CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Similar documents
REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY

LIFT. Please give your shopfitters not only this information sheet but also the floor plan showing the exact position of the unit.

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Site plan. Water tapping. Water Main. Property boundary. Guru Gully Road. Portico. Scale example:

BUILDING PLAN REVIEW REQUIREMENTS

A. This Section includes plumbing fixtures and related components.

Trade of Plumbing. Module 1: Thermal Process and Mild Steel Pipework Unit 5: Drawing Phase 2

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION PLUMBING FIXTURES

Residential Construction Checklist Single and Two Family Construction

76'-0" 10'-5 7/8" 10'-2" 3 7/8 15'-10 1/8" 5'-0" 42'-1 7/8" DINING. IS x83 KITCHEN. 36x80 CLAYTON WAKARUSA

Training Manual The Installation of Siphonic Pipework

Role of BIM. in Plumbing System -K Chandrakanth and M Vinay Kumar. Abstract. 3 Dimension. Introduction: Collaborative Design:

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Autodesk Revit MEP Learning Essentials Training Course Outline

2250 S LOCUST APARTMENT IMPROVEMENTS EXPENSES

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Students will learn to correctly prepare, assemble, and solvent weld ABS piping.

ADDENDUM #2 September 12, 2018

Design Deliverables. Summary. A. Expectations for Design Deliverables:

ADDENDUM NO. 2. The Bid Opening has not changed it remains December 8, 2016 AT 1:30 P.M.

ERRATA AND REVISIONS to the CANADIAN PLUMBING CODE

CKBD Peakes Bath Scoresheet

City of Thousand Oaks

Project Affordable Housing Design Rubric

Kitchen and Bath Design Planner

Level 2 Media Studies, 2015

TO WHOM IT MAY CONCERN:

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

Plan Review and Standards

Cabinet Planning Guide

Drafting: Orthographic and Isometric Drawings

PLUMBER APPRENTICESHIP PROGRAM

LEVEL PLUMBING TASK MANUAL

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 11/02/2012 BUILDING SURVEY DATE

INDEX OF SHEETS FLAMING GORGE RANGER DISTRICT OFFICE ADDITION REGION 4 INTERMOUNTAIN REGION ASHLEY NATIONAL FOREST DRAWING SHEET INDEX

technician Unit Title / Code: Sewage, drainage and vent installations / NS/AT/PL / Unit 9 Unit Type (e.g. major, minor, elective): Unit Level:

Addendum to Description of Services for Building and Planning, Digital Design. The Association of of Consulting Engineers

BUILDING DEPARTMENT CURRENT

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

CITY OF COLUMBIA DEPARTMENT OF UTILITIES AND ENGINEERING WASTEWATER COMPLIANCE FATS, OILS, AND GREASE REGISTRATION APPLICATION

LATTIMORE SHOWER SET INSTALLATION

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Installation and Maintenance Instructions

Fitting C.O. Adapter

NZQA registered unit standard version 2 Page 1 of 5. Demonstrate knowledge of bitumen handbar sprayers and operations

CIVIL TECHNOLOGY GUIDELINES FOR PRACTICAL ASSESSMENT TASKS. These guidelines consist of 27 pages and an annexure.

1907 Grayson Street North Charleston, SC TMS: FRANKLIN DESIGN

NZQA Expiring unit standard version 3 Page 1 of 8. Operate bitumen handbar sprayer equipment, and handspray bitumen for chipseal surfacing

Level 3 Physics, 2015

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION (Autonomous) (ISO/IEC certified)

Effective Date: January Rev. 3/21/2018- Void After: January Product: Ceramic Plumbing Fixtures File No. 8317

EPIC Academy High School

NOTICE OF INCORPORATION United States Legal Document

VILLAGE OF ALGONQUIN COMMUNITY DEVELOPMENT 2200 Harnish Drive Algonquin, IL Phone (847) Fax (847)

Accessible Toilet Stalls 6/18/03 1

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - FIXTURES AND TRIM

Autodesk Revit MEP Plumbing: Mystery Solved

SaniCalc. Help and Operating Instructions. Overview

Residential Room Addition / Remodel Submittal Requirement Checklist

SECTION MECHANICAL IDENTIFICATION

Strengthened Technical-Vocational Education Program COURSE DESIGN

Rheem Room Sealed Kit - Installation Instructions. Installation must be carried out by a licenced plumber

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

ADDENDUM THREE SPECIFICATIONS. Vincennes University Renovations of the Curtis G. Shake Learning Resources Center

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd.

HYDRO-TOWER INSTALLATION INSTRUCTIONS

ONE TOUCH PERFECT TEMPERATURE. Introducing the digital shower range with wireless control from Mira Showers.

