U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Similar documents
U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2750A/51A/52A InfiniiMode Differential Active Probes

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

N9051A Pulse Measurement Software

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Evaluating Oscilloscopes for Low-Power Measurements

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Agilent NFA Noise Figure Analyzer

InfiniiMax III probing system

Essential Capabilities of EMI Receivers. Application Note

Agilent NFA Noise Figure Analyzer

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment


MXG X-Series Signal Generator N5183B Microwave Analog

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Agilent InfiniiMax III probing system

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Agilent U9391C/F/G Comb Generators

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Solar Array Simulation System Integration

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight Technologies MATLAB Data Analysis Software Packages

How Offset, Dynamic Range and Compression Affect Measurements

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Agilent U1730C Series Handheld LCR Meters

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Agilent 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Phase Noise X-Series Measurement Application

Agilent First-generation MXG Signal Generators

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight U1882B Measurement Application for Infiniium Oscilloscopes

Today most of engineers use oscilloscope as the preferred measurement tool of choice when it comes to debugging and analyzing switching power

Keysight Technologies Alliance for Wireless Power (A4WP) Measurements Using an Oscilloscope (Part 3)

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Agilent 8761A/B Microwave Switches

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Evaluating Oscilloscope Bandwidths for your Application

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Agilent 8762F Coaxial Switch 75 ohm

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Keysight Technologies

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Agilent N9320B RF Spectrum Analyzer

Solutions for Solar Cell and Module Testing

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Introduction. Part 1. Introduction...2

Agilent Nonlinear Vector Network Analyzer (NVNA)

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Agilent N4916B De-emphasis Signal Converter

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Advanced Power Measurement and Analysis 5 Series MSO Option 5-PWR Datasheet

MXG Analog Signal Generator Express Configurations

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Transcription:

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes Data Sheet Fast, automatic and reliable characterization of switching mode power devices

Today s power supply designers are facing an increasing number of constraints in the development of high-efficiency, low-cost power supplies. Cost-effective solutions used to be the designer s key target. Today, rising energy costs bring power supply efficiency to the forefront. Additionally, other constraints such as design compactness, migration to digital control, tighter voltage tolerances, and regulations for power quality and EMI force the need for quick and reliable power supply testing. Increasing design constraints translate into more time dedicated to power device measurement and analysis for today s power supply designers. In spite of the increasing analysis capability offered by many oscilloscopes over recent years, it is not uncommon to see designers perform measurements and characterization manually. These measurements typically take a considerable amount of time to capture, analyze, and report. Figure 1. Power measurement application running on an Agilent 8000 Series oscilloscope provides a single-box solution for testing switching mode power supply characteristics 2

Full-featured measurements and automatic reporting of switching mode power supply (SMPS) characteristics Now you can skip the time consuming manual measurements when you are characterizing your power devices. The U1881A and U1882A power measurement application for Agilent oscilloscopes provides a full suite of power measurements that run directly on an Infiniium 8000, 9000A and 9000 H-Series oscilloscope or on a separate PC for use with InfiniiVision 3000 X-Series and 7000 Series oscilloscopes. Agilent s power measurement application offers seven modules to help you characterize your devices (power device analysis, input line analysis, output analysis, turn on/off analysis, transient analysis, modulation analysis) in addition to deskew and report generation. Each module contains relevant measurement and setup selections for easy repeatability. Modules Deskew Power device analysis Input line analysis Inrush current analysis Output analysis Turn on/off analysis Transient analysis Modulation analysis Report generation Measurements Automatic deskew for voltage and current probes Switching loss Safe operating area (SOA) with SOA mask editing Dynamic ON resistance di/dt dv/dt Power factor (real power/apparent power) Real power Apparent power Reactive power Crest factor Precompliance test to IEC61000-3-2 std A, B, C, D and RTCA DO-160E Inrush current Output voltage ripple Turn on time Turn off time Transient load response Pulse width versus time plot Duty cycle versus time plot Period versus time plot Frequency versus time plot Report generation 3

Auto deskewing and U1880A deskew fixture A power measurement is simply a point-by-point multiplication of the voltage and current waveforms measured by the voltage and current probes. To make accurate power measurement and calculation, it is extremely important to equalize the time delay between the voltage and current probes using a procedure known as deskewing. This step is critically important since a small offset in the timing of the voltage and current traces can cause a large error in the instantaneous power reading. To deskew a pair of probes, drive both voltage and current probes with the same pulse signal using the U1880A deskew fixture. With only a single click on the menu, deskewing is automatically performed and its values are saved in the power measurement software, so the next time you launch the power measurement application, you can use the saved deskew values or perform the deskewing again. The deskew accuracy is a function of the electrical characteristics of the voltage and current probes as well as the risetime of the signal under test. In general, higher bandwidth probes will allow for better risetime fidelity and better deskew resolution. Agilent's N2790A to N2793A differential probes are recommended for most applications. The U1880A deskew fixture is recommended for use with the following voltage and current probe combinations given various test signal risetime characteristics. Figure 2. Deskew dialog Figure 3. Deskew fixture 4

