Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Similar documents
ULTRASTAB IHF Precision Current Transducer

ULTRASTAB I U Precision

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

High Performance Current Transducer ITL 900-T = A

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

ULTRASTAB 864U-2000 CURRENT TRANSDUCER USER S MANUAL

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

LFR: flexible, clip-around current probe for use in power measurements

Data Sheet. Hall effect transducers, current and voltage

MCTS II Multi Channel Current Transducer System. Installation Manual

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

Voltage-to-Frequency and Frequency-to-Voltage Converter ADVFC32

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

Current Transducer CTSR 1-P = 1A

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

DS10000ULFS-10V/10kA

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT SENSOR HC6H300-S

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

Low Noise Variable Gain Low Frequency Voltage Amplifier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Variable-Gain High Speed Current Amplifier

Variable-Gain High Speed Current Amplifier

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

World-Class Accuracy & Measurement Range (40 Conventional Models)

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

Current transducer FHS 40-P/SP600

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DC Current Transducers 4XCT-100-C-HP User s Manual All Rights Reserved CAEN ELS s.r.l. Rev. 1.0 February 2017

Variable Gain Photoreceiver - Fast Optical Power Meter

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Variable Gain Photoreceiver Fast Optical Power Meter

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current transducer FHS 40-P/SP600

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Variable Gain Photoreceiver Fast Optical Power Meter

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

Variable Gain Sub Femto Ampere Current Amplifier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transducer for Measurement Bridges SCM90, SIGS15

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

Low Noise Variable Gain Low Frequency Voltage Amplifier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current Sensor: ACS750xCA-100

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

16-Bit ANALOG-TO-DIGITAL CONVERTER

DIN Thermocouple Conditioner MODEL 5M14(V)

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

Current clamps for AC current

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

Transcription:

ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first transducer of its class with transducer head and SMD based electronics integrated in one assembly. The model 866 is based on the proven high performance current measurement system in the Ultrastab program, and it is used as a current feed back element in precision power supplies or gradient amplifiers. It ranges 0-600A from DC to 100 khz with a temperature drift lower than 0.2 ppm/k. Powered with ±15V it produces an analog current of 400mA at 600 A primary current. Output noise and noise feed back to the main conductor are both extremely low, and electrostatic shielding ensures maximum iunity against external electrostatic fields. The 866 features Bandwidth DC to 100 khz Linearity better than 1 ppm Absolute calibration traceable to NIST Temperature drift less than 0.2 ppm/ C Noise feed-back to main conductor < 10 μv Resolution better than 0.05 ppm Bipolar, up to 400mA output current at 600A primary current Low noise on the output signal Applications Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies Manufacturer: Danfysik A/S Møllehaven 31 DK-4040 Jyllinge Denmark Tel. +45 4679 0000 Fax +45 4679 0001 danfysik@danfysik.dk www.danfysik.com North America Distributor: GMW Associates 955 Industrial Rd San Carlos, CA 94070 USA Tel. +1 650 802 8292 Fax +1 650 802 8292 sales@gmw.com www.gmw.com

Working principle The Ultrastab 866 Current Transducer system is a unique design, based on the zero-flux principle for galvanically isolated current measurement. With the primary current conductor through the transducer head center hole and current flowing, the electronics will generate a current in the built-in compensation winding counter-balancing the primary ampere turns. A very sensitive and extremely low noise detector circuit (patented) will detect when zero-flux is obtained, and an analog current signal will be generated at the output terminals in direct proportion to the primary current. Installation The Ultrastab 866 unit is fully self-contained, requiring only ±15V voltage supply. All connections via a 9-pole D-SUB socket. It can be installed in any orientation and has a high iunity to external magnetic and electrostatic fields. With the 866 delivered with the standard current transfer ratio of 1500:1, a 600A primary current will generate a 400mA compensation current. Wired up with a 2.5 Ohm Burden resistor, a 1V analog output signal will be available. If e.g. a max. 450A primary current shall be measured, the Burden resistor can be increased to 3.3 Ohm producing a 1V analog signal. From Fig. 1 on the attached installation data sheet it can be seen that the 866 can operate with higher resistance values of Burden resistors, but in order to get the best performance out of the Burden resistors, we recoend to keep the power loss as low as possible. Standard features The Ultrastab 866 is equipped with opto isolator for status interlock reading, and has a built-in scanning lock in circuit for automatic recovery to normal operation after overload condition. Optional features The Ultrastab 866 has a built-in free-running oscillator, which drives the zero flux detector circuitry. In cases where the application requires synchronization with external oscillator frequencies, e.g. in gradient amplifiers, the 866 can be delivered with a fibre optics trigger input for the frequency range 35 to 45 khz. FACT.Ultrastab866.0207-B Specifications are subject to change without notice. Accessories Mounting bracket 2.5 Ohm Burden resistor (4 x 10 Ohm//), 0.1%, Tc < 3 ppm/ C 9-pole D-sub with 2 m shielded cable ø25 busbar Ordering information standard 866 current transducer 866-BR 2.5 Burden resistor 866-BR 5.0 Burden Resistor 866-SC, 2m shielded cable 866-BB, busbar 866-MB, mounting bracket Optional 866-FIB, fibre optics trigger input

Ultrastab 866-600 Current transducer Last update: 15.03.2007 Parameter Symbol Condition Value Unit Primary current I p Nominal primary current ± 600 A Polarity Bipolar Secondary current I s Nominal secondary current ± 400 ma External burden resistor R b Max. R b, max 2.5 Ω Min. R b, min 0 Ω Current transfer ratio N 1500 Overload capacity Max. nondestructive overload I p, max @ 0.1s 500 %Ipn Min. overload trip value I p, trip 110 %Ipn DC accuracy Offset Initial I so < 20 ppm Drift vs. Temp. I so, temp < 0.2 ppm / K Drift vs. Time I so, time < 1 ppm / month Drift vs.supply voltage I so, supply < 1.5 ppm / % Transfer ratio Deviation N d < 2 ppm Deviation vs. Temp. N d, temp < 0.3 ppm / K Linearity Deviation X d < 1 ppm 0-10Hz < 0.05 ppm (RMS) 0-10kHz < 3 ppm (RMS) 0-50kHz < 10 ppm (RMS) Page 1 of 3

Ultrastab 866-600 Current transducer Last update: 15.03.2007 Parameter Symbol Condition Value Unit Dynamic response Slew rate di/dt 10-90% > 100 A / µs Bandwidth f ±3dB < 0.5% Ipn 100 khz Busbar noise U b Measured on primary cable, one turn DC - 50kHz < 10 µv RMS Busbar free zone Lenght l 150 Radius r 75 Test voltages Busbar to GND V t, b 5000 VAC RMS Power supply Supply voltage V s ± 5% ± 15 V Maximum quiescent current I q ± 200 ma Maximum current consumption I max ± 600 ma Operating environment Temperature T a 10-50 ºC Humidity RH a Noncondensing 20-80 %RH Storage environment Temperature T s 20-85 ºC Humidity RH s Noncondensing 20-80 %RH Page 2 of 3

Ultrastab 866-600 Current transducer Last update: 15.03.2007 Parameter Symbol Condition Value Unit Mechanical dimension Width Height Depth Weight (approx.) Inner hole diameter W H D m O 122 98 65 1 25 kg Notes: 1: All ppm figures refer to nominal current 2: Specifications are subject to change without notice Manufacturer: Danfysik A/S Møllehaven 31 DK-4040 Jyllinge Denmark Tel. +45 4679 0000 Fax +45 4679 0001 danfysik@danfysik.dk www.danfysik.com North America Distributor: GMW Associates 955 Industrial Rd San Carlos, CA 94070 USA Tel. +1 650 802 8292 Fax +1 650 802 8292 sales@gmw.com www.gmw.com Page 3 of 3

ULTRASTAB 866-600 INSTALLATION ULTRASTAB 866 D - SUB-9 Shielded Cable Part No: 88210 User Side 6 Brown Current Output 9 5 4 1 White Green Yellow Black +15V -15V 0V Rb 2 Red +VCC Optocoupler Output 8 Grey 7 Blue Imax = 6mA GND 3 Pink ON = Normal Operation Cable Shield Electrostatic Shielding The Wiring diagram shows: Re. Status: Normal Operation means: - Power connections +/- 15V present - Connection of Burden Resistor ( Rb ) - Zero detectors are working. - Connection of opto-coupler output ( status ) Output Current < 110%. 10 MAX BURDEN RESISTOR VOLTAGE 100.0 MAX BURDEN RESISTOR VALUE 8 80.0 VOLT 6 4 OHM 60.0 40.0 2 20.0 0 50 100 150 200 250 300 350 400 450 500 550 600 PRIMARY CURRENT (A) 0.0 50 100 150 200 250 300 350 400 450 500 550 600 PRIMARY CURRENT (A) Figure 2: The graph shows the maximum voltage that can be achieved across the externally connected Burden Resistor as a function of the Primary current. Figure 1: The graph shows the relationship between the Burden Resistor and the primary current. Manufacturer: Danfysik A/S Møllehaven 31 DK-4040 Jyllinge Denmark Tel. +45 4679 0000 Fax +45 4679 0001 danfysik@danfysik.dk www.danfysik.com North America Distributor: GMW Associates 955 Industrial Rd San Carlos, CA 94070 USA Tel. +1 650 802 8292 Fax +1 650 802 8292 sales@gmw.com www.gmw.com 1 866-600 Installation