Volume 115(11) November 1997 pp

Similar documents
Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT

Introduction. Chapter Aim of the Thesis

Optical coherence tomography

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging

The First True Color Confocal Scanner on the Market

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

Blood Vessel Tree Reconstruction in Retinal OCT Data

OCT mini-symposium. Presenters. Donald Miller, Indiana Univ. Joseph Izatt, Duke Univ. Thomas Milner, Univ. of Texas at Austin Jay Wei, Zeiss Meditec

Visual Optics. Visual Optics - Introduction

Going beyond the surface of your retina

Impressive Wide Field Image Quality with Small Pupil Size

Medical imaging has long played a critical role in diagnosing

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

The First True-Color Wide-Field Confocal Scanner

SUPPLEMENTARY INFORMATION

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm

High-resolution axial measurements of ocular tissues

The First True Color Confocal Scanner

Submission of Figures to the Japanese Journal of Ophthalmology

ABSTRACT 1. INTRODUCTION

Ultrahigh Resolution Optical Coherence Tomography

COMPARISON OF OPTICAL COHERENCE TOMOGRAPHY IMAGING OF CATARACTS WITH HISTOPATHOLOGY

Optical Coherence Tomography. RS-3000 Advance / Lite

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Light Microscopy. Upon completion of this lecture, the student should be able to:

ISO Ophthalmic optics and instruments Instruments to measure axial distances in the eye

Retinopathy From a Green Laser Pointer

Clinical evaluation and management of glaucoma is largely

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

This document is a preview generated by EVS

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography

Visual System I Eye and Retina

High-speed imaging of human retina in vivo with swept-source optical coherence tomography

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Binocular retinal eye-tracking system Product Requirements Document C. Light Technologies, Inc.

THEORY AND APPROACHES TO AUTOMATED IMAGE ANALYSIS IN DIGITAL PATHOLOGY

11/23/11. A few words about light nm The electromagnetic spectrum. BÓDIS Emőke 22 November Schematic structure of the eye

Analysis of posterior retinal layers in spectral optical coherence tomography images of the normal retina and retinal pathologies

Study of self-interference incoherent digital holography for the application of retinal imaging

EYE ANATOMY. Multimedia Health Education. Disclaimer

Digital Imaging and Communications in Medicine (DICOM)

Optical Coherence Tomography. RS-3000 Advance

Digital Image Processing

OPTICAL COHERENCE TOMOGRAPHY: OCT supports industrial nondestructive depth analysis

Reports. \ $mm>-j \ksiiimj

Optical Coherence Tomography Retina Scan Duo

Automated sub-retinal fluid detection comprising RPE-region using neighbouring pixel connectivity paradigm.

Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Optical Coherence Tomography. RS-3000 Advance 2

Title: Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography. RS-3000 Advance / Lite

Optimizing Performance of AO Ophthalmic Systems. Austin Roorda, PhD

Digital Imaging and Communications in Medicine (DICOM)

Eye. Eye Major structural layer of the wall of the eye is a thick layer of dense C.T.; that layer has two parts:

Sensory receptors External internal stimulus change detectable energy transduce action potential different strengths different frequencies

MEDICAL & LIFE SCIENCES

10/8/ dpt. n 21 = n n' r D = The electromagnetic spectrum. A few words about light. BÓDIS Emőke 02 October Optical Imaging in the Eye

Medical Photonics Lecture 1.2 Optical Engineering

Name: Date: Block: Light Unit Study Guide Matching Match the correct definition to each term. 1. Waves

Photoacoustic ophthalmoscopy for in vivo retinal imaging

Visualization of human retinal micro-capillaries with phase contrast high-speed optical coherence tomography

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Image Modeling of the Human Eye

Ultrahigh Speed Spectral / Fourier Domain Ophthalmic OCT Imaging

Dynamic Phase-Shifting Microscopy Tracks Living Cells

DIGITAL PHOTOGRAPHY Camera and image capture

The Eye. Nakhleh Abu-Yaghi, M.B.B.S Ophthalmology Division

The Confocal Tonal Shift

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

General Discussion. Chapter Development of the Instrument

Instruments Commonly Used For Examination of the Eye

Photoreceptor Disruption Related to Persistent Submacular Fluid after Successful Scleral Buckle Surgery

The Puzzle of Light and AMD

Moving from biomedical to industrial applications: OCT Enables Hi-Res ND Depth Analysis

TEPZZ A_T EP A1 (19) (11) EP A1. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

Introduction Approach Work Performed and Results

In vivo three-dimensional microelectromechanical endoscopic swept source optical coherence tomography

Image Database and Preprocessing

Alireza Akhlagh Moayed

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14

The Photoreceptor Mosaic

Non-contact Photoacoustic Tomography using holographic full field detection

Optical Coherence Tomography Imaging in Developmental Biology

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

MEMS tunable VCSEL light source for ultrahigh speed 60kHz - 1MHz axial scan rate and long range centimeter class OCT imaging

NIH Public Access Author Manuscript Opt Lett. Author manuscript; available in PMC 2010 August 9.

