A Clamp W/TRMS

Similar documents
Amp Clamp W/True RMS

SureTest Circuit Analyzers

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

600A Clamp Meters w/tightsight Display

700 Series 740 Series 760 Series 770 Series

TESTING & MEASUREMENT

G R E G E D WA R D S

Fluke Digital Multimeters Solutions for every need

+/- (3 PERCENT +2) AC VOLTAGE, +/- (2 PERCENT +2) DC VOLTAGE, +/- (5 PERCENT +3) RESISTANCE. User Manual, Test Lead Wrap, TP2 Test Probes

Testing & Measurement. FEATURED Products. SF-780 Metal Locator. NEW-CM450 True RMS Clamp Meter. NEW AM-6 Analog Multimeter

Testing & Measurement

Electrical and HVAC Test Tools

Insulation Testers and Earth Ground Testers

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Fluke Digital Multimeters Solutions for every need

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Testing & Measurement

TABLE OF CONTENTS. Wire Termination. Tools & Supplies. Stripmaster Wire Strippers. Test & Measurement. DataComm/Networks

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

1587/1577 Insulation Multimeters

LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Tested Tough. Trusted Safe.

Fluke 170 Series True-rms Digital Multimeters

DL389 G2PHOENIX PRO+ True RMS Clamp Meter

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

79/26 Series III Multimeter

Take the current. Clamp meters available for diverse applications and conductor diameters.

USER'S MANUAL DMR-6700

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA220

1507/1503. Insulation Testers. Technical Data. Features and benefits:

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Fluke digital multimeters. Solutions for every need

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES Capacitance Meter

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

DM-46 Instruction Manual

Testboy 65 Automotive-Multimeter

Fluke 1587 FC/1577 Insulation Multimeters

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

200Amp AC Clamp Meter + NCV Model MA250

Analog Digital Multimeter with Insulation Resistance Measurement

APPA 300 Series. The Most User-Friendly High Performance Multimeter

400Amp True RMS AC Clamp Meter + NCV

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

BENCH METER Model>9803. Wavecom Instruments

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

400Amp True RMS AC/DC Clamp Meter Model EX613

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

ELECTRICAL TESTING EQUIPMENT. CLM100 Cable Length Meter. DMEG3 Digital Insulation Resistance Tester. IRT3 Analog Insulation Resistance Tester

Autoranging Multimeter Extech EX503

USER'S MANUAL DMR-4350

Extech Temperature & Humidity Dataloggers

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

DM-45 Digital Multimeter

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

UAT-600 Series. amprobe.com

AC/DC CLAMP METER USER S MANUAL

Clamp Meter ABCs. Application Note. The transformer action

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

DM-46 Instruction Manual

Measure voltage without test leads. Product Highlights

Current Clamp. 210

Clamp Meter ABC s APPLICATION NOTE. The transformer action. Choosing your clamp meter

ABCs of DMMs Multimeter features and functions explained Application Note

DIGITAL CLAMP METER Use s Manual

Keysight Technologies U1210 Series Handheld Clamp Meters

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

ABCs of DMMs. Multimeter features and functions explained. Application Note. Introduction. Choosing your DMM. Some basics

DIGITAL / ANALOG HiTESTER SERIES

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

Analog Technologies. Multimeter 15B and17b

Electrical Measuring Instruments. Vol.3.

Dawson DDM190. Digital Multimeter User s Manual

AC Clamp Meter + Phase Rotation Tester

Fluke Clamp Meters Solutions for every need

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Insulation resistance testing. A complete solution for every person.

IDM 98-III & IDM 99-III Digital Multimeters

AX-C Introduction. 2. Safety Information

MS2030 CAT III 600 V A V AUTO RS232

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

312, 316, 318. Clamp Meter. Users Manual

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61763 660A Clamp W/TRMS Ideal Catalog Number 61763 Manufacturer Ideal Ideal, Clamp Meter, Tightsight, 760 Series With TRMS, Capacitance, Frequency, Resistance: 0 to 999.9 Ohm, 1000 to 9999 Ohm At 1.5PCT + 5 Accuracy, Capacitance: 0 to 999.9 MFD At 5 PCT Plus 15 Accuracy, Display: 4 Digit LCD With 9999 Counts For Both Displys With 41 Segment Analog Bar Graph On Front Display Weight per unit 1.8 (lbs/each) Product Category Meters, Panel Instruments Features Accuracy Stated Accuracy At 23 DEG C Plus Or Minus 5 DEG C, Less Than 75 PCT R.H battery 100 HR Continuous With Alkaline (, ) Capacitance 0 To 999.9 MFD At 5 PCT Plus 15 Accuracy dimensions 8.700 IN Height X 3.100 IN Width X 1.800 IN Depth diode test Yes Yes/No display 4 Digit LCD With 9999 Counts For Both Displays With 41 Segment Analog Bar Graph On Front Display Resistance 0 To 999.9 OHM, 1000 To 9999 OHM At 1.5PCT + 5 Accuracy Voltage Rating 750//999 VAC//VDC

