UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Similar documents
Microwave Meter. Instruction Manual

Mini Environmental Quality Meter

Sound Meter Type

Smartphone RH/Temperature Probe Instruction Manual

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

INSTRUCTION MANUAL INF Fax: (503)

TLKR T60 OWNER'S MANUAL EN DE FR IT ES PR NL DA NO TU PL SV RU

SAFE USE &OPERATIONS MANUAL

Digital Wireless Weather System

Non-contact Forehead IR Thermometer

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

Instruction Manual TS

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

IR-829 Infrared Thermometer User Manual

DM-46 Instruction Manual

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

DM-46 Instruction Manual

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

OWNER'S MANUAL 5 PC DINING SET DATE OF PURCHASE: NOTE: MODEL #: DASE3583 UPC CODE: RECEIPT OF PURCHASE: ATTACH HERE NEED HELP!

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

Dawson DSM150. Digital Light Meter User s Manual

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

INSTRUCTION MANUAL UTL260

WBGT Heat Index Meter TT-563

MICROSCANNER TM D-Series

RF/High Frequency Meter HF-A3G

WS-9006U Wireless Temperature Station

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

Instruction Manual. IM Axis RF Field Strength Meter

SPM-50 RF Spectrum Power Meter PC Software User Manual

OWNER'S MANUAL BENCH NOTE: THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION PLEASE READ AND KEEP FOR FUTURE REFERENCE.

Model E201. Wide Range RF Field Strength Meter

MW-C WALL MOUNT ADAPTER. For MD-ASL15W and MD-BSL15W Monitor Mounts. User Manual

7/05 FORM#352 OPERATING INSTRUCTIONS ALL WEATHER DIGITAL LEAKAGE CURRENT TESTER DSA-2417

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

RF EMF Strength Meter

Model E200 3-Axis RF Field Strength Meter

DOREL ASIA COUNTER HEIGHT DESK NEED HELP! Model No: WM3514 UPC CODE:

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

Operating Instructions Digital Verticality Meter For use with USP Apparatus #1 & #2

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Handheld Infrared Thermometers

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Dawson DDM190. Digital Multimeter User s Manual

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

User's Manual. Model f/1f Power Clamp-on Meter

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

PIN/PINLESS DEEP SENSING MOISTURE METER WITH SPHERICAL SENSOR AND REMOTE PROBE

RF EMF Strength Meter

USER GUIDE. IR Thermal Scanner. Model IRT500

2 Pack CH Dining Chairs

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

True RMS AC / DC Power Clamp Meter Model

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

Wireless Pressure Station with Backlight

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Model 7000 Low Noise Differential Preamplifier

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

TRACEABLE RADIO-SIGNAL REMOTE THERMOMETER INSTRUCTIONS

OVA-50 Optical Variable Attenuator User s Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ELECTROSMOG METER INSTRUCTION MANUAL

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

Digi-Stop. Installation & Operation

Pro Triple Axis RF/High Frequency Meter HF-B8G. User s Manual HB4HFB8G0000

User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

312, 316, 318. Clamp Meter. Users Manual

Radiant Pro 2500 Video Light (Cat. No. 6047)

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

INSTRUCTION MANUAL Milwaukee Lab Photometer Mi490 Peroxide value

Space Invaders OPERATING MANUAL. Model # 402-1

CLAMP-ON METER 670. User Manual

eflex 75x/300x Digital Microscope with Flexible Neck User Guide

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

Contents. English 1. French 29. Spanish. FEATURES: The Temperature Station

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Firmware Version d & higher Installation & Operation

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

DIGITAL OXYGEN METER. Model : DO-5510

DOREL ASIA SLIM RECLINER NEED HELP! Model No: WM3451 UPC CODE: Lot number: Date of purchase:

PORTROD WALL MOUNTED HEIGHT ROD

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Owner s Manual PMR 446 Handheld transceiver G5

Fit IPL-R. Instruction Manual (Rev06 - Jun 2018; Firm. Vers.11)

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

RF EMF Strength Meter

Owner s Manual. Model G-223. GMRS/FRS Radio. FEATURES 22 Channels Scan 22 Key Pad Lock Call Alert Power HI/LO Roger Beep Tone

2013 MFJ ENTERPRISES, INC.

Exercise Heart Rate Sensor

EasyView Light Meter with Memory

Texas Hold Em Operating Manual

Transcription:

UVA/B Light Meter 850009 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED UVA/B Light Meter 850009 Instruction Manual Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com

