Appendix A: Specifications

Similar documents
Appendix A: Specifications

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

NI 6143 Specifications

NI DAQPad -6020E Family Specifications

NI PXI-4461 Specifications

2620 Modular Measurement and Control System

BENNING. CM7 Electrical Tester. Service Information

NI PXI-2557 Specifications

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

NI PXI/PXIe-2529 Specifications

NI PXI-2555 Specifications

NI PXIe-5601 Specifications

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

NI PXI-2532 Specifications

R&S ZVT Vector Network Analyzer Specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

NI 6731/6733 Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

R&S ZNC Vector Network Analyzer Specifications

Specifications. PCI Bus. Analog Input Input Characteristics

NI 6023E/6024E/6025E Family Specifications

Vector Network Analyzers ZVB

Keysight Technologies N9320B RF Spectrum Analyzer

z8801 Local Oscillator PXI

NI PXIe-5630 Specifications

Agilent N9320B RF Spectrum Analyzer

Chapter 6 Specifications

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI/PCI-5411/5431 Specifications

NI PXI-2530 Specifications

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

R&S ZNB Vector Network Analyzer Specifications

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

ARCO 400. Technical Data

R&S ZV-Z5x Calibration Units Specifications

NI 6013/6014 Family Specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Appendix G - Specifications. G Specifications. Appendix G - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave. Frequency Accuracy

NI PXI/PCI-5411/5431 Specifications

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Appendix D - Specifications. D Specifications. Appendix D - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

High precision measurement system for current and voltage IHC-A/B-RM01/03

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

R&S ZVT Vector Network Analyzer Specifications

SCXI MHz Quad 8x1 50 Ω Multiplexer

NI PXIe-5663 Specifications

NI PXI/PXIe-2532 Specifications

Voltage Transient Emission Test

NI SCXI Specifications

R&S ZV-Z5x Calibration Units Specifications

Fluke 5820A Oscilloscope Calibrator Specifications

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Arbitrary/Function Waveform Generators 4075B Series

Specifications for the NI PXI/PCI-6552/6551

R&S SMB100N SIGNAL GENERATOR

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

SWT 3000 Teleprotection technical data siemens.com

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Fluke 83V and 87V Digital Multimeters

1587/1577 Insulation Multimeters

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

z475 Remote DC Power Supply Preliminary

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

z47524 PXI Quad SPDT RF Changeover Switch Module

Output Voltage* (nom.)(adjustable)

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI PXI/PXIe-2527 Specifications

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

NI 6040E Family Specifications

5520A. Multi-Product Calibrator. Extended Specifications 2005

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

8588A Reference Multimeter

PXIe Contents SPECIFICATIONS. 250 khz to 20 GHz RF Analog Signal Generator

5500A. Multi-Product Calibrator. Extended Specifications 2005

WaveStation Function/Arbitrary Waveform Generators

SCC-FV01 Frequency Input Module

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

NI PXI/PXIe-2540 Specifications

Voltage Adjustment. Load Regulation

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

NI 6238/6239 Specifications

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Audio/video, Information and Communication Technology Equipment - Part 1:

RADIATED IMMUNITY TEST SYSTEM 6 GHz

TE60 60W Single Output External Power Test & Measurement/Industrial Series

CB Scheme UL508 UL ATEX II3G

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Appendix A: Specifications This section provides a complete description of the video measurement set specifications. Refer to the Performance Conditions for a description of the required temperature range and other pertinent operating conditions. Terms Used in Specifications Characteristic A characteristic refers to a property of the product. Performance Requirement [REQ] Performance Requirements define characteristics that are essential to the intended application of the product, usually in limit form. Reference Information [RI] Reference Information explains the performance requirements or stipulates conditions under which the performance requirements are effective. Reference information is not considered to be a statement of guaranteed performance. Specification A specification is a document or a section of a document that lists and describes characteristics and performance requirements of a product. A specification also may contain reference information. Typical Typical refers to instrument performance that can be expected but is not guaranteed. Performance Conditions The Performance Requirements listed in the Electrical Specifications apply over an ambient temperature range of 0 C to +50 C. The rated accuracies are valid over the entire 0 C to 50 C range and become typical for temperatures from 10 C to 0 C. Test equipment used to verify Performance Requirements must be calibrated and working within the specified limits. All specifications (with the exception of Signal-to-Noise Ratio Measurement Accuracy) apply for Signal-to-Noise Ratio 52 db (weighted). Averaging (AVG) is enabled for all specifications. VM100 & VM101 User Manual A 1

