MPS 03.1 Metal Particle Sensor. Instruction manual Version 1.2

Similar documents
MPS 02.1 Metal Particle Sensor. Instruction manual Version 1.1

Exhaust Heads. Helps Reduce Roof Maintenance Costs. Carbon or Stainless Steel Construction Threaded or Flanged Connections FEATURES

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Speed sensors for general applications:

4/3 proportional directional valve direct operated, with integrated electronics

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Proportional Directional Control Valves Nominal sizes 16 and 25

Precipition Sensor with analogue Intensity Output ,

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Magnetic Inductive Flow Sensor induq

Electronically controlled proportional pressure regulating valves

Smart Power Relay E I...

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

Electromechanical pressure and vacuum switches 0

Instruction manual for STA 1 sectional door operator

Proportional Directional Control Valves Size 6

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Digital flow ELEMENT transmitter for continuous flow measurement

Proportional Directional Control Valves Size 6

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

XY-Stages series 5102

PRODUCT MANUAL. Flush Mount 1 mm Cavity TS FM01 K. Training and Technology for Injection Molding. Temperature Sensor

Speed sensor DSA series 12

Analog amplifier RA. RE Edition: Replaces:

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL IO-Link Data Sheet

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

POSICHRON rod-style position sensor PCST25

Temposonics. Magnetostrictive Linear Position Sensors. RT4 SSI Data Sheet. Redundant SSI output High temperature rod IP68 ingress protection

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

DENISON HYDRAULICS Proportional Pressure Control Valves

U5700 Submersible Liquid Level Pressure Transducer

VTMS. Valve Train Measurement Solution. Data sheet

4/3 Proportional Directional Valve, Size SAE 10

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Temposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

The sensor can be operated at any frequency between 0 Hz and 1 MHz.

RESOLUTE ETR (Extended Temperature Range) absolute encoder

Pressure Transmitter SIL

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Precipitation Monitor ,

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

Encoder WDGI 58E.

Actuator LA12 PRODUCT DATA SHEET

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Electrohydraulic Actuator Type PVEP / PVEP-F


Electronic Temperature Transmitters

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

OPTIFLUX 5000 Technical Datasheet

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

NOVOSTRICTIVE Transducer up to 4250 mm touchless. Series TH1

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Encoder WDGI 58H.

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Instruction manual for STA 1 sectional door operator

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Check valve type RK and RB

Magnetic Inductive Flow Sensors induq. Series VMI

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Pressure transmitter For general industrial applications Model A-10

Motorised valve for neutral gases and liquids G 1/2 to G 1 female thread Cartridge system Operating pressure 0.9 to 10 bar (see table)

Directional valves Electrically operated Series 563, 565, 567. Brochure

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

INLINE flowmeter for continuous flow measurement

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

MD 103 ESD TargET SET USEr ManUal B

HAL , 508, 509, HAL Hall Effect Sensor Family

EBR7912EBI-CA-KA Incremental Sensor Module with Reference

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet

ST619LBDR. DC-DC converter regulated 5 V charge pump. Features. Description

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

LinACE absolute linear shaft encoder

Technical Explanations. SKiiP 3 Parallel Board. Technical Explanation SKiiP 3 Parallel Board. This document is valid for the following part numbers:

Direct Drive Digital Control

Direct Operated Proportional DC Valve Series D1FP

Level switch Nivotemp NT-EL, NT-ELD

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH*-8 10 Series

DA 30 High Torque Technical Specification

Transcription:

MPS 03.1 Metal Particle Sensor Instruction manual Version 1.2 Serial-no.:... Version valid from: 31.05.2012

Index Page 1. SAFETY INFORMATION 3 1.1. Dangers of maloperation 3 1.2. Intended applications 3 2. OPERATION AND INSTALLATION 4 2.1. General informations 4 2.2. Measuring principle of the MPS 03.1 4 2.3. Output signal of the sensor 4 2.4. Sensor installation 5 2.5. Electrical connection of the MPS 03.1 6 3. APPENDIX 7 3.1. Technical Data 7 3.2. Pin assignment 7 3.3. Application areas - Compatibility 8 3.4. Trouble shooting 8 3.5. Shipment/ spare parts 8 2