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 s Long Product Type special features Manufacturer Information Brand IDEAL GTIN 00783250724017 Manufacturers Part Number 61763 sub brand TightSight UPC 783250724017 660A CLAMP W/TRMS IDEAL, Clamp Meter, TightSight, 760 Series With TRMS, Capacitance, Frequency, Resistance: 0 To 999.9 OHM, 1000 To 9999 OHM At 1.5PCT + 5 Accuracy, Capacitance: 0 To 999.9 MFD At 5 PCT Plus 15 Accuracy, Display: 4 Digit LCD With 9999 Counts For Both Displys With 41 Segment Analog Bar Graph On Front Display Clamp Meter, Ideal, Tightsight, 760 Series With TRMS, Capacitanc Features: 660 A True Rms Clamps For A Variety Of Industrial And Commercial Environments; Unique Tightsight Bottom Display Makes Hard-To-Reach Measurements Convenient; Easy-To-Read Displays Feature Large Numbers And Green Glowing Backlight; Cat IV Rating For Maximum Safety; Frequency, Capacitance, Peak, Data Hold, Max/Min; High Frequency Rejection; High Frequency Rejection (Hfr) And Emi Shielding Features Provide Accurate Voltage/Frequency Readings On Non-Sinusoidal Wave Forms, Such As Adjustable Speed Dri Taxonomies, Classifications, and Categories Category TEST EQUIPMENT, TESTERS AND METERS Type 760 Series With TRMS, Capacitance, Frequency Packaging Carton 12 Weight Per each 1.79 Uses, Certifications, and Standards Application For A Variety Of Industrial And Commercial Environments standard CAT III-1000V, CAT IV - 600V, UL 61010 Listed, CE, C 12966 Temperature Rating 32 to 122 F

Test & Measurement Clamp Meter Selection Guide 700 Series 740 Series 760 Series 770 Series Clamp Meters CLAMP METER SELECTION GUIDE MEASUREMENT FUNCTIONS AC Voltage DC Voltage AC Current DC Current Resistance Audible Continuity Diode Test Capacitance Frequency FEATURES Display Type (Digital) D D D D D D D D AC Current Capacity 200 200 600 600 660 660 1000 1000 DC Current Capacity 660 1000 True RMS Auto Ranging Auto/Manual Ranging Data Hold Max Hold Peak Hold Min/Max DCA Zero Auto Power Off Non-Contact Voltage Indication Harmonics Indicator Vibration Mode Backlight Low Battery Indication High Voltage Warning Overload Protection on all Ranges Conductor Size Inches (mm) 61-702 1.3 (33) 61-704 1.3 (33) 61-744 1.5 (38) 61-746 1.5 (38) 1.4 (36) 1.4 (36) 2.0 (51) Warranty (years) 2 2 2 2 2 2 2 2 CERTIFICATIONS UL 61010 Listed CAT III, 100V/CAT IV 600V III III III III IV IV IV IV CE 2.0 (51) D-2 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance

TightSight Clamp Meters 1000 & 660 Amp TightSight bottom display Tapered jaws with hook tip Measures AC current True RMS AC/DC Voltage Capacitance Audible continuity Frequency via clamp head or test leads Resistance High frequency rejection* Peak hold N12966 600V 1000V Max/min hold Data hold 1000A Clamp () Selectable audible and visual voltage alerts on AC/DC voltage functions Selectable auto power off Backlit display Low battery indicator 2-year warranty 660A Clamp () Exclusive TightSight Display Cat. No. 1000AAC Clamp Meter 1000A AC/DC Clamp Meter 660AAC Clamp Meter 660A AC/DC Clamp Meter Includes: Carrying Case and Test Leads w/alligator Clip. Specifications Range & Resolution AC Current DC Current 0.0-999.9A 0.0-660.0A 0.0999.9A AC Voltage 0.0-660.0A Accuracy 2.0% 2.0% 0.0-750.0V 1.0% DC Voltage 0.0-999.9V 1.0% Resistance 0.0-999.9Ω 1.5% Capacitance 0.0-999.9µF 5.0% Continuity 0.0-999.9Ω Audible @ <30Ω Frequency 20.0-400.0Hz 0.5% Jaw Size 1-800-435-0705 Customer Assistance Clamp Meters *Reads accurately on noisy electrical circuits. 2 (51mm) 1.42 (36mm) WWW.IDEALINDUSTRIES.COM D-3