Electrical Specifications Table A 1: Input signal requirements VIDEO INPUT Maximum Operating Voltage REQ: 1.8 V to +2.2 V Absolute Maximum Input Voltage REQ: 8.5 V to +8.5 V Minimum Operating Voltage REQ: 1 Vp-p video signal DC Input Impedance REQ: 20 K Typically operates with a 1 Vp-p input, +1 db or 6 db DC coupling Return Loss REQ: >40 db to 6 MHz DC coupling Table A 2: Input signal requirements EXT REF Absolute Maximum Input Voltage REQ: 8.5 V to +8.5 V Minimum Operating Voltage REQ: 1 Vp-p video signal DC Input Impedance REQ: 20 K Return Loss REQ: >40 db to 6 MHz Video INPUT / EXT REF Crosstalk REQ: >70 db to 6 MHz Typically operates with a 1 Vp-p input, +1 db or 6 db Loop-through Isolation >70 db (typical) A 2 VM100 & VM101 User Manual

Table A 3: Measurement accuracy 1 Differential Phase REQ: <1.0 Differential Gain REQ: <2.0% Typically <0.5 from 20 C to 30 C with test signal generator source Chrominance-to-Luminance Gain REQ: <2% Chrominance-to-Luminance Delay REQ: <20 ns Typically <1% from 20 C to 30 C for nominal 300 mv chrominance amplitude Typically <1% from 20 C to 30 C with test signal generator source REQ: <10 ns from 20 C to 30 C with test signal generator source. Frequency Response REQ: <0.2 db Typically <5 ns from 20 C to 30 C with test signal generator source Typically <0.1 db (1 %) from 20 C to 30 C with test signal generator source VM100: 50 khz to 4.2 MHz VM101: 50 khz to 5.8 MHz 2T K-Factor REQ: 2 % Typically <0.5 % from 20 C to 30 C with test signal generator source 1 All tests are performed with AVG enabled. Processing time for each measurement is a function of the signal-to-noise ratio. VM100 & VM101 User Manual A 3

Table A 3: Measurement accuracy (cont.) 1 Hum 2 REQ: ±1.0% for hum 4.0% ±2.0% for hum >4.0% and <15.0% Signal-to-Noise Ratio (Weighted or Flat) REQ: Typically ±0.5% for hum 4.0% ±1 db, 28 db to <45 db ±2 db, 45 db to <60 db ±3 db, 60 db to 67 db (WGT) VM100: Noise is weighted with EIA RS-250-B 5 MHz weighted noise filter. (Tektronix part number 015-0215-00 equivalent.) VM101: Noise is weighted with CCIR 567 weighted noise filter Group Delay REQ: <20 ns Sync Amplitude 2 REQ: <1.0% Burst Amplitude REQ: <1.0% Bar Amplitude REQ: <1.0% Luminance Nonlinearity REQ: <1.0% 50 khz to 4.8 MHz, within the bandwidth of the signal under test 1 All tests are performed with AVG enabled. Processing time for each measurement is a function of the signal-to-noise ratio. 2 The hum and sync amplitude measurements are inaccurate in the presence of Sound In Sync (SIS) signals. A 4 VM100 & VM101 User Manual

