mos-500 SPECTROPOLARIMETER Circular Dichroism Spectrometer Everything you expect from a spectropolarimeter

Similar documents
Joliot Type Spectrometer. photosynthesis system JTS-10. A LED pump-probe spectrometer

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

lis Product Catalog Modular spectrophotometers for research and advanced teaching laboratories Making brilliant breakthroughs happen

T92+ UV-VIS SPECTROPHOTOMETER

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Tunable KiloArc. Tunable Broadband Light Source.

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Spectro p photomete p r V-700 series

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

CHAPTER 7. Components of Optical Instruments

SP-8001 UV/Visible Spectrophotometer

The FTNIR Myths... Misinformation or Truth

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

1/8 m GRATING MONOCHROMATOR

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

SCCH 4: 211: 2015 SCCH

Croma Enterprise Cromtech India

CHEM Course Outline (Part 14) Absorption Spectroscopy update 2011 For an html version of 2005 notes, click here

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

instruments Analytical Instruments for Science

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Lambda 1050 / 950 UV/Vis/NIR

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Technical Overview. Applied Photophysics Limited Unit 21 Mole Business Park Leatherhead KT22 7AG United Kingdom

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Visible & UV/Vis Spectrophotometers

University of Wisconsin Chemistry 524 Spectroscopic Components *

The Olis Hummingbird Series

Ultraviolet Visible Infrared Instrumentation

Content Spectrophotometers

Basic Components of Spectroscopic. Instrumentation

Chemistry Instrumental Analysis Lecture 7. Chem 4631

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

TriVista. Universal Raman Solution

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Fast Laser Raman Microscope RAMAN

Components of Optical Instruments

Cary 50 UV-Vis UV-VIS. SARIN sas di Leo Temin & C. VARIAN, INC. SPECTROPHOTOMETERS

Lab Junior Educational UV-VIS Spectrometer

Spark Spectral Sensor Offers Advantages

Improving the Collection Efficiency of Raman Scattering

Fast Laser Raman Microscope RAMAN

Measuring optical filters

Compact High Intensity Light Source

A Novel Multipass Optical System Oleg Matveev University of Florida, Department of Chemistry, Gainesville, Fl

FS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements

Confocal Microscopy. Kristin Jensen

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

FS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Synergy NEO HTS Multi-Mode Microplate Reader

NIR SPECTROSCOPY Instruments

Table 8 Overview light sources

CONTENTS Product Accessory Software V /02 V-5100/UV /04 UV-5100B 05/06

MS260i 1/4 M IMAGING SPECTROGRAPHS

SpectraMax i3x Multi-Mode Detection Platform. Explore a wealth of applications in one future-ready system

LAMBDA 800 UV/VIS and 900 UV/VIS/NIR Spectrophotometer Systems

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Experimental Analysis of Luminescence in Printed Materials

Microscope-Spectrometer

Research Grade Xenon Arc Lamp Sources LH-Series 75 W - 300W

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

AvaLight-DHc Full-range Compact Light Source

THEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS...

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Spotlight 150 and 200 FT-IR Microscopy Systems

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

UV / VIS Spectrophotometer

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

V-730Bio UV-Vis Double Beam Spectrophotometer for Bio-Analytical applications

Oriel Cornerstone 130 1/8 m Monochromator

Thermo Scientific SPECTRONIC 200 Education

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

VWR SPECTROPHOTOMETERS

Maya2000 Pro Spectrometer

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

JETI Specbos Instruments

Development and Applications of a Sample Compartment FTIR Microscope

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

UV-Vis-NIR Spectrophotometer Quick Start Guide

SolidSpec-3700 SolidSpec-3700DUV

Spectrometers. Spectroscopy HOLMARC UV-VIS-IR HOLMARC OPTO-MECHATRONICS PVT.LTD HOLMARC INSTRUMENTS CONTENTS. Spectrometer Goniometer RE-02

Application Note (A11)

Oriel MS260i TM 1/4 m Imaging Spectrograph

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

SpectraPro 2150 Monochromators and Spectrographs

Wavelength Meter Sensitive and compact wavemeter with a large spectral range for high speed measurements of pulsed and continuous lasers.

