PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

Similar documents
PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

PRODUCT DATA. Sound Intensity Calibrator Type 4297

WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada

APPLICATION NOTE 3560/7702. Introduction

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

PRODUCT DATA. Pocket Front-end Type 3560 L PULSE Lite Software Types 7781, 7782, 7783

EFFECT OF STIMULUS SPEED ERROR ON MEASURED ROOM ACOUSTIC PARAMETERS

Mr. Wolfgang Metzen was trained as a mechanical

NON-SELLABLE PRODUCT DATA

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

PRODUCT DATA. Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

PRODUCT DATA. PULSE Vibration Check System for Aircraft Engines Type 3641 including PULSE Standard Configuration 3560-B-T57

Technical Documentation

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Impulse response. Frequency response

Getting Started with the LabVIEW DSP Module

Measuring procedures for the environmental parameters: Acoustic comfort

Validation of lateral fraction results in room acoustic measurements

PRODUCT DATA. NEXUS Conditioning Amplifiers for Very High Input Types 2692-C and 2692-D

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

KickStart Instrument Control Software Datasheet

Product Data. Brüel & Kjær B. Artificial Mastoid Type 4930

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Measurement Statistics, Histograms and Trend Plot Analysis Modes

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

Influence of artificial mouth s directivity in determining Speech Transmission Index

N9051A Pulse Measurement Software

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

PRODUCT DATA. Applications. Uses

PRODUCT DATA. PULSE Reflex Angle Domain Analysis Type Uses and Features

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

Real time spectrum analyser sound level meters

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

WHITEPAPER. Advantages of Christie Vive Audio planar ribbon and line array technologies for cinema sound

Transfer Function (TRF)

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Differential Probes P6248 P6247 P6246 Datasheet

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

IMPULSE RESPONSE MEASUREMENT WITH SINE SWEEPS AND AMPLITUDE MODULATION SCHEMES. Q. Meng, D. Sen, S. Wang and L. Hayes

Advanced Test Equipment Rentals ATEC (2832)

Essential Capabilities of EMI Receivers. Application Note

QuickSpecs. VIVE Pro VR System with Advantage+ Service Pack. Overview

Keysight E5063A ENA Series Network Analyzer

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

PRODUCT DATA. Type channel Human Vibration Front-end Type 1700

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

EFFECT OF ARTIFICIAL MOUTH SIZE ON SPEECH TRANSMISSION INDEX. Ken Stewart and Densil Cabrera

Arbitrary/Function Generator AFG1000 Series Datasheet

P R O D U C T D A T A

29th TONMEISTERTAGUNG VDT INTERNATIONAL CONVENTION, November 2016

Agilent VQT Portable Analyzer J1981B Data Sheet

Keysight Technologies USB Preamplifiers

PRODUCT DATA. Hydrophones Types 8103, 8104, 8105 and 8106

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Digitally controlled Active Noise Reduction with integrated Speech Communication

Technique for the Derivation of Wide Band Room Impulse Response

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

Agilent U8903A Audio Analyzer

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

Arbitrary Function Generator AFG1022 Datasheet

Keysight Technologies Phase Noise X-Series Measurement Application

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Introduction. Part 1. Introduction...2

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

30 A AC/DC Current Probe TCP0030A Datasheet

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

Low Capacitance Probes Minimize Impact on Circuit Operation

TriMode Probe Family P7700 Series TriMode Probes

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

SIA Software Company, Inc.

NI sbrio-9632/9642 Verification Procedure

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Introduction. Part 1. Introduction...2

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Transcription:

PRODUCT DATA DIRAC Room Acoustics Software Type 7841 MEASURING ROOM ACOUSTICS Brüel & Kjær is the sole worldwide distributor of DIRAC, an acoustics measurement software tool developed by Acoustics Engineering. Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands DIRAC PC software is used for measuring a wide range of room acoustical parameters. Based on the measurement and analysis of impulse responses, DIRAC supports a variety of measurement configurations. For accurate measurements according to the ISO 3382 standard, you can use the internally generated MLS or sweep signals through a loudspeaker sound source. Survey measurements are easily carried out using a small impulsive sound source, such as a blank pistol or even a balloon. Speech measurements can be carried out in compliance with the IEC 6026 16 standard, for male and female voices, through an artificial mouth-directional loudspeaker sound source or through direct injection into a sound system, taking into account the impact of background noise. DIRAC is a valuable tool not only for field and laboratory acoustics engineers, but also for researchers and educational institutions. 7841