Practical work no. 3: Confocal Live Cell Microscopy

Better diagnosis and treatment all-in-one.

Single-photon excitation of morphology dependent resonance

Quantitative Measurements of. Autofluorescence with the Scanning Laser Ophthalmoscope. Appendix. Optical and Theoretical Considerations

Transcription:

http:/ /gateway l.ovid.com:80/ovidweb.cgi OPHTHALMOLOGY Copyright 1997 by the American Medical Association. All Rights Reserved. Applicable FARS/DFARS Restrictions Apply to Government Use. American Medical Association, 515 N. State St, Chicago, IL 60610. Volume 115(11) November 1997 pp 1425-1428 A Comparison of Retinal Morphology Viewed by Optical Coherence Tomography and by Light Microscopy [Laboratory Sciences ] Toth, Cynthia A. MD; Narayan, Drew G.; Boppart, Stephen A. MSEE; Hee, Michael R. MSEE; Fujimoto, Jim G. PhD; Bimgruber, Reginald PhD; Cain, Clarence P. PhD; DiCarlo, Cheryl D. DVM; Roach, W. Patrick PhD From Duke University Eye Center, Durham, NC (Dr Toth and Mr Narayan); Massachusetts Institute of Technology, Cambridge (Messrs Boppart and Hee and Dr Fujimoto); Medizinisches Laserzentrum, Lubeck, Gennany (Dr Birngruber); TASC Inc, San Antonio, Tex (Dr Cain); Unifonned Services University of the Health Sciences, Bethesda, Md (Dr DiCarlo); and Air Force Office of Scientific Research, BoIling AFB, Washington, DC (Dr Roach). Outline.Abstract.MA TERIALS AND METHODS.RESUL.COMMENT TS.REFERENCES Graphics.Figure 1.Figure 2.Figure 3 Abstract.!1 Objective: To compare the cross-sectional images of primate retinal morphology obtained by optical coherence tomography (OCT) with light microscopy to determine the retinal components represented in OCT images. ~: Laser pulses were delivered to the retina to create small marker lesions in a Macaca mulatta. These lesions were used to align in vivo OCT scans and ex vivum histologic cross sections for image comparison. ~: The OCT images demonstrated reproducible patterns of retinal morphology that corresponded to the location of retinal layers seen on light microscopic overlays. Layers of relative high reflectivity corresponded to horizontally aligned retinal components such as the nerve fiber layer and plexiform layers, as well as to the retinal pigment epithelium and choroid. In contrast, the nuclear layers and the photoreceptor inner and outer segments demonstrated relative low reflectivity by OCT. Conclusions: Retinal morphology and macular OCT imaging correlate well, with alignment of areas ofhigh and low reflectivity to specific retinal and choroidal elements. Resolution of retinal structures by OCT depends on the contrast in relative reflectivity of adjacent structures. Use of this tool will enable expanded study of retinal morphology, both normal and pathologic, as it evolves in vivo. Arch Ophtha1mo1. 1997;115: 1425-1428 of9 9/24/01 9:53 AM

LIGHT MICROSCOPY has been a gold standard for analysis of retinal morphology at the micron to millimeter scale. There has historically been no in vivo tool capable of resolving the small structures that comprise the retinal layers. Traditional ophthalmic ultrasound is limited to resolution of75 micrometers. Scanning laser ophthalmoscopy, although using visible and infrared radiation for in vivo imaging, does not display a vertical cross section of structures within the retina. U:;?J Numerous new optical ranging systems have been proposed to delineate the structure of normal retina and of disease processes within its tissues. Optical coherence tomography (OCT) is one of these techniques, and has been applied in numerous studies ofhealthy and diseased human tissues, Ll:2l although without clinicopathologic correlation. In this study, we provide a direct comparison of OCT and histologic images of the Macaca mulatta macula. MATERIALS AND METHODS.tJ A mature M mulatta was maintained under standard laboratory conditions in accordance with the Association ofvision Research in Ophthalmology Statement for the Use of Animals in Ophthalmic and Vision Research and federal guidelines. Preoperative care, anesthesia, intraoperative and postoperative care, euthanasia, and tissue processing were performed as previously published. llq1 Animals were anesthetized during all procedures including laser lesion placement and OCT scanning and image acquisition. In this study, we used 5-picosecond, 580-nm, 0.02- to 0.1 O-mJ laser pulses to create retinal lesions, rather than the argon laser as previously reported. [21 The refractive error for the 2 eyes was +0.50-0.25 x180 OD and +0.25 OS. The OCT imaging was not scaled for the minimal refractive error. To correlate histologic sections with OCT images, the retinal laser lesions were observed through the fundus camera, allowing alignment of the OCT imaging beam over the center of each lesion. The margins of the laser lesions were used to align the overlay of OCT and light micrograph cross sections. The OCT scan, a 2-dimensional cross-sectional high-resolution retinal image, was acquired in 4 seconds by assembling 200 adjacent longitudinal (depth) profiles of optical backscattered intensity as the OCT imaging beam was scanned across 500 micrometers of retina (200x250 pixels). For OCT, the color spectrum depicting the logarithmic scale of reflectivity (left parts of (Figure 1 ), (~.f.), and (Fi&!:!re 3)) is arbitrary with the red end of the spectrum selected for pixels corresponding to sites of relative high reflectivity (RHR) (backscatter), and blue for relative low reflectivity (RLR). 2of9 9/24/01 9:53 AM

avid: Toth: Arch Ophthalmol, Volume 115(11).November 1997.1425-1428 3 of9 9/24/01 9:53 AM

Ovid: Toth: Arch Ophthalmol, Volume I 15(11).November 1997.1425-1428 Figure.... with methylene blue (right). An outline of the retinal layers from the corresponding light micrograph is superimposed over the OCT image. Note the coalescence of layers entering the fovea. The open arrows indicate the broad layer of relative low reflectivity that corresponds to the nuclear layer and inner and outer segments of the photoreceptors. This layer widens in the fovea. ~-!4of9 9/24/01 9:53 AM

Ovid; Toth; Arch Ophthalmol, Volume 115(11).November 1997.1425-1428 Figure 3. Optical coherence tomography (OCT) ofa section of macula adjacent to another laser lesion (left) and its corresponding histologic section stained with methylene blue (right). An outline of the retinal layers from the corresponding light micrograph is superimposed over the OCT image. This site is further from the fovea than that in (~). As in (~) and (~), the open arrows point to the confluence of relative low reflectivity corresponding to the nuclear layer and inner and outer segments of the photoreceptors. For each site, OCT scans were obtained immediately before and after laser placement. The retina adjacent to the laser lesion, but greater than 100 micrometers from the margins of the laser lesion, was used for comparison (Figure 1 ). The macula was oriented for sectioning in the plane of OCT scans. Digital images of sections and a micrometer were obtained using a Zeiss light microscope with a charge coupled diode (CCD) camera feeding to a personal computer (Macintosh, Apple, Cupertino, Calif). Images were captured using Scion Image (National Institutes of Health program, Bethesda, Md) and stored and manipulated using Adobe Photoshop (Adobe Systems Inc, Mountain View, Calif). The distance between the nerve fiber layer and the retinal pigment epithelium (RPE) was measured with the micrometer image at 4 or more sites on the light micrographs. The OCT images were measured at corresponding locations using the 250-micrometers scale bar. Correction for the difference between 5 of9 9/24/019:53 AM

image size was achieved by compressing the light micrographs equally along both axes, after which the margins of the anatomic layers were traced over the light micrographs and superimposed on the OCT images (~). RESULTS.tJ The OCT images demonstrated clear reproducible patterns of retinal structure. From scan to scan, the overall level of retinal reflectivity varied, possibly because of small variations in corneal hydration and alignment of the scanning beam with respect to the retina. The relative reflectivity of retinal layers did not vary, ie, the retinal components always maintained the same relationship of RHR or RLR as described below. The retinal thickness measured from the histologic section was greater than the OCT image in both eyes. The histologic images averaged 4% and 12% larger than the corresponding OCT image in the right and left eye, respectively. A layer ofrhr corresponded to the location of the nerve fiber layer (solid arrow in (Figure 3), left). Although this signal varied in intensity, the nerve fiber layer was the most highly reflective of all neurosensory retinal layers, matching or exceeding the underlying plexiform layers. The depth of the region of RHR corresponded to the thickness of the nerve fiber layer by light microscopy. Thus, the RHR layer increased in thickness with increasing proximity to the optic nerve. Additional layers ofrhr corresponded to the location of the plexiform layers of the retina. Throughout the macula, highly reflective regions correspond to areas of horizontal retinal elements, whether nerve fiber layer at the retinal surface or deeper plexiform layers. These layers converged into a single RHRlayer over a single layer ofrlr in the fovea (Figure 2). Retinal areas ofrlr corresponded to the location of the nuclear layers and the photoreceptor inner and outer segments. The RLR of the outer nuclear layer, and the photoreceptor inner and outer segments together, consistently demonstrated the most prominent broad band of RLR ( open arrows in (~), (~) and (Fig!!re 3). These vertically aligned structures were the only nonnuclear retinal elements to demonstrate RLR. In the fovea, we also saw convergence of the RLR layers with only a single outer band of RLR present in the center of the fovea. The choroid and RPE together matched to a wide band ofrhr that eventually decreased at greater choroidal depth. In OCT, we could not identify a separate RPE image from the underlying choroid. The RHR of these layers was pronounced and often greater than the reflectivity of the surface nerve fiber layer, despite the fact that this portion of the OCT image traveled through the neurosensory retina twice before detection. COMMENT.!.J We demonstrated the effectiveness of in vivo OCT in delineating the location and relative reflectivity of elements of the primate macula in cross section in direct correlation to light micrographs of these retinal sites. We also demonstrated some of the limits in the resolution of this OCT system when compared with light microscopic study of fixed, stained tissue. We further showed that imaging retinal structures depended not only on the resolving power of the instrument, but also on the contrast in relative reflectivity of adjacent retinal structures. Optical coherence tomography and light microscopy are fundamentally different techniques that generate images of microscopic tissue elements. Optical coherence tomography utilizes propagation 6of9 9/24/01 9:53 AM

of light through, and the time delay of light reflected back from, unstained tissue to identify location and relative reflectivity of microstructures. Sites of RHR and RLR correlate with the location of varying backscatter of photons that return to the OCT device for comparison within the coherence length of the source. Images obtained with OCT are thus highly dependent on the optical properties of the structure and cannot be interpreted in the same manner as staining of cellular elements in fixed tissue sections. Thus, the direct histologic correlation in this study helps define the location and types of tissue elements that create variations in optical backscatter and, hence, variations within the OCT image. G: l Light micrographs of fixed tissue, although the gold standard in this comparison, have their own drawbacks. To obtain macular specimens the tissue must be surgically removed, rapidly fixed, and then dehydrated with minimal distortion. The tissue must be embedded with the correct orientation, blocks must be sectioned, and the tissue of interest stained. Visualizing retinal structure depends on the tissue staining or labeling characteristics. Each step adds potential artifact to the final imaging of retinal morphology. Retinal excision is also not an option in most macular evaluation. In contrast, this OCT system has poorer resolution than light microscopy, and cannot separate the image of adjacent tissues if they have matching relative reflectivity ( eg, the RPE and choroid, or photoreceptor outer segments and photoreceptor nuclei). Optical coherence tomography does, however, present an in vivo undisturbed image of retinal structure in situ. The drawbacks ofoct imaging include image processing algorithms that may misrepresent retina surface contours, refractive index effects, and optical attenuation with depth in some tissues or materials. These limitations explain the difficulty in acquiring peripheral retinal images, the dependency of OCT imaging on clear ocular media and a smooth cornea, and the limited axial depth of the OCT image within the choroid (Figure I), (Figure 2), and (Figure 3). IfOCT measurements are performed in a consistent manner, these effects are a constant part of the baseline. Thus, the diagnostic power of OCT requires that the user understands the method of image acquisition, bases clinical measurements on known correlation with histopathologic characteristics, and relies on detecting deviations from a known baseline. We have not deternlined why a particular retinal structure demonstrates RHR or RLR. We hypothesize that it is the horizontal orientation, size, and structure of the nerve fibers and plexifornl layer components that deternlines the RHR. The RHR may also be accentuated in the inner retina where the first major fundus reflection occurs. In contrast, photoreceptor inner and outer segments demonstrate RLR possibly because of their regularly aligned microstructural elements and vertical macrostructure. Intracellular and extracellular fluid, membrane orientation, or a cellular chromophore could also affect local approximately 840-nm photon absorption or reflectivity, and thus the OCT image. A change in local retinal physiology might be identified only in OCT scans or only in light micrographs or with both techniques. This would depend on whether in vivo reflectivity or ex vivum staining or labeling of tissue elements was affected by the injury or disease process. Further OCT studies and the use of different scanning wavelengths may clarify this. We recognize that OCT and light microscopy use very different approaches to analyze cellular elements and therefore the images do not describe the same tissue characteristics. However, in this study we have shown a correlation between primate macular structure and of macular OCT images, with close alignment between zones of RHR or RLR and specific retinal or choroidal elements. In future applications, sequential OCT imaging will improve our understanding of the temporal evolution of the morphology of the normal, diseased, or injured retina. Accepted for publication June 9, 1997. 7 of9 9/24/01 9:53 AM

This research was sponsored by us Air Force (USAF) Arrnstrong Laboratory, and the Air Force Office of Scientific Research, Air Force Systems Command, under grants F49620-95-1-0226 and 2312AA -92ALO 14 and contract F3 3615-92-C-OO 17. The US Government is authorized to reproduce and distribute reprints for govemmenta1 purposes not withstanding any copyright notation thereon. The views and conclusions contained in this article are those of the authors and should not be interpreted as necessarily representing the official policies or endorsements, either express or implied, of the Air Force Office of Scientific Research or the Government. We would like to thank Ewa Womiallo for her support of the histopathology effort in preparation of the manuscript. Reprints: Cynthia A. Toth, MD, Duke University Eye Center, Box 3802, Erwin Road, Durham, NC 27710 (e-mail: tothoo04@mc.duke.edu). REFERENCES.tJ 1. Menezes A V, Giunta M, Chisholm L, Harvey PT, Tuli R, Devenyi AG. Reproducibility of topographic measurements of the macula with a scanning laser ophthalmoscope. Ophthalmology. 1995;102:230-235. rmedline Link] rblosis Previews Linkl rcontext Linkl 2. Manivannan A, Kirkpatrick JNP, Sharp PF, Forrester N. Clinical investigation of an infrared digital scanning laser ophthalmoscope. Br J Ophthalmol. 1994;78:84-90. [Medline Linkl [BIOSIS Previews Linkl [Context Link] 3. Fujimoto JG, Brezinski ME, Tearney GJ, et al. Optical biopsy and imaging using optical coherence tomography. Nature Med. 1995; I :970-972. [Medline Linkl [BIOSISPreviews Link] [Context Link] 4. Hee MR, Puliafito CA, Wong C, et al. Optical coherence tomography of macular holes. Ophthalmology. 1995;102:748-756. [MedlineLinkl[BIOSIS Previews Linkl rcontext Linkl 5. Hee MR, Izatt JA, Swanson EA, et al. Optical coherence tomography of the human retina. Arch Ophthalmol. 1995; 113:325-332. rfulltext Link) [Medline Linkl [BIOSIS Previews Linkl rcontextlink) 6. Hee MR, Puliafito CA, Wong C, et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol. 1995;113:1019-1029. rfulitext Link] rmedline Linkl [BIOSlSPreviews Linkl [Context Linkl 7. Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991;254: 1178-1181. rmedline Linkl [Context Link] 8. Puliafito CA, Hee MR, Lin CP, et al. Imaging of macular diseases with optical coherence tomography. Ophthalmology. 1995;102:217-229. [Medline Linkl [BIOSIS Previews Linkl [Context Linkl 9. Puliafito CA, Hee MR, Schulman JS, Fujimoto JG. Optical Coherence Tomography ofocular Diseases. Thorofare, NJ: Slack Inc; 1996. [Context Link] 10. Toth CA, Bimgruber R, Boppart SA, et al. Retinal argon laser lesions evaluated in vivo by optical coherence tomography. Am J Ophthalmol. 1997;123:188-198. [Medline Link) rbioslspreviews Linkl rcontext Linkl Macaca mulatta; Macula Lutea; Microscopy; Retina; Tomography Accession Number: 00000820-199711000-00011 Copyright (c) 2000-2001 Ovid Technologies. Inc. 8 of9 9/24/01 9:53 AM