Single Photon! Sensitivity

Transcription:

mos-5 SPECTROPOLARIMETER Circular Dichroism Spectrometer Everything you expect from a spectropolarimeter Speed and Sensitivity Stability Modularity Low running cost user-friendliness

innovation and Performance general specifications 163-95 nm, and nm (white light) (up to 1,25 nm optional) Dual light source ( Xe and XeHg) ±.1 nm wavelength accuracy over full wavelength range Peltier temperature control optional Unsurpassed baseline stability Fast and sensitive Standard detection modes: CD/Absorbance/HV, Fluorescence, FD/CD, Fluorescence anisotropy and polarization, LD, HPLC-CD Optional modes: NIR-CD, ORD, DR-CD, Stopped-flow and titration, Emission fluorescence MOS-5 uses an innovative and patented three stage wavelength selection system to bypass the limitation of traditional prism-based monochromators. The design delivers outstanding performance in wavelength range, sensitivity, precision, speed, and modularity. Operating cost is reduced as well, since the MOS-5 requires purging of optics only when working below 195 nm. A standard dual lamp box adds to the convenience of the system, and an optional tungsten lamp enhances IR performance. Thanks to its modular design the MOS-5 is much more than a CD spectrophotometer. Multiple detection modes and a wide range of accessories from stopped-flow to ORD are available to allow you to adapt the system to your research. MOS-5 Spectropolarimeter

MilliDegree 4 3 2 1-1 -2 2 22 24 26 28 3 32 34 MilliDegree 3 25 2 15 1 5-5 -1-15 18 19 2 21 22 23 24 25.6% Camphor sulfonic acid.2s/pt,.25 nm steps, and 1 nm bandwidth CD spectra collected with.5s/pt,.25 nm steps, and 1 nm bandwidth lysozyme (green), cytochrome c (red) and myoglobine (blue) Unsurpassed stability The combination of super quiet light source with ultra stable optics and electronics make the MOS-5 the most stable spectropolarimeter on the market by a full order of magnitude. It is ideal for measurements and titrations that take hours to complete. Low noise The optical components and design were carefully chosen for the best quality, longevity, and efficiency. The optical path is optimized so the maximum amount of light reaches the detector from far UV to NIR. The photomultiplier detector was chosen to offer the highest sensitivity from far UV to 95 nm. The wide range detector means the system can be used for no compromise fluorescence measurements, making MOS-5 a more versatile and cost effective instrument. Optional PMTs can be installed for specific applications if needed, without upgrading hardware. Multiple scanning modes Scanning speed can be set by the user, or automatically controlled in software to optimize the quality of spectral data. Under software control the scanning speed is reduced for wavelengths where the level of light is low. The user can display raw data or apply post acquisition processing. Scans can be easily synchronized with temperature or titration steps through Biokine software. Double light source The MOS-5 includes a Xenon/ Xenon (Hg) double light source. The xenon lamp is preferred for UV-Vis scans and XeHg for single wavelength applications. The user can select either source in seconds without handling or realigning the lamp. This makes the system especially valuable in a multi-user lab. The MOS-5 can accommodate lamps from 75 W to 2 W, and tungsten lamps are available for different application needs.

Unique technology 1 1 +/- nm,1,1 1 3 5 7 9 11 Wavelength accuracy profile for MOS-5 prism based spectrometers Tunable chromatic light source Coupled to a double grating monochromator The MOS-5 combines a patented chromatic illumination system with a new grating design to provide wavelength range, diffraction efficiency, and accuracy. The patented chromatic illumination system provides the initial selection of the wavelength. Like a prism monochromator it uses the variation of the refractive index of quartz. This is followed by the latest design double grating monochromator to give constant and optimal resolution, and precision at all wavelengths. The chromatic illumination of the double monochromator also reduces the energy received by the monochromator and extend lifetime of the optics. Monochromators are confined so level of stray light is minimum, allowing high performance spectra in the far-uv. The slit mechanism is software controlled, and bandwidth can be selected freely from to 16 nm. The MOS-5 also includes a software controlled shutter for photosensitive samples. Grating vs Prism Conventional CD spectrometers based on double prism monochromators use prisms to polarize light. Prisms provide good wavelength resolution in UV region, but in the visible and IR region however, wavelength precision can be reduced by a factor of 2. Precision is also reduced when compared to gratings in the same wavelength ranges. This makes it difficult to run well resolved spectra using small slits. In addition, prism monochromators are not ideal for rapid kinetics studies even in UV region. Indeed for kinetics user wants to get as much light as possible and often wishes to open slits widely which is not always possible with prism monochromators. The MOS-5 combination of a tunable chromatic light source with gratings offers the best performance over the full UV, visible and NIR range. Instead of choosing between prism and grating monochromator the MOS-5 combines the best of both worlds MOS-5 Spectropolarimeter

