inc Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Channel 2 Temperature Transmitter Black (V-) Green (V-)

Similar documents
Isolated STs Series, 4-20 ma Dissolved Oxygen and Temperature transmitter for in-line or submersible applications Insertion (in-line)

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

ph or ORP Transmitter

Bulb ph and ORP Electrodes

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Non-Submersible Industrial Pressure Transducer

Model Q40CT. System Features. Toroidal Conductivity Monitor...

TECHNICAL DATA ELECTRO CHEMISTRY DIFFERENTIAL PH AND ORP. phd sc Digital Diferrential PH and ORP Sensors

Series 7777 Meredian II Electrode In-Line or Immersion Mounting

Digital conductivity transmitter

RH/RHT Series. Relative Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. Features

Signet 9950 Dual Channel Transmitter

Signet 2750 DryLoc ph/orp Sensor Electronics

ORP100 Sensor. Edition 1.0. User Manual

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Signet 9950 Dual Channel Transmitter

Signet ph/orp Electrodes

WM1, WIND, W400, W100, W600: ORP Sensor Troubleshooting Guide (Electrode and Housing)

DissolvedOxygenMonitor

ANALYTICAL - COMPLEXITY MADE SIMPLE

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Signet ph/orp Electrodes General Purpose

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

Signet 9900 Transmitter

IXIAN-ORP ORP. Reads mV mV. Range. +/ 1mV. Accuracy. Calibration. Single point remotely through PLC or directly on board

Signet 9900 Transmitter

GCS20K. Conductivity Switch FEATURES

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

User s Guide TX93A. (J, K, T, E) 4-20 ma Ultra-Miniature Temperature Transmitters. Shop online at omega.com

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital inductive conductivity transmitter

Parts Per Million Dissolved Oxygen Systems

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Conductivity Transmitter

Materials (other materials see WIKA diaphragm seal program) Model S-10

Process ph/orp Analysis Systems

10 mv/g, 1 to 7k Hz top connector side connector Ceramic shear. Ceramic shear 352C34. Ceramic shear 353B34. Quartz shear 356A16

General Purpose Toroidal Conductivity Sensors

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

4-20 ma Vibration Transmitter, Top connector

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

ABB ph/orp analyzer and probe package

Analytical Transmitters

STANDARD RTD's INDEX

User s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Magnetic Flowmeter Systems

FIELD DEVICES PRESSURE

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

ph / ORP Measurement mypro CPM 431

2-wire level transmitter

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

Model Sono-Trak Transit Time

Industrial Systems Design & Implementation

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

RCM DIRECT READING FLOWMETER

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Signet 9900 Transmitter

Ultrasonic level meters ULM 70

Telemetrie-Messtechnik Schnorrenberg

LST400 Ultrasonic level / open channel flow transmitter

LST100 Ultrasonic level transmitter for upstream oil and gas

ED701 General Industry Pressure Transmitter

Key Number I II III IV V _ - - _ - - _ - _, _,

Electromagnetic Flow Transmitter

User s Guide TX92A. Miniature Temperature Transmitters. Shop online at omega.com

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

5790A Automated AC Measurement Standard

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

PSI Temperature Scanners

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Digital ORP sensor for the water and wastewater industry

Miniature Temptran RTD Transmitters

Sensors for Research & Development and Machinery Health Monitoring

General Specification

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

General Purpose Toroidal Conductivity Sensors

User s Guide EWS-BP-A. Barometric Pressure Transmitter. Shop online at omega.com

HIGH RESISTANCE MEASUREMENT ACCESSORIES

Telemetrie-Messtechnik Schnorrenberg

OPTISENS ORP 8590 Technical Datasheet

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Measuring and Controlling Unit Multronic

Measuring and Controlling Unit Multronic OC

The transducer component converts the measured signal and displays the actual value.

Memosens CPS96D. Technical Information

W100/W600/W900 Controller ph Electrode Troubleshooting Guide

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Humidity Sensor/Transmitter Assembly

Princo MagneLevel Model LML

Transcription:

phiconntm, phikliptm, and sensorloggertm are trademarks of phionics Inc.. The phiconntm connector system and the phikliptm array system are covered by U.S. Patent Nos. 6,331,117, 6,612,848, 6,824,394, 6,834,560, 6,993,998, and 7,293,746. Copyright phionics 2013. www.phionics.com Isolated STs Series, 4-20 ma ORP (redox) and Temperature transmitter for in-line or submersible applications Interchangeable Cable Optional titanium housing and/or food-grade FEP cables Isolated, true 2-wire ORP and temperature transmitter no ground-loops. Insertion (in-line) Replaceable Sensor 3 year typical life Removable guard for easy cleaning Submersion

