Instruction Manual. Digital Panel Meter Model 3153B

Similar documents
Instruction Manual. Digital Meter Relay Model 4258 CAUTION

Universal Alarm Indicator

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

MODEL Digital Ohm Meter. Instruction Manual

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

AMM-1022 Digital Multimeter USER`S MANUAL

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition IM E

INSTRUCTION MANUAL DIGITAL MULTIMETER

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

DVM1190 DIGITAL MULTIMETER

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User s Manual Current Probe IM E. 8th Edition

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

312, 316, 318. Clamp Meter. Users Manual

User s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

MODEL: 47LV. Digital Panel Meters 47 Series

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

CCS Inc. (8) DIN Rail Bracket. 2-M3(inside 3mm max.) for Fixation

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

ATK Clamp Meter

GC83 Digital Indicators & GC93 Digital Meter Relay

User s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Multifunction AC/DC Voltage Tester

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

ET-3888 True RMS Clamp Meter. User Manual

VC835 DIGTAL MULTIMETER Operation Manual

Model UT511 OPERATING MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Sine Wave Power Inverter GD150/GD300 Series User s Manual

Pen-type DIGITAL MULTITESTER

ITP14. Universal process indicator. User guide

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

This section is specifically about safety matters

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Multifunction Digital

MODEL: M2DYS SEN TRONIC AG

30XR-A Professional Digital Multimeter Users Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User Guide. AC/DC Mini Clamp Meter. Model

AC/DC CLAMP METER USER S MANUAL

This section is specifically about safety matters

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications


MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

Model S-520 Coin Counter / Sorter Operating Manual

User s Manual Current Probe IM E. 6th Edition

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

ProfiScale MULTI Multimeter

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

USER'S MANUAL DMR-6700

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

S5-ADU. Front... 4 Rear... 4

UT207A/208A/209A Operating Manual. Table of Contents

Hawk 3 Digital Panel Meter / Controller

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Contents. 1. Safety Description Specifications Operation Instructions Battery Replacement...20.

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

True RMS AC / DC Power Clamp Meter Model

User Guide. Digital AC/DC Clamp Meter Model 38394

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

Pocket Size Digital Multimeter with USB Model: A & A

IP Series DUAL POWER AMPLIFIERS

RT-3 UNIT RELAY 4-POINT TERMINAL

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

Instruction Manual for Digital Grounding Resistance Meter

User s Guide. Digital AC/DC Clamp Meter Model 38394

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

BENNING. CM7 Electrical Tester. Service Information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

OPERATOR S INSTRUCTION MANUAL

RP1003C/RP1004C/RP1005C

Solid-state Twin Timer

Digital Multimeter with Backlight

DIGITAL MULTIMETER AX-588B

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

INFRARED WIRELESS DISTRIBUTOR

Transcription:

Instruction Manual Digital Panel Meter I-01999 1. Preface Please take care that this instruction manual is certainly delivered to the person in charge of operating this instrument. For safe use of this product, please observe the following warning and caution. In order to help the users safe use of the products, the following symbol marks are used in this manual. WARNING CAUTION This is the warning to avoid the danger when it is assumed that such danger as may cause fatal accident or severe injure to a user occurs in case that the product is mishandled. This is the caution to avoid the danger when it is assumed that such danger as may cause minor injure to a user or generate only physical obstacle occurs in case that the product is mishandled. WARNING There is no power on-off switch on the model 3153B. It immediately starts to operate after turning the power. Do not touch terminals when turning the power on. CAUTION Preserve followings for your safety. The rated data is, however, defines with more than 15 minutes warming-up times. When the product is installed in the cabinet, perform the appropriate heat radiation to keep less than 50 o C in it. Avoid the close-contacted mounting of the meter. The rise of internal temperature affects the life of product. Do not install under the following conditions. Where it is exposed to direct sunlight, dust, corrosive gases, rain, etc. Where ambient temperature or humidity is high. Where it is exposed to excessive noise or static electricity. Where there is constant vibration or shock Store the instrument within the specified temperature range for storage (-20~70 o C). When the front panel or the case becomes dirty, wipe it with soft cloth. For heavy dirt, wipe it lightly with the soft cloth wetted with the neutral cleaner thinned by water, and finish the cleaning with dry cloth. Do not use organic solvent like benzene or paint thinner as they may deform or discolor the case. TSURUGA ELECTRIC CORPORATION 1