Table A 4: Output Zero Carrier Reference Pulse Output Can drive demodulator ZCRP trigger of TTL type (Tektronix TDM5, DS1200, 1450) or 1.5 V p-p, 75 type (Tektronix 1340, 1350) Table A 5: AC power source Mains Voltage Range REQ: 90-250 VAC 50/60 Hz 0.7 A Power Consumption REQ: 30 W maximum Environmental Characteristics Table A 6: Environmental characteristics Altitude (see page A 6 for safety-related information) REQ: Operating: to 15,000 f (4572 m) Non-operating: to 50,000 f (15,240 m) Maximum operating temperature decreases 1 C per 1000 f (305 m) Humidity REQ: To 95% relative humidity at or below +50 C Operating Temperature REQ: 0 C to + 50 C (32 F to 122 F) Electrical specifications are guaranteed when the instrument is operated in this temperature range VM100 & VM101 User Manual A 5

Table A 6: Environmental characteristics (cont.) Package Drop REQ: Meets Tektronix 062-2858-00, Rev. B Random Vibration (Operating and Non-Operating) REQ: Meets Tektronix Class III (062-2858-00, Rev. B) Shock (Operating) REQ: Meets Tektronix Class III (062-2858-00, Rev. B) Three drops on each face of 50 g, 11 ms duration, half-sine pulse shape for a total of 18 drops Storage Temperature REQ: 40 C to + 75 C ( 40 F to +167 F) Loose Load Vibration (Repetitive Shock) REQ: Meets Tektronix 062-2858-00, Rev. B (page 51, section 17.7.4) Vehicle Vibration REQ: Meets Tektronix 062-2858-00, Rev. B Safety Standards and Certification Table A 7: Certifications and compliances Altitude (Maximum Operating) Operating: to 6,500 f (2,000 m) See page A 5 for additional information Certifications US Nationally Recognized Testing Laboratory Listing Canadian Certification ANSI/ISA S82 Safety Standard for Electrical and Electronic Test, Measuring, Controlling, and Related Equipment CAN/CSA C22.2 No.1010.1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use A 6 VM100 & VM101 User Manual

Table A 7: Certifications and compliances (cont.) Certifications (continued) European Union Compliance Additional Compliance Low Voltage Directive 73/23/EEC, Amended by 93/68/EEC UL3111-1 Standard for Electrical Measuring and Test Equipment IEC 1010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use EC Declaration of Conformity Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility and Low Voltage Directive 73/23/ECC for Product Safety. Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities: EMC Directive 89/336/EEC: 1 EN 50081-1 Emissions: EN 55022 Class B Radiated and Conducted Emissions EN 50082-1 Immunity: IEC 801-2 Electrostatic Discharge Immunity IEC 801-3 RF Electromagnetic Field Immunity IEC 801-4 Electrical Fast Transient/Burst Immunity Low Voltage Directive 73/23/EEC: EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use 1 Using high quality shielded cables. Equipment Type FCC Compliance Test and Measuring Emissions comply with FCC Code of Federal Regulations 47, Part 15, Subpart B, Class A Limits VM100 & VM101 User Manual A 7

Table A 7: Certifications and compliances (cont.) Overvoltage Overvoltage II (as defined in IEC 1010-1, Annex J) Pollution Degree Pollution Degree 2 (as defined in IEC 1010-1); rated for indoor use only Safety Class Class I (as defined in IEC 1010-1, Annex H) Temperature (Operating) +5 C to +50 C (+41 F to 122 F) Physical Characteristics Table A 8: Physical characteristics Dimensions Stand-Alone Instrument Weight Packaged Weight (for domestic shipment) Height: 1.71 in (4.34 cm) Nominal Width: 8.1 in (20.6 cm) Nominal Depth: 17.2 in (43.7 cm) Nominal 4.00 lbs (1.81 kg) Nominal 7.12 lbs (3.23 kg) Nominal Remote Control Port Table A 9: Remote control port RS-232 Serial Port Connector: Nine-pin DCE female Baud Rate: 300, 600, 1200, 2400, 4800, 9600, or 19.2K A 8 VM100 & VM101 User Manual