Low running cost - save more than 5, e a year Calculation is based on a daily use at a 3l/ min N 2 flushing of optics (recommended by other manufacturers) and cost of one N 2 bottle in 212. Instrument being used above 2 nm only. 12 1 PMT high voltage (V) 8 6 4 2 175 18 185 19 195 2 25 21 HV spectra with and without N 2 flushing (no effect above 195 nm) No need for N 2 flushing above 195 nm Classical CD instrument manufacturers have made nitrogen flushing a requirement for CD measurements. The main reason is the need to remove oxygen and to reduce its light absorption in the far-uv range. This is important for wavelength shorter than 195 nm, but N 2 flushing is useless from 195 nm to NIR. Another reason is the need to protect refective coatings from ozone generated by UV reaction with oxygen in the lamp compartment. The MOS-5 design dramatically reduces the need for N 2 flushing. It is designed without focusing mirrors in the lamp compartment, so there is no risk to the optics. The gas purge space is divided into three areas: the light source, the optical bench and the sample compartment. The instrument is sealed so the N 2 purge can be stopped in the lamp housing and optical bench after 2 minutes of operation, while keeping outstanding performances in the far UV range. Automatic variable focalization The sample compartment is large and accessible to accommodate many options. The focal point is automatically adjusted to accommodate the detection mode and accessory installed. The light beam can be parallel, or be focused on the cell, or on the detector to offer the best signal to noise for each experimental condition. The detector position can also be as close as possible to the cell. These automatic adjustments are unique and a key to delivering the best performance in the most demanding applications.

More than just a CD Spectrometer Anisotropy.21.18.15.12.9.6.3 -.3 Anisotropy,125,12,115,11,15 24 25 26 27 28 29 3 Lysozyme fluorescence anisotropy spectrum 1 2 3 4 5 6 7 Time (s) BSA /Phloxine reaction followed in anisotropy mode Polarization and Fluorescence Anisotropy The MOS-5 includes a unique fluorescence anisotropy measurement mode. The EMFA method uses fast modulation of the polarized excitation light and synchronous detection of the fluorescence signal to achieve a very sensitive and fast measurement of sample anisotropy. Fluorescence anisotropy is a useful technique in a wide range of application: binding, denaturation, aggregation and crystallization, or any reaction inducing a total or a partial change of flexibility of the molecule holding the chromophore. Data can be displayed in anisotropy units, or as the two polarized signals. Total Fluorescence is also measured simultaneously. Excitation Modulated Fluorescence Anisotropy EMFA method was developed and patented by Bio-logic in 1999. Refer to World Intellectual Property Organization website for details. Fluorescence and FD-CD The standard photomultiplier tube covers a wavelength range from 16 nm to 95 nm. It is ideal for fluorescence application. The PMT housing can be easily relocated at 9 to the beam for fluorescence or FD-CD measurements. The PMT housing accepts 1 inch diameter filters to select emission light. When doing Fluorescence Detected Circular Dichroism (FD-CD), the photo elastic modulator alternatively generates left and right circularly polarized light. The difference between the two polarization signals is measured with the PMT installed at 9 to the beam. If the user wants to simultaneously record CD and fluorescence signals, or dual fluorescence, second PMT is required. MOS-5 Spectropolarimeter

LD (delta A) -,2 -,4 -,6 -,8 -,1 -,12 -,14 -,16 2 22 24 26 28 3 28 µg/ml DNA spectra using 1 second sampling Linear dichroism Linear dichroism is the difference in absorption of parallel and perpendicular linearly polarized light. These two polarizations are generated by using half wave retardation with a photo elastic modulator. LD gives information on the orientation of bio-macromolecule. The MOS-5 includes hardware and software to measure LD signals in steady state and kinetics mode. To collect LD spectra the user can use commercial flow through cells or an optional couette cell to orient the sample in the cell. A multi-channel approach The MOS-5 was designed to provide a multi-modal approach. CD, absorbance and HV can be recorded simultaneously, and the user can add temperature and fluorescence signals with additional accessories. When temperature is controlled through a Peltier element, dynamic multimode spectroscopy measurements are possible. The MOS-5 is by far the most modular and highest performing system on the market, with outstanding specifications in every detection modes. HPLC-CD The MOS-5 can be coupled to HPLC instruments using a commercial flow cell fitted into the sample compartment. Biokine software can be triggered from the HPLC to record the chromatogram. The CD signal can also be fed back into the HPLC for data comparison and analysis. The HPLC-CD signal can be recorded over the full wavelength range of the MOS-5.

