Quantum measurements with an amplitude-squeezed-light beam splitter

Similar documents
Generation and applications of amplitudesqueezed states of light from semiconductor diode lasers

Controlled dense coding for continuous variables using three-particle entangled states

Optoelectronic Oscillator Topologies based on Resonant Tunneling Diode Fiber Optic Links

Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers

Observation of twin beam correlations and quadrature entanglement by frequency doubling in a two-port resonator

Characteristics of absorption and dispersion for rubidium D 2 lines with the modulation transfer spectrum

All-Optical Clock Division Using Period-one Oscillation of Optically Injected Semiconductor Laser

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

3 General Principles of Operation of the S7500 Laser

Frequency Noise Reduction of Integrated Laser Source with On-Chip Optical Feedback

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

A Narrow-Band Tunable Diode Laser System with Grating Feedback

Stable, 12 W, continuous-wave single-frequency Nd:YVO 4 green laser polarized and dual-end pumped at 880 nm

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

R. J. Jones Optical Sciences OPTI 511L Fall 2017

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

Multi-wavelength laser generation with Bismuthbased Erbium-doped fiber

A CW seeded femtosecond optical parametric amplifier

Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS

Single frequency Ti:sapphire laser with continuous frequency-tuning and low intensity noise by means of the additional intracavity nonlinear loss

High-frequency tuning of high-powered DFB MOPA system with diffraction limited power up to 1.5W

SUPPLEMENTARY INFORMATION

Lecture 6 Fiber Optical Communication Lecture 6, Slide 1

Increasing the output of a Littman-type laser by use of an intracavity Faraday rotator

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

RADIO-OVER-FIBER TRANSPORT SYSTEMS BASED ON DFB LD WITH MAIN AND 1 SIDE MODES INJECTION-LOCKED TECHNIQUE

BROAD-BAND rare-earth-doped fiber sources have been

A novel tunable diode laser using volume holographic gratings

Multi-format all-optical-3r-regeneration technology

An optical transduction chain for the AURIGA detector

3550 Aberdeen Ave SE, Kirtland AFB, NM 87117, USA ABSTRACT 1. INTRODUCTION

Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection

~r. PACKARD. The Use ofgain-switched Vertical Cavity Surface-Emitting Laser for Electro-Optic Sampling

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

Communication using Synchronization of Chaos in Semiconductor Lasers with optoelectronic feedback

Coherent power combination of two Masteroscillator-power-amplifier. semiconductor lasers using optical phase lock loops

arxiv:quant-ph/ v1 22 Jul 1999

CONTROLLABLE WAVELENGTH CHANNELS FOR MULTIWAVELENGTH BRILLOUIN BISMUTH/ERBIUM BAS-ED FIBER LASER

Optical phase-locked loop for coherent transmission over 500 km using heterodyne detection with fiber lasers

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Supplementary Figures

S-band gain-clamped grating-based erbiumdoped fiber amplifier by forward optical feedback technique

No. 9 Influence of laser intensity in second-harmonic detection the 2ν3 band located at μm. There are several lines labelled as P, Q, a

Installation and Characterization of the Advanced LIGO 200 Watt PSL

Ultrahigh precision synchronization of optical and microwave frequency sources

Setup of the four-wavelength Doppler lidar system with feedback controlled pulse shaping

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides

UNMATCHED OUTPUT POWER AND TUNING RANGE

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Active mode-locking of miniature fiber Fabry-Perot laser (FFPL) in a ring cavity

HOMODYNE and heterodyne laser synchronization techniques

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

Laser Locking with Doppler-free Saturated Absorption Spectroscopy

High collection efficiency MCPs for photon counting detectors

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Chapter 3 Experimental study and optimization of OPLLs

Linear cavity erbium-doped fiber laser with over 100 nm tuning range

High brightness semiconductor lasers M.L. Osowski, W. Hu, R.M. Lammert, T. Liu, Y. Ma, S.W. Oh, C. Panja, P.T. Rudy, T. Stakelon and J.E.

PHASE TO AMPLITUDE MODULATION CONVERSION USING BRILLOUIN SELECTIVE SIDEBAND AMPLIFICATION. Steve Yao

Spurious-Mode Suppression in Optoelectronic Oscillators

Cost-effective wavelength-tunable fiber laser using self-seeding Fabry-Perot laser diode

Ring cavity tunable fiber laser with external transversely chirped Bragg grating

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

The Theta Laser A Low Noise Chirped Pulse Laser. Dimitrios Mandridis

Application Instruction 002. Superluminescent Light Emitting Diodes: Device Fundamentals and Reliability

Multiwavelength Single-Longitudinal-Mode Ytterbium-Doped Fiber Laser. Citation IEEE Photon. Technol. Lett., 2013, v. 25, p.

