FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

Similar documents
FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

FMR Description

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

ELSEMA 1-Channel 433MHz Receiver with 16A Relay Output- GLR

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

MCR91508POS 8 Channel receiver with 8 positive output switching

The combination of FFH and MCR technology brings you a very sophisticated receiver yet easy to use.

ELSEMA. GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output

MCR91501R 1-Channel, 915MHz Receiver with Frequency Hopping

FMR MHz Receiver with Two Relay Outputs

ELSEMA 1,2,3,4,8 -Channel 433MHz,25mWatt Transmitter

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

MD12-2 Metal Loop Detector

Transmitters & Receivers

Operating Distance An operating distance (in conjunction with our GLR27 series receivers) of 350 metres is possible.

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

Operating Instructions

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

VIPER Remote Control Systems

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

MINIATURE AM / FM DECODER MODULES

MCT91501, MCT91502, MCT91503, MCT MHz Hand Held Transmitter with Fast Frequency Hopping

200, 201 Series Radio Telemetry Transmitters

Modular Radio Telemetry System

Installation Notes. SCR Single Channel

PRO Professional Radio Control Series Applications

Remote Switching. Remote Gates. Paging.

Modular Radio Telemetry System

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

Remote Switching. Remote Gates. Paging.

HORNET Remote Control Systems

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

PCK43302, PCK MHz Penta series Keyring Remotes with Frequency Hopping

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

P700WLS IoProx Receiver

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

RCDC2 Radio Controlled Device Controller- 2 channel

OVEN INDUSTRIES, INC. Model 5C7-362

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

SABRETrap Control. Description

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Flexible Receiver. Installation Notes. Product Part No (304MHz)

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

IRRIGATION 810-3R RECEIVER GUIDE

Four channel wireless switch controller SK108

RF Remote Control Unit SEAV

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

FM Radio Transmitter & Receiver Modules

Anacon Power & Controls Relay Assembly Specialists An Anacon Electronic Sales, Inc. Company

RF4432PRO wireless transceiver module

Anacon Power & Controls

FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

ERONE CH RECEIVER

4 Channel RF Remote Controller with Momentary Outputs

QM Radio Transmitter Module

Wireless Pulse Transmitter and Receiver System. Ideal for slumpstand wireless metering application

2 hopping code buttons. 4 hopping code buttons. Visor mount or. 2 hopping code buttons. Wall mount. Visor mount or. 4 hopping code buttons.

RF4432 wireless transceiver module

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

Model AV-300AHD-MINI

P700-WLS ioprox Receiver

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

ST12 CODEC IR/RF Remote Control Encoder/Decoder IC 1. Overview

Microprocessor Control Board Set Up Procedures (OR PLC)

AM / FM RADIO TRANSMITTER KEYFOBS

FM-RTFQ SERIES FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Radio receivers type DB317 and DBR1-M4

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

Blue Point Engineering Inc.

Blue Point Engineering

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

Assistive Listening Systems. RX-6 User s Guide

STD-402 SYNTHESIZED TRANSCEIVER UHF FM-NARROW BAND RADIO DATA MODULE. [Direct Mode Operation Guide] Version1.2a (April, 2000) CIRCUIT DESIGN,INC.

SV613 USB Interface Wireless Module SV613

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

T150C / T151C Configurator

LW MHz / 433 MHz ASK Receiver Preliminary Data Sheet Rev 0.3, August, 2006

xepton 2.4 GHz Tour Guide System User manual xepton RP-1 stationary repeater

CS2010 AND CS2011 ALIGNMENT REFERENCE MANUAL FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA 93003

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

Leijenaar Electronics

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

4612 Reference Guide

SRX882

Ocean Controls KT-5221 Modbus IO Module

OSMAC RDR Low-voltage Retrofit Kit

Transcription:

FMR15101 1-Channel 151MHz Receiver Features Single channel receiver with relay output Supply voltage can be AC or DC Low current consumption Built-in noise or signal strength indicator User can select 8 different frequencies Easy code setup with dip switch settings Momentary, latching, timed and security latching output modes can be selected by the user. Changing the settings on the four-way dip switch does this Optional QM100 bracket available for easy mounting to cases or walls. C1015 or C1020 case is also available Applications Pump Control Long distance panic button On/Off applications in agricultural devices Security alarm Basic Telemetry eg. Water level indication Description This receiver gives you a single relay output with a contact rating of 5 amps at 240VAC. The relay mode can be set to momentary, latching, security latching, adjustable timed off delays or pulsing. The user can select 8 different narrow band frequencies and program unlimited number of transmitters to the receiver. With a narrow band FM 151MHz signal from the transmitter a line of sight operating range of 5000 metres is possible. The receiver uses a crystal oscillator circuit that ensures high frequency stability allowing optimal performance in the receiving range. Coding The 12 way dip switch on the receiver sets the 12 bit unique code for the system. This has to be matched to that on the transmitter. Apart from the 12 way dip switch there will be an additional dip switch depending upon the receiver type: Single channel receiver will have a 3 way dip switch. This DIP switch on the right side of the 12 way dip switch denotes the channel. See table below. Generally to use a 1 channel Tx to 1 channel Rx match all the 15 dip switch (12way + 3way just on the right side of the 12 way). To use a multi channel Tx to control a number of (up to 8) Rx, refer to the table below for the switch setting.

