HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

Similar documents
ROUND STEEL POLE STRAIGHT

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances.

SQUARE STEEL POLE STRAIGHT

Square Straight Steel - 4 Bolt Base Light Poles


Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

Olivio Medio LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Single 180 Double 180 Triple. 180 Quad

New Product Release: October 2014 Boone Racks

Brackets and Tenons. Product Specifications. PB Series

Brackets and Tenons. Product Specifications. PB Series XA-TMDA8

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Olivio Grande LED Candelabra Pole Top

Notch Bollard LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: ft.

TO O L K IT. Public Bike Repair

Project: Type: Qty: QH2L. Series Optics Mounting Light Engine CCT Finish Voltage Option. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole.

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Olivio Grande LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

5G350 Nominal 33W 5G530 Nominal 48W 5G700 Nominal 64W 5G105 Nominal 97W 5G140 Nominal 126W K K. 1 DM or HL only. Cannot be combined.

Single 180 Double 180 Triple. 180 Quad. 110 Lewis Road, Wantirna South, VIC 3152

SIGNALS AND LIGHTING FIELD GUIDE

Metal Halide - Ceramic, Medium Base ED17. H050 50w H070 70w H w H w HPS - Medium Base ED17

EML17 LED. Munich Pendant. Ordering Guide: EML17 LED

Catalog Number LSBT. Example: LSBT6C8T5WD1-BZ QMB. Optics. Type II Type III Type IV Type IV Automotive Type V Medium Type V Wide T2 T3 T4 T4A T5M T5W

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Clio CBM1701C IP67 SUITABLE FOR WET LOCATIONS

300 Series Pin & Barrel Type Continuous Stainless Steel Hinges

CYCL E STAT IO N. High Capacity

SITE /ROADWAY OTS SERIES OTS Watt

Full Height Ladder Safety Gate

METALWORKS Wings Accent and Acoustical Clouds Installation Instructions

MAST ARMS & POLES. Ornamental Pole Top & Bases

S W E RV E RAC K. Simple Security. Simple Stability.

Arms & Poles Selection Guide

Super Shot Adjustable Basketball System

Swerve Rack CUSTOM RACKS AVAILABLE

Safe and secure Dero

Outdoor Water Solutions, Inc. 9 Backyard Windmill. Installation Manual

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

H O O P RAC K. Simple Security

Installation Instructions/Operation and Maintenance Manual. PS DOORS Contact Information. Website psdoors.com

OPTX PRECISION GUIDED LIGHTING TECHNOLOGY

Outdoor Water Solutions, Inc. Small Backyard Windmill. Installation Manual

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series

Next Level Security. This 2-tier locker ships flat to save on freight, comes in galvanized and powder coat finish options, and has a modular design.

Downtown Rack. Custom logo option available

AIR KIT 3. Heavy-Duty Public Bike Pump

Aluminum. Fence Systems

WeatherShield Covered Walkway and Connect-A-Building

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

Tenons Adaptors

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds

KIM LIGHTING ALTITUDE 2 1

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

Today s Service Station

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

The Saddle Rack. For Power And Communication Cables

4000 Watt - Metal Halide - Three Stage Light Tower - 30 Feet

Secure Bike Parking. Patent Pending Dero

Installation Instructions. Installation Type

Arms & Poles Selection Guide

KO LO SH E LT E R. High Capacity and Flexibility

ALUMINUM. Fence Systems. Made. in the USA

Beam Pattern. Lamping C K (coated lamp) NOL Lamp not included C737 NOL. Lamp not included K (clear lamp) NOL

AUXILIARY FRAMING AND ACCESSORIES

Inula Bollard LED Solar

Installation Instructions. Installation Type

DERO BIKE LOCKER 33. Maximum Security

PART MATERIALS. Section Fencing Materials. Description

F-4 FURNITURE. Contents

Installation Instructions

DETAILED ILLUSTRATION

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

London Bridge RC Lake Havasu, AZ. Tennis front cover

Horizontal Cable Systems

Bike Locker Model DBL1 & DBL2

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

ATI Evaluation Service A Division of Architectural Testing Certification Services

INSTALLATION INSTRUCTIONS

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

ARX25 Without Lens ArcheType X Site/Area kl_arx25_nolens_spec.pdf

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

_ PR020 Series. Lamping. Color. SA Stake Mount K NOL Lamp not included. Single Pole Top Double Pole Top Triple Pole Top Quad Pole Top

UPM 10X and 10XHD A. TEE SOCKET: 7 O.D. PIPE SOCKET TO FIT OVER 6 SCHEDULE 40 OR 80 STEEL PIPE

Optimast Installation Method Statement. F108.

