GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK

Similar documents
INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

GA A22897 QUASI-OPTIC COMPONENTS IN OVERSIZED CORRUGATED WAVEGUIDE FOR MILLIMETER-WAVE TRANSMISSION SYSTEMS

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

GA A22577 AN ELM-RESILIENT RF ARC DETECTION SYSTEM FOR DIII D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

GA A22574 ADVANTAGES OF TRAVELING WAVE RESONANT ANTENNAS FOR FAST WAVE HEATING SYSTEMS

A REGULATED POWER SUPPLY FOR THE FILAMENTS OF A HIGH POWER GYROTRON

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK

GA A22583 FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIME-VARYING LOADING FOR DIII D

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

AN ELM=RESlLlENT RF ARC DETECTION SYSTEM FOR DIII-D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

Princeton Plasma Physics Laboratory

GA A27238 MEASUREMENT OF DEUTERIUM ION TOROIDAL ROTATION AND COMPARISON TO NEOCLASSICAL THEORY IN THE DIII-D TOKAMAK

Increased Stable Beta in DIII D by Suppression of a Neoclassical Tearing Mode Using Electron Cyclotron Current Drive and Active Feedback

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

GA A24691 STATUS OF THE ELECTRON CYCLOTRON HEATING SYSTEM ON DIII D

GA A26150 PROGRESS ON DESIGN AND TESTING OF CORRUGATED WAVEGUIDE COMPONENTS SUITABLE FOR ITER ECH AND CD TRANSMISSION LINES

SOL Reflectometer for Alcator C-Mod

GHz Radiometer. Technical Description and User Manual

Measurements of edge density profile modifications during IBW on TFTR

and GHz. ECE Radiometer. Technical Description and User Manual

Radio Frequency Current Drive for Small Aspect Ratio Tori

+o GENEML ATOMfCS. RF POWER DIAGNOSTICS AND CONTROL ON THE DIII-D, 4 MW MHz FAST WAVE CURRENT DRIVE SYSTEM (FWCD)

SUMMARY OF THE EXPERIMENTAL SESSION EC-10 WORKSHOP

Improved core transport triggered by off-axis ECRH switch-off on the HL-2A tokamak

Heterodyne Sweeping Radiometer

GA A25824 A NEW OVERCURRENT PROTECTION SYSTEM FOR THE DIII-D FIELD SHAPING COILS

System Upgrades to the DIII-D Facility

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

GA A23281 EXTENDING DIII D NEUTRAL BEAM MODULATED OPERATIONS WITH A CAMAC BASED TOTAL ON TIME INTERLOCK

GA A SOLID-STATE HIGH VOLTAGE MODULATOR WITH OUTPUT CONTROL UTILIZING SERIES-CONNECTED IGBTs by J.F. TOOKER and P. HUYNH

Development of local oscillator integrated antenna array for microwave imaging diagnostics

FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIMElVARYING LOADING FOR DIII-D

A NEW MULTI-POINT, MULTI-PULSE THOMSON SCATTERING SYSTEM FOR THE MST RFP

GA A FABRICATION OF A 35 GHz WAVEGUIDE TWT CIRCUIT USING RAPID PROTOTYPE TECHNIQUES by J.P. ANDERSON, R. OUEDRAOGO, and D.

Observation of Electron Bernstein Wave Heating in the RFP

Initial Data of Digital Correlation ECE with a Giga Hertz Sampling Digitizer

GA A23983 AN ADVANCED COLLABORATIVE ENVIRONMENT TO ENHANCE MAGNETIC FUSION RESEARCH

Upper limit on turbulent electron temperature fluctuations on Alcator C-Mod APS DPP Meeting Albuquerque 2003

Estimation of the Loss in the ECH Transmission Lines for ITER

Nanosecond, pulsed, frequency-modulated optical parametric oscillator

GA A22712 DIII D ICRF HIGH VOLTAGE POWER SUPPLY REGULATOR UPGRADE

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Development of Collective Thomson Scattering System Using the Gyrotrons of Sub-Tera Hz Region

GA A25780 STABILIZATION OF NEOCLASSICAL TEARING MODES IN TOKAMAKS BY RADIO FREQUENCY CURRENT DRIVE

Lower Hybrid. Ron Parker Alcator C-Mod PAC Meeting January January 2006 Alcator C-Mod PAC Meeting 1

Microwave Experiments on Prairie View Rotamak

Dust Measurements With The DIII-D Thomson system

GA A24463 CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII D TOKAMAK

Microwave Imaging in the Large Helical Device

DESCRIPTION OF THE OPERATION AND CALIBRATION OF THE MILLIMETER I/Q PHASE BRIDGE-INTERFEROMETER

Non-inductive Production of Extremely Overdense Spherical Tokamak Plasma by Electron Bernstein Wave Excited via O-X-B Method in LATE

D. F. Spencer R. Aryaeinejad E. L. Reber. October 2001

Levitated Dipole Experiment

Stimulated Emission from Semiconductor Microcavities

National Accelerator Laboratory

Advanced Density Profile Reflectometry; the State-of-the-Art and Measurement Prospects for ITER

Introduction to Radar Systems. The Radar Equation. MIT Lincoln Laboratory _P_1Y.ppt ODonnell

Abstract. G.D. Garstka 47 th APS-DPP Denver October 27, Pegasus Toroidal Experiment University of Wisconsin-Madison

UCRL-ID Broad-Band Characterization of the Complex Permittivity and Permeability of Materials. Carlos A. Avalle

Technical Readiness Level For Plasma Control

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

High Temporal Resolution Polarimetry on the MST Reversed Field Pinch

Up-conversion Time Microscope Demonstrates 103x Magnification of an Ultrafast Waveforms with 300 fs Resolution. C. V. Bennett B. H.

The Development of an Enhanced Strain Measurement Device to Support Testing of Radioactive Material Packages*

Final. NO.Report CRADA. Date: September 11, 1997

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

Detector And Front-End Electronics Of A Fissile Mass Flow Monitoring System

USER OPERATION AND MAINTENANCE MANUAL

Recent Results on Coupling Fast Waves to High Performance Plasmas on DIII-D

High Explosive Radio Telemetry System. Federal Manufacturing & Technologies. R. Johnson, FM&T; B. Mclaughlin, FM&T;

Accelerator and Fusion Research Division Lawrence Berkeley Laboratory University of California Berkeley, CA 94720

DEVELOPMENT OF MULTIVARIABLE CONTROL TECHNIQUES FOR USE WITH THE DIII D PLASMA CONTROL SYSTEM

Development of C-Mod FIR Polarimeter*

Advanced Tokamak Program and Lower Hybrid Experiment. Ron Parker MIT Plasma Science and Fusion Center

Detection of Targets in Noise and Pulse Compression Techniques

2. Achievement of reliable long pulse operation of 1 MW 170 GHz gyrotron

Fast Electron Temperature Diagnostic Based on Langmuir Probe Current Harmonic Detection on D-IIID

ICRF Mode Conversion Flow Drive Studies with Improved Wave Measurement by Phase Contrast Imaging

Introduction to Radar Systems. Clutter Rejection. MTI and Pulse Doppler Processing. MIT Lincoln Laboratory. Radar Course_1.ppt ODonnell

Development of the frequency scanning reflectometry for the registration of Alfvén wave resonances in the TCABR tokamak

Development of microwave imaging reflectometry at NIFS

Electron Bernstein Wave Heating and Emission in the TCV Tokamak

GA A23741 DATA MANAGEMENT, CODE DEPLOYMENT, AND SCIENTIFIC VISUALIZATION TO ENHANCE SCIENTIFIC DISCOVERY THROUGH ADVANCED COMPUTING

1997 Particle Accelerator Conference, Vancouver, B.C., Canada, May 12-16, 1997 BNL

The ACT External HEPA Push-Through Filter Assembly. A. A. Frigo, S. G. Wiedmeyer, D. E. Preuss, E. F. Bielick, and R. F. Malecha

ICRF Physics in KSTAR Steady State

3.10 Lower Hybrid Current Drive (LHCD) System

J.Shafii, J.N. Talmadge, R.J. Vernon, HSX team HSX Plasma Laboratory, University of Wisconsin-Madison T. S. Bigelow, ORNL K.M.

High Frequency Gyrotrons and Their Applications

QPR No SPONTANEOUS RADIOFREQUENCY EMISSION FROM HOT-ELECTRON PLASMAS XIII. Academic and Research Staff. Prof. A. Bers.

