NG-PON2 Optical Components Update. Hal Roberts System Architect

Similar documents
50Gb/s technical feasibility analysis. Dekun Liu, Huawei Stanley Shuai, Source Sep, 2017

25G TDM PON overview. Ed Harstead, member Fixed Networks CTO Dora van Veen, Vincent Houtsma, and Peter Vetter, Bell Labs

Consideration about wavelength allocation in O-band

High Speed TWDM PON - A Review

Marek Hajduczenia, ZTE Corp.

ECEN689: Special Topics in Optical Interconnects Circuits and Systems Spring 2016

SOA pre-amplified upstream signal power in 100G EPON

Life Science Journal 2013;10(4)

Putting the D back into DWDM Full-band Multi-wavelength Systems Mani Ramachandran CEO / CTO InnoTrans Communications

Optimization of uncooled RSOA parameters in WDM reflective PONs based on self-coherent or direct detection OLT receivers

Polarization Optimized PMD Source Applications

Experimental Demonstration of 56Gbps NRZ for 400GbE 2km and 10km PMD Using 100GbE Tx & Rx with Rx EQ

Downstream Transmission in a WDM-PON System Using a Multiwavelength SOA-Based Fiber Ring Laser Source

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

Development of Small Optical Transceiver for 10G-EPON

Annex 91A Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

Chapter 1 Introduction

Photonic Integrated Circuits for 400 Gigabit and 1 Terabit Coherent Transport

Four-wave mixing in O-band for 100G EPON John Johnson

Advances in Widely Tunable Lasers Richard Schatz Laboratory of Photonics Royal Institute of Technology

Istituto Superiore Mario Boella, via P. C. Boggio 61, Torino - Italy

Minutes 802.3av 10G EPON Task Force Plenary Meeting Dallas, TX

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

GETX-5351S-X3CDA Asymmetricl 10G EPON OLT Transceiver

ITU-T. G Amendment 2 (08/2017) 40-Gigabit-capable passive optical networks 2 (NG-PON2): Physical media dependent (PMD) layer specification

Research on Optical Access Network

Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

Enhanced 10 Gb/s operations of directly modulated reflective semiconductor optical amplifiers without electronic equalization

Super-PON. Scale Fully Passive Optical Access Networks to Longer Reaches and to a Significantly Higher Number of Subscribers

Product Specification Sheet

EPON-OLT-SFP-20. Features. Applications. Standard. 1.25G OLT 20km transmission

Technical Feasibility of 4x25 Gb/s PMD for 40km at 1310nm using SOAs

SOA + PIN-PD receiver performance

TR-423 PON PMD Layer Conformance Test Plan

Finisar Contributors. Dave Adams Alan Chen Dingbo Chen Shiyun Lin Daniel Mahgerefteh Yasuhiro Matsui Thelinh Nguyen. 19 September

High-Speed Directly Modulated Lasers

Physical Media Dependent Prototype for 10-Gigabit-Capable PON OLT

Colorless Amplified WDM-PON Employing Broadband Light Source Seeded Optical Sources and Channel-by-Channel Dispersion Compensators for >100 km Reach

Trends in Optical Transceivers:

TS-GP2512-OLT-C+ GPON OLT Class C+ SFP Transceiver FEATURES

Optical Delay Line Application Note

100G EPON Downstream wavelength plan

Mahendra Kumar1 Navneet Agrawal2

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

Optical Networks emerging technologies and architectures

SO-SFP-16GFC-ER-Dxxxx

Research on Optical Access Network. Assoc. Prof. Dr. Duang-rudee Worasucheep Electrical Engineering Department Chulalongkorn University

Extending 100Gbit/s Ethernet. Ariën Vijn

SCTE. San Diego Chapter March 19, 2014

Effects of Upstream Incoherent Crosstalk Caused by ASE Noise from Tx-Disabled ONUs in XG-PONs and TWDM-PONs

Optical Digital Transmission Systems. Xavier Fernando ADROIT Lab Ryerson University

40GBd QSFP+ LR4 Optical Transceiver

A comment on Table 88-7 and 88-8 in Draft 1.0

photonique et laser (COPL) Department of Electrical and Computer Engineering, Université Laval