Transcription:

Type: Job: Catalog number: Approvals: / / / / / / Pole Cat. No. Mounting Arm Drilling Pole Finish Optional Optional Pole Optional Duplex Option Base Cove Top Cap/Finial Receptical Specifications Conduit Opening Presswood Template Plan View 45 Longitudinal reference line. Orient parallel to curb or walkway. Leveling Nut and Washer Concrete footing to be designed (by others). See page 2 See page 3 See page 4 Bolt Circle Diameter Standard Era Anchor Bolt Projection Base Detail X2 X1 Grout must be packed under pole base to insure full contact with footing and prevent loosening of leveling nuts. Provide a channel through the grout for drainage from the pole interior. X Y2 Pole Step Y1 Hand Hole Standard Era Date: Page: 1 of 5 Pole Construction: Seamless round extruded aluminum tube of alloy 6063-T5, welded to top and bottom of aluminum base casting of alloy 356. : Two-piece, cast aluminum full cover, secured by stainless set screws. The standard base cover is the Era. Two optional base cover styles available. (See page 4) 1) HBC1 - Decorative smooth sided cast aluminum base cover. 2) HBC2 - Traditional fluted side cast aluminum base cover. Pole Cap: Flat cast aluminum provided for all side-mounted luminaires. Optional traditional style finial available. (See page 4) 1) HF1 - Dome style cast aluminum cap. 2) HF2 - Traditional style cast aluminum finial. Handhole: 18" above the base cover, with a gasketed cover and ground lug. Anchor Bolts: Four galvanized anchor bolts provided complete with eight nuts, eight flat washers, and a presswood template. Vibration Dampener: All poles 25' and above include an internally mounted, factory installed pendulum vibration dampener, with flush stainless steel socket head fasteners finished to match pole. Strength: Poles designed to withstand wind loads as listed in chart (See page 5 when luminaires are mounted per fixture installation instructions. Refer to specific Era Collection mounting arm for specific luminaire and arm EPA. Finish: Super TGIC thermoset polyester powder coat paint applied over a titanated zirconium conversion coating. Standard colors are Black, Dark Bronze, Light Gray, Graphite Platinum Silver, Titanium and White. Custom colors are available. CAUTION: Do not install poles without luminaires or strength guarantee is voided. Any unauthorized accessories secured to pole shall void strength guarantee. Maintenance: A regularly scheduled maintenance program must be established to insure the protective paint coating is intact, corrosion or structural damage has not occurred, and anchor bolt nuts are tight. Failure to do so could lead to pole collapse and serious personal injury. Certification: Certified UL 1598 in accordance with Article 410 of ANSI/NFPA 70, National Electrical Code.

