Type VDG 13 Undervoltage Relay

Similar documents
CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

Type CAEM 21 Battery Earth Fault Relay

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

Type VAEM 22 Negative Potential Biasing Relay

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

! CAUTION D TABLE 1

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Instantaneous Overcurrent Relay

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

3 Pole high impedance differential relay 7VH83

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Page 13-2 Page Page 13-7

Stabilized Differential Relay SPAD 346. Product Guide

Capacitor Switching Contactors

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

Type CA Percentage Differential Relay for Transformer Protection (50 and 60 Hertz)

Reyrolle Protection Devices. 7PG11-18 Alpha Electromechanical Relays. Siemens. Answers for energy.

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

INSTRUCTION MANUAL FOR VARIABLE PERCENTAGE DIFFERENTIAL RELAY BE1-87G

1% Switchgear and Substations

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

page 2 of 86 Report reference No:

Overcurrent Protection / 7SJ45

INDICATOR TYPE RXSK 2H

DIGITAL EARTH FAULT RELAY

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

POWER SYSTEM II LAB MANUAL

DIAC Type 66K. DIGITAL OVERCURRENT RELAY Instruction Manual. GE Power Management

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

INSPECTION 1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Type KLF Generator Field Protection-Loss of Field Relay

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

PD300. Transformer, generator and motor protection Data sheet

Power systems Protection course

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Type: DILM40(RDC24) Article No.:

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

SPAE 010, 011 High Impedance Protection Relay

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

NEMA Contactor and Starter Specifications

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

1 340XRi / 680XRi / 1220XRi Applications. 340XRi, 680XRi, 1220XRi Application manual.

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

PROTECTION of electricity distribution networks

Advantages. Applications

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Table 1 Various IRD models and their associated time/current characteristics Time/Current Characteristics. Definite Time Moderately Inverse Time

Protection and safety SQZ3 phase and sequence relay

The Reliable Source... FERROPERM. Inductors. Transformers

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

SPAD 346 C Stabilized differential relay

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

3. COMBINED TRANSFORMERS Oil-paper insulation

L O V A G. T E S T I N S T R U C T I O N I E C / E N E d C O N D I T I O N S F O R T E S T I N G

Onsite Mobile AC High Voltage Test System

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C

N. TEST TEST DESCRIPTION

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Protection and control VIP300. Technical manual

Relay Types and Applications Dr. Sasidharan Sreedharan

3 - Protection components Circuit-breakers

Reyrolle Protection Devices. 7PG18 - TR-A High speed tripping Relay. Energy Management.

Type: DILEM 10 G(24VDC) Article No.:

Application and Commissioning Manual for Numerical Over Current Protection Relays Type MIT 121/131 CONTENTS PAGE APPLICATION 2-4 INSTALLATION 5-11

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

N. TEST TEST DESCRIPTION

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Automatic synchronising relay

Electronic circuit breaker ESS30-Sxxx-DC24V

3. Contact Form A: SPST-NO

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Overcurrent Protective Relays

Electricity Fundamentals Training System

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Earth Fault Relay EFSPL-1A/5A

Transcription:

Type VDG 13 Undervoltage Relay

Type VDG 13 Undervoltage Relay VDG 13 relay withdrawn from case Features l Identical time/voltage characteristics on all taps. l Frequency compensated. l Simple construction, easily accessible. l Comprehensive range of auxiliary unit ratings. l Dust tight drawout case and tropicalised finish. Application Relay type VDG 13 is an inverse time undervoltage protection of ac circuits, capacitors, rectifiers and machines such as induction motors. Description Relay type VDG 13 is a heavily damped, frequency compensated induction disc relay with adjustable inverse time/voltage characteristic. With the relay electro-magnet deenergised, the disc contact is held in the closed position by a spiral control spring. When the rated voltage is applied to the relay coil, a torque is produced in the contact opening direction and when the applied voltage falls below the setting value, the control spring torque overcomes the driving torque and closes the contact. Damping of the disc movement is by a removable high retentivity permanent magnet. The unique method of winding the operating coil ensures that the time/ voltage characteristics are identical on each of the voltage taps. Selection of the required voltage setting is by means of a link board which has a single insulated link. Taps on the operating coil and a series resistance are connected to the link board and provide a constant inductance/resistance ratio on each voltage setting and frequency compensation effect is obtained by using the correct combination of coil reactance and resistance. The relay operating time can be adjusted by means of the disc backstop which is controlled by rotating a knurled moulded disc at the base of the graduated time multiplier scale. Type VDG 13 relay is a single pole relay.

