DIGITAL EARTH FAULT RELAY

Similar documents
DIGITAL EARTH FAULT RELAY

STATIC EARTH FAULT RELAY

Earth Fault Relay EFSPL-1A/5A

RESTRICTED EARTH FAULT RELAY

MOTOR PROTECTION RELAY

STATIC PHASE FAILURE RELAY

DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Power System Protection Manual

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

Electrical Protection System Design and Operation

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

DEPARTMENT OF ELECTRICAL ENGINEERING BENGAL ENGINEERING AND SCIENCE UNIVERSITY, SHIBPUR

Phase and neutral overcurrent protection

POWER SYSTEM II LAB MANUAL

Protective Relays Digitrip 3000

SPAD 346 C Stabilized differential relay

3 Phase Induction Motor Protection using Numerical Relay

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

Stabilized Differential Relay SPAD 346. Product Guide

Power systems Protection course

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Earth Fault Protection

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

Multimeter 500CVD21 RTU500 series

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

Overcurrent Protective Relays

A NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG

STATIC UNDER-OVER VOLTAGE RELAY VD SERIES

Type VDG 13 Undervoltage Relay

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Relay Types and Applications Dr. Sasidharan Sreedharan

Protection and control VIP300. Technical manual

PD300. Transformer, generator and motor protection Data sheet

EE402-Protection and Switchgear Dept. of EEE

Type VAEM 22 Negative Potential Biasing Relay

Instantaneous Overcurrent Relay

INSTRUCTION MANUAL. AQ F3x0 Feeder protection IED

Substation Monitoring with TESLA

ASHIDA Numerical OC/EF Protection Relay

EEL 3086 SWITCHGEAR AND PROTECTION EXPERIMENT 2 DIFFERENTIAL PROTECTION OF A THREE-PHASE TRANSFORMER

Protection and control. Sepam range Sepam 2000 Metering and protection functions

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

Overcurrent relays coordination using MATLAB model

User s manual and Technical description. Self-Powered Feeder Protection REJ603

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

Type CAEM 21 Battery Earth Fault Relay

SPAJ 135 C. Combined overcurrent and earth-fault relay SPAJ 135 C. User s manual and Technical description. U aux V ~ V.

Relion 605 series. Self-Powered Feeder Protection REJ603 Application manual

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

MRS1 - Negative sequence relay. Manual MRS1 (Revision A)

Transformer Protection

POWER SYSTEM PRINCIPLES APPLIED IN PROTECTION PRACTICE. Professor Akhtar Kalam Victoria University

XD1-T - Transformer differential protection relay

2C73 Setting Guide. High Impedance Differential Relay. Advanced Protection Devices. relay monitoring systems pty ltd

Burdens & Current Transformer Requirements of MiCOM Relays. Application Notes B&CT/EN AP/B11. www. ElectricalPartManuals. com

ASHIDA Numerical 3OC + 1EF Protection Relay

Testing of Circuit Breaker and over Current Relay Implementation by Using MATLAB / SIMULINK

Generator in a power station requires different type of

3 Pole high impedance differential relay 7VH83

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

OVERCURRENT PROTECTION RELAY GRD110

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

ASHIDA Numerical Directional 3OC + 1EF Protection Relay

Numerical Multi-Function Motor Protection Relay RHO 3. Operation & Maintenance Instruction Manual

2V68-S User Guide. CT Supervision And Shorting Relay. User Guide

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213

High-Tech Range. C&S Protection & Control Ltd. MRI1- Digital multifunctional relay for overcurrent protection SELECT/RESET I P I Q I> ENTER CHAR I>

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy


EARTH LEAKAGE RELAY RELAY FOR PERMANENT CONTROL OF THE MCCB S TRIPPING CIRCUIT AND ACTUATOR FOR SAFETY CIRCUITS

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Application and Commissioning Manual for Numerical Over Current Protection Relays Type MIT 121/131 CONTENTS PAGE APPLICATION 2-4 INSTALLATION 5-11

9 Overcurrent Protection for Phase and Earth Faults

Generator Protection GENERATOR CONTROL AND PROTECTION

EASUN REYROLLE LIMITED

Protection and control. Sepam range Sepam 2000 Testing

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

SPAD 346 C. Stabilized Differential Relay. User s manual and Technical description SPAD 346 C V ~ V. f n SPCD 3D53 SPCJ 4D28

UPGRADING SUBSTATION RELAYS TO DIGITAL RECLOSERS AND THEIR COORDINATION WITH SECTIONALIZERS

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

CableTroll 2410 PN: /03. User Manual

3. (a) List out the advantages and disadvantages of HRC fuse (b) Explain fuse Characteristics in detail. [8+8]

SPAE 010, 011 High Impedance Protection Relay

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Replacement solution

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Transcription:

DIGITAL

IDMT / DEFINITE TIME / INSTANTANEOUS Features ŸCompact ŸIDMT (4 IEC curves), Definite Time & Instantaneous ŸWide setting ranges ŸFully digital acquisition & processing of data ŸWide operating voltages ŸLCD display of operated current & fault current ŸRugged and Tropicalized design Applications ŸEarth Fault Protection for Generators / Alternators ŸEarth Fault Protection for Transformers & Feeders Specifications SPECIFICATIONS Auxiliary Voltage Frequency Neutral or Summation CT rated Current-In Burden on CT Sensitivity Settings Plug Setting Range(PS) Definite Time Settings in Sec IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) 85-275 V AC/DC or 50-550V AC/DC 50Hz 1A / 5A ( Field Selectable ) <0.2VA PS Range : (5%-80%) of In. in steps of 5% 0.0-20 Sec. (200 Steps) in steps of 0.10 Sec. IDMT Curves 4 IDMT Curves : Normal Inverse (NI) 1.3 Sec 3.0 Sec Long Time Delay (LTD) Time Setting Multiplier (TMS) (0.1-20.) in steps of 0.05 High Set Enable/Disable Option High Set Time for High Set Operation CBCT/ZCT size for EFR Contact Capacity (A) Contact type Available (0.5-16) In. in steps of 0.1 (0.0-1.6) Sec. in steps of 0.1 Sec Circular: 40mm,65mm,100mm,150mm,200mm,250mm&300mm with Secondary 1A only 8A@250V AC 8A@30V DC NC-C-NO Two change over