Job: Page: 2 of 5 Standard Features NOTE: All allowable pole and fixture EPAs (Effective Projected Area, which is Fixture Area x Drag Factor) are derived from the AASHTO standard (American Association of State Highway and Transportation Officials). Responsibility lies with the specifier for correct pole selection based on local codes and standards for the job location (See page 5). X X2 Y2 Pole Step Pole v Pole Catalog Allowable Pole EPA Wind Map Steady Wind Number X X1 X2 Y1 Y2 85 100 110 120 130 150 l 10-534188 10' 6.5' 3.5' 5"x.188 3.375" 41.46 36.78 33.70 27.64 23.03 19.46 16.6214.34 l 12-534188 12' 8' 4' 5"x.188 3.375" 33.85 29.95 27.38 22.37 18.58 15.63 13.2911.42 l 14-534188 14' 9.3' 4.7' 5"x.188 3.375" 28.32 24.97 22.78 18.52 15.30 12.81 10.83 9.24 l 16-534188 16' 10.5' 5.5' 5"x.188 3.375" 24.09 21.16 19.24 15.55 12.77 10.61 8. 7.54 l 20-534188 19.5' 13' 6.4' 5"x.188 3.375" 17.48 15.22 13.74 10.96 8.88 7.26 5.99 4.97 l 14-64188 14' 9.3' 4.7' 6"x.188 4" 39.42 34.97 32.15 26.24 21.76 18.33 15.7013.59 l 16-64188 16' 10.5' 5.5' 6"x.188 4" 33.67 29.81 27.39 22.26 18.37 15.41 13.1711.36 l 20-64188 19.5' 13' 6.5' 6"x.188 4" 24.66 21.75 19.97 16.08 13.14 10.93 9.28 7.97 l 25-64188 25' 16.7' 8.3' 6"x.188 4" 16.82 14.65 13.42 10.56 8.39 6.81 5.70 4.81 l 25-64400 25' 16.7' 8.3' 6"x.400 4" 20.81 18.17 16.62 13.14 10.50 8.57 7.20 6.11 l 30-64188 30' 20' 10' 6"x.188 4" 11.68 10.01 9.15 6.94 5.28 4.11 3.34 2.73 l 30-64400 1 30' 20' 10' 6"x.400 4" 17.80 15.43 14.09 10.97 8.60 6. 5.74 4.81 1 Pole reinforced, to 40" above base, to.400", remaining section is.188" X1 Mounting Y1 Hand Hole Std Era Base Cover Anchor Base and Bolt Detail Bolt Anchor Anchor Pole Pole Circle Bolt Bolts Conduit Height Diameter DIA Projection Size Size Opening 10'-14' 5" 8K" 3J" L" x 15" + 3" 11.E" DIA 3" DIA 16'-20' 5" 8K" 3J" L" x 30" + 4" 11.E" DIA 3" DIA 14' 6" 10K" 3C" L" x 15" + 3" 14" DIA 5" DIA 16'-30' 6" 10K" 3C" L" x 30" + 4" 14" DIA 5" DIA Flush MountT Side Arm Plan Views: Mounting: l FM l A l SA l B l SB l L l SL l T l ST l Y l SY l C l SC NOTE: Allowable Pole EPA for jobsite wind conditions must be equal to or greater than fixture mount EPA. Please refer to Kim luminaire catalog for specific fixture. Available Arm Drilling Please see pole drilling requirements in specific Kim luminaire catalog. l HA02S l HA02L l HA11S l HA11L l HA12S l HA12L l HA13S l HA13L l HA14S l HA14L l HA31S l HA31L l HA32S l HA32L l HA33S l HA33L l HA34S l HA34L l HA35S l HA35L l HA36S l HA36L l HS37S l HA37L l 2 HA01S mounts to pole top O.D. of 3C" l 2 HA03S mounts to pole top O.D. of 3C" l 2 HA01L mounts to pole top O.D. of 4" l 2 HA03L mounts to pole top O.D. of 4" 2Pole will be shipped with internal pole adaptor installed. l HA38S l HA38L l NO OPTION

Job: Page: 3 of 5 Standard Features Finish TGIC powder coat paint over a titanated zirconium conversion coating. Color: Black Dark Bronze Light Gray Graphite Platinum Silver Titanium White Custom Color 1 Cat. No.: l BL l DB l LG l GT l PS l l TT l WH l CC 1 1 Custom color subject to additional charges, minimum quantities and extended lead times. Consult representative. Custom color description: Standard Era The standard Era is a heavy and durable cast aluminum component, configured in two halves for easy attachment after the pole is raised and set onto the anchor bolts. 5K" (139.7 mm) 11D" DIA. (295.3 mm) 13B" DIA. (333.4 mm) 6" (152.4 mm) 5" O.D. Poles 6" O.D. Poles Standard Flat Pole Cap The standard Flat Pole Cap is cast aluminum, secured by a single top screw activating an internal expansion clip. 3C" DIA. (85.85 mm) 4" DIA. (101.6 mm) F" (4.7 mm) F" (4.7 mm)