2. Specifications 2.1 Specifications for installation Power supply : AC100V~AC240V 50/60Hz Tolerance of source power voltage : AC90~250V Power consumption : Approximately 4VA at AC100V supply, approximately 5VA at AC200V supply. Operating ambient temperature : 0~50 o C Storage temperature : -20~70 o C Weight : Approximately 900g Mounting method : From the product s rear side, by dedicated bracket. 2.2 General specifications Display Decimal point Over range indication : -9999~9999, red or green LED, character height 45mm, with zero-suppress function. : Arbitrarily settable from the terminal blocks. : When exceeded 100% or 130%, indicated with. When exceeded -100% or -130%, indicated with. 100% or 130% is selectable by the panel front switch. Display scaling : Full sale display -9999~9999 Offset display -9999~9999 Resolution : 1/10000 Power source line interfusing noise : 1000V Insulation Resistance : DC500V 100MΩ or more Withstanding Voltage : Input terminals - Case AC1500V for 1 min. Power supply terminals - Case AC1500V for 1 min. Power supply terminals - Input terminals AC1500V for 1 min. Protection degree : Front side IP40, back side IP20 Unit indication : Designated character is adhered at the right bottom of the front mask. (It has to be designated at the time of ordering.) 3. Name of parts 3.1 Exterior 3.2 Inside front mask Polarity LED DP3 DP2 DP1 Front kw Unit label Fuse switch Rear switch switch Terminal blocks 2 TSURUGA ELECTRIC CORPORATION

4. Wiring 4.1 Terminal arrangement Terminal name Function INHi INLo P B HOLD COM DP1 DP2 DP3 NC GND P2 P1 1 2 3 4 5 6 7 8 9 10 11 12 Input Peak / 10 1 10 2 10 3 Hold Common bottom Decimal point - Ground Power source Terminal screws: M3 Fastening torque: 0.46~0.62N m Crimp terminal: As shown on the right. 4.2 Cautions for wiring 5.3min. φ3.2min. 4.4max. 6max. WARNING To avoid an electrical shock, turn the power off when wiring. Do not wire with moistened hands. Locate away from the wet place. Do not touch terminals when turning the power on. CAUTION Apply the source power voltage and the load within the rated values. Otherwise, it may damage the product. Apply the supply voltage so that it can reach the rated value within one second. When the power to the product is turned OFF and ON again, provide the downtime of about 10 seconds. Do not use the product with wrong wiring, which may cause the breakdown of the product. Other cautions for wiring Be sure to wire the input line and source power line independently with each other. If they are wired in parallel, it may case an unstable display. In case that the noise is frequently occurred, it will be effective to store the product in the shielded housing or to insert the power source line filter or insulated transformer. P B, HOLD, COM, DP1~3 terminal blocks are not isolated from the input, so in case that each functional terminal is controlled, it is recommended to make the isolation by photo-coupler, relay and so on. Also, when a number of the product are controlled at a time, make the isolation for each product. +5V IN Lo 3153B 1mA or less HOLD COM Switch Photo-coupler 4.3 Explanation of terminal blocks Input terminals (INHi INLo) Connect the measurement input with correct polarity. Connect the measurement input of higher polarity to Hi. Be sure to wire the input line and source power line independently with each other. If they are wired in parallel, it may case an unstable display. Peak/Bottom terminals (P B) By connecting the peak or bottom terminal to common terminal (COM), the maximum or minimum value can be displayed. The selection of maximum or minimum value can be made by the panel front switch. Active L I IL -1mA, L =0~1.5V, H =3.5~5V Hold (HOLD) The displayed value can be held by connecting the hold terminal (HOLD) to common terminal (COM). Active L I IL -1mA, L =0~1.5V, H =3.5~5V Decimal point (DP1~DP3) The decimal point can be set to the arbitrary position by short-circuiting the terminal of 10 1 ~10 3 digit to common (COM). Active L I IL -1mA, L =0~1.5V, H =3.5~5V Common (COM) It is the common for peak-bottom, hold and decimal point. Power supply (P1, P2) Apply the source power supply within the rated range AC90~250V. TSURUGA ELECTRIC CORPORATION 3