Product Description The STs series of submersible water quality transmitters have an integrated preamp and an isolated 'true 2- wire', 4-20 ma transmitter. Two independent channels simultaneously transmit an ORP (oxidationreduction potential -- redox) and temperature signal -- two wires for ORP (redox) and two wires for temperature. The compact design afforded by the patented phiconn (TM) keyless connection system -- and the 316SS (titanium optional) and Delrin construction -- make the rugged sensor/transmitter ideal for applications such as process control, data acquisition, wastewater treatment, and, groundwater monitoring, The units can be submersed to 200 feet (approximately 100 psi). Individual units can be combined to make redundant or multiparameter modules using the phionics' patented phiklip (TM) array system. The phiklip (TM) system also allows for the units to be used in in-line (insertion) applications without fear of blow-out. As with all phionics' designs, the sensor/transmitters are designed with 'ease of service' as a primary goal. The 'true 2-wire', 4-20 ma STs series sensor/transmitters send a current proportional to the parameter being measured on the same two wires that provide the power (7 to 40 volts dc). Current transmission allows for long runs of inexpensive cable or wire (up to three miles) that is virtually noise-free without any signal loss that is common to voltage (IR drop) or digital (capacitance affecting 'rise/fall' timing). The seven volt operation allows the units to be powered by 12 volt battery systems with 5 volts of compliance, making them compatible with RTU's and solar powered applications. The units are intended for calibration via software supplied with the datalogger, PLC, or through the DCS. The ORP (redox) signal is on Channel 1. Channel 2 is the temperature channel of the transmitter, which provides an independent, isolated, 4-20 ma output proportional to a 0 to 50 Celsius range. The auto-polarity correction feature directs the applied supply voltage to allow for proper operation regardless of wire hookup. The Red and Black wires are for channel 1 -- ORP (redox), and the White and Green wires are for channel 2 - - temperature. The sensor cartridge has a large platinum band, that is easily cleaned, and a double-junction, gel-filled reference system that combines for accurate and long life in tough process applications -- as well as simple groundwater monitoring applications. The cartridge can be replaced in 15 seconds -- further reducing costs. Red ( V+ ) Black (V-) White ( V+ ) Green (V-) Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Input/ Output Preamp and Conditioning Channel 2 Temperature Transmitter Input/ Output Preamp and Conditioning Temperature Sensor Sensing Electrode

121.61mm 6.35mm 129.54mm cbs025p Specifications: Series STs Channel 1, ORP (redox) transmitter hsgs 7.62 meters (25 feet) standard cable length 362 mm (14.25 ) ORP sensing range 0 to +1000 mv (custom ranges available 0 to -1000mv, -500 to +500 mv, -1000 to +1000 mv, etc.) Output Current 4 to 20 ma, true 2-wire Power supply voltage 7 to 40 vdc 600 vdc, >70 db at 50/60 hz Linearity (of electronics) ± 4 mv Accuracy ± 4 mv Sensitivity ± 1 mv Stability ± 2 mv Repeatability ± 10 mv Electrode type Platinum, double junction Response time (luding electrodes) 95% < 20 seconds Temperature compensation none Pressure 0-100 psi Humidity 0-100% Wetted materials 316 ss, PVDF or Delrin, Viton, glass, titanium optional Length 362 mm (14.25 in.) Diameter 19 mm (0.750 in.) maximum Weight (excluding cable) < 0.22 kg (0.5 lb.) Cable type Removeable, shielded polyurethane, water-blocked Kevlar reinforced, 1.36 kg/100 feet Cable length (standard) 7.6 meters (25 feet) Cable from transmitter to power supply 4 conductor, twisted pair, 3 mile maximum ORP channel wire colors Red (+), Black (-) Channel 2, temperature transmitter Range Output Current Linearity Accuracy Power supply voltage Cable from transmitter to power supply 0 0-50 C 4 to 20 ma, true 2-wire 0 ± 0.5 C 0 ± 1 C 7 to 36 vdc 600 vdc, >70 db at 50/60 hz 4 conductor, twisted pair, 3 mile maximum Temperature channel wire colors White (+), Green (-) Viton, Teflon, Kevlar, Delrin, and Kynar are registered trademarks of the DuPont company sbd100 grd100 scs2010 19 mm (0.750 ) DIA 2013 Inc. All rights reserved. www.phionics.com

Wiring diagram for 4-20 ma current output water quality transmitters DC Power Supply 8 to 40 vdc V (+) V ( ) DC Power Supply 8 to 40 vdc { { V (+) V ( ) PLC, Datalogger, Display,or other loop-powered device i out ( ) i in (+) Optional resistor for converting current to a voltage. PLC, Datalogger, Display,or other loop-powered device i out ( ) i in (+) Optional resistor for converting current to a voltage. Red Black White Green Wire colors on transmitter cable Sts series water quality and temperature transmitter Channel 1 -- water quality transmitter Channel 2 -- temperature transmitter Temperature Sensor Water Quality Sensor

}cmp34s/ab 1-1/2 h PVC or equivalent Insertion (in-line) typical applicaton shown with anti-blow-out 316 SS compression fitting (P/N cmp34s/ab) Mounting Submersion Simply lower the transmitter and cable into the tank, lake, well, etc.. For applications that require more stability and/or protection of the cable and transmitter from mixers, chemical injection points, etc. -- reverse the cmp34s compression fitting and mount at the end of a standpipe or equivalent, as shown. (Conductivity transmitter shown in example at right)

Price list for STs series 4-20 ma ORP (redox) and Temperature transmitter Price ludes sensor, transmitters, and housing cable must be ordered separately. (Deduct 5% if prepaid via wire transfer) Jan 2013