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607

U of I Facilities Standards Updates for 2017

SEBASTIAN TUB FAUCET INSTALLATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Time: 3 hours. 3 Section B Candidates should attempt questions 8, 9 and 10 and either question 11 or question 12. 4

CIVIL TECHNOLOGY. 9. For the purpose of this paper, the size of a brick should be taken as 220 mm 110 mm 75 mm.

Wendell Smith Elementary School

Project Affordable Housing Design Rubric

Emmett Louis Till Math and Science Academy 6543 S Champlain Ave Chicago, IL 60637

How to measure guide

New Multi-Family Buildings & Additions Plan Intake Submittal Checklist. Project Name: Site Address:

Ellen Mitchell Elementary School 2233 W Ohio St Chicago, IL 60612

Basic Plan Set Requirements

Philip Rogers Elementary School

SECTION MECHANICAL IDENTIFICATION

ARCHITECTURAL SYMBOLS

Richard J Oglesby Elementary School

CALLAS THERMOSTATIC SHOWER SET

Josefa Ortiz De Dominguez Elementary School 3000 S Lawndale Ave Chicago, IL 60623

2012 IMC Performing Commercial Mechanical Inspections

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

Non-Residential and Multi-Family Plan Check Submittal Requirements

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

A/E REVIEW CHECKLIST HVAC

Lodgement checklist: water heater (solar or heat pump)

Hall of Waters List of Historic Drawings

Grease Interceptor Design Checklist

Hiram H Belding Elementary School 4257 N Tripp Ave Chicago, IL 60641

3. DESIGN SPECIFICATIONS

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

Transcription:

Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE hours Check that the Candidate Code Number on your admission slip is the same as the number on the label at the top of this page. Do not start writing until you are told to do so by the Supervisor. Total marks for this examination: 100. The pass mark for this examination is 60 marks. Write your answers and draw your sketches in this booklet. If you need more paper, use the blank pages at the back of this booklet. Clearly write the question number if any of these pages are used. All working in calculations must be shown. Candidates are permitted to use the following in this examination: Drawing instruments, approved calculators The following are NOT permitted in the examination room: Any publications, Acts, Regulations, Codes of Practice, or Standards Check that this booklet has all of 17 pages in the correct order and that none of these pages is blank. YOU MUST HAND THIS BOOKLET TO THE SUPERVISOR AT THE END OF THE EXAMINATION Plumbers, Gasfitters and Drainlayers Board, 2008. All rights reserved. No part of this publication may be reproduced by any means without the prior permission of the Plumbers, Gasfitters and Drainlayers Board.

QUESTION 1 (a) State FIVE categories of people who are permitted to do sanitary plumbing under the Plumbers Gasfitters and Drainlayers Act. 1 2 3 4 5 (5 marks) (b) The New Zealand Building Code and the compliance document G12 Water Supplies contain a set of four objectives in relation to the installation of water supplies. State these FOUR objectives. 1 2 3 4 (4 marks) Total 9 marks Craftsman Plumbing 9195, June 2008 1

QUESTION 2 The diagram opposite shows a cross-sectional view of a high rise building. Water supply systems within the building are to be designed. On the diagram, draw and label all pipework and associated components. Include a ground floor storage water tank to supply all water to the building separate systems of potable and non-potable water from staged (break) tanks staged (break) tanks that supply four floors a pneumatic booster to supply fire hose reels on each floor backflow prevention devices. Note: Show only the termination points on each floor and not the connections to individual fittings and fixtures. Total 14 marks Craftsman Plumbing 9195, June 2008 2

QUESTION 2 (cont d) Craftsman Plumbing 9195, June 2008 3

QUESTION 3 List SIX aspects that should be considered in the installation of a pump for supplying water to ensure trouble-free operation. Assume that the pump is the correct one for the job and that there is an adequate supply of water from below the level of the pump inlet. 1 2 3 4 5 6 Total 6 marks Craftsman Plumbing 9195, June 2008 4

Question 4 The starter drawing below shows an indirect combined flow and return potable domestic hot water supply system and a heating system. On the diagram, draw and label all the pipework and valves necessary in the design of the systems. Include drain points, and show the position of the circulating pumps on the secondary hot water supply circuit and the heating circuit. Do not show tempering or radiator control valves. Draw off points Radiator Radiator Radiator Total 16 marks Craftsman Plumbing 9195, June 2008 5

QUESTION 5 (a) Name the valve shown in the diagram below. (1 mark) Craftsman Plumbing 9195, June 2008 6

QUESTION 5 (cont d) (b) Explain how the valve in (a) operates under each of the following conditions. (i) Normal operation. (ii) No flow. (iii) Back-siphonage. (iv) Backpressure. (8 marks) Craftsman Plumbing 9195, June 2008 7

QUESTION 5 (cont d) (c) The valve shown in (a) is to be installed within the confines of a building envelope. State SIX factors that must be considered when deciding where to locate the valve. 1 2 3 4 5 6 (3 marks) Total 12 marks Craftsman Plumbing 9195, June 2008 8