Thermocouple Measures up to 1500 F (816 C) K-type thermocouple plugs into digital multimeter voltage jacks with 61-465 adapter 61-461 Cat. No. Beaded K-type Thermocouple 61-461 Thermocouple Adapter 61-465 61-465 Carrying Cases 61-010 C-90 C-290 61-445 Cat. No. Leather Carrying Case - for use with 61-065, 61-076, 61-085, 61-086 61-010 Small Nylon Carrying Case w/four pockets 61-445 Nylon Carrying Case - for use with all Vol-Con and Vol-Test Voltage Testers C-90 Nylon Carrying Case - for use with Digital Multimeters C-290 Carrying Case Selection Guide Accessories VOLTAGE TESTERS 160 310 340 360 480 490 610 700 740 760 770 830 61-059 61-065 61-076 61-085 61-086 61-090 61-092 61-096 61-164 61-165 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-610 61-614 61-702 61-704 61-744 61-746 61-830 61-179 Nylon Carrying Case C-50 Nylon Carrying Case C-90 Nylon Carrying Case C-230 Nylon Carrying Case C-290 Nylon Carrying Case C-700 Nylon Carrying Case C-760 Nylon Carrying Case C-770 Nylon Carrying Case 1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM D-21

Test & Measurement Replacement Parts Selection Guide METER REPACEMENT PARTS SELECTION GUIDE 090 310 340 360 480 490 600 610 700 740 760 770 790 61-096 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-605 61-610 61-614 61-702 61-704 61-744 61-746 61-795 61-797 Replacement Parts/Safety FUSES F-1 0.5A (250V) 6.35 x 38mm F-105 1A (600V) 10.3 x 35mm F-310 250mA (250V) 5 x 20mm F-312 500mA (250V) 5 x 20mm F-314 10A (250V) 5 x 20mm F-340 0.5A (500V) 6.35 x 32mm F-341 10A (1000V) 10 x 38mm F-497 440mA (1000V) 10 x 35mm F-498 11A (1000V) 10 x 38mm F-797 315mA (1000V) 5 x 32mm LA-3893 2A (600V) 6.35 x 25.4mm LA-3898 0.25A (500V) 5 x 32mm BATTERIES 61-201 1.5V (LR44) 1.5V (AA) 1.5V (AAA) 9V TEST LEADS TL-34 Leads w/pin connectors TL-56 Test leads TL-95 Test leads TL-100 Test leads w/alligator clips TL-102 Silicone test leads TL-104 Test leads w/large alligator clips TL-310 Test leads TL-795 Test leads TL-797 Test leads Safety in the Field The power demands of today s high-tech world have caused a marked increase in occurrences and levels of transient overvoltages. The International Electrotechnical Commission (IEC) has developed a safety standards model for measurement, control and laboratory use. Category I The signal level for telecommunications, electronic and other low-energy equipment with transient-limiting protection. Peak impulse transient range is 600 4,000 volts with a 30 ohm source. Category II The local level for fixed and non-fixed powered devices including appliances, lighting and portable equipment. Outlets located more than 30 feet from CAT III sources and 60 feet from CAT IV sources. Peak impulse transient range is from 600 6,000 volts with a 12 ohm source. Category III The distribution level for fixed primary feeders or branch circuits. Circuits that are separated from CAT IV sources by at least one level of transformer isolation. Peak impulse transient range is 600 8,000 volts with a 2 ohm source. Category IV (proposed) The primary supply level for the highest levels of transient overvoltage. Includes the utility service both outside and at the service entrance, service drop from the pole to the building, overhead line to remote buildings, and underground line to a well pump. Peak impulse transient range is 600 12,000 volts with less than a 1 ohm source. Visit our website for more technical product details, application support, white papers, videos and software! Meter Safety in the Field CAT I Copiers Electronic equipment Low energy equipment with transient limiting protection CAT II Appliances, PCs, TVs Outlets and long branch equipment All outlets at more than 10m (30 ft) from Category III source All outlets at more than 20m (60 ft) from Category IV source Service Entrance Service Entrance Service Entrance Meter CAT III MC Panels Underground Service Feeders and short branch circuits Distribution panel devices Heavy appliance outlets with short connections to service entrance Outbuilding Transformer Outbuilding Meter Underground Service CAT IV Exterior Transformers, Meters Outside and service entrance Service drop from pole to building Overhead line to detached building Underground line to well pump D-22 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance