Test Report: SC-35BC 35W Single Output With Battery Charger(US Function) DESIGN ERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENIRONMENT TEST
35W Single Output With Battery Charger(US Function) SC-35series DESIGN ERIFY TEST OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 RILE & NOISE 1:240 mp-p (Max ) I/: 230AC 1: 30.8 mp-p (Max ) O/:FULL LOAD 2 OUTUT OLTAGE ADJUST RANGE CH1:24 ~ 29 I/: 230 AC I/: 115 AC O/:MIN LOAD 23.19 23.19 ~ ~ 29.84 29.84 / 230 AC / 115 AC 3 OUTUT OLTAGE TOLERANCE 1:1 %~ -1 % (Max) I/:90 AC / 264 AC O/:FULL/ MIN LOAD 1: -0.043 %~ 0.043 % 4 LINE REGULATION 1: 0.5 %~ -0.5 % (Max) I/:90AC ~ 264 AC O/:FULL LOAD 1: -0.022 %~ 0 % 5 LOAD REGULATION 1:0.5 %~ -0.5 % (Max) I/: 230 AC O/:FULL ~MIN LOAD 1: -0.043 %~ 0.043 % 6 SET U TIME 230AC: 800 ms (Max) I/: 230 AC 230AC/ 231.694 ms 115AC: 1600 ms(max) I/: 115 AC 115AC/ 236.531 ms O/:FULL LOAD 7 RISE TIME 230AC: 50 ms (Max) I/: 230 AC 230AC/ 6.512 ms 115AC: 50 ms (Max) I/: 115 AC 115AC/ 8.300 ms O/:FULL LOAD 8 HOLD U TIME 230AC: 50 ms (TY) I/: 230 AC 230AC/ 80.396 ms 115AC: 10 ms (TY) I/: 115 AC 115AC/ 17.329 ms O/:FULL LOAD 9 OER/UNDERSHOOT TEST < +5% I/: 230 AC O/:FULL LOAD 10 DYNAMIC LOAD 1: 2760 mp-p I/: 230 AC (1).O/:FULL /Min LOAD 90%DUTY/ 1KHZ (2).O/:FULL /Min LOAD 90%DUTY/ 3KHZ (3).O/:FULL /Min LOAD 90%DUTY/ 5KHZ (4).O/:FULL /Min LOAD 50%DUTY/ 120HZ (1)170 (2)64.0 (3)50.0 (4)220 TEST: <5 % mp-p mp-p mp-p mp-p Model: SC-35BC Test Report 2 / 7
35W Single Output With Battery Charger(US Function) SC-35series INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 INUT OLTAGE RANGE 90AC~264 AC I/:TESTING 2 INUT FREQUENCY RANGE 47HZ ~63 HZ O/:FULL LOAD I/: (1)LOW-LINE-3=87 HIGH-LINE+15%=300 O/:FULL/MIN LOAD ON: 30 Sec OFF: 30 Sec 10MIN (2)230ac ON: 0.5 Sec OFF: 0.5 Sec 20MIN (3)230ac ON:3Sec OFF:3Sec 12HOURS ( OWER ON/OFF ) I/: 90 AC ~ 264 AC O/:FULL~MIN LOAD 3 EFFICIENCY 86% (TY) I/: 230 AC O/:FULL LOAD TEST: (1)OK 71.012 ~264 (2)OK (3)OK TEST: OK 87.62 % 4 INUT CURRENT 230/ 0.5 A (TY) I/: 230 AC I = 0.314 A/ 230 AC 115/ 0.75 A (TY) I/: 115 AC I = 0.576 A/ 115 AC O/:FULL LOAD 5 INRUSH CURRENT 230/ 115/ COLD START 40 20 A (TY) A(TY) I/: 230 AC I/: 115 AC O/:FULL LOAD I = I = 28.343 13.992 A/ 230 AC A/ 115 AC 6 LEAKAGE CURRENT < 1 ma/240 AC I/: 264 AC O/:Min LOAD L-FG: 0.398 ma N-FG: 0.398 ma ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 BATTERY CUT OFF 20±1 I/: 230 AC O/:MIN LOAD 20.6/230AC 2 OER OLTAGE ROTECTION CH:28.98~39.5 I/: 230AC O/:MIN LOAD 35.5/ 230AC Shut down Re- power ON 3 OER LOAD ROTECTION 105 % ~ 150 % I/: 230 AC I/: 115 AC O/:TESTING 4 SHORT ROTECTION SHORT EERY OUTUT I/: 264 AC 1 HOUR O/:FULL LOAD 136.51 %/ 230 AC 129.23%/ 115 AC Hiccup Mode, recovers automatically after fault condition is removed Hiccup Mode, recovers automatically after fault condition is removed Model: SC-35BC Test Report 3 / 7
35W Single Output With Battery Charger(US Function) SC-35series CONTROL FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 AC OK TTLOENCOLLECTOROUTUT ON:AC OK I/: 230 AC O/:FULL LOAD AC OK:OK AC ICE:OK OFF:AC FAIL MAX RATING:50DC/30mA 2 BATTERY LOW TTLOENCOLLECTOROUTUT OFF :BATTERY OK ON :BATTERY LOW MAX RATING: 50DC/30mA BATTERY LOW OLTAGE:<22 I/: 230 AC O/:FULL LOAD BATTERY OK:OK BATTERY LOW:OK BATTERY LOW OLTAGE: 21.38 COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 WM Transistor ( D to S) or (C to E) eak oltage Q 1 Rated 2 Diode eak oltage D100 Rated : 5.5A/ 620 3 Input Capacitor oltage C5 Rated: : 68μ/ 400 : 20A/ 150 105 / Series 4 Control IC oltage Test WM IC U1 Rated : 28 (MIN.) I/:High-Line +3 =267 O/: (1)Full Load input on/off (2)Output Short (3) Dynamic Load 100% Load/ Min. Load 50%Duty/120Hz (4)full load continue I/:High-Line +3 =267 O/: (1)Full Load input on/off (2)Output Short (3) Dynamic Load 100% Load/ Min. Load 50%Duty/120Hz (4)full load continue I/:High-Line +3 =267 O/: (1)Full Load input on/off (2) Min load input on /Off (3)Full Load /Min load Change I/:High-Line +3 =267 O/: (1)Full Load input on/off (2) Min load input on /Off (3)Full Load /Min load Change (1)528 (2)494 (3)530 (4)518 D100: (1)123 (2)120 (3)123 (4)123 (1)374 (2)374 (3)374 (1)16.0 (2)16.0 (3)16.0 5 Clamp Diode eak oltage D1 Rated: 800 2 A I/:High-Line +3 =267 O/: (1)Full Load input on/off (2)Output Short (3) Dynamic Load 100% Load/ Min. Load 50%Duty/120Hz (4)full load continue (1) (2) (3) (4) 480 402 484 482 Model: SC-35BC Test Report 4 / 7
35W Single Output With Battery Charger(US Function) SC-35series SAFETY & E.M.C. TEST SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 WITHSTAND OLTAGE I/-O/: 3 KAC/min I/-O/: 3.6 KAC/min I/-O/: 2.247 ma I/-FG: 2 KAC/min I/-FG: 2.4KAC/min I/-FG: 2.395 ma O/-FG: 0.5 KAC/min O/-FG: 0.6 KAC/min O/-FG: 1.101 ma 2 ISOLATION RESISTANCE I/-O/:500DC>100MΩ I/-FG: 500DC>100MΩ O/-FG:500DC>100MΩ I/-O/: 500 DC I/-FG: 500 DC O/-FG: 500 DC /70%RH I/-O/: 2175 MΩ I/-FG: 1834 MΩ O/-FG: 3165 MΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min / 70%RH 4mΩ E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 HARMONIC EN61000-3-2 I/: 230 AC/50HZ ASS CLASS A O/:FULL LOAD 2 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8K / Contact:4K I/: 230 AC/50HZ O/:FULL LOAD CRITERIA A 3 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1K I/: 230 AC/50HZ O/:FULL LOAD CRITERIA A 4 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1K L,N-E:2K I/: 230 AC/50HZ O/:FULL LOAD CRITERIA A Test by certified Lab & Test Report repare Model: SC-35BC Test Report 5 / 7
35W Single Output With Battery Charger(US Function) SC-35series RELIABILITY TEST ENIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 TEMERATURE RISE TEST MODEL:SC-35AC 1. ROOM AMBIENT BURN-IN:1 HRS I/: 230AC O/: FULL LOAD Ta= 27.6 2. HIGH AMBIENT BURN-IN: 1 HRS I/: 230AC O/: FULL LOAD Ta=47.2 2 OER LOAD BURN-IN TEST 3 LOW TEMERATURE TURN ON TEST 1 HOUR ( MIN ) NO osition ROOM AMBIENT Ta=27.6 HIGH AMBIENT Ta=47.2 1 U1 68.2 86.7 2 U100 55.1 74.0 3 U200 61.7 80.7 4 C200 59.6 78.6 5 LF1 62.0 80.6 6 BD1 62.5 80.8 7 C5 57.7 76.6 8 D1 82.1 102.1 9 Q1 72.4 93.4 10 T1 86.8 105.4 11 D100 88.8 107.1 12 C105 68.4 88.0 13 D4 60.0 78.6 14 LF100 50.3 70.2 15 C36 66.7 85.6 I/: 230 AC O/:130 % LOAD TURN ON AFTER 2 HOUR I/: 264AC/100AC O/: 100 % LOAD Ta= -30 4 HIGH HUMIDITY HIGH TEMERATURE HIGH OLTAGE TURN ON TEST AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 AC O/:FULL LOAD Ta=50 HUMIDITY= 95 %R.H 5 TEMERATURE COEFFICIENT +0.03%/ (0~50 ) I/: 230 AC O/:FULL LOAD + 0%/ (0~50 ) 6 STORAGE TEMERATURE TEST 1. Thermal shock Temperature: -20 ~ +85 2. Temperature change rate :25 / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC OK 7 THERMAL SHOCK TEST 1. Thermal shock Temperature: -30 ~ +70 2. Temperature change rate :25 / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230AC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec OK Model: SC-35BC Test Report 6 / 7
35W Single Output With Battery Charger(US Function) SC-35series 8 IBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave 9 CAACITOR LIFE CYCLE (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle (4) Acceleration:2G (5) Test Time:60min in each axis (X.Y.Z) (6) SUOSE C105 IS THE MOST CRITICAL COMONENT (1) I/: 230AC O/:FULL LOAD Ta=25 LIFE TIME (2) I/: 230AC O/:FULL LOAD Ta=45 LIFE TIME (3) I/: 230AC O/:75% LOAD Ta=45 LIFE TIME (4) I/: 230AC O/:50% LOAD Ta=45 LIFE TIME 10 MTBF MIL-HDBK-217F TOTAL FAILURE RATE:658.4 KHRS (1) 146858HRS (2) 36666HRS (3) 83129HRS (4) 122608HRS 11 DMTBF/Accelerated Life Test Demonstration Mean Time Between Failure (Expected Life): Above 50,000 hours @ TA 50 SAMLE TESTER AROAL RODUCT SAMLE XUJIE wangdz 2007/3/20 A50-S014 Model: SC-35BC Test Report 7 / 7