SOA-PIN performance. Rene Bonk, Dora van Veen, Vincent Houtsma, Bell Labs Ed Harstead, member Fixed Networks CTO. January 2017

Optical Fiber Technology

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

XGSPON ONU Optical Module

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

Low Power DSP and Photonic Integration in Optical Networks. Atul Srivastava CTO, NTT Electronics - America. Market Focus ECOC 2014

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG

Coexistence of 10G-PON and GPON Reach Extension to 50-Km with Entirely Passive Fiber Plant

A HIGH SPEED WDM PON FOR DOWNSTREAM DPSK ASK SIGNALS AND UPSTREAM OOK SIGNAL WITH BROADCAST CAPABILTY

Optical Local Area Networking

HOLT Transceiver for EPON (HOLT-11C214L22) 2X10 SFF, Pigtailed with SC, +3.3V, 1.25Gbps, 20km 1490nmTX/1310RX, DFB-LD/APD, 0~70. Feature.

An upstream reach-extender for 10Gb/s PON applications based on an optimized semiconductor amplifier cascade

P2MP PMD Baseline. Prepared by Frank Effenberger Quantum Bridge Communications

XLT35-0D6C. 10GEPON OLT PR30 XFP Transceiver Rev. A0, May Features. Application. Standard

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

Optical phase-locked loop for coherent transmission over 500 km using heterodyne detection with fiber lasers

4x100GE through 2 and 10km SMF Using DMT and 1.3mm LAN-WDM EMLs. Winston Way, Trevor Chan, NeoPhotonics, USA

GPON OLT SFP Class C+

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

Characterization of uncooled RSOA for upstream transmission in WDM reflective PONs

Implementation of Future Generation Agile Gigabits Passive Optical Network

TRANSMISSION OF NG-PON FOR LONG HAUL NETWORKS USING HYBRID AMPLIFIER

80 GBPS DOWNSTREAM TRANSMISSION USING DQPSK AND 40 GBPS UPSTREAM TRANSMISSION USING IRZ/OOK MODULATION IN BIDIRECTIONAL WDM-PON

Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing

10G PON Series Preliminary

Assessment of improvement of extension of reach of 10 Gbps PONs by using APDs

A WDM passive optical network enabling multicasting with color-free ONUs

E-PON OLT PX-30 Transceiver

Channel Equalization and Phase Noise Compensation Free DAPSK-OFDM Transmission for Coherent PON System

Microwave and Optical Technology Letters. Minhui Yan, Qing-Yang Xu 1, Chih-Hung Chen, Wei-Ping Huang, and Xiaobin Hong

ITU-T G (03/2008) Gigabit-capable passive optical networks (GPON): Reach extension

Study of Orthogonal Modulation Schemes for Passive. Optical Access Networks.

Interoperability of CWDM-routed reflective PONs. This chapter presents a complete multi-pon access network infrastructure by means of

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Innovations in Photonic Integration Platforms

All-VCSEL based digital coherent detection link for multi Gbit/s WDM passive optical networks

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

PERFORMANCE EVALUATION OF GB/S BIDIRECTIONAL DWDM PASSIVE OPTICAL NETWORK BASED ON CYCLIC AWG

OPTICAL NETWORKS. Building Blocks. A. Gençata İTÜ, Dept. Computer Engineering 2005

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

Proposal for 400GE Optical PMDs for SMF Objectives based on 4 x 100G DMT David Lewis, Sacha Corbeil, Beck Mason

Emerging Highly Compact Amplification Solutions for Coherent Transmission

The Development of the 1060 nm 28 Gb/s VCSEL and the Characteristics of the Multi-mode Fiber Link

VCSEL Based 10 Gigabit Serial Solutions

Transcription:

NG-PON2 Optical Components Update Hal Roberts System Architect

Agenda NG-PON2 Optical Challenges ONU Optics Challenges OLT Optics Challenges NG-PON2 Solutions for Optics ONU Optics OLT Optics Discrete Optics Approaches Photonic Integrated Optics Approaches Discrete Optics Approaches Photonic Integrated Optics Approaches

ONU Optical Challenges

High ONU Transmit Power and Dispersion To avoid optical amplifiers, higher Tx power is needed from the ONU +4dBm to +9dBm Transmit Power required (for Type A system) Relatively easy to achieve with DMLs (Direct Modulated Laser), but they have a large dispersion penalty for 10Gbps Upstream rates EMLs (Externally Modulated Lasers) have a low dispersion penalty but cannot achieve +4dBm minimum power

Spectral Excursion Maximum Spectral Excursion in Burst Mode Operation ONU wavelength must be contained in a 40 GHz window Unlike point to point optics, PON upstream operates in burst mode ONU laser must go from completely off to on in 128 ns Inrush of current causes 25 GHz to 40 GHz spectral shift Finisar: Yasuhiro Matsui Short Term Spectral Excursion (STSE) Mitigation Sept 8 th, 2014

ONU Tuning Speed Switching Speeds for Wavelength Tuning TWDM-PON ONU Optics must be able to tune across a minimum of 4 wavelengths Three Classes of Switching Times Class 1: < 10 μs Class 2: 10 μs to 25 ms Class 3: 25 ms to 1 sec Service Restoration through Wavelength Mobility Must be < 50ms Therefore Class 2 wavelength switching is needed

ONU Optical Echoes Reflections in the fiber ODN can cause an ONU burst echo to land on another ONU burst If wavelengths coincide interference occurs Current ONU Reflectance 6dB Needs to be better to avoid problem

OLT Optical Challenges

NG-PON2 Optical Budgets Most Popular Budget Classes Class N1 20km + 64-way split Class N2 or E1 20km + 128-way split OLT Receiver Sensitivity is most challenging

OLT Receiver Sensitivity APDs are most common and popular OLT receiver NG-PON2 adds loss of the Wavelength Multiplexer Additional power penalties for Out of Channel and Out of Band noise and Echoes Consequence: Typical APD receivers cannot meet any of the optical budget requirements, including the smallest one, N1

OLT Transmit Power EMLs are typically used at OLT due to DML Dispersion Penalty Due to penalties and WM losses EMLs cannot meet required transmit power for any of the budgets, N1, N2, E1 or E2

ONU Solutions for Optics Challenges

ONU Discrete Optics Solutions EML + SOA Transmit Power Solution EML is ideal laser from optical dispersion standpoint but power is too low Solution: Follow EML with SOA (Semiconductor Optical Amplifier) Can be two discrete parts or two components on one chip Spectral Excursion Solution The SOA may also be used as an optical shutter Shutter opens when laser is stable Disadvantages: High power consumption and high cost

ONU Discrete Optics Solutions DML with reduced ER DMLs normally have too much chirp for use in 10Gbps TWDM-PON optics over 20km With 6dB ER, BER < 10-3 not possible for needed sensitivity Power penalty = too high Reducing DML Extinction Ratio (ER) reduces chirp Transmit power of DML is increased according to new Tx vs ER table proposed for G.989.2 amendment 2 to compensate for reduced ER

Extinction ratio ONU Discrete Optics Solutions DML with reduced ER Calix and other contributions determined worst case degradation with decreased ER (extinction ratio) Goal: No performance degradation at the OLT receiver Allows use of directly modulated lasers (DML) Laser must compensate with higher minimum transmit power Targeted for G.989.2 amd 2 ER 1 ER 2 ER 3 ER 4,5 P 1 Mean launch optical power P 2 P 3 P 4 P 5

ONU Discrete Optics Solution 10G Down, 2.5G Up Consider 10G/2.5G Asymmetrical Line Rate and Class 3 Tuning for Residential Services Dispersion issues with DMLs Mitigated Higher power of DML can be used for Type A ONUs No need to reduce ER and increase Tx power Slower tuning allows use of simple conventional temperature control Spectral excursion less problematic Result Viable TWDM-PON vendors triple or quadruple Costs significantly reduced Can coexist with 10G/10G Business ONUs via dual burst rate OLT

ONU Discrete Optics Solution Consider Fixed Wavelength? Fixed wavelength does not directly address the challenges except obviously the tuning time challenge Fixing the TWDM-PON ONU wavelengths does lead to secondary improvements Laser no longer heated to high temperatures to tune to all 4 channels, EMLs can now achieve Type A transmit power levels Receiver becomes identical in simplicity to other 10G receiver technologies and costs (like XGS-PON) Disadvantage: Wavelength mobility advantages such as software upgrade and wavelength protection eliminated Need to stock Wavelength SKUs

Discrete Optics Solution for Tuning DBR (Distributed Bragg Reflector) Laser DBR Laser can tune in nanoseconds Spectral Excursion can be reduced to 5GHz DBR is also capable of meeting Class 2 and even Class 1 Tuning Times Disadvantage: Currently very expensive Finisar: Yasuhiro Matsui Short Term Spectral Excursion (STSE) Mitigation Sept 8 th, 2014

Discrete Optics Solution for Tuning Low Thermal Mass Thermal Tuning is commonly used Large thermal mass and low impedance = Slow tuning times Solution: Reduce Thermal Mass Increase Thermal Impedance Air-Gap Suspended Waveguide Result: < 0.3 milliseconds tuning Note: Same principal of low thermal mass and high thermal impedance works for receiver filter tuning Narrow Linewidth Tunable Semiconductor Laser, Yasuhiro Matsui et al, IPRM 2016 Invited Paper

NG-PON2 Optical Solution ONU Optical Echoes Reducing Reflection at ONU Calculations show that if reflections are < -32dB, the problem of echoes is mitigated Calix survey shows vendors are able to achieve < -32dB reflectance Cost increase zero or minimal June - Geneva Plenary G.989.2 amendment 2

Photonic Integrated Circuits Tunable PICs Solution Multiple optical components can be integrated onto one substrate Additional components solve technical challenges SOA to increase Tx power and act as shutter External tunable Tx filter improves out of band noise External modulator reduces dispersion penalty SOA at Rx to increase sensitivity Fast thermal tuning with low thermal mass = Class 2 switching speed Cost stays low due to integration Disadvantage: High upfront costs Time to develop process

Photonic Integrated Circuits Fixed PICs Solution Concept: Modified 4 lane 25Gbps = 100Gbps Ethernet Transceiver Borrow from 100 Gbps PIC technology parallel transmitters and receivers Four lasers on one substrate are similar in cost to one laser Laser Wavelength Switching in few nanoseconds, just turn on desired laser Four lasers on one substrate are similar in cost to one laser Receiver Wavelength Switching instantaneous External modulator reduces dispersion penalty SOA at Tx to boost power SOA at Rx to increase sensitivity Cost stays low due to integration Disadvantage: High development costs and long lead time for process development *Same technique can be used for 20-40Gbps Bonded ONU

OLT Solutions for Optics Challenges

Sensitivity at BER = 1e-3 OLT Solution Receiver Sensitivity Approaches State-of-Art APDs and TIAs (Trans- Impedance Amplifier) for N1 Class Closed 1dB gap for N1 link budget For Link Budgets N2 E2 SOA in receiver, can achieve -32 to -34dBm Quasi-Coherent Receiver, can achieve -34dBm Also allows use of Type B ONUs OK for EMLs -40-15 -20-25 -30-35 Sensitivity with ASE, SOA, WM and APD 2 4 6 8 10 No ASE ASE = 32 db ASE = 30 db ASE = 28 db ASE = 26 db ASE = 24 db ER (db)

OLT Optical Solution Transmit Power EMLs are typically used at OLT due to DML Dispersion Penalty Due to penalties and WM losses EMLs cannot meet required transmit power for any of the budgets, N1, N2, E1 or E2 Solution: SOA in OLT Transmitter Can achieve N1, N2 and possibly E1

Extended Budget Solution: Active Wavelength Multiplexer Allows relaxed requirements on ONUs and OLTs Boost upstream and downstream power by using optical amplifiers in the Wavelength Multiplexer Active WM Allows lower power Type B ONU optics, reducing cost Disadvantages Additional active device to monitor and manage Requires additional reliable power supply Requires increased rack space Adds cost (may be offset by lower ONU cost) Optical Amplifier failure brings down entire ODN (can be managed with redundant amplifiers and optical switch, but adds more cost)

Conclusions NG-PON2 is a very powerful and flexible new PON standard With some of the power and flexibility came optical challenges to be overcome But optical component vendors have brought forth a wide variety of approaches to meet the challenges This bodes well for meeting the challenges with possibly multiple solutions High sensitivity OLT allows Type B ONU EML for 10G/10G Use of 10G/2.5G ONU allows DML for lower cost and more vendors PICs have promise for long term Will one solution win over time? stay tuned!