USES FEATURES Measurement of the acoustical properties of an enclosure Measurement of the speech intelligibility of a sound system Characterisation of room acoustics before and after modification Comparison of acoustical quality of different rooms Modelling room acoustics using measurements taken in a scale model Research and education on acoustics Troubleshooting room acoustics Measures reverberation, spaciousness, speech intelligibility and many other parameters Dual input Conforms to ISO 3382 (room acoustics) and IEC 60268 16 (speech intelligibility) standards User-friendly and fast Impulse Response editing Supports many different types of sources and receivers Reverse filtering technique enables accurate short reverberation time measurement Multiple time and/or frequency views of the impulse response Statistics calculation (mean, standard deviation, min-max) Supports scale model measurements Soundcard test and validation Auto Measure enables a single person to quickly measure large rooms Export to ODEON enables convenient comparison of measurement and modelling results Multiple groups of measurements can be displayed in a single graph or table About DIRAC Basic Principle Fig. 1 Basic principle of impulse response measurement Sound Source Processing Unit Receiver To investigate the acoustical properties of a room, you can clap your hands and listen to the response of the room. Although it may not be easy to describe accurately what you hear, this method gives you an impression of whether music would sound pleasant or speech would be intelligible in this room. DIRAC uses this principle as the basis for measuring the acoustical properties of a system through impulse responses. 020055 2

Impulse Responses The mathematical impulse or Dirac delta function, named after the theoretical physicist Paul A.M. Dirac, is infinitely short and has unit energy. A system s response to such an impulse contains all the information on the system, and as such, is convenient for analysis and storage. DIRAC measures and saves acoustical impulse responses, and calculates acoustical parameters from impulse responses. Other Excitation Signals Through deconvolution, DIRAC can also calculate the impulse response using other excitation signals, thereby enabling the use of loudspeaker sound sources. These sources feature a better directivity, frequency spectrum and reproducibility than impulsive sound sources, but would have difficulties in reproducing high-power impulsive signals. Examples of suitable non-impulsive excitation signals are the MLS (Maximum Length Sequence) signal, the sweep or swept sine (sine with frequency increasing linearly or exponentially with time), white noise and pink noise. Required Hardware The minimum hardware required to use DIRAC is a PC with a soundcard, an impulsive sound source, such as a blank pistol, and a microphone connected to the actual soundcard line input. Each of these three components can be varied, depending on the type of measurement to be performed. Typical soundcard functions, used by DIRAC, are a line input, a line output and gain controls. In case of a notebook or laptop PC, soundcard functions are integrated or otherwise can be attached as a PCMCIA or USB device. DIRAC determines the soundcard properties by means of a soundcard calibration in a loopback configuration: the soundcard output is connected to the input. During calibration, redundant functions are disabled, gain controls are calibrated and the frequency response is equalised. In this way, the software becomes independent of the soundcard and the input and output gain can be easily controlled from within DIRAC. As mentioned before, instead of an impulsive sound source, you can use a loudspeaker sound source. To measure room acoustical parameters in compliance with the ISO 3382 standard, an omni-directional sound source should be used. To simulate a real talker in speech intelligibility measurements according to the IEC 60268 16 standard, you can use a mouth simulator or a small loudspeaker. To measure the speech intelligibility through a sound reinforcement system, you can use the loudspeakers of that system. In any case, the excitation signal can be obtained from DIRAC through the soundcard output or, under certain conditions, from an external generator. At high sound pressure levels, the signal from the microphone may be sufficient to perform impulse response measurements, when fed directly into the soundcard line input. However, additional amplification is usually required. In this instance, a sound level meter with a line output could be used. For a list of recommended types, please refer to the Ordering Information on the back cover. If only one channel is used, it should be channel 1 or in audio terms, the left channel. For jack plugs used with most soundcards, this corresponds to the tip of the plug. Fig. 2 Using one or two soundcard input channels and a sound level meter or a microphone with amplifier Line output Line input Channel 1 Channel 1 020056 Line output Line input Channel 1 Channel 2 Channel 1 020057 3

Measuring Acoustical Parameters Measuring Methods DIRAC supports several impulse response measuring methods, which are related to the sound source. Which method is used, depends on the situation. Fig. 3 Internal MLS or Sweep: DIRAC produces MLS or swept sine excitation signal at the line output Fig. 4 External MLS, lin- Sweep or e-sweep: DIRAC produces a copy of the DIRAC excitation signal Fig. 5 External Noise: excitation by broadband signal, such as noise or music Fig. 6 External Impulse: exciation by impulsive signal, such as from blank pistol or paper bag The Internal MLS, lin-sweep, or e-sweep methods are accurate, but require a connection between the PC and a loudspeaker sound source or some other system. 020058 The External MLS, lin-sweep, or e-sweep methods do not require a connection between the PC and a sound source or other system, which is convenient for long distances. The external sound source must, however, meet certain requirements for accurate results. 020060 The External Noise method allows the use of any broadband continuous signal source, such as noise or music, but the method is less accurate, and only one measurement channel is available. 020062 The External Impulse method allows the use of small lightweight sound sources, such as balloons or blank pistols, but is less accurate. 020064 020059 020061 020063 020065 Acoustical Parameters DIRAC can calculate a set of acoustical parameters, from 1 or 2 impulse responses, depending on the receiver type used during the measurement. You can select from 6 different types (see Table1). 4