IDMT / DEFINITE TIME / INSTANTANEOUS Operating Temperature ( C) -5 C --- +55 C Standard IEC - 60255 Relay Setting Mode Setting through push button Selection of the relay rating- 5A or 1A (In) PS - selection Curve Selection TMS - selection for IDMT Time - for DEFT Relay TEST RESET Display/Indication Back-Lit LCD display Two line 8 characters Trip value of the current w.r.t. Secondary of CT Set PS value. Red LED-DEFT/IDMT trip Relay Test Facility Available through push button Mounting Type Flush Din/Surface Dimensions in mm Flush : 96 x 96 x 70 Din : 80 x 95 x 75 (W x H x D) Panel cut out in mm (Flush type) 90 x 90 + 0.1 mm Description PROK DEVICES PVT LTD an ISO 9001-2008 company introduces DIGITAL MICROPROCESSOR / MICROCONTROLLER BASED IDMT / DEFINITE TIME / INSTANTANEOUS (EFR).It is a current sensing device which is tropicalised professionally designed and tested for protection of Generators, Transformers and Feeders. Prok dv's make IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) can be employed with various earth fault protective schemes, which are explained in brief with figures. The magnitude of the earth fault current depends on the fault impedance and invariably the fault impedance for earth fault is higher than that for phase faults, hence the earth fault current is low compared to the phase fault currents. The fault impedance depends on the system parameter and also on type of earthing. The neutral may be solidly grounded, grounded through resistance or reactance. The unit has LCD for displaying the fault current (at the time of tripping) and setting values (curves, plug setting & TMS). The LEDs are provided for indicating power ON status and to indicate IDMT or DEFINITE TIME or INSTANTANEOUS mode operation. Key pads are provided for easy setting/changing of the parameters.the design is tropicalised and rugged. The IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) measure the current using sampling technique. The analog current signal obtained from the protection CT is stepped down using interposing CT. Current signal is then applied to signal conditioning circuit using the buffer. Signal is then level shifted by adding DC level. This uni-polar signal is applied to ADC of the processor.

IDMT / DEFINITE TIME / INSTANTANEOUS The ADC samples the signal in every cycle. The samples are used to determine the magnitude of the signal. The calculated amplitude value is checked with the set value at every sample instant. When the evaluated value is greater than the set (Current) the algorithm evaluates the trip time. If the operating condition is met the trip initiating signal is issued after the elapse of calculated tripping time. Figure A Shows how an Earth Fault Relay (EFR) can be energized by a residual current, in this method the secondary 3 CT currents, by summation technique Ir, Iy & Ib of three different phases are connected in parallel. The vectorial sum of three current ie (Ir+ Iy + Ib ) is zero under normal condition. During the occurrence of earth fault the residual current is non-zero and when it exceeds the pick-up value (Site Selected), the Earth Fault Relay(EFR) trips. Theoretically during balanced load conditions the Earth Fault Relay (EFR) carries no current hence its current, setting may be any value greater than zero, but in practice such ideal system do not exist. Using the summation techniques it is possible to detect Earth Fault current in the Electrical power system, the choice of summation can be made according to site condition, Economic condition and the Electrical protection scheme. Figure B Shows schemes for IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) used for protection of Transformer and Generator. On occurrence of earth fault, zero sequence current flows through the neutral, in-turn actuating the earth fault relay (EFR). Figure C shows a scheme with IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) which utilized a special type of C.T., called core balance current transformer (CBCT/ZCT) which is toroidal in nature, under normal condition of 3 phase to phase faults the current in the toroidal secondary is zero. During earth fault the reflected zero sequence unbalance current flows in the CBCT/ZCT secondary energizing the Earth Fault Relay (EFR).

IDMT / DEFINITE TIME / INSTANTANEOUS WIRING DIAGRAM FOR DIGITAL MICROPROCESSOR / MICROCONTROLLER BASED IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) (MPEFSPL) FLUSH MOUNTING MCCB /ACB / WIRING DIAGRAM FOR DIGITAL MICROPROCESSOR / MICROCONTROLLER BASED IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) (DMPEFSPL) DIN MOUNTING MCCB /ACB /

IDMT / DEFINITE TIME / INSTANTANEOUS MECHANICAL DIMENSION OF DIGITAL MICROPROCESSOR / MICROCONTROLLER BASED IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) (MPEFSPL) FLUSH MOUNTING MECHANICAL DIMENSION OF DIGITAL MICROPROCESSOR / MICROCONTROLLER BASED IDMT / DEFINITE TIME / INSTANTANEOUS (EFR) (DMPEFSPL) DIN MOUNTING

IDMT / DEFINITE TIME / INSTANTANEOUS ISO 9001-2008 Prok Devices Private Limited SIMHADRI, No.2930, 14 th Cross, Banashankari II nd Stage, Off K.R. Road, Bengaluru-560070 Karnataka India Tel:+91 80 43487777/26760718/26761719 Fax:+91 80 26761720 Email: info@prokdvs.com