Job: Page: 4 of 5 Optional Features Optional Decorative Cat. No. l HBC1 The Decorative is constructed of heavy and durable cast aluminum, the base is supplied in two halves for easy attachment after the pole is raised and set onto the anchor bolts. 14B" DIA. (358.8 mm) 17B" DIA. (435.0 mm) 24" (609.6 mm) 4J" (108.0 mm) 28L" (730.3 mm) 5" (127.0 mm) 5" O.D. Poles 6" O.D. Poles Optional Traditional Cat. No. l HBC2 The Traditional is constructed of heavy and durable cast aluminum, supplied in two halves for easy attachment after the pole is raised and set onto the anchor bolts. 6I" (175.8 mm) 8C" (213.4 mm) 7J" (184.2 mm) 4L" (120.7 mm) 18J" DIA. (463.6 mm) 23" (584.2 mm) 9" (228.6 mm) 6" (152.4 mm) 22O" DIA. (579.1 mm) 28O" (579.1 mm) 5" O.D. Poles 6" O.D. Poles Optional Dome Pole Top Cap Cat. No. l HF1 Dome Pole Top Cap is cast aluminum, finished to match the pole, and available for 3.4" and 4" diameter pole tops.: 1D" (41.40 mm) 3C" DIA. (85.85 mm) 4" DIA. (101.6 mm) 2" (50.8 mm) Optional Traditional Pole Top Finial Cat. No. l HF2 Each finial is cast aluminum, and available for 3.4" and 4" diameter pole tops. 3O" (96.8 mm) 3C" (85.7 mm) 6I" (175.8 mm) 3E (97.8 mm) 4K" (114.3 mm) 4B" (104.7 mm) 8J" (209.6 mm) 4N" (115.8 mm) Optional Duplex Receptacle Cat. No. l DR l DR-GFI Mounted opposite the handhole, at 22K" above the base cover, in a cast aluminum box that is internally welded and sealed with a gasketed self-closing cover and locking bracket. Duplex Receptacle (DR) rated 20A., 125V. Duplex Receptacle with Ground Fault Circuit Interrupter (DR-GFI) rated 20A., 125V.

Job: Page: 5 of 5 85 100 110 120 130 130 Wind Map United States and Canada Special Wind Region (Consult Local Authorities) 150 To obtain more information on AASHTO Standards for Lighting Equipment contact: American Association of State Highway and Transportation Officials: 444 N. Capitol Street, NW, Suite 249 Washington, DC 20001 (202) 624-5800 www.aashto.org 100 130 110120 150 NOTES: Values are based on 50 year mean recurrence interval 30' above grade. Hawaii has an 105 mph wind velocity. Puerto Rico has a 125 mph wind velocity. Caution must be exercised in determining wind velocities in special wind areas such as: Mountainous Regions Areas surrounding the Great Lakes or other large bodies of water or open land. Areas subject to extreme wind conditions, such as hurricanes, typhoons, cyclones, and tornadoes. Areas adjacent to airports. Any specific area with a known or suspected abnormally high intermittent wind condition caused by geography, adjacent structures, or other specific local conditions that may not be recorded in National Weather Service records. Allowable pole EPA for jobsite wind conditions must be equal to or greater than fixture EPA. Responsibility lies with the specifier for correct pole selection based on AASHTO wind map and job location. The Wind Map is intended only as a general guide. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application. CAUTION: Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide. Consult AASHTO standards. Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or Tornadoes expose poles to flying debris, wind shear, and other unpredictable aerodynamic forces not indicated by the wind velocity ratings. Pole Strength Limited Warranty: Standard, unmodified Kim lighting Poles installed as recommended, undamaged by corrosion, or lack of maintenance, shall withstand steady wind conditions as provided on page 2 (Allowable Pole EPA). Installation of poles without luminaires, or attachment of any unauthorized accessories to poles shall void this warranty. Ref: AASHTO 2001