Table1 Relation between receiver type selected and parameters to be calculated Parameter Single Omnidirectional Switchable Omni-bidirectional Dual Omnidirectional Omnidirectional + Bidirectional Head Simulator Intensity Probe INR G EDT, T 10, T 20, T 30 T S, C 80, D 50 LF LFC IACC ST early, ST late, ST total STI (male & female) RASTI Fig. 7 Left: measuring reverberation times and energy ratios for survey Right: measuring IACC Practical Examples Fig. 7 shows examples of practical measurement setups. 020066 020067 Calibrations DIRAC supports 4 different kinds of calibration. Soundcard calibration (as mentioned earlier) enables optimal operation and user control of the soundcard from within DIRAC. It will also equalise the frequency response of the soundcard. System calibration enables the measurement of the sound strength G, and improves the accuracy of LF and LFC measurements. Speech level calibration supplemented by Input level calibration enables you to measure the speech intelligibility ifor various background noise conditions. Results Impulse Response Views DIRAC can display an impulse response in several ways. The reflectogram highlights the energy peaks, the decay curve shows the energy progression, the Schroeder curve displays the backwards integrated energy progression. The Energy-Time Curve shows the average energy progression and the Decay Curve displays the backwards integrated energy progression. In a time domain view you can select any part of the impulse response, and then edit, listen to or view details of the selected interval. 5

Fig. 8 Time domain views: original impulse response and energy-time curve from a single channel measurement Fig. 9 Frequency domain views: linear FFTs and smoothed logarithmic FFT spectrum from dual channel measurements Several frequency spectrum views allow convenient analysis in the frequency domain (see also Parameter Graphs paragraph). Fig. 10 Energy Time Frequency plots: waterfall plot and spectrogram Energy Time Frequency Plots To give a clear view of the spectral progress of an impulse response, DIRAC features several types of energy-time-frequency plots, such as the CSD (Cumulative Spectral Decay) and the spectrogram. Parameter Graphs Acoustical parameters, derived from the impulse responses, can be displayed in table format or graphically. Measurements can be grouped, and over each group of files you can calculate averages, minima, maxima, and standard deviations of the measured acoustical parameters. The results can be viewed on screen, or copied and pasted into a report. 6

Fig. 11 Left: The ISO 3382 table displays parameters measured in compliance with the standard Right: Magnitude spectrum Fig. 12 Left: D 50 average and standard deviation over four receiver positions Right: D 50 average over 4 receiver positions, for two different source positions Fig. 13 D 50 table showing average and standard deviation over 4 measurement positions, for 2 source position groups and 2 channels per measurement. For each frequency, the number of usable results is given Other Applications Fig. 14 Measurement in a scale model of a reverberation chamber, using a miniature omnidirectional sound source Scale Model Measurement To predict the acoustics of, for instance, a concert hall that is being designed but not yet realised, you can measure impulse responses in a scaled down model of the hall. After DIRAC has converted the scale model impulse responses to real world impulse responses, you can analyse them in the usual way. 7