Recent Progress in Pulsed Optical Synchronization Systems

Tera-Hz Radiation Source by Deference Frequency Generation (DFG) and TPO with All Solid State Lasers

White Paper Laser Sources For Optical Transceivers. Giacomo Losio ProLabs Head of Technology

Vertical External Cavity Surface Emitting Laser

Module 12 : System Degradation and Power Penalty

Bit error rate and cross talk performance in optical cross connect with wavelength converter

LOPUT Laser: A novel concept to realize single longitudinal mode laser

Optical Amplifiers (Chapter 6)

Stable dual-wavelength oscillation of an erbium-doped fiber ring laser at room temperature

Waveguide-based single-pixel up-conversion infrared spectrometer

Measurements of linewidth variations within external-cavity modes of a grating-cavity laser

Instructions for the Experiment

S.M. Vaezi-Nejad, M. Cox, J. N. Copner

Dispersion measurement in optical fibres over the entire spectral range from 1.1 mm to 1.7 mm

A new picosecond Laser pulse generation method.

Photonic Microwave Harmonic Generator driven by an Optoelectronic Ring Oscillator

taccor Optional features Overview Turn-key GHz femtosecond laser

Pound-Drever-Hall Locking of a Chip External Cavity Laser to a High-Finesse Cavity Using Vescent Photonics Lasers & Locking Electronics

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

Keysight Technologies Using a Wide-band Tunable Laser for Optical Filter Measurements

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

Differential measurement scheme for Brillouin Optical Correlation Domain Analysis

Self-organizing laser diode cavities with photorefractive nonlinear crystals

Linearity Improvement Techniques for Wireless Transmitters: Part 1

SECOND HARMONIC GENERATION AND Q-SWITCHING

Laser Beam Analysis Using Image Processing

Optical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p.

Symmetrically coated pellicle beam splitters for dual quarter-wave retardation in reflection and transmission

Laser stabilization and frequency modulation for trapped-ion experiments

Transcription:

Quantum measurements with an amplitude-squeezed-light beam splitter Junxiang Zhang, Tiancai Zhang, Ruifang Dong, Jing Zhang, Changde Xie, and Kunchi Peng Quantum measurement of amplitude fluctuation is performed by the injection of 2.5-dB amplitudesqueezed light produced by a quantum-well laser into the dark port of a beam splitter as the meter wave. It is shown that the measurements satisfy the criteria of quantum nondemolition measurement. The measured transfer coefficient and the quantum-state preparation ability are 1.07 and 0.8, respectively. 2001 Optical Society of America OCIS codes: 270.6570, 270.2500, 140.2020. Quantum nondemolition QND measurement proposed first by Braginsky 1 is an approach for nondestructive measurement of observable quantum; that is, it allows one to measure observable quantum without disturbing it. The strategies are to indirectly measure the meter wave, which is coupled to a signal wave through some specially designated interaction, and then to deduce the desired information on the observable signal wave from the measurement without disturbing the signal wave. A number of experimental attempts of implementing QND measurements were performed when a signal beam was coupled to a meter beam via an optically nonlinear medium. 2 4 Other coupling methods such as optoelectrical and electromechanical coupling were also applied to perform the QND measurement. 5 7 Recently the long-standing challenge for repeated QND measurements of a continuous variable was successfully mastered 8,9 with a monolithic dual-port degenerate optical parametric amplifier. It is well known that a beam splitter is the simplest and most popular optical device in optical systems. Early it has been demonstrated theoretically that a beam splitter with a squeezed-light input can be used to implement the QND measure- The authors are with the Institute of Opto-Electronics, Shanxi University, The Key Laboratory of Quantum Optics, Ministry of Education, China, Taiyuan 030006, China. Junxiang Zhang s e-mail address is zjx1966@yahoo.com.cn. K. Peng s e-mail address is kcpeng@sxu.edu.cn. Received 14 February 2001. 0003-6935 01 325949-05$15.00 0 2001 Optical Society of America ment. 10,11 Two such QND experiments have recently been performed in which the beam splitter was used to couple a signal wave to a nonclassical meter wave that was a squeezed vacuum wave 12 or a twin beam of intensity quantum correlation. 13 Because a squeezed vacuum wave or a twin beam is generated from an optical parametric process, the optical systems in these experiments are quite complex. The amplitude-squeezed light generated from a pump-noise-suppressed laser diode LD can be obtained from a compact device with intermediate optical power, large squeezing bandwidth, and rich wavelength. With some line-narrowing techniques such as injection-locking or external optical feedback, 14 16 the amplitude squeezing of a LD has been improved to 3 db. Several experiments of applying amplitude-squeezed light from a LD to improve the sensitivities of spectroscopic measurement have been completed. 17 19 But so far, the amplitude-squeezed light from a LD has not been used in a quantum measurement that meets QND criteria. In this paper we present the realization of a back-action-evasion measurement of the amplitude component of the signal by coupling it with the amplitude-squeezed meter wave generated from a LD on a beam splitter that acts as a QND coupler. The measured results fulfill the criteria of QND detection in the quantum region. First, we simply present the operation principle of the device. Assume that a beam splitter of power transmission T and reflectivity R 1 T couples the detected signal wave to the meter wave. The relation between the input X in s for the signal wave and X in m for the meter wave and the output X out s for the 10 November 2001 Vol. 40, No. 32 APPLIED OPTICS 5949