1. Safety information 1.1. Dangers of maloperation The MPS 03.1 underwent a safety check according to IEC 1010-1/ EN 61010 1, part 1. Integrated safety elements ensure safe operation if the device is used as it was intended. In case of maloperation or abuse, as well as in case of insensitivity for application limits and safety regulations, the following threats can occur for: Life or physical condition of the operator, the MPS 03.1, as well as connected machines and systems connected, the accuracy of measurements of the MPS 03.1, the environment. This manual contains information and safety advice, which ensure risk free operations and which help to keep the device in an ideal condition. Therefore it is necessary that all people involved in operating and maintaining the device do note this manual unconditionally. 1.2. Intended applications The MPS 03.1 is an efficient and robust inline diagnostic measuring system for detecting ferromagnetic particles > 350 µm in oil. It works very reliably and does fulfil all requirements of daily measurements. The set is intended and tested to operate with all usual hydraulic and gear fluids as well as synthetic esters. Application limits: Maximum acceptable pressure on the sensor element 20 bar / 290 psi Maximum oil temperature 85 C / 185 F Generally, the MPS 03.1 has to be operated with 24 V DC (ripple < 300 mv pp ). 3

24 V 2. Operation and Installation 2.1. General informations The metal particle sensor MPS 03.1 serves the purpose of detecting metal particles in moving hydraulic and lubricating fluids (also see fluid compatibility in chapter 3.3). Therefore, the sensor has to be installed permanently into the hydraulic or the lubricating cycle, so that the fluid, which is being monitored, is permanently flowing through the measuring channel of the sensor. A standard signal indicates that a metal particle was detected and has passed through the channel. The exact size or the type of metal detected can not be distinguished explicitly by this signal. The minimum particle size which can be detected is defined as iron balls with a diameter of 350 µm at a volume flow within the channel of 60 l/ min. Interpretation of measurements is up to the operator, e.g. number of particles per time unit. Typical applications of the sensor are: - Inexpensive, continuous monitoring of large-scale gears for incipient heavy wear with the increasing number of particles per time unit. - Monitoring component cleanliness, e.g. on flushing test stands. 2.2. Measuring principle of the MPS 03.1 The measurement is based on a multiple inductor technique. If passing through the system of inductors, metal particles will be detected by the high frequency magnetic field. 2.3. Output signal of the sensor Metal particles flowing through the system of inductors induce a signal. If this signal reaches a certain amplitude, a standard signal is triggered and emitted at the output of the sensor. 7 ms The standard signal is a square pulse with an amplitude of 24 V and a pulse length of 7 ms at a sensor operating voltage of 24 V DC. A second, dual output signal serves the purpose of self-diagnostics of the sensor s electronic circuit. A high -level of 24V DC indicates proper condition. Corresponding to this, a low -level indicates faulty condition. The diagnostic signal doesn t give an information if the oil is actually flowing through the sensor. The operator has to take care of this. 4

2.4. Sensor installation The MPS 03.1 is installed at an appropriate point of the system. All specified pressure and volumeflow requirements have to be met. (see technical data, chapter 3.1). Insert the sensor in the system by using the 4 provided cylinder srews (DIN912 M12x150-8.8-Zn3) and two SAE-flange 1 ½ 3000 PSI (not included in the shipment). 2 1 Attention: Look to it, that the SAE-flange 1 ½ is using with the compatible counter flange! 1. MPS 03.1 + SAE-flange 1 ½ 2. MPS 03.1 + SAE-counter flange 1 ½ Connect the MPS 03.1 with the included sensor cable. 5

2.5. Electrical connection of the MPS 03.1 The MPS 03.1 can be coupled with every PLC that is equipped with 24 V capable digital input channels. The MPS 03.1 is equipped with an electrical standard connection M12. With the help of this it can be connected to the MPM 01 display unit or other examination devices. (see 3.2 Pin assignment) After connecting the MPS 03.1 and the power cable to your system, the sensor is ready for operation. 6