CONTENTS INTRODUCTION... 4 FEATURES... 5 MATERIALS SUPPLIED. 6 LCD DISPLAY... 7 BASIC FUNCTIONS... 8 MODE AND UNIT SELECTION... 10 MEMORY... 14 UVA/B SENSOR. 17 BATTERY REPLACEMENT.. 19 MAINTENANCE.. 20 SPECIFICATIONS... 21 OPTIONAL ACCESSORIES... 22 WARRANTY... 23 INTRODUCTION The Sper Scientific UVA/B Light Meter (Model 850009) is a light-weight, portable instrument that measures damaging UV (ultraviolet) light in both natural and manmade environments. The UV Light Meter measures long and medium wave UV-A/B light for applications such as forensics, chromatography, electrophoresis and dermatology. You can use the meter almost anywhere to determine UV light intensity and avoid the harmful effects of overexposure. - 3 - - 4 -

Tripod Mounting Socket High and low measurement range in milliwatts per square centimeter (mw/cm 2 ) or microwatts per square centimeter (µw/cm 2 ) Backlit LCD Magnetic Mount Simultaneous Display of Minimum, Maximum, Average and Recorded Data Zero Point Reset Hold Function 4 Digit Dual Display 20 Points Memory FEATURES Automatic Measuring Low Battery Indicator MATERIALS SUPPLIED Meter UV Probe Magnetic Mount 9 Volt Battery Instruction Manual Hard Carrying Case - 5 - - 6 -

LCD DISPLAY BASIC FUNCTIONS 1. Mode 2. Primary Reading 3. Data Log 4. Auto Mode 5. Memory Review 6. Data Hold 7. Record 8. MAX/MIN/AVG 9. Secondary Reading 10. Time Unit 11. Unit of Measure 12. UV Type 13. Low Battery - 7 - Power On/Off 1. Press and hold the HOLD button for 2 seconds to turn the meter on. All symbols on the LCD will appear for 1 second. 2. Press and hold the HOLD button for 2 seconds to turn the meter off. All symbols on the LCD will appear for 1 second. Release HOLD button. Reading the LCD Display 1. The primary display indicates measurement value. 2. The secondary display indicates the advanced functions or data recording. - 8 -

BASIC FUNCTIONS Meter Function Flow Chart 1. Press MODE to choose the main function (MAX/MIN/AVG, Zero, Unit, Type or Time). MAX/MIN/AVG Mode is Normal Mode for this meter and has several sub-functions as indicated in the diagram below. MODE AND UNIT SELECTION Mode Selection 1. Press MODE continuously to cycle through MAX/MIN/AVG, Zero, Unit, Type, and Time Modes, respectively. Maximum, Minimum and Average (Normal Mode) 1. Press MODE continuously to cycle through modes until you reach MAX/MIN/AVG. 2. The current measured value appears on the primary display. 3. To view minimum, maximum or average values of the current reading, press S continuously to select subcategory modes of None, Maximum hold, Minimum hold, and Average hold, respectively. 4. Maximum, minimum and average values will appear and freeze on the secondary display and will update only when a new maximum, - 9 - - 10 -

MODE AND UNIT SELECTION minimum, or average value is reached on the primary display. Then the secondary display updates automatically. The average value on the secondary display updates according to the detected maximum and minimum values of the current reading. 4. Press M to save the current, max, min, or avg value for each data point and the meter will move to the next data point. The stored data can hold either one current, max, min, or avg value for each data point. 5. Press S to reset. Data Hold 1. While in Normal Mode, press HOLD to freeze the secondary display value. HOLD will appear on the bottom left corner of the LCD. 2. Press HOLD to cancel Hold Mode. - 11 - MODE AND UNIT SELECTION Zero Adjustment 1. Press MODE continuously to cycle through modes until you reach Zero Mode. 2. Cover the sensor. If the main display has a reading other than zero, perform the zero adjustment. 3. Cover the sensor and press S to zero adjust. The secondary display indicates the adjustment value for your reference. 4. Press and hold S for 1 second to clear the adjustment value. Note When the adjustment value is over 10 µw, the measurement value cannot be offset. The main display will show the above range reading, and the secondary display will show -Err. Repeat the zero adjustment procedure or contact Sper Scientific. - 12 -