Local representatives and service organisations worldwide Specifications DIRAC Room Acoustics Software Type 7841 STANDARDS Conforms with the following: IEC 1260 Octave and 1/3-octave Bands Class 0 ISO 3382 Acoustics Measurement of the reverberation time of rooms with reference to other acoustical parameters IEC 60268 16 Sound system equipment Part 16: Objective rating of speech intelligibility by speech transmission index OPERATION The software is a true 32-bit Windows program, operated using buttons and/or menus and shortcut keys HELP AND USER LANGUAGE Concise context-sensitive help is available throughout the program in English MEASURING METHODS Internal MLS, Internal lin-sweep, Internal e-sweep, External MLS, External lin-sweep, External e-sweep, External Noise, External Impulse. Measurements can be executed automatically MLS and Sweep Lengths: 0.34 21.8 s Pre-average: 1 999 times Filters: None, Pink + Blue, Female, Male, RASTI RECEIVER TYPES Single omni-directional, dual omni-directional, switched omni-bidirectional, omni-directional and bi-directional, artificial head, sound intensity probe FREQUENCY RANGE 10 octave bands from 31.5 Hz to 16 khz 30 1/3-octave bands from 20 Hz to 20 khz CALCULATED PARAMETERS Early Decay Time, EDT Reverberation Time, T 10 Reverberation Time, T 20 Reverberation Time, T 30 Strength (Level rel. 10 m free-field), G Centre Time, T S Clarity, C 80 Definition (Deutlichkeit), D 50 Early Lateral Energy Fraction, LF Early Lateral Energy Fraction, LFC Inter Aural Cross-correlation Coefficient, IACC Speech Transmission Index, STI Room Acoustics STI, RASTI STI for TELecommunication systems, STITEL Percentage Loss of Consonants, % ALC Early Support, ST early Late Support, ST late Total Support, ST total Impulse Response to Noise Ratio, INR Signal to Noise Ratio, SNR Relative Strength, G rel Magnitude Spectrum All parameters can be viewed in table and/or graph format. POST-PROCESSING All parameters can be viewed in table and/or graph format. Measurements can be grouped, and over each group the average, standard deviation, minimum and maximum can be calculated. the calculated results of multiple groups can be displayed in a single graph or table CALIBRATION Soundcard Calibration: For optimum mixer settings, maximally flat loopback frequency characteristics and gain step registration System Calibration: In diffuse or direct sound field, for measurement of Strength G Speech Level Calibration: Using built-in Male, Female or RASTI speech filters, for direct speech intelligibility measurements in noisy environments Input Level Calibration: For speech intelligibility measurements that have to be evaluated for various background noise conditions REVERBERATION TIME RANGE 1/1-octave bands: 0.002 100 s (1 khz) 1/3-octave bands: 0.006 100 s (1 khz) Minimum reverberation times inversely proportional to frequency SCALE MODEL Scaling Factors: Adjustable between 0.01 and 100 Frequency Range: 40 khz (1/3-octave band), at 96 khz sample frequency IMPULSE RESPONSE VIEWS AND PLOTS Impulse, Response, Energy-Time Curve, Decay Curve, linear frequency spectrum, logarithmic frequency spectrum, CSD plot, waterfall plot, spectrogram PRINT AND EXPORT Graphs and tables can be exported via the clipboard, or printed. All results can be printed or exported in ASCII (text) format for further processing in other programs. All results can be exported in ODEON format COMPUTER SYSTEM REQUIREMENTS Operating Systems: Windows 95, 98, ME, 2000, XP, Windows NT RAM: Minimum 32 MB, recommended 128 MB Free Disk Space: Minimum 120 MB Auxiliary Hardware: CD-ROM drive, SVGA graphics display/ adaptor, mouse or other pointing device Sound Card: 2 channels, full duplex, 22.05, 44.1, 48 or 96 khz sample rate Ordering Information Type 7841 including: Software on CD ROM HASP Key Loopback Cable AO 0593 OPTIONAL ACCESSORIES ZE 0770 A PCMCIA Sound Card Type 2238 Integrating Sound Level Meter Type 2239 Integrating Sound Level Meter Type 2260 Precision Sound Level Analyzer AO 0585 3 m Cable from 2238/2239 AC Output to Soundcard input (3.5 mm jack plug) AO 0586 3 m Cable from 2260 Aux. output to Soundcard input (3.5 mm jack plug) AO 0592 10 m Cable to extend AO 0585 or AO 0586 (3.5 mm jack plug female/male) AO 0592 V Extension Cable, 3.5 mm jack plug, customer specified length 7841 MS1 Software Maintenance and Upgrade Agreement Note: For sound sources, please see Product Data: Sound Sources for Building Acoustics (BP 1689) TRADEMARKS Microsoft, Windows NT and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries Brüel & Kjær reserves the right to change specifications and accessories without notice. BP 1974 12 03/09 Rosendahls Bogtrykkeri HEADQUARTERS: DK-2850 Nærum Denmark Telephone: +45 45800500 Fax: +45 45801405 www.bksv.com info@bksv.com Australia (+61) 2 9889-8888 Austria (+43)1 865 74 00 Brazil (+55)11 5188-8166 Canada (+1) 514 695-8225 China (+86) 10 680 29906 Czech Republic (+420) 2 6702 1100 Finland (+358)9-755 950 France (+33)1 69 90 71 00 Germany (+49)421 17 87 0 Hong Kong (+852) 2548 7486 Hungary (+36)1 215 83 05 Ireland (+353) 1 807 4083 Italy (+39) 0257 68061 Japan (+81) 3 3779 8671 Republic of Korea (+82)2 3473 0605 Netherlands (+31)318 55 9290 Norway (+47) 66 77 11 55 Poland (+48) 22 816 75 56 Portugal (+351) 21 47 11 4 53 Singapore (+65) 377 4512 Slovak Republic (+421) 25 443 0701 Spain (+34) 91 659 0820 Sweden (+46) 8 449 8600 Switzerland (+41) 1 880 7035 Taiwan (+886)22 713 9303 United Kingdom (+44) 14 38 739 000 USA (+1) 800 332 2040