5. Explanation of function Each following function can be set by the panel front switch: Offset : Display of the offset value of the scaling can be arbitrarily set. Full scale : Display of the full scale of the scaling can be arbitrarily set. Over-range indication : Trigger of over-range indication is selectable from 100% or 130% of the input. When exceeded 100% or 130%, indicated with. When exceeded -100% or -130%, indicated with. Display cycle : Display cycle can be changed. SP1: 67ms, SP2: 400ms, SP3: 1s, SP4: 2s, SP5: 3s, SP6: 4s, SP7: 5s (During the moving average, it is SPM: 67ms.) Average calculation : Divisional averaging or moving average, and the numbers of samples for averaging can be selected. OFF : No moving averaging ON : Divisional averaging Numbers of sample for averaging, 2, 4, 8, 16, 32 Offset fixation : The display for the value less than the offset value can be set to display the offset value. When the scaling is set to 4~20mA=0~1000, the input less than 4mA is fixed to display 0. 10 0 digit turn out : The display of 10 0 digit is compulsorily turn out. Peak / Bottom change-over : Function of the terminal block P/B can be changed to maximum or minimum value display. 6. Setting 6.1 Function of panel front switch switch : In measurement mode, it switches over to the setting mode. In setting mode, it switches over to the measurement mode. switch : In setting mode, it selects the digit of value to set, displays the content switch of setting and switches over to the adjustment mode. : In setting mode, it changes the set value and selects the content to set. - screwdriver How to remove the front mask Insert a - screwdriver in between the front frame and front mask and wrench it. 6.2 How to set In measurement mode, a press of switch for one second changes the mode to setting mode. 1Offset 2Full scale In measurement mode For about 1 sec. 3Over-range indication 4Display cycle 5Average calculation 6Offset fixation 710 0 digit turn out 8Peak/bottom change-over Returns to 1 1st: Highest digit blinks. 2nd and after: Digit selection 1st: Highest digit blinks. 2nd and after: Digit selection Blinking digit count up Blinking digit count up Returns to 1 Returns to 2 Returns to 3 Returns to 4 1 Returns to 5 Returns to 6 Returns to 7 Returns to 8 Memorizes in EEPROM and returns to measurement mode. Action of switch during the setting of offset and full scale value. 10 3 digit : 1 2 3 8 9-9 -8-2 -1-0 0 Other digit : 1 2 3 8 9 0 1 2 is blank display. When there is no switch operation for 5 minutes in setting mode, the meter automatically returns to measurement mode, without memorizing any content of setting having been done. 1 When the averaging calculation is made by moving average, the display cycle can not be changed. 4 TSURUGA ELECTRIC CORPORATION

6.3 Default setting at delivery from factory Function Setting Offset 0000 Full scale 9999 Over-range indication 130% Display cycle 400ms Average calculation Divisional averaging ON Offset fixation OFF 10 0 digit turn-off OFF Peak/Bottom change-over Peak 6.4 Adjustment method A fine adjustment of the display is possible. In measurement mode, keep pressing the key, then the display changes to and the meter enters in adjustment mode. ZERO adjustment In measurement mode About 3 sec. About 1 sec. MAX adjustment Input MAX value Input ZERO value (1V for 1~5V, 4mA for 4~20mA) DP0, DP1 lit up switch :Count down switch :Count up about 1 sec. DP2, DP3 lit up switch :Count down switch :Count up Memorizes in EEPROM and Returns to 1 returns to measurement mode. 6.5 Error message Adjustable range is about 5%. Display Cause Action to take When, in setting mode, the average Change the setting of average calculation is set to the moving average, calculation either to OFF or the set content for the display cycle is divisional averaging ON. indicated as If the switch is pressed at this time, the error indication is given. 6.6 LED display 0 1 2 3 4 5 6 7 8 9 Minus DP A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 7. Dimension 192 10 120 (12) 96 91.5 kw Unit:mm 186.9 TSURUGA ELECTRIC CORPORATION 5

8. Installation Panel Remove the metal bracket on both sides of the meter, insert it from the front and fix it. Rear panel Mounting pitch 15mm min210 min110 Panel cut-out dimension: 188 +0.8 / 0 92 +0.8 / 0 mm Allowable panel thickness: 1.0 ~ 6mm Note: Recommended thickness for the panel of aluminum is 1.5mm or more to avoid deformation of the panel. Optimum torque of fixing screws: 0.25 ~ 0.39N m 9. Model designation 3153B - -A- 1 2 3 1: Measuring input 2: Power supply voltage 3: Display color 1 Measuring Input Code Measuring range Input resistance Accuracy Overload 02 ±99.99mV 100MΩ ±(0.05% of rdg. + 1 digit) DC±250V 03 ±999.9mV 10MΩ ±(0.05% of rdg. + 1 digit) DC±250V 04 ±9.999V 10MΩ ±(0.1% of rdg. + 1 digit) DC±250V 05 ±99.99V 10MΩ ±(0.1% of rdg. + 1 digit) DC±500V 09 1~5V 1MΩ ±(0.1% of rdg. + 1 digit) DC±250V 13 ±999.9μA 100Ω ±(0.1% of rdg. + 1 digit) DC±50mA 14 ±9.999mA 10Ω ±(0.1% of rdg. + 1 digit) DC±150mA 15 ±99.99mA 1Ω ±(0.1% of rdg. + 1 digit) DC±500mA 16 ±999.9mA 0.1Ω ±(0.1% of rdg. + 1 digit) DC±2A 19 4~20mA 12.5Ω ±(0.1% of rdg. + 1 digit) DC±150mA Accuracy : Defined in the condition of 23 o C±5 o C, 45~75%RH. Temperature coefficient : ±150ppm/ o C, defined at the operating temperature 0~50 o C. 2 Power supply voltage 3 Display color Code Power source voltage Code Specification A AC100~240V R Red LED G Green LED Contact Information Name : Tsuruga Electric Corporation Address : 1-3-23 Minami-Sumiyoshi, Sumiyoshi-ku, Osaka-shi 558-0041 Japan 6 TSURUGA ELECTRIC CORPORATION