Question 6 The diagram below shows a cross-sectional elevation of a three storey building. Rooms 1, 2 and 3 may be subject to accidental overflow or spillage from sanitary fittings. Rooms 4, 5, 6 and 7 are subject to floor washing on a regular basis. Floor wastes are to be installed in all rooms in compliance with the New Zealand Building Code clause G13/AS1. Complete the cross-sectional elevation by drawing in all the floor waste pipe-work and termination points, and show the minimum pipe sizes required. Foul water stack and vent Relief vent Room 1 Room 4 Room 5 FW FW FW Room 2 Room 6 FW FW Room 3 Room 7 FW FW Gully Trap Total 8 marks G.L. Craftsman Plumbing 9195, June 2008 9

Question 7 A three storey building requires hot water to be delivered for personal hygiene while maintaining the circulating temperature at 75 C. On the starter drawing opposite and using a ruler, draw a mains pressure re-circulating hot water system for the building. All pipe work is to remain within the pipe ducts except for that in the plant room (cylinders). Include the layout of the cold water supply pipe work and associated valving the backflow valves for containment on the water supply inlet hot water flow and return pipe work the position of the circulating pump and associated valving isolating valves tempering valves. Show only the cold water supply pipework necessary for the installation of the tempering valves and hot water cylinders. No other cold water pipework is to be shown. Only the pipework and valves specified above are to be shown. Total 12 marks Craftsman Plumbing 9195, June 2008 10

Question 7 (cont d) Outlets Second floor Pipe duct Outlets Pipe duct First floor Pipe duct Outlets Outlet Outlet Ground floor Return Inlet Inlet Return Inlet Inlet Plant room Supply inlet Craftsman Plumbing 9195, June 2008 11

Question 8 The starter drawing opposite shows the layout of sanitary fittings within a three storey building. On the diagram, and using the tables below, draw and size all foul water and ventilation pipework for the foul water system for the building. All pipework sizes and gradients are to be the minimum to comply with New Zealand Building Code G13/AS1. No air admittance valves are to be used. All foul water pipework is to terminate at the three points shown. Table 2: Fixture Discharge Pipe Sizes and Discharge Units Sanitary fixture or appliance Discharge units Minimum trap and discharge pipe diameter (mm) Basin 1 32 Bath (with or without overhead shower) 4 40 Urinal (bowl type) 1 32 Kitchen sink 3 40 Water closet pan 4 80 Table 4: Diameter (mm) Discharge Unit Loading for Stacks and Graded Discharge Pipes Maximum discharge from any one floor Vertical stack Graded discharge pipes Minimum gradient 1:20 1:30 1:40 1:50 1:60 32 1 1 1 40 2 6 6 5 4 50 5 15 15 10 8 65 6 18 51 29 21 80 13 40 65 39 27 20 16 100 65 195 376 248 182 142 115 Table 6: Vent Pipe Sizes For fixture vent pipes Diameter of fixture discharge pipe (mm) Minimum diameter of fixture vent pipe (mm) 32 32 40 32 50 40 65 40 80 40 100 40 For branch vent, branch drain vent, relief vent and discharge stack vent pipes Maximum discharge units connected to the discharge pipe Minimum diameter of open vent pipe (mm) Up to 15 40 16 to 65 50 Craftsman Plumbing 9195, June 2008 12

Question 8 (cont d) Service duct WC G.L. 3.800m Not to scale Total 20 marks Craftsman Plumbing 9195, June 2008 13

QUESTION 9 The following diagram shows a plan view of a warehouse roof with an internal gutter. The roof has a pitch of 22.5. Fall Pitch 22.5º 15.500m Fall 22.500m Craftsman Plumbing 9195, June 2008 14

QUESTION 9 (cont d) (a) Using Figure 16 on the page opposite, find the minimum cross-sectional area of the internal gutter. Base your answer on a rainfall intensity of 100mm/hr. (2 marks) (b) Using table 5 below, find the size of round down pipe required for the gutter in (a). Table 5: Downpipe Sizes for Given Roof Pitch and Area Downpipe size (mm) Roof pitch (minimum internal sizes) 0-25º 25-35º 35-45º 45-55º Plan area of roof served by the downpipe (m 2 ) 63 mm diameter 60 50 40 35 74 mm diameter 85 70 60 50 100 mm diameter 155 130 110 90 150 mm diameter 350 290 250 200 65 x 50 rectangular 60 50 40 35 100 x 50 rectangular 100 80 70 60 75 x 75 rectangular 110 90 80 65 100 x 75 rectangular 150 120 105 90 (1 mark) Total 3 marks Craftsman Plumbing 9195, June 2008 15

This page is available for additional working or answers Question number Craftsman Plumbing 9195, June 2008 16

This page is available for additional working or answers Question number Craftsman Plumbing 9195, June 2008 17

For Examiner s use only Question number Marks Marks 1 2 3 4 5 6 7 8 9 Total