MODE AND UNIT SELECTION 5. In Zero Mode, press M to clear data points 0 to 20. Unit Selection 1. Press MODE continuously to cycle through modes until you reach Unit Mode. 2. Press S to choose the unit of measure: µw/ cm 2 or mw/cm 2. Type Selection This function is reserved for use in future models. Manual Recording MEMORY In Normal Mode, press M to store the current value that appears on the primary display. The flashing DATA(01~20) icon stops flashing for 2 seconds and moves to the next storage location. (Refer to Maximum, Minimum and Average/Normal Mode on pages 10-11 for instructions on saving max, min, and avg values.) Auto Recording To utilize auto recording, you must first set an interval time for recording measurement values. Interval Time Setting 1. Press MODE continuously to cycle through modes until you reach Time Mode. - 13-2. Continuously press S to select an interval time for auto recording of 1, 2, 5, 10, 30 seconds or 1, 3, 5, 10 minutes. - 14 -

To Auto Record: MEMORY 1. In Normal Mode, press and hold M for 2 seconds. AUTO appears next to REC on the LCD. As soon as the meter reaches 20 data points, the unit will turn off. Recorded data includes: Irradiation intensity, Max/Min/Avg and unit of measure 2. Press M to cancel Auto-Record Mode. Memory Recall 1. In Normal Mode, press HOLD. 2. Press M to enter Memory Mode. MEM will appear above HOLD on the LCD. 3. Press S to review data points 0 to 20 on the secondary display. Data point 0 indicates the set time interval between readings when in Auto-Record Mode. (Refer to Interval Time Setting section for instructions.) If the data - 15 - MEMORY were automatically recorded, AUTO appears next to MEM during the recall. 4. As you scroll through data points 0 to 20, the saved minimum, maximum, or average value appears on the secondary display. 5. The MAX, MIN or AVG icon will appear on the bottom of the LCD next to the data point number to indicate whether the secondary display represents a maximum, minimum, or average value for that data point. If none of these icons appear, the value represents a stored value at that data point that is not a minimum, maximum or average value. Clear Data 1. Press MODE to select Zero Mode. 2. Press M to clear all 20 stored data points. - 16 15 -

UVA/B SENSOR UVA/B SENSOR Relative Spectral Sensitivity (%) Wavelength (nm) Calibration Point CAUTION: THE UV SENSOR IS A SENSITIVE INSTRUMENT. TO PREVENT PREMATURE AGING AND THERMAL DESTRUCTION OF THE SENSOR, USE THE SENSOR FOR SHORT-TERM MEASUREMENT IN A SPLASH- PROOF ENVIRONMENT ONLY. THE HOUSING TEMPERATURE MUST NOT EXCEED 50 C. STORE IN A DRY ENVIRONMENT. Portable Handheld Use 1. Upper casing 2. Sensor 3. Lower casing 4. Self-tapping screws x 1 x 1 x 1 x 5 Note To avoid wearing the screw holes, limit the number of times you assemble and disassemble the probe. - 17 - - 18 -

BATTERY REPLACEMENT This unit requires one 9 Volt battery. The icon indicates a low battery. To replace: 1. Slide off battery cover from the back of the unit. 2. Insert a 9V battery ensuring correct polarity. MAINTENANCE 1. Dampen a sponge or soft cloth with soap and water to clean the housing. 2. Take care to prevent any liquids or moisture from getting inside the unit during cleaning. 3. Replace battery cover. - 19 - - 20 -

UV Range 1 (Low Illumination) UV Range 2 (High Illumination) Resolution Accuracy Wavelength Calibration Point Temperature Range Meter Dimensions SPECIFICATIONS 1 µw/cm 2 ~ 9999 µw/cm 2-21 - 1µW/cm 2 and 0.01 mw/cm 2 ±4% ±1 digit (at 23 ±5 C) 280 ~ 400 nm 365 nm 0 ~ 50 C 6 x 2 x 1½ (145 x 55 x 40 mm) Weight 4.4 oz (135 g) Sensor Dimensions 0.01 mw/cm 2 ~ 40.00 mw/cm 2 Diameter = 35 mm H = 25.5 mm OPTIONAL ACCESSORIES 840090 Water Resistant Instrument Pouch 840092 Bench-Top Tripod 840093 Field Tripod - 22 -

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for five (5) years from the date of purchase and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted, if available. This warranty does not cover damage resulting from accident, misuse, or abuse of the product. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 7720 E. Redfield Rd, Suite 7, Scottsdale, AZ 85260 Email: info@sperscientific.com Be sure to include a description of the problem and your return address. Register your product online at www.sperscientific.com or return your warranty card within 10 days. Rev. 8/17/2009-23 - - 24 -