Technical data Voltage ratings and settings The relay can be supplied having a voltage rating of 110, 240/250 or 440 V ac, 50 Hz. For 240/250 or 440V relays, external voltage transformers are supplied. The following setting range is available: 50-90% adjustable in five equal steps at 10%. Resetting voltage The disc will completely reset at 105% or less of the voltage setting. Operating time 0-5.0 seconds at zero voltage. Time/voltage characteristic at time multiplier setting 1.0 as given in Figure 1. Resetting time With the time multiplier set at 1.0, when the applied voltage suddenly increases from zero to rated voltage, the resetting times are as follows: Relay setting 30 40 50 60 70 80 90 (%) Resetting time 1 1.5 2 4 5 10 12 (seconds) Burdens 5.0VA at voltage setting At rated voltage, the burdens are as follows: Relay Setting 50 60 70 80 90 (%) VA at rated 20 14 10.5 8 6 voltage Figure 1: Time/voltage characteristic at time multiplier setting 1.0 Frequency error The maximum pick-up variation between 40 and 70 Hz is 7%. Auxiliary units and operation indicators The relay has a voltage operated auxiliary unit fitted with two pairs of normally open self reset contacts arranged to reinforce the disc contact. It is also fitted with an operation indicator which is hand reset by means of a push-rod protruding through the relay case. Coil ratings 24V dc - 240V dc. Contact ratings The single disc contact will make and carry for 0.5 s, 2500VA with maxima of 10A and 660V ac or dc. The two pairs of electrically separate, self reset contacts provided on the auxiliary unit will make and carry for 0.5 sec 7500VA with maxima of 30A and 660V ac or dc. Insulation The relay meets the requirements of IS 3231/IEC 255-5 Series C - 2 kv for 1 minute. External and internal circuit connections Typical external and internal connections for type VDG 13 undervoltage relay with shunt reinforcing indicators is shown in Figure 2. Case Relays are supplied in drawout cases suitable for flush or projection mounting and are finished eggshell black and tropicalised. The drawout feature considerably simplifies maintenance and permits testing to be carried out easily and quickly. A cradle mounted isolating switch is provided which automatically isolates the trip circuit when the cradle assembly is withdrawn from the case for maintenance. This prevents any inadvertent tripping of the circuit breaker. A filter breather is fitted which equalises pressure inside and outside the case without admitting dust. Type VDG 13 relays are mounted in size 1D vertical case. Thermal rating The relay will withstand 120% rated voltage on any setting continuously for 60 C rise in coil temperature. Accuracy The operating value conforms to error class index E 5.0 as per BS 142 and 5.0 as per IS 3231 at the voltage setting. The operating time at time multiplier setting 1.0 conforms to the time/ voltage characteristic given in Figure 1, subject to a tolerance of ±7.5% at zero voltage. Figure 2: Typical external and internal connections for relay type VDG 13

Dimensions and weights Maximum overall dimensions Approximate Relay Case Height Width Depth* gross weight size mm mm mm Kg. VDG 13 1D vert 233 170 203 6.0 External 127 114 114 4.5 transformers * Add 76 mm for maximum length of terminal studs, alternatively, 29 mm for terminal screws. Information required with order 1. System frequency and application. 2. Voltage rating (110, 240/250 or 440V ac). 3. Auxiliary contacts - hand or self reset. The approximate gross weights given above are inclusive of cartons, mounting appendages and terminal details. The relays comply fully with the requirements of IS 3231 and are suitable for use in normal tropical environments.

ALSTOM Limited Pallavaram Works: 19/1, GST Road, Pallavaram, Chennai-600 043. India. Tel: 91-044-2368621 Fax: 91-044-2367276 Email: plw.applications@alstom.sprintrpg.eml.vsnl.net.in. 1998 ALSTOM Limited Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. ALSTOM Limited cannot be held responsible for any reliance on any decision taken on its contents without specific advice PR:072:0799:A Printed in India.