signal wave and X out m for the meter wave quadrature amplitudes at the beam splitter is expressed as 12 R T in X s X m out T R X s X m in. (1) According to the same procedure used in Ref. 13, we can easily deduce the transfer coefficient T T s T m and the normalized condition variance of the device V s m from their original definition, 20,21 T T s T m SNR s out SNR m out SNR s in, (2) V s m V s out 1 C 2 X s out X m out, (3) where T s and T m are the transfer coefficients of signal and meter waves, respectively, the signal-to-noise ratio SNR is defined as the ratio of the intensity of a small modulation at a given frequency 21 MHz for our scheme for the quadrature amplitude X by the quadrature amplitude noise power at the same frequency V S M in out SNR X 2 V X. is the fluctuation variable of the input output signal wave or the input output meter wave, and C 2 X out s X out m is the normalized correlation function between the output signal and meter waves. Both the transfer coefficient and the conditional variance are used for quantifying the properties of a QND device. T characterizes the quality of the QND device as an quantum optical tap. The quantumstate preparation ability of the QND device can be conveniently evaluated by the conditional variance V s m. If the input signal and meter beams are shot-noise limited, then the standard quantum limits T s T m 1 and V s m 1 are created. When with the squeezed meter input we have 2 T s T m 1, the device operates as the quantum optical tap, 21 and meanwhile V s m 1 means the readout from the output meter wave gives some exact information about the outgoing signal wave. 21 We can calculate from Eqs. 2 and 3 the transfer coefficient and conditional variance, R T R TV in m 1 T T RV m in 1, (4) in 1 V m V s m T RV in m 1, (5) where V in m is the normalized quadrature amplitude fluctuation variable of the input meter wave and is the detection efficiency. In Eqs. 4 and 5 we have assumed that the input signal wave is a coherent state, i.e., V in s 1. It is obvious that for the amplitude-squeezed input meter wave V in m 1 and Fig. 1. Experimental setup. The laser diode LD and collimating lens are cooled in a cryostat. M 1, antireflected mirror; M 2 and M 3, high-reflection mirrors; PBS, polarized beam splitter; PZT, piezoelectric translator; ISO, optical isolator; AM, amplitude modulator; BS, beam splitter with R 46%; PD1, PD2, and PD3, photodiodes with 90% quantum efficiency; SA, spectrum analyzer. perfect detection 1, the quantum measurement fulfilling the QND criteria T 1, V s m 1 can be matched. 20 When we substitute V in m 0.56 corresponding to the amplitude squeezing of 2.5 db and 0.9 into Eqs. 4 and 5, the improved measurements T 1.12 and V s m 0.75 should be obtained with a 50% beam splitter in this scheme. The experimental setup is shown in Fig. 1. Both the LD Spectra Diode Laboratories SDL-5411G1 and collimation lens were cooled down to 77 K inside a liquid nitrogen cryostat to increase emitting efficiency. At the low temperature the threshold current, the emission wavelength, and the overall detection efficiency of the LD were 2.5 ma, 815 nm, and greater than 50%, respectively. The amplitudesqueezed light was generated from the cooled LD with weak optical feedback. Owing to the effect of birefringence on the laser and collimating lens at the low temperature, it is difficult to obtain large squeezing of amplitude noise at a given polarization direction. 15 The phenomenon can be explained by the anticorrelation of the photon-number fluctuation between orthogonally polarized fields. 14 In the total output, including two orthogonal polarizations, the fluctuation of the photon number was partially eliminated owing to the anticorrelation, but for the light polarized at a certain direction, the fluctuation increased owing to the absence of the anticorrelation. Usually in experimental systems the polarizer has to be applied. So to keep the anticorrelation, we added a 4 wave plate at the exit of the cryostat to compensate for the birefringence to restore the linear polarization of the output field of the LD, and at the same time all anticorrelation components were retained. Then the inserted polarizers or wave plates will not influence the anticorrelation in the light beam, so the squeezing will not be reduced. Our experiment demonstrated that the above-mentioned simple method was effective and that an amplitude squeezing of 2.2 db was measured, which was much better than that without the 4 wave plate 1.2 db. The polarizer PBS1 was used to purify further the 5950 APPLIED OPTICS Vol. 40, No. 32 10 November 2001