TEMPERATURE CONTROL 55 15 5 1 45 5 Degree ( C) 4 35 3 MilliDegree -5-1 25-15 2 2 4 6 8 1 12 14 Time (s) -2 2 21 22 23 24 Precision of sample temperature recording without overshoot (1 C, 5 C and 1 C temperature steps) Thermal denaturation of lysozyme (from 3 C to 85 C in a 1 cm cuvette) Single cell Peltier Temperature controller The MOS-5 can be equipped with an optional Peltier temperature controller for precise and rapid temperature control of the cell. The temperature of the Peltier element is regulated according to the real temperature of the cell for smooth control without overshoot. The measured temperature corresponds exactly to the target temperature without any gradient due to the distance between the Peltier and the cell. Temperature ramping is easily programmable from Biokine software. At each temperature step a CD spectrum can be measured automatically. For single wavelength thermal stability studies it is also possible to directly measure the CD signal versus temperature to determine thermodynamic properties of a protein (Tm, ΔCp, ΔS). Multi-cell Peltier Temperature controller The MOS-5 can be fitted with a 4-cell Peltier temperature controller for precise temperature regulation of up to four samples. Each cell has its own magnetic stirrer. The operating range is -4 C to 15 C using a circulating chiller unit. The Multi-cell temperature controller is fully controlled from Biokine software, including cell position in the beam, temperature ramping, or single temperature scans. Specifications Full software control.1 C precision Magnetic stirring standard Temperature range: -1 C to 11 C Temperature of the cell and Peltier can both be measured Easy programming MOS-5 Spectropolarimeter

Volt 55 5 45 4 35 3 25 2 15 8 9 1 11 12 Comparative HV spectra of Xenon and Tungsten lamp in NIR region (xenon peaks are clearly observed) NIR upgrade The NIR option extends wavelength range to 1,25 nm. It includes a photomultiplier tube optimized for NIR range, and a tungsten lamp. Conventional CD spectrometers based on prism monochromators are optimized to separate light in the far UV. However, the longer the wavelength, the worse the wavelength resolution, and it is impossible to work with small slits and to detect narrow CD peaks. Bio-Logic s new wavelength focusing system with grating monochromators gives the user the same wavelength resolution over the full wavelength range. In the NIR region the MOS-5 offers 2 times better accuracy compared to a prism based system. A tungsten lamp adds to the better performance, since tungsten bulbs do not have sharp intensity peaks which makes lamp regulation difficult. INTUITIVE SOFTWARE The MOS-5 and all accessories are fully controlled from Biokine software. Acquisition parameters are selected from a single window for easy experiment design. Data files can be saved in different formats for internal analysis, or easily exported to secondary structure analysis software for example.

options MilliDegree 3 2 1-1 -2-3 22 24 26 28 3 32 34 36 MilliDegree -1-2 -3-4 22 24 26 28 3 32 34 36 CD and ORD spectra of camphor sulfonic acid showing positive cotton effects DR-CD spectra of camphor sulfonic acid ORD accessory ORD (Optical Rotary Dispersion) and CD are closely related techniques. ORD is used to study the chirality of a biomolecule by passing a beam of linearly polarized light through the sample. If the sample is chiral, then the light will be rotated as a function of wavelength. From this rotation, the user can determine the left- or right-handed chirality of the molecule. No physical rotation of the polarizer is required during acquisition so an ORD spectrum can be collected over tens of seconds with a outstanding sensitivity. The ORD accessory is mounted on a standard photomultiplier tube. It includes one polarizer and a special PMT holder equipped with a micrometric screw, allowing fine adjustment of the polarizer position before measurements. Electronics in the MOS-5 do not need to be upgraded when adding the ORD accessory. The ORD accessory can also be used for steady state measurements. Specifications 21-9 nm (1,2 nm when combined with IR accessory) ±1 degrees Detection limit:.1 mdeg DR-CD: CD-powder Measuring CD spectra on powder has long been desired as a way to eliminate solvent contribution. A Pellet technique can be used, but the quality of results is very dependent upon quality of sample preparation. Bio-Logic has designed a Diffuse Reflectance CD accessory based on an integration sphere using an internal coating specially chosen for its high reflectance. The DR-CD accessory can be installed in seconds in the sample compartment. The powder holder is designed to minimize linear dichroism artifacts, and is installed directly into the integration sphere. High quality spectra can be obtained in minutes on solid samples like powders and other samples like leaves. Specifications 24-9 nm (1,2 nm when combined with IR accessory) MOS-5 Spectropolarimeter

