Inductive Voltage Transformers. Types VEOT and VEOS

Similar documents
Combined Instrument Transformers. Types IVOKT and TMC

Current Transformers. Type OSKF

E (Capacitor Voltage Transformers) Transformer section of the Trench catalogue. Product Range

Line Tuners. Total Relay Communications

Earth-Fault Compensation Controller EFC30 / EFC40

LOPO. Low Power Instrument Transformers. For Medium Voltage Switchgear

Excellence in Instrument Transformers

Capacitive voltage transformers

Capacitive voltage transformers

with our customers. marketplace. Trench is an international market leader, with strengths that

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Resistive capacitive voltage divider

Resistive capacitive voltage divider

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

3. COMBINED TRANSFORMERS Oil-paper insulation

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Ritz Instrument Transformers GmbH. Welcome

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Resistive capacitive voltage divider

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Swiss quality combined with global experience

Ohmic Voltage Sensor GSER 16

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Outdoor Instrument Transformers Buyer s Guide

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Oil insulated Outdoor Instrument Transformers Buyer s Guide

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

INSTRUMENT TRANSFORMERS. Product Spectrum

User s Manual For CT Model IMB

Non-conventional instrument transformers and power quality aspects an overview

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Inductive conductivity transmitter JUMO CTI-Junior

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Arc Suppression Coils

OPTIFLUX 1000 Technical Datasheet

Energy Division. Bowthorpe LV/MV Surge Arresters

AC Resonant Test Systems Tank Type Up to 150 kv

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Outdoor Instrument Transformers. Buyer s Guide

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

OPTIFLUX 5000 Technical Datasheet

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

OIL-IMMERSED ARC-SUPPRESSION COILS

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

AC Resonant Test Systems Tank Type Up to 500 kv

Onsite Mobile AC High Voltage Test System

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

LF Conductivity Measuring Probe

AC Dielectric Test Sets

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Type SSVT oil-filled station service voltage transformer Auxiliary power from high voltage transmission lines

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

CDAX 605 High Precision Capacitance & Dissipation Factor Test Set

OPTIFLUX 5000 Technical Datasheet

Introduction. Centrado leading-edge transformer. Introduction

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

TECHNICAL DATA TYPE SHZV VACUUM ON-LOAD TAP CHANGER FOR OIL-IMMERSED TRANSFORMER

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

KINAX SR 719 Programmable Transmitter for Position Feedback

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Liquid-Filled Transformers

POTENTIAL TRANSFORMER

MAVOWATT 4 Multifunction Power Meter

POWER TRANSFORMERS CATALOGUE

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

TRAX Transformer and Substation Test System

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Cast resin transformers HARMONY TM

AT Current Instrument Transformer Instructions for installation, use and maintenance

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

CAST RESIN DRY TRANSFORMER

MBC /602(L) MBC /602(L) MBC /602(L)

Liquid level monitors and controls

Flexibility and efficiency on high accuracy machining

Primary Test Manager (PTM) Testing and management software for primary assets

Transcription:

Inductive Voltage Transformers Types VEOT and VEOS

Inductive Voltage Transformers Introduction Trench is a recognized world leader in the design and manufacture of high voltage equipment for application on electric utility and high energy industrial systems. As part of Trench's product scope, the Company produces a diversified range of Instrument Transformers which are installed on 69-800 kv electrical systems. Instrument Transformers include: Voltage (Potential) Transformers (both inductive and capacitive type), Current Transformers and Combined Instrument Transformers (voltage and current transformer in one unit). Voltage Transformers must convert transmission class voltages to standardized low and easily measurable values, which will be used for metering, protection and control of the high voltage system. As such, the need for accurate and reliable voltage transformation is essential. Fig. 1 Type VEOT 72,5(left) and VEOT 25(right) oil/paper Insulated Voltage Transformers This brochure will detail the features and characteristics of types VEOT and VEOS inductive type Voltage Transformers. Please refer to Trench brochure E210 for additional general information concerning high voltage Instrument Transformers. 2

Features Meet all IEC and ANSI metering and protection classes (other standards on request) Standard thermal burden ratings of 2000-2500 VA (higher on request) Quality Assurance in accordance with ISO 9001 highly refined and processed oil/paper insulation system low weight and minimum oil volume use of high quality mineral oil, PCB free, biological decomposition excellent seismic performance as a consequence of optimized designs of flanges, porcelain and their interconnection excellent control of internal and external insulation stresses through the use of a proprietary finely graded bushing system essentially unaffected by stray external magnetic fields hermetically sealed stainless steel metallic bellows for units rated 123 kv and above welded housings sealed without screws stable accuracy over a long period of time perfect transient performance suitable for line discharging exclusive use of corrosion-resistant materials explosion resistant by - insulating system with high reliability - fine graded bushing - weak point in the aluminium head and tank castings and the metallic bellows serving as pressure release device successful field experience since the manufacture of the first voltage transformer in 1926 maintenance free during a long life time of more than 30 years composite insulator available on request 3