3. Appendix 3.1. Technical Data Detection limit: Limit of measurement: > 350 µm Fe max. 100 particles/ s Operating pressure: 20 bar / 290 psi Ambient temperature: - 40...+ 70 C / - 40...158 F Fluid temperature range: - 30*...+ 85 C / - 22...185 F Survival temperature range: - 40...+ 85 C / - 40...185 C Max. volume flow: Min. volume flow: Power supply: Ripple: Electrical power consumption: Analogue outputs: Max. electric current on analogue outputs: Fluids: Connection size: Mass: 320 l/min / 84,544 gal/ min 60 l/min / 15,852 gal/ min + 24 V DC < 300 mv pp max. 5 W 1 x Signal output (24 V impulses 7 ms) 1 x Diagnostic output (24 V DC, if no malfunctions) 10 ma Mineral oil based hydraulic- and lubricating fluids (see separate list of fluid compatibility 3.3). SAE Flansch 1 ½ 3000 PSI * The minimum flow rate has to be ensured! Note: The working temperature range of the MPS 03.1 depends also on the VT - behavior of the fluid. For applications with very high viscous fluids a regular operation of the sensor is only possible within a temperature range in which a sufficient oil flow (60 l/ min.) can be ensured! 3.2. Pin assignment 2 kg Pin 1 + 24 V DC Pin 2 Diagnostic Pin 3 Output Pin 4 GND Pin 5 --------------- 1 2 5 3 4 1 4 5 3 2 Cable colour (Connection cable): 1: brown (+ 24 V DC ) Power supply 2: white (+ 24 V DC, if no malfunctions) Diagnostic output 3: blue (+ 24 V DC impulses 7 ms) Output 4: black GND Ground Shield: GND 7

3.3. Application areas - Compatibility - Hydraulic oils H, HL, HLP, and HV - Gear oils C, CL, CLP - Motor oils, gas oils - MIL-H-5606 E - Vegetable oils (HTG, Triglyceride) - Synthetic ester (HEES) - Polyalphaolefin (PAO) - Polyglycol (PG) 3.4. Trouble shooting No settings of the MPS 03.1 are done by the operator. In case of malfunctions, please contact INTERNORMEN Technology GmbH. To check your warranty and to answer questions by phone we need the serial number and the date of purchase of the instrument. 3.5. Shipment/ spare parts Article No.: (1) Sensor MPS 03.1 333988 (2) Sensor cabel, L = 5 m 332597 (3) O-Ring 47,22 x 3,53, P70 305078 (4) Cylinder screw ISO 4762 M12 x 150-8.8-Zn3 (4 St.) 334614 (5) Instruction manual 8

North America HQ 70 Wood Ave., South, 2nd Floor Iselin, NJ 08830 Toll Free: (800) 656-3344 (North America Only) Voice: (732) 767-4200 China No. 3, Lane 280, Linhong Road Changning District, 200335 Shanghai, P.R. China Voice: +86-21-5200-0099 Singapore 4 Loyang Lane #04-01/02 Singapore 508914 Voice: +65-6825-1668 Europe/Africa/Middle East Friedensstraße 41 D-68804 Altlussheim, Germany Voice: +49-6205-2094-0 Auf der Heide 2 53947 Nettersheim, Germany Voice: +49-2486-809-0 An den Nahewiesen 24 55450 Langenlonsheim, Germany Voice: +49 6704 204-0 Brazil Av. Julia Gaioli, 474 Bonsucesso 07251-500 Guarulhos, Brazil Voice: +55 (11) 2465-8822 For more information, please e-mail us at filtrationinfo@eaton.com Visit us online eaton.com/filtration for a complete list of Eaton s filtration products. 2012 Eaton Corporation. All Rights Reserved. All trademarks and registered trademarks are the property of their respective owners. Litho USA. All information and recommendations appearing in this brochure concerning the use of products described herein are based on tests believed to be reliable. However, it is the user s responsibility to determine the suitability for his own use of such products. Since the actual use by others is beyond our control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or the results to be obtained. Eaton assumes no liability arising out of the use by others of such products. Nor is the information herein to be construed as absolutely complete, since additional information may be necessary or desirable when particular or exceptional conditions or circumstances exist or because of applicable laws or government regulations.