FMR15101 3-Way DIP Switch & Relay Output SW13 SW14 SW15 Relay OFF OFF OFF Ch1 OFF OFF ON Ch2 OFF ON OFF Ch3 OFF ON ON Ch4 ON OFF OFF Ch5 ON OFF ON Ch6 ON ON OFF Ch7 ON ON ON Ch8 Different Modes for the Output Modes are user selectable from the 4-way dip switch, shown below. 4-Way Dip Switch Mode Settings The output relay will respond in the following manner when receiving the correct signal from a transmitter "Momentary": Relay on, only while correct signal is received "Latching": Relay alternates at every correct incoming signal "Delayed Off 1": Relay on, but delayed off for 1-10 seconds, adjustable by trimpot "Delayed Off 2": Relay on, but delayed off for 10-300 seconds, adjustable by trimpot "Pulsing": Relay will pulse at 1Hz for 10-300 seconds, adjustable by trimpot "Security latching On": Relay will energize until supply to receiver is momentarily interrupted "On-Off": This mode requires a 2-channel Tx. Channel 1 will always energize the relay Channel 2 will always de-energize the relay "Test": Relay is energized, for test purpose only

Output Modes Relay output on the receiver by default the mode is set to momentary. Other modes are selectable from the 4- way dipswitch. Factory Default = Momentary Momentary - Output is active for as long as the transmitter button is pressed. This is a standard mode on most automatic gates or garage door openers. Latching Security Latching - Output remains active until next press of the transmitter button. Similar to switching "on" and "off" a light. - Output remains active until power to the receiver is removed. Similar to security alarms and fire alarms. Signal Strength Indicator The 151MHz receivers have five blue LED s on the board. The table below indicates the level of the valid transmitted signal. 5 LED s on -70dBm Very Strong signal Very Reliable operating conditions 4 LED s on -75dBm Very Strong signal Very Reliable operating conditions 3 LED s on -80dBm Very Strong signal Very Reliable operating conditions 2 LED s on -90dBm Strong signal Very Reliable operating conditions 1 LED on -100dBm Good signal Reliable operating conditions Noise Strength Indicator If more than 1 led is ON without a valid transmission, this indicates that there is noise on the frequency selected. Change the 3-way dipswitch on the receiver module to select a different frequency. Following is a table with the Dipswitch settings and the corresponding frequencies.

Frequency 1 2 3 151.600 MHz On On On 152.375 MHz Off On On 151.775 MHz On Off On 151.400 MHz Off Off On 151.175MHz On On Off 151.025 MHz Off On Off 150.900 MHz On Off Off 150.825 MHz Off Off Off Technical Data Supply Voltage Current Consumption Receiving Frequency Operating Temperature Range Sensitivity Type of Demodulation Connection Antenna Dimensions 11.0-28.0 VDC 10.0-28.0 VAC Can use Elsema AC power pack (PP12 / PP24) Supply lines should be less than 3m long to comply with radio frequency authorities 24mA Standby at 12VDC 57mA when relay ON at 12VDC 151.6MHz (8 selectable frequencies. See table above) -5 to 50 C Mounting Hole Size 3.97mm or 5/32 Weight Useable Transmitters Useable operating range Better than 0.5uV (For relay to activate) Narrow-Bandwidth Frequency Modulation (FM) Supply, Antenna & Outputs - Screw type terminal block 50Ω, 151MHz Antenna, Elsema ANT151M for maximum performance A piece of approximately 1metre wire can be used for short range applications 95 x 70 x 20mm 83g All FMT151 series (with correct setting on the dip switch). See Transmitter datasheet for details. Up to 5000 metres, depending on installation and type of antenna used. Recommended Antenna is Elsema ANT151M

Products in the Range FMR15101 1-Channel FMR15102 2-Channel FMR15101240 1- Channel 240VAC Supply FMR15102240 2- Channel 240VAC Supply FMR15104 4-Channel FMR15104240 4- Channel 240VAC Supply FMR15108 8-Channel FMR1510812R 8-Channel, 12V Supply FMR1510824R 8-Channel, 24V Supply

Block Diagram ELSEMA

FMR15101 12/24 VAC/DC Application ELSEMA

FMR15101 110/240 VAC Application Manufactured by Elsema Pty Ltd 31 Tarlington Place, Smithfield NSW 2164 Ph: 02 9609 4668 Fax: 02 9725 2663 Website: http://www.elsema.com Distributed by: