Infra Red Interferometers

Similar documents
Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

INTERFEROMETER VI-direct

"SIMPLE MEASUREMENT, ADVANCED RESULTS"

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes

WaveMaster IOL. Fast and accurate intraocular lens tester

Testing Aspheric Lenses: New Approaches

3.0 Alignment Equipment and Diagnostic Tools:

OPTINO. SpotOptics VERSATILE WAVEFRONT SENSOR O P T I N O

Compact and Modular Interferometers

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

Industrial quality control HASO for ensuring the quality of NIR optical components

Typical Interferometer Setups

Why is There a Black Dot when Defocus = 1λ?

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L

Next generation IR imaging component requirements

Contouring aspheric surfaces using two-wavelength phase-shifting interferometry

Adaptive Optics for LIGO

Use of Computer Generated Holograms for Testing Aspheric Optics

Fabrication of 6.5 m f/1.25 Mirrors for the MMT and Magellan Telescopes

INTERPLANT STANDARD - STEEL INDUSTRY

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)

Collimation Tester Instructions

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

capabilities Infrared Contact us for a Stock or Custom Quote Today!

Computer Generated Holograms for Optical Testing

SpotOptics. The software people for optics OPAL O P A L

Tolerancing in Zemax. Lecture 4

Breadboard adaptive optical system based on 109-channel PDM: technical passport

Department of Mechanical and Aerospace Engineering, Princeton University Department of Astrophysical Sciences, Princeton University ABSTRACT

COLLIMATORS AND FOCUSERS RECEPTACLE STYLE

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

OMI-SWIR. SpotOptics FAST & ACCURATE WAVEFRONT SENSOR S W I R

Compact Dual Field-of-View Telescope for Small Satellite Payloads

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

SpotOptics. The software people for optics L E N T I N O LENTINO

Imaging Photometer and Colorimeter

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

Rough surface interferometry at 10.6 µm

The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces

USE OF COMPUTER- GENERATED HOLOGRAMS IN OPTICAL TESTING

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Sub-nanometer Interferometry Aspheric Mirror Fabrication

Computer Generated Holograms for Testing Optical Elements

Optical Design with Zemax for PhD - Basics

ATLAS Corneal Topography System

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit,

Why select a BOS zoom lens over a COTS lens?

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Spotlight 150 and 200 FT-IR Microscopy Systems

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

An Off-Axis Hartmann Sensor for Measurement of Wavefront Distortion in Interferometric Detectors

Large-Area Interference Lithography Exposure Tool Development

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Typical requirements of passive mm-wave imaging systems, and consequences for antenna design

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

Ocular Shack-Hartmann sensor resolution. Dan Neal Dan Topa James Copland

INFRARED IMAGING-PASSIVE THERMAL COMPENSATION VIA A SIMPLE PHASE MASK

Bringing Answers to the Surface

The ASTRI SST-2M Illuminator

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Vibration-compensated interferometer for measuring cryogenic mirrors

CHARA AO Calibration Process

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

Be aware that there is no universal notation for the various quantities.

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Cardinal Points of an Optical System--and Other Basic Facts

Explanation of Aberration and Wavefront

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Dynamic beam shaping with programmable diffractive optics

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

It s Our Business to be EXACT

Handbook of Optical Systems

Understanding Optical Specifications

Optical Precision. Optimal Outcome.

Features. Applications. Optional Features

Aberrations and adaptive optics for biomedical microscopes

Paper Synopsis. Xiaoyin Zhu Nov 5, 2012 OPTI 521

Testing Aspherics Using Two-Wavelength Holography

Proposed Adaptive Optics system for Vainu Bappu Telescope

Will contain image distance after raytrace Will contain image height after raytrace

Design of the cryo-optical test of the Planck reflectors

OPTOCRAFT Unleashed wavefront technology

Dario Cabib, Amir Gil, Moshe Lavi. Edinburgh April 11, 2011

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Atlantic. Industrial High Power Picosecond Lasers. features

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes

Optics of Wavefront. Austin Roorda, Ph.D. University of Houston College of Optometry

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Laser Diode Mounting Kits

Laser Speckle Reducer LSR-3000 Series

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department. 2.71/2.710 Final Exam. May 21, Duration: 3 hours (9 am-12 noon)

Shack-Hartmann wavefront sensor: technical passport

Transcription:

Infra Red Interferometers for performance testing of infra-red materials and optical systems Specialist expertise in testing, analysis, design, development and manufacturing for Optical fabrication, Optical Assemblies, defense related engineering disciplines including sensors, systems, and electronics. MANUFACTURING Solutions A wealth of technical experience in electrical, mechanical, electromechanical and electro optical systems is available for the assembly and test of a variety of complex subsystems. Production operations and logistics expertise is supplemented by project management, manufacturing and process engineering skills in order to ensure cost effective delivery. promotes a extensive range of specialist testing, analytical, design, manufacturing, and evaluation facilities to a wide market across the Optics, Optical Assemblies, Laser diagnostics, aerospace and defence industries. NextGenn has several programmes in the industry and offers unrivalled capability in key technologies that are relevant to the Optics fabrication, Testing of Optical Assemblies, Laser diagnostics, aerospace and defence and a host of commercial industries. NextGenn offers access to this wealth of expertise on a commercial, contract basis through three major disciplines: Testing, Imaging and Manufacturing Solutions.

INFRARED II Dual Waveband IR Interferometer The INFRARED II dual waveband Twyman-Green unequal path Interferometer available with a choice of lasers operating at LWIR 10.6 microns wavelength, in the MWIR 3.39 micron wavelength range which allows fringes to be obtained quickly and easily with excellent signal-to-noise with the facility of a common interferometer system for both the wave bands. We offer two options for Co2 Laser : One option uses Co2 Laser with 12 tunable lines (10.3-10.8 microns), this can be fixed at 10.6 micorns and Second Option uses Co2 Laser with 45 tunable lines(9.1-10.9 microns). The Base unit includes IR remote control and 633nm external laser alignment source. INFRARED II dual waveband Twyman-Green interferometers have been designed to be rugged, easy-to-use instruments that can be used for development, test, production, quality control or research applications and are fully supported with a comprehensive range of optical and mechanical accessories and static and phasemeasuring fringe analysis software options for the accurate measurement of wavefront aberration of thermal imaging lenses, optical homogeneity of infra red materials and flatness of optical surfaces. The construction of this system combined with a fast warm-up time means that fringe images can be quickly and easily produced with no focus drift. All instruments feature a focal plane array camera which is much more sensitive than previous cameras and has significantly reduced noise, allowing high quality images of fringes to be acquired quickly, easily and with no focus drift. When used with phase shifting fringe analysis

software, the acquisition of fringes is much more reliable. The phase shifting technique used allows the highest degree of precision and enables full use of standard accessories. The INFRARED-II dual waveband system operates at both 3-5 micron band using 3.39 micron HeNe laser source and at 10.6 using a stabilized CO2 waveguide laser source operating at 10.6 microns. Alternative lasers are available for different wavelengths. Both 3.39 micron and 10.6 micron Lasers along with alignment Laser is housed inside a single housing to make the system compact and easy to use. The INFRARED-II dual IR using a factory-fitted phase shifting accessory employs a piezo-electric transducer which moves the reference mirror in the interferometer. Successive frames of video output can then be analyzed to provide the greatest possible accuracy in the measurement using our advanced PC and μshape Fringe Analysis Software. As precision non-contact instruments, the INFRARED II Dual IR interferometers provide rapid and accurate measurement of wavefront distortion through IR systems and components. Their operating wavelengths allow for the evaluation of high specification IR lens assemblies, producing interference fringes that indicate the degree of aberrated performance. Their associated fringe analysis software enables detailed performance analysis of even the most complex of lenses. It features a focal plane array camera which is much more sensitive than previous cameras and has significantly reduced noise, allowing high quality images of fringes to be acquired quickly, easily and with no focus drift. When used with phase shifting fringe analysis software, the acquisition of fringes is much more reliable. This is of particular importance in the 3-5 micron wavelength range where the lasers are generally of low power. This technical excellence of the system allows optical design services, optical testing, diamond machining and sub-assembly manufacturing. Each instrument comes with a comprehensive operating manual and is backed by a one year guarantee plus a choice of technical field service and support packages. The INFRARED II Dual IR interferometer systems is configured in a Twyman Green optical configuration and have an integral co-linear visible HeNe laser at 3.39 micron and a stabilised CO2 waveguide laser source operating at 10.6 microns included that provides the user with a rapid and accurate alignment system and are designed to provide versatile testing capabilities.

KEY BENEFITS of INFRARED II Dual IR Interferometer: Portable and compact Easy to set up and operate Provide remote control operation Non-contact and precise Transmitted wavefront measurement for IR materials/systems Compatible with a wide range of standard accessories Practical, versatile and affordable Specifications Configuration Description Acquisition Mode Alignment Mode Wavelengths Maximum Output Clear Aperture Maximum Cavity Length Polarization Pupil Focus Range Pupil Magnification Camera Motorized Controls Additional Option Computer System Operating System INFRARED II Dual IR Interferometer Dual waveband Twyman-Green Unequal Path Interferometer Temporal Phase Shifting Integral co-linear visible HeNe laser 3.39 um & 10.6 microns (others available) Test Lasers : <4mW at MWIR waveband and <400mW at LWIR waveband both housed in single housing along with Alignment Laser: < 45 mw at 633 nm 50 mm (Expandable with accessories) >30 m Linear +/- 10 mm (higher focus ranges are available as custom made) 1Xto 3X High Resolution dual waveband 320x240 uncooled ferroelectric focal plane array System wavelength, Zoom, Focus, Tip-Tilt Reference Mirror Beam Attenuation(manual) for low reflectivity test surfaces Minimum Dual Core 2 GHz processor, 1GB RAM, 160GB Hard drive, CDRW, DVDRW, 19 in LCD monitor, keyboard, mouse, frame grabber Windows-7 OR Windows XP

System Software Fringe detection System Transmission >/= 75% Display System Performance Specifications: μshape and FastFringe μshape Phase Shifting data acquisition FastFringe instantaneous data acquisition Fringe contrast controlled via camera and frame grabber settings Reference generation, subtraction, data averaging, masking 2D and 3D surface maps Zernike / Seidel / Slope / Geometric / Fourier Analysis Absolute sphere, aspheric analysis, prism & corner cube analysis, multiple aperture analysis Focal plane array with fringe contrast adjustments CCIR compatible or as specific user requirements Accuracy (PV) Repeatability (PV) Precision Acquisition Rate Dimensions Weight Power Conumption Temperature Range wavefront<λ/50 P-V with reference calibration and subtraction surface deviation<λ/100 P-V with reference calibration and subtraction wavefront λ/100 P-V, λ /200 rms surface deviation λ/200 P-V, λ/400 rms λ/1000 rms μshape 0.16secs to 1.33secs FastFringe 20millisecs 675mm (l) x 260mm (w) x 280 mm (h) 35 kg approx 720Watts Operational : 10 30 C, stability +/-2 C, non-condensing Storage: 5 45 C, non-condensing Phase shift software: Phase shift analysis can improve accuracy by capturing the fringes with several different phases of the reference beam. This permits calculation of absolute phase for every pixel within the pupil, which increases accuracy and repeatability of measurements to around lambda/100, and allows the sense of the fringe perturbation to be identified as a wavefront retardation or advance. The technique involves using a piezo transducer to move the reference optic by around lambda/2 and utilizing dedicated phase shift analysis software to provide full analysis of circular, multiple, low contrast and nulled fringes.

We can offer software which is extremely versatile, and features masking facilities which enables data to be acquired using a variety of transparent or opaque masks as useradjustable circles, ellipses, rectangles and polygons. This allows information to be obtained from different parts of the optical surface under test. These display formats can be extended to all measured data, such as aberration fields, MTF and slope field. Results can be displayed directly in terms of ISO and DIN standards. Phase measuring interferometry is a more accurate technique than static fringe analysis since it offers higher density and uniform sampling of the interference pattern, and better phase resolution. Specification: Piezo mirror control Phase shifting control Vision Fringe acquisition and interpretation software Frame grabber PC card & PC DAC card Key Features : Software operates within Windows. Capability to evaluate both components and systems. Full analysis of circular, multiple, low-contrast and null fringes. Macro programming facility allows repetitive testing routines to be set up. Reference subtract.

Static Fringe Analysis: A variety of static fringe analysis software packages is available. Static fringe analysis typically offers an accuracy of around lambda/20 and has the benefit that the software results can be verified manually for simple peak to valley measurements. Software offers far more sophisticated analysis including calculation of the rms wavefront deviation, and other derived functions such as the Strehl Ratio, MTF, Point Spread Function and Encircled Energy Function. The wavefront shape is often approximated by fitting Zernike coefficients to the available data, enabling the calculation of Seidel Aberrations. The software can also flag pass/fail criteria based on irregularity, power, peak to valley wavefront value and rms wavefront aberration. Key Features : Pass/fail criteria; irregularity, power, PV, rms. Low cost analysis of open or closed fringes. Full wavefront analysis including MTF, PSF, slope error. Zernike analysis up to 49 terms & Reference subtract.

INFRARED II Dual IR Standard Accessories: Aperture converters to increase the 35mm output beam diameter Reference flats (λ/20) Transmission spheres (λ/10) Reference spheres (λ/20) Collimating lenses Off-axis parabolas Attenuators Precision mounts Vertical configurations Upward/downward looking options Static/ phase fringe analysis system Phase shifting accessory Refractive collimator (100mm aperture) Beam expander 150mm/200mm Beam expander 300mm Transmission sphere f/1 Transmission sphere f/2 Transmission sphere f/4 Transmission sphere f/8 Compact precision mount 2 axis (tilt) Compact precision mount 5 axis Large precision mount 2 axis (tilt) Large precision mount 3 axis (tilt) Large precision mount 5 axis (tilt xyz) We encouraged you to discuss your application with us and we can then accordingly offer several custom made accessories to support your project.

Reflective Beam Expander The reflective beam expander accessory is designed for the analysis of large optics using the INFRARED range of infrared interferometers and can be used both in the 3-5 micron and 8-12 micron wavebands. The unit is produced in collaboration with Optical Surfaces Ltd and features a Newtonian configuration not a Galilean configuration to provide an intermediate focused image for efficient relaying of optical pupils, which is essential at longer infrared wavelengths. The reflective beam expander is a robust, standalone unit which can be bolted to an optical bench with height adjustment for fine alignment. It contains a matched pair of permanently aligned aluminum mirrors, complete with magnesium fluoride protective coatings. It has a wave front accuracy of λ/10) in the 3-5 micron waveband, with output apertures of 150 mm and 200 mm as standard, although other sizes are available. The input aperture of 30 mm is matched to the INFRARED Interferometers output aperture. For further information about Infra-red interferometers and their applications please contact our sales department. 13/F, Culturecom Centre, 47 Hung To Road, Kwun Tong, Kowloon,Hong Kong FAX: +852 8161 7033 Email: sales@nextgenn.net Web: www.nextgenn.net