IP67 Ⅱ Ⅱ
SPECIFICATION MODEL NPF-60D-12 NPF-60D-1 NPF-60D-20 NPF-60D-24 NPF-60D-30 NPF-60D-36 NPF-60D-42 NPF-60D-48 NPF-60D-4 DC VOLTAGE CONSTANT CURRENT REGION RATED CURRENT RATED POWER 12V 7.2 ~ 12V A 1V 9 ~ 1V 4A 20V 12 ~ 20V 3A 24V 14.4 ~ 24V 2.A 30V 18 ~ 30V 2A 36V 21.6 ~ 36V 1.67A 60.12W 42V 2.2 ~ 42V 1.43A 60.06W 48V 28.8 ~ 48V 1.2A 4V 32.4 ~ 4V 1.12A 60.48W RIPPLE & NOISE (max.) Note.2 10mVp-p 10mVp-p 10mVp-p 10mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 30mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION LOAD REGULATION ±1.% ±1.0% ±1.0% SETUP, RISE TIME Note.4 00ms, 80ms at 9% load 11VAC / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE 16ms/230VAC 90 ~ 30VAC 47 ~ 63Hz 16ms/11VAC at full load 127 ~ 431VDC POWER FACTOR (Typ.) PF>0.97/11VAC, PF>0.9/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) INPUT TOTAL HARMONIC DISTORTION THD< 20% when output loading 60% at 11VAC/230VAC input and output loading 7% at 277VAC input EFFICIENCY (Typ.) 86% 87% 88% 89% AC CURRENT (Typ.) 0.8A / 11VAC 0.4A / 230VAC 0.32A / 277VAC INRUSH CURRENT(Typ.) MAX. No. of PSUs on 16A CIRCUIT BREAKER COLD START 0A(twidth=270 μs measured at 0% Ipeak) at 230VAC 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.2mA / 277VAC SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed 9 ~ 108% OVER CURRENT Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 1 ~ 17V 17. ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 4V 4 ~ 60V 9 ~ 66V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -40 ~ +70 (Refer to "Derating Curve") 20 ~ 9% RH non-condensing -40 ~ +80, 10 ~ 9% RH ± 0.03%/ (0 ~ 0 ) 10 ~ 00Hz, G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL870(type HL ), CSA C22.2 No. 20.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN6033-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.7KVAC EMC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 00VDC / 2 / 70% RH EMC EMISSION Compliance to EN01, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,,6,8,11; EN6147, light industry level(surge 2KV), criteria A OTHERS NOTE MTBF 314.0K hrs min. MIL-HDBK-217F (2 ) DIMENSION 10*3*3mm (L*W*H) PACKING 0.49Kg;30pcs/1.7Kg/1.0CUFT
Block Diagram PFC fosc : 0~120KHz PWM fosc : 60~130KHz I/P EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.L.P. +V -V DIM+ DIM- O.T.P. O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Static Characteristics 100 100 90 80 60 230VAC Input only 80 70 LOAD (%) 0 40 20 LOAD (%) 60 0 40-40 -2-10 0 1 30 0 60 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 90 100 12 13 14 1 16 17 180 200 230 30 INPUT VOLTAGE (V) 60Hz Power Factor Characteristic 1.0 Constant Current Mode PF 0.9 0.8 0.7 0.6 0. 0.4 0.3 277V 230V 11V 10% 20% 30% 40% 0% 60% 70% 100% LOAD ()
EFFICIENCY vs LOAD (48V Model) NPF-60D series possess superior working efficiency that up to can be reached in field applications. 92% EFFICIENCY (%) 88% 86% 84% 82% 277V 230V 11V 78% 10% 20% 30% 40% 0% 60% 70% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. 100 Vo(%) Constant Current area In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. 60 (min.) Hiccup Protection 0 100 Io (%) Typical LED power supply I-V curve
DIMMING OPERATION AC/L(Brown) AC/N(Blue) NPF-60D +V(Red) -V(Black) DIM+(Blue) DIM-(White) Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or 0 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-. Please DO NOT connect "DIM-" to "-V". Reference resistance value for output current adjustment (Typical) Single driver Resistance value Multiple drivers (N=driver quantity for synchronized dimming operation) Percentage of rated current Short 10KΩ 20KΩ 30KΩ 40KΩ 0KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ OPEN Short 10K Ω/N 20K Ω/N 30K Ω/N 40K Ω/N 0K Ω/N 60K Ω/N 70K Ω/N 80K Ω/N 90K Ω/N 100K Ω/N ----- 0% 10% 20% 30% 40% 0% 60% 70% 100% 9%~108% 0 ~ 10V dimming function for output current adjustment (Typical) Dimming value 0V 1V 2V 3V 4V V 6V 7V 8V 9V 10V Percentage of rated current 0% 10% 20% 30% 40% 0% 60% 70% 100% 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value Percentage of rated current 0% 0% 10% 10% 20% 20% 30% 30% 40% 40% 0% 0% 60% 60% 70% 70% 100% 100% OPEN 9%~108% OPEN 9%~108% Dimming Characteristic Output Current Percentage of rated current(%) 100% 70% 60% 0% 40% 30% 20% 9%~108% when DIM+/DIM- are open circuit. 10% Note 0% 0V 1V 2V 3V 4V V 6V 7V 8V 9V 10V 0~10V 0% 10% 20% 30% 40% 0% 60% 70% 100% Short 10K/N 20K/N 30K/N 40K/N 0K/N 60K/N 70K/N 80K/N 90K/N 100K/N Duty cycle of 10V PWM (frequency range = 100~3KHz) Short~100K Ω/N resistance (N=driver quantity for synchronized Dimming input dimming operation ) Note : 1. Min. dimming level is about 6% 2. The output current is not defined when 0%< Iout<6% 3. The output current could drop down to 0% when dimming input is about 0KΩor 0Vdc, or 10V PWM signal with 0% duty cycle
Mechanical Specification Case No.: NPF-60A Unit:mm 10 300±20 AC/L(Brown) AC/N(Blue) SJTW 18AWG 2C 3 T case 300±20 UL2464 18AWG 2C(+V,-V) UL2464 22AWG 2C(DIM+,DIM-) +V(Red) -V(Black) DIM+(Blue) DIM-(White) T case: Max. Case Temperature 3 ψ4. 13 3 3 Recommend Mounting Direction Installation Manual Please refer to : http://www.meanwell.com/webnet/search/installationsearch.html