linear polarization light, and the first 2 wave plate was employed to align to the polarization direction of the optical isolator ISO. To decrease the optical losses, which are quite harmful for squeezing, both sides of the 2 wave plate were coated with antireflection films, and the 2 plate also served as the weak feedback element in suppressing the amplitude noise of the laser. Because the light beams that are reflected from the front and back surfaces of the 2 wave plate are in phase, there is no unexpected effect on the squeezing of the different phase feedback lights from the two surfaces. The feedback was carefully aligned with the PZT stuck on the 2 wave plate to get the maximum squeezing. The second 2 wave plate behind the ISO orientated the polarization direction of light relative to the second polarizer PBS2, which separated the input power into two parts: 1 A small portion 4% transmitted was used as the signal wave, the noise of which was increased to the noise level of a coherent state owing to the large reflective loss, and 2 the large portion reflected was employed as the meter wave required by the quantum measurement that kept almost all squeezing of amplitude fluctuation and input power. The main part of the system is the QND coupler a 50% beam splitter that consists of an input polarizer PBS3, a half-wave plate, and an output polarizer PBS4. The signal and meter input beams have orthogonal polarization, so that the input polarizer superimposes two beams along the input direction of the coupler, the half-wave plate rotates these polarizations by 45, and the second polarizer PBS4 acts as the 50% beam splitter. The evaluation of the characterization of the QND devices requires the measurement of the correlation C 2 X out s X out m between the output signal and meter waves and measurement of the transfer coefficients. To this end, three large-area detector photodiodes PD 1 EG&G FND100, PD2, and PD3 EG&G C30809E are used, and the alternating current ac is amplified by the amplifiers Optical Electronics, Inc. AH0013 and MITEQ, Inc. AU-1310-BNC, and the unit gain bandwidth is 100 MHz and fed into the spectrum analyzer to detect the noise power. The spatial mode matching that was 97% between the input signal and the meter waves at PBS4 was observed by the interference contrast. The phase difference between the input signal and the meter waves was controlled by a serve loop driving the PZT2 to maximize the power of one of the two output waves from PBS4 the other one has minimum effect ; in this case, the input signal and the meter waves are in phase. To measure the noise power spectrum of the input meter wave, we blocked the input signal wave and detected the noise power of the input meter wave with PD2 and PD3. Figure 2 shows the measured noise power spectral density with the LD biased at 34.58 ma, which produces a photon current of 9.06 ma at each detector. Curve a is given by the noise spectrum of a photocurrent difference that agrees well with the shot-noise limit SNL, and curve b is the sum of two photocurrents. The electronic noise Fig. 2. Measured noise power spectra for the squeezed meter source. Curve a, shot-noise limit SNL ; curve b, noise power of the diode laser with a 9.06-mA dc detector current. floor is checked to be a maximum of 13 db. The squeezing of 2.2 db was obtained in the frequency range between 15 and 35 MHz. If the efficiency of the detection system 90% is taken into account, the exact noise squeezing in the meter wave at the beam splitter PBS2 should be 2.5 db. In the experiment the conditional variance is characterized by the quantum correlation between the output signal and meter waves, which is just the optimum noise reduction of differential photocurrent i 2 gi 3 2 between the amplified detectors PD2 and PD3 relative to the shot-noise level of the output signal. 22 Curve 1 in Fig. 3 is the shot-noise power spectrum of the output signal wave that has been checked by the source of red-filtered white light, and it is also calibrated by the wideband infrared LED Hitachi L2656 light, the central wavelength of which is 780 nm. Curve 2 is the lowest noise power spectrum of the different ac photocurrent between two detectors PD2 and PD3, the direct current dc of which is 8.6 ma. The electronic noise level of the amplifier in this condition is 18 db below the SNL at the analysis frequency of 15 MHz and 12 db at 30 Fig. 3. Quantum correlation for the output signal and meter waves. Curve 1 is the SNL of the output signal wave calibrated by infrared white light with the 8.6-mA dc detector current; curve 2 is the difference noise power spectra of the output signal and meter waves. 10 November 2001 Vol. 40, No. 32 APPLIED OPTICS 5951

