GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Similar documents
New Single Straight Tube Type OVAL Coriolis Mass Flowmeter. MK Transmitter : ST9101, ST9801. See general performance table (page 2).

High Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing

Straight-Tube Coriolis Flowmeter. SUS316L Housing. JIS 10, 20K RF, ASME/JPI 150 RF, IDF ferrule Applicable fluid

Cost-Effective Coriolis Flow Meters. PRO Series Meters

Straight-Tube Coriolis Flowmeter

High Performance Coriolis Flowmeters

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 02

FLOWPET-NX (Oil Service Mechanical Register)

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 01

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

FH CMF Coriolis Mass Flow Meters

Model RFT9709 Transmitter Instruction Manual

Digital flow transmitter for continuous flow measurement

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

PAD - Heavy Duty Differential Pressure Trasmitter

Design and applications

Mass and Volume Flow Transmitter

LZYN Triangle Series Mass Flow Meter

Coriolis Massflowmeter

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Coriolis Massflowmeter

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

KFS. Flap-type flow meter. Design and range of application

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

ADDMAS CORIOLIS MASS FLOW METER

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Mass Flow and Density Transmitter

Series 10-ZSE30A(F)/10-ISE30A

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

LZYN Mass Flowmeter Instruction Manual

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

TMU. Coriolis Mass Flow Meter. for liquids and gas

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

FLOMID FX Electromagnetic Flowmeter

SATRON VB Pressure Transmitter

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

General Specifications

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Kotron Sentinel Model 804 RF Level Transmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

INSTRUCTION MANUAL (ATEX / IECEx)

Electro-Magnetic Flowmeters COPA-XE

ThermoPLUS Smart Temperature Transmitter

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

M-2111 Series Ultrasonic Flow Meter

Installation guide 971 SmartRadar LTi

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Coriolis Mass Flow Meter Model TM

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

+GF+ SIGNET Temperature Transmitter Instructions

INSTALLATION AND OPERATION MANUAL

Target disk flowmeter for liquids and gases

Electromagnetic Flow Transmitter

Ambient Conditions. Operating Conditions. Pressure

Signet 9900 Transmitter

mass flowmeter for compressed air

Series 1000 and 2000 Transmitters with MVD TM Technology

Digital flowmeter for continuous flow measurement

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Digital flowmeter for continuous flow measurement

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

Introducing GPI s Latest

B850 Boiler House Energy Monitor

Non-Submersible Industrial Pressure Transducer

B850 Boiler House Energy Monitor

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

RCM DIRECT READING FLOWMETER

Coriolis Massflowmeter

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Digital flow ELEMENT transmitter for continuous flow measurement

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

Rotamass TI Coriolis Mass flow meter

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

INLINE flowmeter for continuous flow measurement

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Metal tube variable area flowmeters for gases, liquids and steam

Digital flow ELEMENT transmitter for continuous flow measurement

A new approach to static electricity countermeasures

ED701 General Industry Pressure Transmitter

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Ultrasonic level transmitter, non-contact

Kotron Sentinel Model 804 RF Level Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

DRS390 High stability, flange mounting

Signet 9900 Transmitter

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Magnetostrictive Level Transmitter

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Transcription:

