INSTALLATION MANUAL for KLINGER gaskets

Similar documents
Gasket Installation Procedures. Assuring! joint integrity and! maximum safety

NTTC Tank Truck Week Awareness Gaskets/Fasteners/Flanges

Figure 11 Flange Adapter and Back-Up Ring

Fasteners. Fastener. Chapter 18

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

HEATEC TEC-NOTE Publication No

Durapipe ABS Jointing Guide

SYGEF Standard SYGEF Plus PVDF Flanges

Spiderbeam Balun Construction Guide

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

OPERATOR S MANUAL Model 77E Pneumatic Cable Stripper

USER MANUAL Nord-Lock X-series washers

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

Practical Bolting and Gasketing for the Non Standard-Flanged Joint

INSTALLATION INSTRUCTIONS ROPE ASSEMBLIES FATZER AG WITH HYEND SOCKETS FOR FROM. Kai-J. Thiem (THK) Martin Bechtold (BEM)

C-15 Truck Engine 9NZ00001-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/07/2008 Date Updated -22/07/2008

Procedure for Wrench Calibration and Snug Tightening

Storage Cabinets 9000 Series Assembly Instructions

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

Big Block Installation Manual For Systems without A/C

Fluid Sealing Association

CTTR Tire Rack Required tools

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

Tightening of Structural Joints

w w w. h d o n l i n e s h o p. d e AUTOMATIC COMPRESSION RELEASE TOOL GENERAL INSTALLATION -J04654 REV Kit Number Models

Electric Skein Winder

INSTALLATION INSTRUCTIONS

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

Grizzly Drill Press SOP

Threaded Fasteners 2. Shigley s Mechanical Engineering Design

OWNERS MANUAL. Model No LB. POLY PRO SPIKER/SPREADER. CAUTION: Read Rules for Safe Operation and Instructions Carefully

Assembly, Use and Care Instructions

INSTALLATION INSTRUCTIONS. PLASMA TV WALL MOUNT TILT Universal (RGTU-210) WARNINGS WARNING

DASHLEY COLLECTION GAZEBO

Fisher 667 Diaphragm Actuators Size 80 and 100

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

MSP-DCCPGSU Large Screen Static Display Mount

28" Adjustable Solar Tilt Mount ADJ-28. Owner's Manual. Please read this manual BEFORE installing your solar tilt mount

MSP-DCCPGTU Large Screen Tilt Display Mount

UNIVERSITY OF THESSALY

QUATRA LUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Installation Instructions Kit, Base Rail Bracket Part # 31413

INSTALLATION INSTRUCTIONS

LB. POLY PRO DROP SPREADER

Instructions and Parts List DR-12N Martin House

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Installation Guide. TV-Wall Mount Bracket VM-SL10D Article: 50505

Joint relaxation behaviour of gasketed bolted flanged pipe joint during assembly

Evaluation of In-Pavement Light Fixture Designs and Performance

MS25 OPERATION MANUAL

General Four-Way Operation, Maintenance & Service Manual

LX1 Maintenance Manual for Model LX1B. Table of Contents 1. GENERAL DISASSEMBLY, ASSEMBLY AND ADJUSTMENT COMPONENTS...

MODEL G4017 G4020 ARBOR PRESS INSTRUCTIONS

INSTRUCTIONS INSTRUCCIONES CONSIGNES

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

MAINTENANCE GUIDE ULTRAEDGE LHD LIP SHROUD SYSTEM INSTALLATION, MAINTENANCE AND REMOVAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Swivel Hoist Ring Page 142

INSTALLATION INSTRUCTIONS Product No. MULTI-FIT PICK-UP

Instruction Sheet RADIO FREQUENCY SYSTEMS. Install. Instr. for Microwave Parabolic Antennas 2.4 m (8 ft) No Rev.

Installation & Owner's Manual

TWL 1500 TORQUE WRENCH LOADER

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" SLIDING COMPOUND MITER SAW

Assembly Instructions and Owner s Manual Flex TechBridge

Product Guide Specification

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

DRIVE COMPONENTS REMOVAL. 9. FXCW/C: see Figure Remove bolt (9), sprocket retainer (8), and thrust washer (7). NOTE PRIMARY DRIVE LOCKING TOOL

Components made of special materials. Floor Elements for Profile St Profile KH. Fastening Elements for Profile KH

Pickup Box Utility Rack Package Installation (Instruction ID: )

AN, MS, NAS Bolts. AN3 20 bolts are identified by a multi-part code:

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

Instruction Manual for installing

Instruction Manual for installing

TAILGATE SPREADER MATERIAL SAVER SYSTEM INSTALLATION & OPERATION MANUAL (TGS 300, TGS 600, & TGS 1100) TGS11328

RBP-1215B-RX DODGE RAM QUAD CAB RX3

INSTALLATION INSTRUCTIONS

Assembly Instructions. Important!

Guardrail T40 4MS2 BP for Bridge Parapet

USER MANUAL MODEL MZ-100 BOLT TENSION CALIBRATOR

Installation Instructions Kit, Base Rail Bracket Part # 31413

What is a fastener? A device to locate or hold parts

INSTALLATION INSTRUCTIONS CONTOURED LIGHT BAR APPLICATION: CHEVY EQUINOX/ GMC TERRAIN PART NUMBERS: ,

Installation Guide Philips MP40/50/60/70 Installation Kit for Penlon Anesthesia Machine

Sales & Service. JFK - Just For Kids. sasportonline.com. 135 Forestview Road 7879 Will Rogers Blvd.

3 wide x 3 deep Video Wall Display Installation Guide

T R I - S TA N D C H A I N V I S E

Thread protection accessories are installed at the MODIX production factory and delivered with couplers.

High Strength Weathering Steel Structural Bolting Assemblies PC 8.8 Hex. Cooper & Turner Ltd. Worldclass products for a.

Pow-R-Feed Systems Service Manual

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

INSTALLATION INSTRUCTIONS

INSTALLATION & OWNER S MANUAL

Installation Guide Philips MP80/90 Installation Kit for Penlon Anesthesia Machine

9/8/98 AC B CAUTION THE FOLLOWING TORQUE VALUES ARE DERIVED FROM OIL FREE CADMIUM PLATED THREADS.

AFB (AIR FAN BEARING) INSTALLATION GUIDE

MECH-100: Fundamentals of Precision Maintenance

Transcription:

INSTALLATION MANUAL for KLINGER gaskets

INSTALLATION TIPS FOR KLINGER GASKETS SUITABILITY Check on chemical resistance STORAGE Check on storage conditions PT-DIAGRAMS Review the pt-diagrams

INSTALLATION INSTRUCTIONS FOR KLINGER GASKETS 1. GASKET 2. STORAGE 3. HANDLING DIMENSIONS 1.1 CORRECT SIZE The gasket has to have the correct size. 1.2 BOLT HOLES Cut the bolt holes just a bit larger than the bolts to simplify the centralization of the gasket. 1.3 INNER DIAMETER The inner diameter of the gasket should not be smaller than the inner diameter of the flange. CUT THE BOLT HOLES LARGER THAN THE BOLTS 2.1 IDEAL STORAGE CONDITIONS The gasket should be stored horizontal to avoid tensions and permanent warpage. Ideal storage conditions are: temperature < 25 C air humidity 50-60% darkened storage room Store the gasket in a clean condition (ideally in a plastic bag). 3.1 PROTECT THE GASKET All types of gaskets (metallic gaskets, PTFE gaskets, fibre reinforced gaskets etc.) should be handled with the same care and attention. Avoid carrying small gaskets in a pocket to protect the gasket from damage. Carry ready cutted gaskets carefully, ideally in some form of protective cover. 3.2 PROTECT THE SURFACE Do not bend the gasket and do not damage the surface. 3.3 TAKE CARE Metal reinforced gaskets could cause injuries.

4. BOLTS / NUTS / WASHERS 5. GASKET INSTALLATION 4.1 BOLT PROPERTIES Pay attention that all bolts which are designed for the flange are installed. Check if the used bolts are suitable for the given operating temperatures. Tighten the bolts crosswise with the correct torque (calculation with KLINGER expert). Ensure that there is no corrosion on the bolts because this can effect the function of the bolt. Never re-use bolts. 4.2 NUT PROPERTIES Use a nut which has a specified proof load 20% higher than the ultimate strength of the fastener. Use standard threads, rather than fine. Use the correct lubricant. 4.3 WASHERS Use the same material for the washers and the nuts. Use washers to: bridge slotted or oversized holes even interface forces between joint components reduce problems of fatigue by spreading the load placed by the fastener on the joint. 5.1 THE TOOLS At first make sure that the following tools are available and in good condition: the correct gasket chosen for the specific application a calibrated torque wrench a wire brush lubricants for the bolts 5.2 CLEANING OF ALL FLANGE SURFACES Make sure that the flange surfaces are clean. Check the bolts and the flange surface if they are technically ok and free from any serious defects. Always brush in the direction of the grooves. To avoid damage on the flange surface please use a brass drift. 5.4 IMPORTANT FOR THE GASKET Insert the gasket carefully between the flanges. The gasket has to be centralized in the flange. Ensure that the gasket is installed in a dry state. It is important that the gasket is not pinched or otherwise damaged when bringing the flanges together. 5.5 LUBRICATION OF BOLTS Apply lubricant to the bolt and the nut threads as well as to the face of the nut to reduce friction when tightening. Pay attention that the lubricant does not contaminate the gasket or the flange surfaces. The recommended service temperature of the lubricant has to be within the process service temperature limits. 5.3 FLANGE CONDITIONS Make sure that the flanges are parallel and report all irregularities. MAKE SURE THE GASKET IS UNDAMAGED WHEN BRINGING THE FLANGES TOGETHER

5.7 RE-TIGHTENING 5.8 RE-USE OF GASKETS 30% 60% If retightening is considered necessary, this should only be done at ambient temperatures before or during the first start-up. Never retighten compressed fibre gaskets at higher operating temperatures and longer operating times. For safety reasons never re-use a gasket. The cost of a gasket is minimal compared with the costs which are related to a down time of the plant. 100% 5.6 BOLT TIGHTENING The required torque value can be calculated with KLINGER expert. Make at least 4 stages to the required torque as follows: finger tighten bolts use 30% of the required torque use 60% of the required torque use 100% of the required torque Close the torquing with one final pass in a clockwise sequence. THE GASKET HAS TO HAVE THE CORRECT SIZE

Rich. Klinger Dichtungstechnik GmbH & Co KG Am Kanal 8-10» A-2352 Gumpoldskirchen T +43 2252 62599 137» F +43 2252 62599 296 marketing@klinger.co.at www.klinger.co.at