Instruction Manual IDM 66RT Digital Multimeter

Similar documents
Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

Safety Information. WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

IDM 98-III & IDM 99-III Digital Multimeters

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Instruction Manual IDM 503 & IDM 505 Digital Multimeters IDM 505

IDM 503 & 505 Digital Multimeters

IDM 61/62T Instruction Digital Multimeter Manual

ICM 136R Operating Instruction Electrical Clamp-Multimeter

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

Instruction Manual. IM Axis RF Field Strength Meter

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Electrical Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

# Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

312, 316, 318. Clamp Meter. Users Manual

KMD-S04 Multímetro de bolsillo

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

User Manual. Solar Power Clamp. 99 Washington Street Melrose, MA Phone Toll Free

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

BENNING. CM7 Electrical Tester. Service Information

600A Clamp Meters w/tightsight Display

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User Manual. All rights reserved. Specifications are subject to change without notice.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Data sheet IDM 98III Digital Multimeter

Data sheet IDM 99III Digital Multimeter

12B/18 MultiMeter Instruction Sheet

DMM8900 SERIES USERS MANUAL

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

AMM-1022 Digital Multimeter USER`S MANUAL

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Dawson DDM190. Digital Multimeter User s Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

15B & 17B. Users Manual. Multimeters

374/375/376 Clamp Meter

Model UT10A: OPERATING MANUAL Table of Contents (1)

MS8223A. CAT.IIi 600 V

netzerotools.com 374/375/376 Users Manual Clamp Meter

True RMS Digital Multimeter Model:

CONTENTS MS2033A. 1.Introduction Safety Information...01

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

374/375/376 Clamp Meter

USER'S MANUAL DMR-6700

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Digital Clamp Meter Model: &

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

AC/DC CLAMP METER USER S MANUAL

Analog Technologies. Multimeter 15B and17b

MS2030 CAT III 600 V A V AUTO RS232

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

UT207A/208A/209A Operating Manual. Table of Contents

DVM1190 DIGITAL MULTIMETER

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Electrical Multimeter

DDM350 Pen-Type Digital Multimeter User s Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

79/26 Series III Multimeter

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

NI 71/72. Multimeter. Manual

200Amp AC Clamp Meter + NCV Model MA250

User Guide. Digital AC/DC Clamp Meter Model 38394

Model : OPERATING MANUAL Table of Contents (1)

User s Guide. Digital AC/DC Clamp Meter Model 38394

Pen Multimeter. Model

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Autoranging Multimeter Extech EX503

AUTO RANGING DIGITAL MULTIMETER

DM-45 Digital Multimeter

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User Manual Digital Multimeter. model no.: MSR-U1000

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

ATK Clamp Meter

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

OPERATOR S INSTRUCTION MANUAL

1.General instructions Specifications Description...7

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Instruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES

400Amp True RMS AC/DC Clamp Meter Model EX613

Transcription:

Instruction Manual IDM 66RT Digital Multimeter EN

Warning...................................... Safety sheet.............................................. Read First Safety Information Understand and follow operating instructions carefully. WARNING When using test leads or probes, keep your fingers behind the finger guards. Remove test lead from Meter before opening the battery door or Meter case. Use the Meter only as specified in this manual or the protection by the Meter might be impaired. Always use proper terminals, switch position, and range for measurements. Never attempt a voltage measurement with the test lead inserted into the A input terminal. Verify the Meter s operation by measuring a known voltage. If in doubt, have the Meter serviced. Do not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground. Do not attempt a current measurement when the open voltage is above the fuse protection rating. Suspected open circuit voltage can be checked with voltage function. Only replace the blown fuse with the proper rating as specified in this manual. Use caution with voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose a shock hazard. To avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator < appears. Disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. Do not use Meter around explosive gas or vapor. To reduce the risk of fire or electric shock do not expose this product to rain or moisture. 1

Caution Disconnect the test leads from the test points before changing the position of the function rotary switch. Never connect a source of voltage with the function rotary switch in Ω / / ;/ position. Do not expose Meter to extremes in temperature or high humidity. Never set the meter in A function to measure the voltage of a power supply circuit in equipment that could result in damage the meter and the equipment under test. Symbols as marked on the meter and Instruction card Risk of electric shock See instruction card DC measurement Equipment protected by double or reinforced insulation Battery Fuse Earth 2 AC measurement Conforms to EU directives Do not discard this product or throw away Maintenance Do not attempt to repair this Meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. Cleaning Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents. 2

Front Panel Illustration 1. Voltsense Light 2. LCD display : 6000 counts 3. Push-buttons. 4. Rotary switch for turn the Power On / Off and select the function. 5. Input Terminal for,hz,v,ω, C functions. 6. Common (Ground reference) Input Terminal. 7. Input Terminal A function. 3

Making Basic Measurements The figures on the following pages show how to make basic measurements. Caution When connecting the test leads to the DUT (Device Under Test) connect the common test leads before connecting the live test leads ; when removing the test leads, remove the live test leads before removing the common test leads. Measuring AC / DC Voltage / Frequency Dial the switch and press the Function button to select the measuring function. 4

Measuring AC/DC Current Disconnect Dial the switch and press the Function button to select the measuring function. Measuring Capacitance Dial the switch to select the measuring function. 5

Measuring Continuity / Diode / Resistance Red Black Red Black Red Black Dial the switch and press the Function button to select the measuring function. 6

Measuring Temperature C / F Sensor K Type Dial the switch and press the Function button to select the measuring function. ( C / F) Set the default temperature units 7

Using The Function Function Button Press Press Press Function Button >2 Sec to Auto Sense Mode Switch Position Function Auto Sense Auto Auto Auto Sense Auto Auto Auto Sense Auto Auto Press the Function button to change the function on the same switch position. 8

Range Button Press Press Press Press Range Button >2 Sec to Auto Mode Peak Hold Press Button > 2 sec Leave the peak hold mode In the Peak Hold function,the meter records the peak min. value and the peak max. value when the inputs goes below the recorded peak min. value or above the recorded peak max. value,the meter records the new value. Press Hold button to pause the recording. 9

Smart Hold The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts. (However,it can not detect across the AC and DC Voltage /Current). VoltSense Dial the switch to select the measuring function. Caution The number of dashes displaying on the display indicates the electric field in density. If no indication, voltage could still be present. 10

Auto Power Off Wake-up the meter by dialing the switch or pressing any button. Disable Auto Power Off Dial the switch to off position,then keep the Function button down and turn the meter on. 11

Testing LCD Monitor Dial the switch to off position,then keep the HOLD button down and turn the meter on. Fuse Replacement Fuse type : 11A/1000V 20KA (10x38mm) 12

Low battery and Battery Replacement Replace the battery as soon as the low battery indicator appears, to avoid false reading. Refer to the following figure to replace the batteries Caution Remove test leads from Meter before opening the battery cover or Meter case. 13

Specifications General Specifications Maximum voltage applied to any terminal : 1000 Vac rms or 1000 Vdc. Display : 6000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : "OL" or "-OL" Batteries Life : 150hours ALKALINE Battery Low Batteries Indication : Voltage drops below operating voltage, will flash. Power Requirement : AAA Size Batteryx2 Operating Temperature : -10 ~10 C 10 C ~ 30 C ( 80% RH), 30 C ~ 40 C ( 75% RH), 40 C ~ 50 C ( 45%RH) Storage Temperature : -20 C to 60 C, 0 to 80% R.H. (batteries not fitted) Measure : Samples 3 times per second. Altitude : 6561.7 ft (2000m) Safety : Complies with EN61010-1 / IEC61010-1, CAT III 600V, CAT II 1000V, EN61010-2-030, EN61326-1 CAT Application field Ⅰ Ⅱ Ⅲ Ⅳ The circuits not connected to mains. The circuits directly connected to Low-voltage installation. The building installation. The source of the Low-voltage installation. Weight : 320g (including battery) Dimensions (W x H x D) : 74mm x156mm x 44mm Pollution degree : 2 Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.) Drop Protection : 4 feet drop to hardwood on concrete floor. Indoor Use. 14

Electrical Specifications Accuracy is given as ±(% of reading + counts of least significant digit) at 23 C ± 5 C, with relative humidity Less than 80% R.H. Accuracy is specified for a period of one year after calibration. 1. Temperature coefficient 0.15 x (Specified accuracy) / C, < 18 C, > 28 C 2. AC Function ACV and ACA specifications are ac coupled, true R.M.S. The crest factor may be up to 3.0 as 4000 counts. For non-sinusoidal waveforms, Additional Accuracy by Crest Factor (C.F.) : Add 3.0% for C.F. 1.0 ~ 2.0. Add 5.0% for C.F. 2.0 ~ 2.5. Add 7.0% for C.F. 2.5 ~ 3.0. There is a little rolling less than 10 digits in Auto AC & DC Test Mode when measuring AC signal. 3. DC Voltage Range Resolution Accuracy 60.00mV 0.01mV ±(0.5% + 10 dgt) 600.0mV 0.1mV 6.000V 0.001V 60.00V 0.01V 600.0V 0.1V 1000V 1V ±(0.5% + 2 dgt) Input Impedance : 3.5MΩ (600.0mV Range) 12MΩ (Others) Overload Protection : 1000V for V, 600V for mv. 15

4. AC Voltage Range 60.00mV 600.0mV Resolution Accuracy (Sine Wave) 0.01mV 0.1mV 6.000V 0.001V 60.00V 0.01V 600.0V 0.1V 1000V 1V ±(1.2% + 5 dgt) ±(1% + 5 dgt) LCD displays 0 counts when the reading < 20 counts (60.00mV range only) LCD displays 0 counts when the reading < 10 counts (other ranges) Input Impedance : 3.5MΩ (600.0mV Range) 12MΩ // less than 100pF (Others) Frequency Response : 45 ~ 500Hz (Sine Wave) Overload Protection : 1000V for V, 600V for mv. 5. DC Current Range Resolution Accuracy 6.000A 0.001A 10.00A 0.01A ±(1% + 2 dgt) Maximum measurement time : 5 minutes at 10A with at least 20 minutes rest time. Overload Protection : AC/DC 11A 6. AC Current Range 6.000A 0.001A 10.00A 0.01A Resolution Accuracy (Sine Wave) ±(1.5% + 5 dgt) LCD displays 0 counts when the reading < 20 counts (6.000A range) 16

LCD displays 0 counts when the reading < 10 counts (10.00A range) Frequency Response: 45 ~ 500Hz (Sine Wave) Maximum measurement time: 5 minutes at 10A with at least 20 minutes rest time. Overload Protection: AC/DC 11A 7. Resistance Range Resolution Accuracy 600.0Ω 0.1Ω ±(0.8% + 5 dgt) 6.000kΩ 0.001kΩ ±(0.8% + 2 dgt) 60.00kΩ 0.01kΩ ±(0.8% + 2 dgt) 600.0kΩ 0.1kΩ ±(0.8% + 2 dgt) 6.000MΩ 0.001MΩ ±(0.8% + 2 dgt) 40.00MΩ* 0.01MΩ ±(2% + 3 dgt) * There is a little rolling less then ±50 digits when measuring > 10.00 MΩ. Open Circuit Voltage : Approx. 1.0V @ 600.0Ω ~ 600.0kΩ range. Approx. 1.7V @ other ranges. Overload Protection: AC/DC 600V 8. Continuity Range Resolution Accuracy 600.0Ω 0.1Ω ±(0.8% + 5 dgt) Open Circuit Voltage : Approx. 1.0V Max. Short Current : Approx. 250uA Continuity : Built-in buzzer sounds when measured resistance is less than 30Ω and sounds off when measured resistance is more than 200Ω, Between 30Ω to 200Ω the buzzer maybe sound or off either. 17

Continuity Indicator : 2kHz Tone Buzzer Overload Protection : AC/DC 600V 9. Diode Range Resolution Accuracy 1.500V 0.001V ±(1% + 3 dgt) Open Circuit Voltage : Approx. 1.8V Max. Short Current : Approx. 400μA Overload Protection : AC/DC 600V 10. Capacitance Range Resolution Accuracy 10.00nF 0.01nF ±(1.9% + 8 dgt) 100.0nF 0.1nF ±(1.9% + 8 dgt) 1000nF 1nF ±(1.9% + 8 dgt) 10.00µF 0.01µF ±(1.9% + 8 dgt) 100.0µF 0.1µF ±(1.9% + 8 dgt) 1000µF 1µF ±(1.9% + 8 dgt) 10.00mF 0.01mF ±(1.9% + 8 dgt) Response Time : Approx. 7 sec. when measuring 10.00mF Approx. 1 sec. when measuring 100uF Overload Protection : AC/DC 600V 18

11. Temperature Range Resolution Accuracy -40.0 C ~ 400.0 C 0.1 C ±(1% + 10 dgt) -40.0 F ~ 752.0 F 0.1 F ±(1% + 18 dgt) Do not include accuracy of the thermocouple probe. Accuracy specification assumes surrounding temperature stable to ±1 C. For surrounding temperature changes of ±3 C, rated accuracy applies after 2 hours. Overload Protection : AC/DC 600V. 12. Frequency Range Resolution Accuracy 6000Hz 1Hz ±(0.1% + 2 dgt) 60.00kHz 0.01kHz ±(0.1% + 2 dgt) 100.0kHz 0.1kHz ±(0.1% + 2 dgt) Min. Sensitivity (Sine Wave, RMS Value) : 8V Min. Frequency : 1Hz Overload Protection : AC/DC 1000V 13. Peak Hold Specified accuracy ± 200 digits. Response Time of DC signal : 50ms Response Time of AC signal : 250μs 14. VoltSense Voltage Range : 80V ~ 1000V (At the top of the meter) 19

Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. For full terms and conditions, refer to the RS website. 20

Africa RS Components SA P.O. Box 12182, Vorna Valley, 1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa www.rs-components.com Asia RS Components Pte Ltd. 31 Tech Park Crescent Singapore 638040 www.rs-components.com China RS Components Ltd. Suite 23 A-C, East Sea Business Centre Phase 2, No. 618 Yan'an Eastern Road Shanghai, 200001 China www.rs-components.com Europe RS Components Ltd. PO Box 99, Corby, Northants. NN17 9RS United Kingdom www.rs-components.com Japan RS Components Ltd. West Tower (12th Floor), Yokohama Business Park, 134 Godocho, Hodogaya, Yokohama, Kanagawa 240-0005 Japan www.rs-components.com U.S.A Allied Electronics 7151 Jack Newell Blvd. S. Fort Worth, Texas 76118 U.S.A. www.alliedelec.com South America RS Componentes Limitada Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile www.rs-components.com