 VDC power supply. 3. Place the terminal block in a temperature-controlled environment where the temperature is between 15 C and 35 C. 4. When the terminal block temperature has equilibrated with its surroundings, measure the temperature sensor output V meas using a calibrated DMM. 5. Measure the actual temperature T act in the temperature-controlled environment using a calibrated temperature-measurement instrument. SCXI-1322 Terminal Block Calibration Procedure 4 ni.com

6. Convert V meas (in volts) to measured temperature T meas (in C) by performing the following calculation. a. Calculate. b. Calculate. x = 2.5 V -------------------------- meas 5000 c. Calculate. y = ln V meas ------------ x 1 T meas = --------------------------------- 273.15 a + y( b + cy 2 ) where 7. Compare T act to T meas. a = 1.295361 10 3 b = 2.343159 10 4 c = 1.018703 10 7 If (T meas 0.65 C) T act (T meas + 0.65 C), you have verified that the operation of the terminal block temperature sensor is within its specifications. If T act < (T meas 0.65 C), the temperature sensor is nonfunctional. Return the terminal block to NI for repair or replacement. If T act > (T meas + 0.65 C), the temperature sensor is nonfunctional. Return the terminal block to NI for repair or replacement. You have completed the calibration verification procedure for the SCXI-1322. National Instruments, NI, and ni.com, and SCXI are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2000 2004 National Instruments Corp. All rights reserved. *370255B-01* 370255B-01 Aug04