Fig. 4. Spectral density of the PD1 photocurrent fluctuation. The height of the peak gives the signal-to-noise ratio SNR. MHz. The resolution bandwidth of the spectrum analyzer is 300 khz, and the video bandwidth is 1 khz. In this case 1.0 db of noise reduction is found and from that the conditional variance of 0.8 is obtained. As the result for the squeezing measurement, the conditional variance of 0.8 should be shown across the whole frequency range of the measurement. For the difficult measurements system, the decorrelation at the range of low frequencies is due to the presence of modal partition noise for LD; the other elements for decorrelation may be out of the in-phase between the input signal and meter waves, resulting from the servo loop system or the external noise injection during the measurement. 23 For characterization of the optical tap, the signal wave was modulated by an amplitude modulator at rf 21 MHz. A beam splitter of reflectivity R m 46% in the signal beam extracted a part of the input signal for the measurement of the SNR of the input SNR in s that can be deduced from the directly measured SNR SNR PD1 by the detector PD1, SNR s in SNR PD1 1 R m R m 1, (6) Fig. 5. Noise power spectra of the output signal wave. The SNR of the output signal wave is given by the peak at 21 MHz, which is transferred from the modulation of the input signal wave. Fig. 6. Noise power spectra of the output meter wave. The 21- MHz modulation signal gives the SNR of output meter wave. where 1 90% is the detection efficiency of PD1. Figure 4 shows the noise power spectra of the photocurrent detected by PD1; the SNR of the input signal SNR in s 33.9 db is obtained from the measured date of SNR PD1 and Eq. 6. Figures 5 and 6 are the SNR of the output signal and meter waves directly detected by the noise spectra of the photocurrents at out PD2 and PD3; that is, SNR s 19.3 db and SNR out m 17.0 db. The transfer coefficient T T s T m 1.07 is estimated by the detected fraction of the SNR of the output signal and meter waves to that of the input wave, where T is slightly larger than the quantum limit of 1. In conclusion, we demonstrated for the first time to our knowledge the quantum measurement that met the QND criteria of V s m 1 and T 1 with the amplitude-squeezed LD input meter wave of a beam splitter. In principle the perfect QND can be reached when the amplitude squeezing and detection efficiency are perfect, and the maximum measurements of T 1.12 and V s m 0.75 will be reached when the squeezing of the input meter wave is 2.5 db and the detection efficiency of the system is 0.9. In practice the measured transfer coefficient T 1.07, and the ability of quantum-state preparation V s m 0.8 are obtained. Along with the improvement of LD squeezing and detection efficiency, the quality of measurement must be improved. We believe that with the compact and reliable all-solid-state system, the presented scheme might be useful for practical application. This research was supported by the National Natural Science Foundation C 69837010, the Overseas Youth Scholar Collabration Foundation 69928504, and the Shanxi Province Young Science Foundation 20001016. References 1. V. B. Braginsky, Y. I. Vorontsov, and K. S. Thorne, Quantum nondemolition mesurements, Science 209, 547 556 1980. 2. M. D. Levenson, R. M. Shelby, M. Reid, and D. F. Wall, Quantum nondemolition detection of optical quadrature amplitudes, Phys. Rev. Lett. 57, 2473 2476 1986. 3. A. La Porta, R. E. Slusger, and B. Yurke, Back-action evading measurement of an optical field parametric down conversion, Phys. Rev. Lett. 12, 28 31 1989. 5952 APPLIED OPTICS Vol. 40, No. 32 10 November 2001