($E.. DISCLAIMER. b C

Observation of Cryogenic Hydrogen Pellet Ablation with a fast-frame camera system in the TJ-II stellarator

Operational progress of 170GHz 1MW ECH system in KSTAR

GA A26865 PEDESTAL TURBULENCE DYNAMICS IN ELMING AND ELM-FREE H-MODE PLASMAS

Transcription:

GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK by M.E. AUSTIN, and J. LOHR AUGUST 2002

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK by M.E. AUSTIN,* and J. LOHR This is a preprint of a paper to be presented at the Fourteenth Topical Conference on High Temperature Plasma Diagnostics, July 8 11, 2002, Madison, Wisconsin, and to be published in the Proceedings. *University of Texas, Austin, Texas. Work supported by the U.S. Department of Energy under Contract No. DE-AC03-99ER54463 and Grant No. DE-FG03-97ER54415 GENERAL ATOMICS PROJECT 30033 AUGUST 2002

ABSTRACT The electron cyclotron emission (ECE) heterodyne radiometer diagnostic on DIII-D has been upgraded with the addition of eight channels for a total of 40. The new, higher frequency channels allow measurements of electron temperature into the magnetic axis in discharges at maximum field, 2.15 T. The complete set now extends over the full usable range of second harmonic emission frequencies at 2.0 T covering radii from the outer edge inward to the location of third harmonic overlap on the high field side. Full coverage permits the measurement of heat pulses and magnetohydrodynamic (MHD) fluctuations on both sides of the magnetic axis. In addition, the symmetric measurements are used to fix the location of the magnetic axis in tokamak magnetic equilibrium reconstructions. Also, the new higher frequency channels have been used to determine central T e with good time resolution in low field, high density discharges using third harmonic ECE in the optically gray and optically thick regimes. GENERAL ATOMICS REPORT GA A24030 iii

I. INTRODUCTION Measurements of T e from optically thick second harmonic electron cyclotron emission is an established technique in magnetic confinement experiments. 1 Particularly methods employing heterodyne radiometers, due to their low noise and high frequency resolution, have produced detailed pictures of plasma phenomena. In this paper we describe an upgrade to the DIII-D radiometer and how it has expanded and improved the range of electron temperature measurements. GENERAL ATOMICS REPORT GA A24030 1

II. THE INSTRUMENT The DIII-D multichannel ECE heterodyne radiometer has been installed on the machine since 1995. The instrument was originally built for and installed on the Advanced Toroidal Facility at Oak Ridge National Laboratory. 2 After being transferred to the DIII-D site, it has been modified at various times for improved operation. In its present configuration it has 40 channels with frequency selection by multiplexers and a filterbank. A layout of the device is given in Fig. 1. The original front end had a WR-10 one-to-one waveguide coupler that split the power in the 82 114 GHz band into two mixers, each one feeding a bank of sixteen channels. This year a second 3 db coupler was added, after a WR-10 to WR-8 transition, to separate the power in the 98 130 GHz band and to feed an additional mixer in turn feeding 8 new channels. The three local oscillators are at 81, 96 and 112 GHz, giving mixer outputs of 2 18 GHz transmitted to each filterbank board, referred to as cards. In each card the IF power is amplified by a pair of 30 35 db amplifiers separated by an adjustable thumbwheel attenuator. The output of the second amplifier is split into 4 bands with a quadruplexer, which is in turn split 4-ways or 2-ways with 4- or 2-channel power splitters. Frequency selection is accomplished with 40 individual bandpass filters leading into 40 Schottky barrier diode detectors. The bandpass filters are 1 GHz wide at frequencies 2.5 17.5 at 1 GHz steps, for the first two cards of 16 channels, and 1 GHz wide at frequencies 3.5 17.5 at 2 GHz steps, for the last 8 channels. Pad attenuators of 1 10 db are used in front of the power splitters and detectors to level the outputs of the filterbank set to the same range of power. The detector signals are amplified by low-noise video amplifiers that have two outputs, a slow one limited by an RC filter to a bandwidth of 800 Hz, and a fast one limited by the video amplifier design to 25 khz. The two outputs are connected respectively to 40 channels of slow and fast CAMAC digitizers, sampling at 2 khz and 100 khz respectively. One of the improvements of the instrument was to increase the gain of the video amplifiers from 200 to 1000. Previously the output of the video amps had to be maintained below 200 mv to insure the Schottky detectors were running in the linear range below 15 mv output. The higher gain of 1000 allows full use of the 10 V/12-bit digitizer range, maximizing the volts/bit. The front end of the radiometer is fed by a low-loss transmission line of 15 m leading from a long-horn antenna viewing the DIII-D plasma along a horizontal chord at the tokamak midplane. The loss of the transmission line is about 4 db. At the end of the GENERAL ATOMICS REPORT GA A24030 3

ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK From transmission path 110 GHz notch filter WR-10 3dB coup. WR-10 to WR-8 WR-8 3dB coup. Noise tube Isolator High pass filter 81 GHz 96 GHz 112 GHz LO LO LO To Card I Veritech ampl. 2-18 GHz 35 db gain 0Ð50 db + 0Ð9 db Avantek ampl. 2-18 GHz 35 db gain Quadruplexer 2-6 GHz 6-10 GHz Card II 10-14 14-18 GHz GHz To Card III 4-way Power dividers Bandpass filters Schottky detectors to video amps FIG. 1 Schematic of the DIII-D radiometer. transmission line is a 110 GHz waveguide notch filter (Pacific Millimeter Waves Model N110). This bandpass filter provides at least 40 db of attenuation between 109.75 and 110.25 GHz and is used to block power from a bank of 110 GHz gyrotrons used for electron cyclotron heating (ECH) and current drive (ECCD) in DIII-D plasmas. Without the notch filter, stray and unabsorbed power at 110 GHz would swamp the mixers and make that portion of the discharge useless for radiometer temperature measurements, or worse, would burn out the diode and render the mixer inoperable. With the notch filter, the radiometer has been able to provide in ECH and ECCD experiments measurements of T e (r,t) which give the location and width of the EC power deposition in the plasma. Just after the notch filter at the radiometer front end is a WR-10 baseball switch that is used to switch the input from the transmission leg to an F-band noise tube. The noise tube is used to check and characterize the radiometer. Comparing the signals from the noise tube and a room temperature load, the noise temperature of the radiometer has been determined to be about 5 ev. This matches well with the range and type of T e measurements made on DIII-D. The instrument is not absolutely calibrated in stand-alone fashion. Instead it is calibrated by comparison with ECE spectra of plasma discharges from the DIII-D Michelson interferometer. 4 GENERAL ATOMICS REPORT GA A24030

To ensure calibration stability across multiple DIII-D discharges and during a discharge, steps have been taken to maintain fixed sensitivity of the radiometer. The sealed instrument cabinet is air conditioned to provide an ambient temperature between 21 25 C. Originally the local oscillators and IF amplifiers were outfitted with cooling fins to help maintain constant temperature. Subsequently the IF amplifiers were connected to thermal electric coolers (TECs) to maintain the temperature to within 0.5 C, since these amplifiers have temperature sensitive gain. The TEC elements are Melcor Model CP0.8-127-06L and the TEC controllers are Alpha Omega Instruments Model P37. Since adding the TECs, the calibration has been observed to remain stable for several weeks at a time. GENERAL ATOMICS REPORT GA A24030 5

III. ELECTRON TEMPERATURE MEASUREMENTS The additional channels of the radiometer have extended the operational range of the T e measurements in DIII-D plasmas. At full field, B T (0) = 2.15 T, the second harmonic ECE frequency corresponding to the central magnetic axis is 117 GHz for a plasma with a typical major radius of 1.75 m. This frequency was not covered by the original range of the diagnostic, 83.5 113.5 GHz. With the new channels covering 115.5 129.5 GHz, T e measurements at the magnetic axis and farther inboard are now possible. Figure 2 shows a T e profile for a discharge at 2.10 T and details the improved coverage of the new channels. 4 DIII-D T e Profile Shot 110309, 1500 ms B T = 2.1 T Thomson ECE New ECE 3 T e (kev) 2 1 0-1.0-0.5 0.0 0.5 1.0 ρ FIG. 2. DIII-D electron temperature profile for a discharge at 2.10 T showing new ECE radiometer channels covering the high field side of the magnetic axis. The curve is a spline fit to the data. One of the common uses of ECE data on DIII-D is the determination of the magnetic axis location as an aid to the magnetic equilibrium reconstruction process. The flux contours in a DIII-D discharge are calculated by the EFIT code and one measure of the accuracy of the reconstructed equilibrium is the overlap of the low field side and high field side ECE T e values near the center. Previously the Michelson interferometer data was the only means to look at this for fields of 2.0 T and higher. With the new high frequency channels it is now possible to use the radiometer data for this purpose. The added radiometer channels have also opened up new possibilities at lower magnetic fields on DIII-D. Many experiments are done at fields of 1.60 1.00 T for low q and high GENERAL ATOMICS REPORT GA A24030 7

ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK beta investigations. Also, for long pulse length experiments greater than 5 s, the B-field set point must be lower for constant magnetic field. The radiometer frequencies move far inboard at these fields and the higher frequencies fall into the regime of third-harmonic overlap. For example, at 1.60 T the central second harmonic frequency is about 86 GHz and frequencies above 98 GHz have both a second harmonic and a third harmonic resonance in the plasma. At this field the right-hand cutoff of the central frequency occurs at an electron density of n e = 4.6x10 19 m -3, a value very often exceeded in H-mode discharges. Under these conditions it is not possible to measure central T e with second harmonic ECE. However, with the new ECE channels it is possible to measure emission from central third harmonic frequencies corresponding to fields at or less than 1.60 T. In addition, under many conditions the third harmonic ECE is optically thick or nearly so. T e measurements from third harmonic ECE have been demonstrated on DIII-D and other plasma devices. 3,4 Using the method outlined in Ref. [3] central T e has been determined in a discharge at 1.60 T where the emission at the central second harmonic frequency is cutoff. Using Thomson scattering central density and edge T e data the radiation temperature signal at 129.5 GHz is adjusted for optical depth and absorption to give central T e as a function of time. The result is shown in Fig. 3. The T e values obtained are in good agreement with the central Thomson scattering measurements. For a given tokamak B-field the cutoff density for third harmonic ECE is a factor of 3 higher than for the second harmonic so this technique makes possible T e measurements over a much broader range of operating conditions. 3.0 T e (kev) 2.5 2.0 1.5 T e Thomson T e ECE 2nd T e ECE 3rd 1.0 Cutoff 0.5 0.0 0 1000 2000 Time (ms) 3000 4000 FIG. 3. Central T e vs time in a DIII-D discharge with B T =1.60 T. The long-dashed curve is from second harmonic emission at 90.5 GHz shown going into cutoff at 1200 ms. The solid curve is from central third harmonic emission at 129.5 GHz, corrected for optical depth. The short-dashed curve with markers is the core measurement from Thomson scattering. 8 GENERAL ATOMICS REPORT GA A24030

IV. SUMMARY Several improvements have been incorporated into the DIII-D heterodyne radiometer. Higher gain video amplifiers have increased the sensitivity of the diagnostic while ensuring linear output of the detectors. Calibration stability has been enhanced with temperature control of the IF amplifiers using TECs. Additional channels at higher frequency permit second harmonic T e measurements inboard of the magnetic axis at full field. Moreover, the added channels provide third harmonic T e measurements at reduced field, in high density discharges, with good time resolution. GENERAL ATOMICS REPORT GA A24030 9

V. REFERENCES 1 A.E. Costley, in Proc. of the Course on Diagnostics for Fusion Reactor Conditions, Vol. 1, Varenna (1982) p. 129. 2 G.L. Bell, R.F. Gandy, J.B. Wilgen, and D.A. Rasmussen, Rev. Sci. Instrum. 59, 1614 (1988). 3 M.E. Austin, R.F. Ellis, R.A. James, and T.C. Luce, Phys. Plasmas 3, 3725 (1996). 4 G.L. Bell, R.F. Gandy, and J.B. Wilgen, Nucl. Fusion 33, 875 (1993). GENERAL ATOMICS REPORT GA A24030 11

ACKNOWLEDGMENT This work was supported by the U.S. Department of Energy under Contract Nos. DE- AC03-99ER54463 and Grant No. DE-FG03-97ER54415. GENERAL ATOMICS REPORT GA A24030 13