MilliDegree 18 16 14 12 1 8 6 4 2 Circular dichroism.2.4.6.8 1 Time (s) 3.8 3.6 3.4 3.2 Volt 3 Stopped-flow All stopped-flow mixing systems manufactured by Bio-logic can be attached to the MOS-5 in minutes. The latest generation SFM-2/3/4 mixers deliver outstanding kinetics specification. Our SFM models are based on independent stepping motor technology and Berger Ball mixers which provide the best kinetics performance on the market. A series of experiments such as concentration dependence studies can be done quickly and automatically, without changing syringes or doing manual dilution. This saves time for the user. Stopped-flow kinetics can be measured in all detection modes. A dead time of.2 ms can be obtained in all detection modes with the optional micro-cuvette. Nitrogen flushing of optics is not necessary when the MOS-5 is operated in stopped-flow configuration. To get an optimum signal to noise ratio in kinetics mode it could be essential to use a XeHg lamp (222 nm alpha helix, Trp fluorescence ). The dual light source of MOS-5 allows switching from Xe to XeHg lamp in seconds without handling or realigning the bulb. It is the easiest to use lamp system available. Specifications.2 ms dead time (with optional microcuvette) Mixing ratio fully controllable form 1:1 to 1:1 Single, double, and triple mixing Automatic concentration dependence studies Choice of 1 cuvettes Low sample volume requirement For absorbance, fluorescence, CD, anisotropy, LD, chemiluminescence, 9 light scattering Fluorescence Absorbance Linear dichroism AU LD (delta A) 2.8 2.6 2.4.2.4.6.8 1 1.2 1.4 Time (s).12.1.8.6.4.2.9.8.7.6.5.4.3.2.1.2.4.6.8.1.12.14.16 Time (s).1.2.3.4.5.6 Time (s)

SPECIFICATIONS specifications Light source super quiet 15 W Xe and Xe (Hg) air-cooled, tungsten available in option (air-cooled) Monochromator tunable chromatic light source coupled to double grating (patented) Wavelength range 163-95 nm (standard), 163-125 nm (with optional detector) Nitrogen gas purge only for scans < 195 nm ( no risk of damaging optics), high efficiency N 2 purge optimized for light source, optical bench and sample compartment Wavelength accuracy ±.1 nm from 163 to 1,25 nm Wavelength precision ±.5 nm from 163 to 1,25 nm Bandwidth to 16 nm on full wavelength range Stray light < 2 ppm at 2 nm CD resolution.1 mdeg CD range ±7,5 mdeg Baseline stability ±.7 mdeg/hour Scanning speed.1 ms to 2 s per data point Data interval.1 nm to 1 nm in scanning mode, 1 µs to 2 s in kinetics mode Scanning modes step scan, adaptive scan, temperature scan, kinetics (slow or using stopped-flow) Rms noise.15 mdeg at 185 nm using 1 nm BW, 16 s sampling.1 mdeg at 2 nm using 1 nm BW, 16 s sampling.7 mdeg at 5 nm using 1 nm BW, 16 s sampling Standard detection modes CD, Absorbance, HV (standard all simultaneous) Fluorescence, FD/CD, Fluorescence anisotropy, HPLC-CD, LD Optional detection mode NIR-CD, ORD, DR-CD UV measurement accuracy ±.1 AU (built-in filters to remove second order) Shutter built-in, software control External input/output 4 in, 3 out (for external connections) PC interface Windows 7, 32 or 64 bits Other options titrator (concentration and ph), emission monochromator Dimensions 139 x 32 x 39 (cm, W x D x H) Weight 35 kg Specifications are subject to change Corporate Office Bio-Logic, SAS 1, rue de l Europe 3864 CLAIX - France Tel.: +33 476 98 68 31 Fax: +33 476 98 69 9 www.bio-logic.info USA Customers Bio-Logic USA, LLC P.O.Box 39 Knoxville TN 3793 - USA Tel.: +1 865 769 38 Fax: +1 865 769 381 www.bio-logic.us Brochure released on july 212 - - 1248 w w w. b i o - l o g i c. i n f o