4. S. F. Pereira, Z. Y. Ou, and H. J. Kimble, Back-action evading measurements for quantum nondemolition detection and quantum optical tapping, Phys. Rev. Lett. 72, 214 217 1994. 5. E. Goobar, A. Karlsson, and G. Bjork, Experimental realization of a semiconductor photon number amplifier and a quantum optical tap, Phys. Rev. Lett. 71, 2002 2005 1993. 6. J. F. Roch, J. P. Poizat, and P. Grangier, Sub-shot noise manipulation of light using semiconductor emitters and receivers, Phys. Rev. Lett. 71, 2006 2009 1993. 7. A. B. Matsko and S. P. Vyatchanin, A ponderomotive scheme for QND measurement of quadrature component, Appl. Phys. B 64, 167 171 1997. 8. R. Bruckmeier, K. Schneider, S. Schiller, and J. Mlynek, Quantum nondemolition measurements improved by a squeezed meter input, Phys. Rev. Lett. 78, 1243 1246 1997. 9. R. Bruckmeier, K. Schneider, H. Hansen, M. Schalke, S. Schiller, and J. Mlynek, Continuous-wave quantum nondemolition measurements with vacuum and nonclassical meter input, Appl. Phys. B 64, 203 212 1997. 10. J. H. Shapiro, Optical waveguide tap with infinitesimal insertion loss, Opt. Lett. 5, 351 353 1980. 11. M. J. Holland, M. J. Collett, D. F. Walls, and M. D. Levenson, Nonideal quantum nondemolition measurements, Phy. Rev. A 42, 2995 3005 1990. 12. R. Bruckmeier, H. Hansen, S. Schiller, and J. Mlynek, Realization of a paradigm for quantum measurements: the squeezed light beam splitter, Phys. Rev. Lett. 79, 43 46 1997. 13. H. Wang, Y. Zhang, Q. Pan, H. Su, A. Porzio, C. Xie, and K. Peng, Experimental realization of a quantum measurement for intensity difference fluctuation using a beam splitter, Phys. Rev. Lett. 82, 1414 1417 1999. 14. D. C. Kilper, D. G. Steel, R. Craig, and D. R. Scifres, Polarization-dependent noise in photon-number squeezed light generated by quantum-well lasers, Opt. Lett. 21, 1283 1285 1996. 15. H. Wang, M. J. Freeman, and D. G. Steel, Squeezing light from injection-locked quantum well lasers, Phys. Rev. Lett. 71, 3951 3954 1993. 16. Y. Q. Li, P. Lynam, M. Xiao, and P. J. Edwards, Sub-shotnoise laser Doppler anemometry with amplitude-squeezed light, Phy. Rev. Lett. 78, 3105 3108 1997. 17. D. C. Kilper, A. C. Schaefer, J. Erland, and D. G. Steel, Coherent nonlinear optical spectroscopy using photon-number squeezed light, Phys. Rev. A 54, R1785 R1788 1996. 18. S. Kasapi, S. Lathi, and Y. Yamamoto, Amplitude-squeezed, frequency-modulated, tunable, diode-laser-based source for sub-shot-noise FM spectroscopy, Opt. Lett. 22, 478 480 1997. 19. F. Marin, A. Bramati, V. Jost, and E. Giacobino, Demonstration of high sensitivity spectroscopy with squeezed semiconductor lasers, Opt. Commun. 140, 146 157 1997. 20. J. A. Levenson, I. Abram, T. Rivera, P. Fayolle, J. C. Garreau, and P. Grangier, Quantum optical cloning amplifier, Phys. Rev. Lett. 70, 267 269 1993. 21. J. Ph. Poizat and P. Grangier, Experimental realization of a quantum optical tap, Phys. Rev. Lett. 70, 271 274 1993. 22. J. P. Poizat, J. F. Roch, and P. Grangier, Characterization of quantum non-demolition measurements in optics, Ann. Phys. Fr. Paris 19, 265 297 1994. 23. Y. Q. Li, P. J. Edwards, P. Lynam, and W. N. Cheung, Quantum-correlated light from transverse junction stripe laser diodes, Int. J. Optoelectron. 10, 417 421 1995. 10 November 2001 Vol. 40, No. 32 APPLIED OPTICS 5953