Power device analysis The switching loss in a power supply determines its efficiency. You can easily characterize instantaneous power loss and conduction power loss at the switching device over a designated switching cycle. The dynamic ON resistance measurement shows you power loss while the power transistor is conducting. To determine the reliability of the power supply it is very important to measure the power loss during dynamic load changes and to observe the SOA (safe operating area) plot. Using deep acquisition memory on the scope with the SOA plot, you can easily identify improper power transistor behavior. Figure 4. Power device analysis results are displayed both graphically and in a tabular, "lister" format Input line analysis Power supply designers need to characterize the line power for power quality, harmonics and conducted emissions under different operating conditions of the power supply. Some of the implicit measurements are real power, apparent power, reactive power, power and crest factor, and graphical display of harmonics with respect to standards such as IEC 61000-3-2 (Class A, B, C, D) and RTCA DO 160E. By using a current probe and the power measurement software (equipped with an FFT math function), you can measure conducted power line harmonics. Figure 5. Input line analysis results 5

Modulation analysis Modulation analysis allows you to quickly see the on-time and off-time information of the PWM signal, which is difficult to visualize because the information bandwidth is much lower than the pulse switching frequency. Plotting the embedded variation of on time or off time in the PWM signal over a long period of time can reveal the control loop response of the feedback loop system. This measurement performs data trending on the switching variation of the acquired waveform in the following formats: Frequency versus time Period versus time Duty cycle versus time Positive pulse width versus time Figure 6. Modulation analysis results Output analysis This module includes characterizing the ripple (either AC or switching) component in the output DC voltage. Ripple is the residual AC component that is superimposed on the DC output of a power supply. Line frequency and switching frequency can contribute to the ripple. This measurement presents the peak to-peak ripple value as well as the frequency response of the captured signal. Figure 7. Output analysis results 6

Turn on/off time analysis This module measures the time taken to get to the steady output voltage of the power supply after the input voltage is applied (turn on time) and for the output voltage of the power supply to turn off after the input voltage is removed (turn off time). Figure 8. Turn on/off analysis results Transient response analysis Power supplies are subject to transient conditions, such as turn-on and turn-off transients, as well as sudden changes in output load and line input voltage. These conditions lead to one of the key specifications of the power supplies: load transient response. This module measures the load transient response of the DC output; namely, the time taken for the DC output to stabilize during a load change. Figure 9. Transient response results 7

Report generation After a single test or a test module has been run, the View Report tab populates with measurement data and graphs for your archival and date sharing purposes. Reports are saved in a.htm format. Each report contains an up-front summary of pertinent test information. Reports are automatically saved to a test folder on the directory of your choice. Figure 10. Automatic report generation makes test result archival easy. 8

Ordering information Product number U1881A Option 001 Option 002 Option 003 U1882A Option 001 Option 002 U1880A Description Power measurement application for InfiniiVision 3000 X-Series and 7000 Series oscilloscopes 7000 Series oscilloscope-locked license (most common license type) (connect with 1 of any number of PCs) PC-locked license (connect this PC to one of many 3000 X-Series or 7000 Series scopes) 3000 X-Series oscilloscope locked license Power measurement application for Infiniium 8000, 9000A and 9000 H-Series oscilloscopes Oscilloscope-locked license (most common license type) PC-locked license (not common for Windows -based Infiniium scopes) Deskew fixture Recommended probes and accessories U1880A AC/DC current probes (one or more of these Agilent current probes) Differential probes (one or more of these Agilent differential probes) Passive probe (for measuring output noise) Deskew fixture for voltage and current probe deskewing 1147B 50-MHz, 15-A current probe with AutoProbe interface N2780A 2-MHz, 500-A current probe (requires N2779A power supply) N2781A 10-MHz, 150-A current probe (requires N2779A power supply) N2782A 50-MHz, 30-A current probe (requires N2779A power supply) N2783A 100-MHz, 30-A current probe (requires N2779A power supply) N2790A 100-MHz differential probe with AutoProbe interface (±1.4 kv differential) N2791A 25-MHz differential probe (±700 V differential) N2792A 200-MHz differential probe (±20V differential) N2793A 800-MHz differential probe (±15V differential) 1162A 1:1, 25-MHz passive probe N2870A 1:1, 35-MHz passive probe Related literature Product Web site Publication title Publication type Publication number InifniiVision 3000 X-Series Oscilloscopes Data Sheet 5990-6619EN InifniiVision 7000 Series Oscilloscopes Data Sheet 5990-4769EN Infiniium 9000 Series Oscilloscopes Data Sheet 5990-3746EN Infiniium 9000 H-Series Oscilloscopes Data Sheet 5991-1520EN Oscilloscope Probes and Accessories Selection Guide 5989-6162EN For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scopes 9

Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz Industry leading specs Powerful applications 10

www.agilent.com www.agilent.com/find/scopes myagilent myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: October 11, 2012 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011-2013 Printed in USA, January 11, 2013 5989-7835EN