High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis meter lineup by adding accurate, ultralow flowmetering products. The latest addition meets the expanding market needs for explosionproof products characterized by "improved performance, user friendliness, and increased operating safety." FEATURES 1. World s smallest Coriolis flowmeters to measure extremely low flows from 0.2 g/min (0.4g/min). 2. Measures density at the same time (option). 3. Operates under pressures up to 15MPa. (20 for liquids). 4. Vibration proof base no longer required; installs directly in the piping. GENERAL SPECIFICATIONS Sensor unit Model CN00AK-SS-200R CN001K-SS-200R Nominal size 1/4 Wetted parts SUS316L Materials Casing O-rings SUS304 Fluorine rubber (Viton) Process connection Applicable fluid Density range R1/4 Liquid and Gases 0 2.0 g/ml Temperature ratings 200 to 200 Temperature Ex. temp. class T3 20 to 120 ratings Ex. temp. class T4 20 to 55 Max. operating pressure Lipuid 15MPa at 20 Gas 0.98MPa Flow directions Flameproof enclosure Forward and reverse (option) TIISExib II BT3, Exib II BT4 () Compliance with high pressure gas regulations is not applicable. Transmitter (CT9401) Power supply Power consumption Ambient temperature Transmission length Appliccble EU Directire Appliccble EN standard Explosionproof configuration Dustproof, waterproof construction Installation Display Mass Status input Pulse output Analog output Status output Description 85 to 264VAC50/60Hzor 20 to 30VDC 25VA max. or 10W max. 20 to 50Non condensing 200 meters max. (using the exclusive cable) EMC Directione89/336/EEC, 92/31/EEC, 93/68/EEC EMCEN550111998/A11999 Group 1 Class B EN6100-6-21999 Combined explosionproof ExdibIIBT4 IP66 Separately mounted LCD display (7-segment 8-digit) 5.8kg approx. Contact-closure input (Form a contact input), Close200 or less; Open100 or over Select one from function OFF (default), remote zero, total reset, or 0% signal lock. Open collector output (10V 30V, 50mADC max.), FS0.1 10000Hz or voltage pulse (option) 0: 1.5V max., 1: 15V min., output impedance 2.2k 4 20mADC Max. load 600 Select two from instantaneous flowrate (mass or volume), temperature, or density. Damping (std) : flow 1 sec; density 4sec; temp. 2.5sec. Open collector output Normal: ON, Error: OFF30V, 50mADC max. Select one from error (default), flow direction, or Hi/Low alarm. OVAL Corporation Head Office Tokyo): Tel. 81-3-3360-5121. Fax. 81-3-3365-8605 Beijing Office: Tel. 86-10-5867-4711. Fax. 86-10-5867-4713 Overseas Branch Offices: Seoul, Singapore and Taipei http://www.oval.co.jp

MassFlex Series GENERAL PERFORMANCE Description Model CN00A CN001 Max. service range, g/min 0 to 40 0 to 150 Max. allowable range, g/min 0 to 60 0 to 225 Min. range, g/min 0 to 2 0 to 7.5 Flowrate Lower limit rate, g/min 0.4 1.5 Factory calibration Liquid 0.2%zero stability errorof reading accuracy Gas 0.5%zero stability errorof reading Repeatability Liquid 0.05%1/2 zero stability errorof reading Gas 0.25%1/2 zero stability errorof reading Zero stability, g/min 0.006 0.0225 Density Measuring range 0.32g/mL liquid Factory calibration accuracy (option) 0.003g/mL Analog accuracy Accuracy0.1% of full scale In gas measurement, the maximum allowable flowrate varies with the kind of gas and operating pressure. Consult the factory for confirmation. Zero stability (g/min) Zero stability error= x 100% Flow rate at that time (g/min) TEMPERATURE-PRESSURE RATINGS Temperature, Allowable press. Liquid MPa Gas METER ERROR Temperature, Allowable pressure, MPa DISPLAY 1: Instantaneous mass flow rate 2: Instantaneous volume flow rate 3: Density 4: Temperature 5: Totalized flow (mass or volume) 6: Analog output 1 (% indication) 7: Analog output 2 (% indication) Display unit 8: SEt PASS Display modes are selectable with a sensor of infrared rays behind the display window.

MK MassFlex Series PRESSURE LOSS CN00A CN001 Pressure loss factor, C Pressure loss factor, C How to determine pressure loss 1. Find the pressure loss factor C from flow rate (g/min) and viscosity (mpa s). Dividing the obtained value C by specific gravity d (1 for water) gives the pressure loss. That is, P= C (MPa) d For high viscosity liquids not shown in the graph, consult the factory. TELEMETERING HOOK-UP 1 ULTRA Analog output (flow rate, temp. or density) Flowrate pulse output Transmitter CT9401 (Separate type) Personal Computer 2 1 The separate type, the sensor unit and transmitter are connected with exclusive cable. 2 EL2300: Smart Communication Unit. See General Specification sheet No.GEL102E.

MK MassFlex Series DIMENSIONS [Unit in mm] Weight:9kg (Approx.) 290 240 70 180 20 70 110 133 107 120 74 ULTRA 123 160 124 131 U-bolt for 2 pipe (2 Places) Conduit connection (G1/2) Non Intrinsically safe side 50 55 Conduit connection (G1/2) Intrinsically safe side 56

MK MassFlex Series WIRING CONNECTIONS-1 (CT9401) ULTRA Separation cover to be applied in a hazardous area Shield wires (Brown/Red) Clip here except for shield wires covering BWN and RED wires. Special cable (Max. 200m) Shield (Protected by black tube) Brown Red Brown Red Separation cover to be applied in a hazardous area (Sensor terminal box) Green White Cut Blue Gray Cut Purple Yellow Orange Cut Green White Blue Gray Purple Yellow Orange Shield wires (BWN/RED, GRN/WHY, BLU/GRY, PUR/YEL/ORG) Shield (Protected by black tube) (Transmitter terminal box) (CT9401) NOTE 1. Do not fail to use special cable. 2. Shield wire preparation (1) Transmitter end: Bundle the shield wires corresponding with brown/red, green/white, blue/grey, purple/yellow/orange and slip the black sleeve over them as shown in the figure, exercising care to avoid potential contact with the housing and other conductive parts. (2) Sensor end: Slip the black sleeve over the shield wires corresponding with brown/red pair cable as shown in the figure, exercising care to avoid potential contact with the housing and other conductive parts. Clip all other shield wires. How to install the cover. After wiring with the relay terminals, install the cover as shown below. Fix Special cable Separation cover

+ LINE/+ GND NEUT/ EARTH 1 2 3 4 5 6 7 8 9 10 11 12 MassFlex Series WIRING-2 CT9401 Transmitter PULSE PULSE S OUT S OUT S IN S IN COM ANALOG 2 ANALOG 2 TERMINAL BOARD ANALOG 1 ANALOG 1 D.GAIN D.GAIN A Power Terminal View A External GND Terminal Internal GND Terminal LINE/+ GND NEUT/ EARTH TERMINAL BOARD Power Terminal LINE/+ GND NEUT/ In case of non-explosionproof, GND terminal must be grounded either at external or internal terminal. PULSE + PULSE S OUT + S OUT S IN S IN COM ANALOG 2 + ANALOG 2 ANALOG 1 + ANALOG 1 D.GAIN + D.GAIN EARTH In case of explosionproof, EARTH Terminal shall be grounded to Class A earth grounding. 1 2 3 4 5 6 7 8 9 10 11 12 Terminal for Output Signals Remote Output Signal Connection Terminals Terminal No. Label Description Remarks Output signal Power 1 PULSE + Pulse output 2 PULSE 3 S OUT + Status output, open collector output 4 S OUT Normal: ON; Abnormal: OFF 5 S IN Status input (Form a contact input) 6 S IN COM 7 ANALOG2+ Analog output 2 8 ANALOG2 9 ANALOG1+ Analog output 1 10 ANALOG1 Drive gain output (for checking) LINE/+ Power (with DC power: +) GND Earth ground NEUT/ Power (with DC power: ) EARTH Class A earth ground work 11 D. GAIN + 12 D. GAIN 1. Use shielded twisted pairs AWG24-16 for output wiring. 2. Max. load resistance is 600Ω for analog output 1 and 2. 3. Pulse output (voltage pulse) transmission length is Max. 10m (at 10kHz) Max. 100m (at 1kHz) Max. 1km (at 100Hz) Be sure to earth ground at GND or EARTH terminal. Terminal identification between separate type sensor unit and transmitter Sensor to transmitter Terminal No. Label Description Remarks (Cable color) Black SHIELD Bundle BWN/RED, GRN/WHY, BLU/GRY, ORG/PUR/YEL shield wires. Brown (+) DRIVE Red ( ) DRIVE Flow tube drive output Orange TEMP B Temperature input Yellow TEMP b Temperature input Green (+) LPO Left position pickoff input Blue (+) RPO Right position pickoff input Purple TEMP A Temperature input Grey ( ) RPO Left position pickoff input White ( ) LPO Right position pickoff input Exclusive cable shall be used. Transmission length 200 meters max.

MassFlex Series PRODUCT CODE EXPLANATION Sensor unit Code No. Description Model C N ULTRA mass MK II Nominal size 0 0 A 1/4 Accuracy guarantee flow ranre0.4 to 60 g/min 0 0 1 1/4 Accuracy guarantee flow ranre1.5 to 225 g/min Configuration K MassFlex Series Material S S SUS316L Connection type 2 Screw connection Flange ratibg 0 Straight type (standard) (Coupling shape) 1 Elbow type (option) Pressure rating 0 Other than flanged connection Transmitter mounting construction R Separately-mounted type CT9401 Local mount transmitter (CT9401) Code No. Description Model C T 9 4 0 1 Local mount transmitter (CT9401) Construction T Applies to separately-mounted type CN001 6 20 to 30VDC Power supply 7 85 to 264VAC 50/60Hz M M Mass flow rate Analog 2 output M D Mass flow + Density M T Mass flow + Temperature M V Mass flow + Volume flow D T Density + Temperature Analog output (NOTE 1) V D Volume flow + Density V T Volume flow + Temperature M X Mass flow rate 1 output (Voltage pulse output) D X Density 1 output (Voltage pulse output) V X Volume flow 1 output (Voltage pulse output) 1 Mass flow voltage pulse (option) 2 Volume flow voltage pulse (option) Pulse output 3 Mass flow open collector pulse 4 Volume flow open collector pulse 0 Non-explosionproof Explosion-proof 1 TIIS (domestic explosionproof) (Temp. grade:sensor T3, Transmitter T4) 3 TIIS (domestic explosionproof) (Temp. grade:sensor T4, Transmitter T4) If voltage pulse output is chosen for pulse output, the analog output 2 is not available; select X in model code place. INSTALLATION The instrument can be installed either on the bench or on the wall. The following physical orientation is suggested. (In wall mounting, secure the instrument with bolts, using the mounting holes provided for the sensor unit.) Bench mount Wall mount

MassFlex Series PLEASE SUPPLY THE FOLLOWING INFORMATION WHEN YOU INQUIRE 1. Process fluid 2. Flow range 3. Fluid temperature 4. Operating pressure 5. Ambient temperature 6. Fluid flow direction Name SP. gr. Viscosity Slurry content in a slug flow % Max. Normal Full scale kg/min kg/h Max. C Normal C Min. C Max. MPa Normal MPa Min. MPa Max. C Min. C Left Right Right Left Bottom Top ( Top Bottom) 7. Nominal size 8. Required accuracy ± % of reading ± % of full scale 9. Process connection 10. CE marking Not required Required 3 11. Explosionproof 12. Power supply Not required TIIS ATEX Power V AC DC 13. Output specifications Pulse output Analog output Additional damping Alarm output Volt. pulse: [0]: 1.5V [1]: 15VDC min. Out. impedance: 2.2kΩ Open collector: Min. 10V to Max. 30VDC, 50mA Output frequency: Any point from 0.1 to 10000Hz at full scale 4 to 20mA DC Max. load: 600Ω 2 outputs from instant. flow rate (mass, volume), temp. or density (option) 0 to 200s. (variable) Slug flow 2 High g/ml Low g/ml 14.Companion receiver 15. Transmission length 16. Exclusive cable length. In case of a separated 17 type transmitter 18. In case of ATEX Cable gland 2 PED certificate of conformity 2, 3 Totalizer Indicator Recorder Flow controller Batch controller Computer Others Sensor unit ( ) m Transmitter ( ) m Receiving instrument In case of separate mounted type m (Max. 200m) Stand on type w/bracket and 2 U bolts Not required Required Not required Third-party agency Generated by OVAL 19. No. of units required 20. Application 21. Other considerations Special fluids such as slurries or of high viscosity, should be stated concretely and in detail. Option In determining compliance with the PED, items 1, 3, 4. 7, and 9 are essential. Describe them as precisely as possible. In certain cases, categorizing may possibly reveal failure to comply. The specification as of June, 2008 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: