CE EMC CERTIFICATION

Similar documents
CE EMC Test Certification

CE TEST CERTIFICATION

CE TEST CERTIFICATION

CE EMC Test Certification

APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST

9. Electrostatic Discharge Immunity Test (ESD)

CE EMC TEST REPORT. according to

EMC TEST REPORT. according to

ELECTRONICS TESTING CENTER(ETC), TAIWAN

CE EMC TEST REPORT. According to

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

FCC TEST REPORT. for. 47 CFR, Part 15, Subpart C. SPORTON International Inc.

FCC TEST REPORT. according to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class A Digital Device

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

CE TEST REPORT. according to

EMC TEST REPORT. according to

CE EMC TEST REPORT. according to. EN V1.4.1 ( ) and EN V1.2.1 ( ) Equipment : WIRELESS 11B CARDBUS CARD

FCC TEST REPORT Authorized under Declaration of Conformity

EMC TEST REPORT. according to

FCC TEST REPORT. for. 47 CFR, Part 2, Part 15 Subpart B and CISPR PUB. 22. SPORTON International Inc.

Declaration of Conformity

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC TEST REPORT. according to

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

CE EMC TEST REPORT. according to

CE EMC TEST REPORT. according to. EN V1.4.1 ( ) and EN V1.2.1 ( ) : WIRELESS 11B USB ADAPTER

C E R T I F I C A T I O N

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

FCC TEST REPORT. According to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class B Digital Device. Filing Type : Declaration of Conformity

FCC Part 15 Subpart B

CE EMC TEST REPORT. according to

FCC TEST REPORT Authorized under Declaration of Conformity

EMC COMPLIANCE TEST REPORT

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

CONFORMANCE TEST REPORT FOR EN /-6

Applicant : FIC (First International Computer, Inc.)

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

FCC TEST REPORT. according to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class B Digital Device. Equipment : IPC Bare Bone System

EMC TEST REPORT EN V1.4.1 ( ) EN V1.2.1 ( )

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

C E R T I F I C A T I O N

CE EMC TEST REPORT. according to

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT. According to

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

FCC 47 CFR PART 15 SUBPART B

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

IC Test Report. SPORTON INTERNATIONAL INC. No. 52, Hwa Ya 1 st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

TAIWAN TOKIN EMC ENG. CORP.

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

EMC TEST REPORT For Prokits Industries Co., Ltd.

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EN :2000+A2:2005, EN :1995+A1:2001

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

ELECTRONICS TESTING CENTER, TAIWAN

Test Report. : 09A255R-ITCEP28V01 Report Version : V1.0

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Report No.: 11A080304E-E Page 1 of 35. CE Test Report. (Declaration of Conformity) for. Electromagnetic Compatibility.

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

C E R T I F I C A T I O N

CE EMC TEST REPORT. for. IPC Model: IPC-619S; IPC-619XXXXXXXXXXXX; SYS-4U619X-XXXXXXXXXX (X = 0-9, A-Z or Blank) Test Report Number: E

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Test Report. Applicant : ICP DAS Co., LTD Address : No. 111, Kuang-Fu N. Rd., Hsin-Chu Industrial Park, Hukou Shiang, HSINCHU 303, Taiwan

Test Report : ITB-010

Report No.: 9A042401C1 Page 1 of 51. Test Report. EN 50155: 2007 (EMC, Characteristic, Environmental Test) Prepared for

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC VERIFICATION SUMMARY Report No.: SZHH

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

SPORTON International Inc.

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

FCC 47 CFR PART 15 SUBPART C ANSI C63.4: 2009

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EN :2000, EN :1995+A1:2001

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

CE EMC TEST REPORT. according to

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

Transcription:

according to Certification No.: EC78C004-01 European Standard EN 55022:2006 Class A, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003 ( IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-4:1995/A2:2001, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000, IEC 61000-4-11:1994/A1:2000 ). Equipment Model No. Applicant : Switching : PA1, PA3, PF, PW, PWH, PWWH, PPF, TW, TWP, TWK, TWL, AXE-0, AXE-1, AXE-2, AXE-4, SL, SL2, SMMTR, SMFTR, SMATR, SMDF, MRT-B, MMX-D, MM2D-D, MMCS, MCS, MMP-3, MMP-3VI : Axe Technology Corp. No.70, Lane 83, Hwa Chen Road, Hsing Chuang City, Taipei Hsien, Taiwan I HEREBY CERTIFY THAT : The measurements shown in this test report were made in accordance with the procedures given in EUROPEAN COUNCIL DIRECTIVE 2004/108/EC. The equipment was passed the test performed according to European Standard EN 55022:2006 Class A, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003 ( IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-4:1995/A2:2001, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000, IEC 61000-4-11:1994/A1:2000 ). The test was carried out on Sep. 03, 2007 at SPORTON INTERNATIONAL INC. LAB. Castries Huang Supervisor SPORTON INTERNATIONAL INC. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. TEL:886-2-2696-2468 Fax:886-2-2696-2255 ISSUED DATE: Mar. 21, 2011

APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST A.1. APPLICANT Axe Technology Corp. No.70, Lane 83, Hwa Chen Road, Hsing Chuang City, Taipei Hsien, Taiwan A.2. MANUFACTURER Same as A.1. A.3. BASIC DESCRIPTION OF EQUIPMENT UNDER TEST Equipment Model No. Trade Name Power Supply Type DC Power Cable : Switching : PA1, PA3, PF, PW, PWH, PWWH, PPF, TW, TWP, TWK, TWL, AXE-0, AXE-1, AXE-2, AXE-4, SL, SL2, SMMTR, SMFTR, SMATR, SMDF, MRT-B, MMX-D, MM2D-D, MMCS, MCS, MMP-3, MMP-3VI : AXE : Switching : Non-Shielded, 1.8m, 2pin

A.4. FEATURE OF EQUIPMENT UNDER TEST

APPENDIX B. GENERAL INFORMATION OF TEST B.1. TEST FACILITY < EMI > This test was carried out by SPORTON International Inc. Test Site Location : No. 3, Lane 238, Kang Lo Street, Nei Hwu District, Taipei 11424, Taiwan, R.O.C. TEL : 886-2-2631-4739 FAX : 886-2-2631-9740 Test Site No : CO01-NH, OS01-NH < EMS > Test Site Location : 3F, No. 587, Tanmeu St., Neihu District, Taipei, Taiwan, R.O.C. TEL : 886-2-2794-8886 B.2. TEST VOLTAGE 230V / 50Hz B.3. STANDARD FOR METHODS OF MEASUREMENT EMI Test (conduction and radiation) : European Standard EN 55022 Class B Harmonics Test : European Standard EN 61000-3-2. Voltage Fluctuations Test : European Standard EN 61000-3-3. EMS Test : European Standard EN 55024 ( ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, Surge: IEC 61000-4-5, CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, Dips: IEC 61000-4-11 ) B.4. TEST IN COMPLIANCE WITH EMI Test (conduction and radiation) : European Standard EN 55022 Class B Harmonics Test : European Standard EN 61000-3-2. Voltage Fluctuations Test : European Standard EN 61000-3-3. EMS Test : European Standard EN 55024 ( ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, Surge: IEC 61000-4-5, CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, Dips: IEC 61000-4-11 ) B.5. FREQUENCY RANGE INVESTIGATED a. Conducted emission test: from 150 KHz to 30 MHz b. Radiated emission test: from 30 MHz to 1000 MHz c. Radio frequency electromagnetic field immunity test: from 80 MHz to 1000 MHz B.6. TEST DISTANCE a. The test distance of radiated emission test from antenna to EUT is 10 M b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M

APPENDIX C. TEST RESULT C.1. Test of Conducted Powerline The CONDUCTED EMISSION test was passed at Frequency ( MHz ) Line Meter Reading Limits Margin or Q.P. A.V. Q.P. A.V. Q.P. A.V. Neutral ( dbuv ) ( dbuv ) ( dbuv ) ( dbuv ) ( db ) ( db ) 1.027 Line 20.56 16.41 73.00 60.00-52.44-43.59 C.2. Test of Radiated Emission The RADIATED EMISSION test was passed at Frequency Limits Emission Margin Antenna TurnTable Polarity ( MHz ) (dbuv/m) (dbuv/m) ( db ) High Degree 854.400 Vertical 47.00 31.77-15.23 2.01m 187 C.3. Current Harmonics Test As specified on clause 7 and figure Z1 of EN 61000-3-2:2000, the limits are not specified for equipment with a rated power of 75W or less. The EUT meets the above condition, so it conforms to EN 61000-3-2.

C.4. Test Result Of Voltage Fluctuation And Flicker Test Urms = 230.1V Freq = 50.000 Range: 0.25 A Irms = 0.010A Ipk = 0.022A cf = 2.141 P = 1.344W Pap = 2.388VA pf = 0.563 Test - Time : 1 x 10min = 10min ( 100 %) LIN (Line Impedance Network) : SLIN 0.24ohm +j0.15ohm N:0.16ohm +j0.10ohm Limits : Plt : 0.65 Pst : 1.00 dmax : 6.00 % dc : 3.30 % dtlim : 3.30 % dt>lim: 500ms Test completed, Result: PASSED Plt = 0.072 Pst P50s P10s P3s P1s P0.1s dmax dc dt>lim [%] [%] [ms] 1 0.072 0.010 0.010 0.010 0.010 0.010 0.000 0.000 0.000 C.5. ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) Required Performance Criteria : B C.6. RADIO FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY TEST (RS) Required performance criteria : A

C.7. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (EFT/BURST) CE EMC CERTIFICATION Required performance criteria : B C.8. SURGE IMMUNITY TEST Required performance criteria : B C.9. CONDUCTED DISTURBANCES INDUCED BY RADIO-FREQUENCY FIELD IMMUNITY TEST ( CS ) Required performance criteria : A C.10. POWER FREQUENCY MAGNETIC FIELD IMMUNITY TESTS Required performance criteria : A C.11. VOLTAGE DIPS AND VOLTAGE INTERRUPTION IMMUNITY TESTS Pass Performance Criteria : C for voltage interruption, A for voltage dips Required performance criteria : C for voltage interruption, B/C for voltage dips Observation : After the interruption, the power of EUT reset automatically.

APPENDIX D. TEST INSTURMENT D.1. EMI Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark Receiver R&S ESCS 30 100357 9 khz - 2.75 GHz Sep. 14, 2006 LISN AFJ NNB-2/16Z 99079 9kHz 30MHz Dec. 27, 2006 LISN KYORITSU KNW-407 8-1010-15 9kHz 30MHz Dec. 07, 2006 Power Filter CORCOM MR12030 N/A 30A*2 N/A RF Cable-CON Suhner Switzerland RG223/U CB004 9kHz 30MHz Dec. 15, 2006 Open Area Test Site SPORTON OATS-10 OS01-NH 30 MHz - 1 GHz 10m, 3m Nov. 18, 2006 Amplifier HP 8447D 2944A06292 0.1 MHz - 1.3 GHz Apr. 17, 2007 Spectrum Analyzer R&S FSP 100793 9 khz 30 GHz Dec. 15, 2006 Receiver R&S ESCS 30 100358 9 khz - 2.75 GHz Oct. 26, 2006 Bilog Antenna SCHAFFNER CBL6111C 2738 30 MHz - 1 GHz Dec. 20, 2006 Turn Table EMCO 1060-1.211 9507-1805 0-360 degree N/A Antenna Mast EMCO 1051-1.2 9503-1876 1 m - 4 m N/A RF Cable-R10m BELDEN RG8/U CB001 30 MHz - 1 GHz Oct. 11, 2006 Calibration Interval of instruments listed above is one year.

D.2. EMS Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark ESD Simulator KEYTEK MZ-15/EC 0302197 Air: 0 KV - 15 KV Contact: 0 KV -8KV Mar. 12, 2007 ESD Amplifier Amplifier Antenna Antenna INTEGRATED MEASUREMENT SYSTEM NRP-Z91 POWER SENSOR 6GHZ AMPLIFIER& RESEARCH AMPLIFIER& RESEARCH AMPLIFIER& RESEARCH AMPLIFIER& RESEARCH ROHDE& SCHWARZ ROHDE& SCHWARZ 150W1000 312366 80M~1GHz Aug. 31, 2006 RS 30S1G3 312505 80M~3GHz Aug. 31, 2006 RS AT1080A 312637 80M~1GHz Sep. 14, 2006 RS AT4002A 312601 80M~5GHz Sep. 14, 2006 RS IMS 100007 9kHz~3GHz Aug. 24, 2006 RS 1168.8004.02 100095 9kHz~3GHz Aug. 24, 2006 RS EFT Generator KEYTEK EMCPRO 0609221 0 KV - 4.4 KV Sep. 07, 2006 EFT SURGE Generator Bi-Wave KEYTEK EMCPRO 0609221 0 KV -6 KV/2 0KV-500V/12 Sep. 07, 2006 SURGE SURGE/CDN KEYTEK EMCPRO 0609221 0 KV -4 KV/2 0KV-500V/12 Sep. 07, 2006 SURGE SURGE Generator Ring-Wave KEYTEK EMCPRO 0609221 0 KV -6 KV/2 0KV-500V/12 Sep. 07, 2006 SURGE CS FRANKONIA CIT-10 102C3115 100 khz - 266 MHz Sep. 06, 2006 CS Attenuator EM TEST 75W-DC-250 MHz 06 0004166A 150 khz - 230 MHz May 25, 2007 CS Koppel- Eutkoppelnetzwerk Magnetic Field Antenna FRANKONIA CDN M2+M3 A3011018 150k~230MHz May 18, 2007 CS FCC F-1000-4-8/9/10-L-1M 9830 0~125A Apr. 02, 2007 Magnetic Magnetic Generator FCC F-1000-4-8-G-125A 05004 0~125A Apr. 02, 2007 Magnetic 230VA/50Hz/60Hz 0%Open/5S PQF Generator KEYTEK EMCPRO 0609221 0%Short/5S 40%0.10S 70%/0.01S Sep. 07, 2006 DIP Harmonic/Flicker Test System EMC PARTNER Harmonics -1000 088 4000VA 16A PEAK Sep. 01, 2006 Harmonics, Flicker Calibration Interval of instruments listed above is one year.