Construction Standard Equipment Optional Equipment Trench types VEOT and VEOS Inductive Voltage Transformers are designed and constructed with the well proven, highly reliable, oil/ paper insulation system. Each porcelain housed, hermetically sealed Voltage Transformer is equipped with stainless steel expansion bellows, calibrated to the internal oil volume and extremes in ambient operating temperatures. For voltage classes up to 300 kv, the type VEOT is offered. For applications above 300 kv, Trench offers the type VEOS design. The VEOS is designed with a primary winding which is located in the mid-point of the structure. This feature serves to reduce the dielectric stresses and ensures optimized voltage distribution within the transformer. Please refer to figure Fig. 3 for the internal schematic diagram and mechanical details for both the VEOT and VEOS units. aluminum flat pad primary terminal/ground terminal Iifting lugs bellows position indicator oil filling port oil drain valve secondary terminal box with removable gland plate stud type primary terminal primary or ground cable connector Anti-corona rings Capacitance tap for measurement of tan delta of bushing or high voltage winding Gas Detection System (contact Trench for additional details) Secondary fuses or circuit breakers Terminal box heater Composite insulator Fig. 2 Inductive Voltage Transformers VEOT

Sectional view VEOT VEOS 1 15 3 2 11 3 2 1 15 11 12 12 1 10 17 16 13 12 16 1 17 10 5 13 7 6 9 8 7 5 6 9 8 1 2 3 5 6 7 8 9 10 11 12 13 1 15 16 17 Primary terminal Metallic expansion bellows Oil filling screw Porcelain insulator Secondary terminal box Secondary terminals Oil drain valve Grounding terminal Gland plate Lifting lugs Bellows indicator Bushing Secondary winding Primary winding Transformer head (aluminum) Tank (aluminum) Iron core VEOT A 1a 1n 2a 2n da dn N Fig. 3 Electrical and Mechanical design details VEOS 1a 1n 2a 2n A N 5

Oil/Paper-insulated Inductive Voltage Transformers Electrical and Mechanical Data (1) Type Max. continuous test voltage Impulse Switching min. Standard operating voltage 50/60Hz withstand impulse test sparking creepage phase to phase 1 min. dry/wet 1.2/50 µs voltage distance distance kveff kveff kvpeak kvpeak mm mm VEOT 72.5 HT 72.5 10 325 630 1815 VEOT 72.5 72.5 10 325 700 1815 VEOT 123 123 230 550 1200 3815 VEOT 15 15 275 650 1200 3815 VEOT 170 170 325 750 100 95 VEOT 25 25 395 950 2200 6300 VEOT 25 25 60 1050 2200 6300 VEOT 300 300 60 1050 850 2200 6300 VEOS 362 362 570 1300 950 2650 9050 VEOS 20 20 630 125 1050 3200 11025 VEOS 20 20 680 1550 1050 3200 11025 VEOS 550 550 680 1550 1175 3800 13750 Notes: (1) Other ratings available on request 6

h1 h1 Fig Net weight Dimension Weight of oil (approx) h1 h2 kg mm mm kg 50 Fig. A 50 Fig. B A 210 1515 0 B 290 2060 0 B 310 2560 3 B 320 2560 5 B 330 2760 7 C 670 3650 115 C 670 3650 115 C 670 3650 115 D 1020 5100 765 220 D 1200 5650 5315 20 D 1200 5650 5315 20 D 150 6300 5960 265 h1 h2 h1 600 600 Fig. C Fig. D 7

Trench Facilities The Trench Group is your partner of choice for electrical power transmission and distribution solutions today; and for the development of your new technology solutions of tomorrow. Trench Austria GmbH Paschinger Strasse 9 Postfach 13 A-060 Linz-Leonding Austria Phone: 3-732-6793-0 Fax: 3-732-67131 Trench Brasil Ltda Via Expressa de Contagem, 2685 Contagem, Minas Gerais CEP 32370-85 Brazil Phone: 55-31-3391-5959 Fax: 55-31-3391-1828 Trench China MWB (Shanghai) Co., Ltd. No. 3658, Jiancheng Road Minhang, Shanghai Peoples Republic of China 20025 Phone: 86-21-5720088 Fax: 86-21-5723118 Trench High Voltage Products Ltd., Shenyang No. 2 Zhengliang Er. Road Jing Shen Xi San Street Dao Yi Economic Development Zone Shenyang 110136 P.R. China Phone: 86-2-89722688 Fax: 86-2-89737200 Trench Limited Bushing Division 32 Monarch Avenue Ajax, Ontario Canada L1S 2G7 Phone: 905-26-2665 Fax: 905-26-2671 Trench Limited Coil Product Division 71 Maybrook Drive Scarborough, Ontario Canada M1V B6 Phone: 16-298-8108 Fax: 16-298-2209 Trench Limited Instrument Transformer Division 390 Midwest Road Scarborough, Ontario Canada M1P 3B5 Phone: 16-751-8570 Fax: 16-751-6952 Trench Limited Power Line Carrier Division 815 Middlefield Road, Unit 6A Scarborough, Ontario Canada M1V 2P9 Phone: 16-291-85 Fax: 16-291-5581 Trench France S.A. 16, Rue du Général Cassagnou B.P. 70 F-68 302 St. Louis, Cedex France Phone: 33-3 89-70-2323 Fax: 33-3 89-67-2663 Trench Germany GmbH Nürnberger Strasse 199 D-96050 Bamberg Germany Phone: 9-951-1803-0 Fax: 9-951-1803-22 Trench Switzerland AG Lehenmattstrasse 353 CH-028 Basel Switzerland Phone: 1-61-315-51-11 Fax: 1-61-315-59-00 Trench (UK) Limited South Drive Hebburn Tyne & Wear NE 31 1 UW Phone: -191-83-711 Fax: -191-30-0633 www.trenchgroup.com E 211.21 Subject to change without notice (05.2006) Printed in Canada.