SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

Similar documents
} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

SPECIFICATION SHEET. 2-WIRE TYPE ph ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

Dissolved Oxygen Transmitter

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H

Industrial Conductivity (Electric Conductivity) Detector

High-sensitivity with vertical hole. PFA 2.6/cm (260/m) C 1.0 MPa or less Approx. 19kg Approx. 10kg (L: 500) Outdoor installation Rainproof type

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Process ph/orp Analysis Systems

MODEL EPM-96 EPM-96F. ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display)

Digital conductivity transmitter

Ultrasonic level transmitter, non-contact

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Electro-Magnetic Flowmeters COPA-XE

DissolvedOxygenMonitor

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

GC83 Digital Indicators & GC93 Digital Meter Relay

ThermoPLUS Smart Temperature Transmitter

DISSOLVED OXYGEN TRANSMITTER

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

ph or ORP Transmitter

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

General Specifications

LST400 Ultrasonic level / open channel flow transmitter

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

General Specifications

ANALYTICAL - COMPLEXITY MADE SIMPLE

Conductivity Analyzer

INSTRUCTION MANUAL ADMITTANCE LEVEL LIMIT SWITCH LEVTESTER - SLA SERIES Models SLA-122/222/322/622/522/722

Conductivity Transmitter

Rod probe With coaxial tube reference probe

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

General Specifications

Inteligent Digital Transmitter TMD Series

General Specifications

Digital inductive conductivity transmitter

Series 10-ZSE30A(F)/10-ISE30A

Measuring and Controlling Unit Multronic OC

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

PAD - Heavy Duty Differential Pressure Trasmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

FLOWPET-NX (Oil Service Mechanical Register)

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Design and applications

SIA, SIB, SIC, SID. User's Manual

KFS. Flap-type flow meter. Design and range of application

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Level gauges Series LT Level indicator, switch and transmitter for liquids

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Digital flow transmitter for continuous flow measurement

Open Channel Flowmeter 713

GRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F

Series 10-ZSE80/10-ISE80

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

SHIMADEN DIGITAL INDICATORS

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Target disk flowmeter for liquids and gases

ABB ph/orp analyzer and probe package

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

General Specifications

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Sitron Capacitive Level Sensors

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

The transducer component converts the measured signal and displays the actual value.

4-20mA, 0-10V and general process measuring bargraph displays

General Specifications

RCM DIRECT READING FLOWMETER

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

1000TR. Instructions

Using the AcuDew Moisture Transmitter

LST100 Ultrasonic level transmitter for upstream oil and gas

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Metal tube variable area flowmeters for gases, liquids and steam

Parts Per Million Dissolved Oxygen Systems

FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

General Specifications

Electromagnetic Flow Transmitter

mass flowmeter for compressed air

CROSS STACK LASER GAS ANALYZER

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

PTG series Smart Pressure Transmitter

Transcription:

ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs and outputs, digital display and rainproof construction. Simple span calibration: The instrument can be calibrated in one action by virtue of memory resistant saturated DO (Dissolved Oxygen) data stored in the memory. The built-in stabilization determination function enables the unit to be accurately calibrated preventing operator error. Automatic determination of electrode quality: During calibration, the electrode quality is automatically evaluated. An error message is generated when the electrode quality deteriorates to an unacceptable level. Output range adjustment, the output range can be easily reconfigured. Output signal can be frozen during maintenance work. By switching to ST-BY (Stand By) mode the output value can be held to avoid disruption to the process control system. Facility to receive external contact switching signal to hold output (for example, during electrode cleaning etc). STANDARD SPECIFICATIONS Product Name : DO Analyzer/Transmitter (for industrial use). Model : ODM-36A. Measurement Ranges : 0~/2/5/0/5/20/25/30 mg/l (output ranges) Indication : Digital indication on LCD. Resolution : 0.0mg/L. Linearity : Within ±%FS, with equivalent input (0~ and 0~2mg/L range is within ±0.05mg/L) Temp. Compensation Range : 0~45 C. Temperature Compensation Accuracy : Within ±3%FS to 0~45 C. (Dependant on equivalent input of electrode). Output Ambient Conditions Power Supply : 4~20mA DC Isolated (load resistance 650Ω or less). : -20~55 C, 99%RH or less. : AC 90~32V 50/60Hz or AC 80~264V 50/60Hz. : Approx. 3VA. : Approx. 3kg. : Outdoor Installation, IP55. : Mounted on a 50A pipe. : G 3 /4 (PF 3 /4F) 3 ports. Power Consumption Installation Mounting Cable Port Materials of Construction Main Body : Cast aluminium Alloy. Window : Resin. Paint Colour : Metallic silver and blue. External hold command input : Receiving hold signal from water jet cleaner to hold 4~20mA output during cleaning cycle. SYSTEM CONFIGURATION Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0 Page

DIMENSIONS Units: mm WIRING CONNECTIONS Connection terminals 3.4: Cleaning start signal Contact pulse of 00ms or longer closure time Internal load relay: 00V AC 30mA 5.6: Cleaning stop signal Stops when open. Closed when shipped. Internal load solenoid: 00V AC 250mA a: To start cleaning by external signal, apply the contact signal here. (Contact rating: 00V AC A contact pulse of 00ms or longer) b: To stop cleaning, open between the contacts. (Shorten normally) Page 2 Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0

TERMINAL CONNECTIONS PRODUCT CODE ODM-36A-0-2 Codes for custom specifications: Number: 9 Letter: Z Y A B C 0 2 3 A B C 0 0 Power Supply * AC 90V~32V 50/60Hz AC 80V~264V 50/60Hz Output DC 4~20mA Measurement range (output range) *2 0~50mg/L (free setting) *2 Customer specify Combined electrode *3 7533L, 7699L (General use) 7536L,7695L,7546L (for sewage applications) For fermentation use (765*L/766*L etc.) Cable port adapter Nil G 3 /4 (PF 3 /4) Standard G /2 (PF /2) SUS-304 adapter NPT /2 SUS-304 adapter NPT 3 /4 SUS-304 adapter Electrode lead port *4 For electrode lead (OD 8mm), direct connection For electrode lead (OD 6mm), direct connection For extension cable (combination with FC-4) Sun shade *5 Nil Yes Markings Standard (Japanese) English Notes: *. Multi-voltage power supply either AC00V-based or AC200V-based. *2. Measurement (output) range: It is possible to set nine ranges freely including: [0~/2/5/0/5/20/25/30/50mg/L]. If the setting is not specified the unit will be shipped configured for range of [0~0mg/L.] If a specific range is required then select Product Code Y:SPECIFY and then input the required range. *3. Combined electrode 7546L is for float system detector (FOC-7). *4. Combined electrodes 7533L/7536L/7546L have 8mm OD leads. Electrodes 7695L/7699L/ (for fermentation) have 6mm OD leads *5. The instrument should be installed in ambient temperatures not exceeding 45 C and protected from strong sunlight. Caution:. Input termincals or external output hold command are provided as standard (no need to combine with cleaing function detector Model OC- 7etc). Please refer to appropriate sections (Wiring Connections) for detailed wiring information. For wiring details please refer to the wiring diagram and the instruction manual. 2. Temperature compensation resistance of combined electrode is 0 KΩ [TC=0 KΩ]. Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0 Page 3

RELATED EQUIPMENT Dissolved Oxygen Electrodes Diaphragm Polalograph type. The system has the following features: Durable, very safe and diaphragm replacement is easy. These electrodes give very reliable measurement and have minimum maintenance requirements. It is also possible to use these electrodes for general applications as well as for oxygen applications. DISSOLVED OXYGEN (OXYGEN) ELECTRODE TABLE Applications General Tank General Use Low concentration Organic Solvent General Tank/ Sewage Applica tion Food Process Pure water boiler Model 7533L 7536L 7546L 7538L 7535L 7539L Classification Recycling System Materials Main PVC, PE,SUS 36 Polysalhon, SUS 36 SUS 36 Diaphragm PTFE, FEP Sample Condition Temp. 0~45 o C Pressure 0.3MPa or less 0.5M Pa or less Flow speed 0cm/s or more, at the point of electrode Heat Resistance 50 o C 95 o C 90% Respond Time Approx. 60s (25 o C) Approx. 80s (25 o C) Approx, 20s (25 o C) Linearity Within ±3%of air saturation value (temperature fixed) Repeatability Within ±2%of air saturation value (temperature fixed) Combination lead ELW - 2 or ELW - 23 ELW - 2 Combination Holder OC - 7, JOC - 7B, etc.. FOC - 7 [ ] [ ] OC - 64, etc.. Flow cell The above table shows the list of electrodes to be used with the microprocessor type detector. The combination lead is 5m (standard). Combined Detector Refer to electrode and electrode holder for DO amplifier B507-08-[ ] [ ] for details. Immersion Immersion Flow through Flow through Throw in Throw in Product name Type DO Type DO type DO type DO type DO type DO electrode electrode electrode electrode electrode electrode holder holder holder holder holder holder Model OC- 7 FOC- 7/72 NOC- 84 NOC- 85 OC- 99 OC- 950 Installation Immersion type Float system vertical type (FOC- 7) Float system arm type (FOC- 72 Service Sample 0~45 o C (No freezing) Temperature range Ambient - 5~50 o C Service pressure range 0.03MPa or less Atmosphere Approx. 30kg Approx. kg (FOC- 7, (total length Approx. 20kg m) (FOC- 72 Combined electrode 7533L (General) 7536L (Sewage application) 7546L General sewage Flow through type 0.5MPa or less Approx. 2kg 0.3MPa or less Approx.5kg Throw in type 0.MPa or less Approx. 3kg (protector tube 2m) 7533L (General) or 7536L (Sewage application) Approx 7kg (protector tube 5m) Materials in contact with sample Process Connection Holder: PVC, PP Float main body: PVC, etc.. Holder: PVC, PP Case: PVC 25A JIS 0K FF Holder: PVC, PP Case: SUS36 25A JIS 0K RF Detector: SUS 36, PVC, PP Protector tube: PVC Page 4 Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0

Electrode holder with jet-cleaner (JOC series) This holder provides a water or air jet spray to the electrode tip to remove electrode fouling. The cleaning interval can be altered by setting the built-in timer. Cleaning start and finish can also be controlled by external contact switching signals. Both immersion and flow-through types of electrode holder are available. Both types feature rainproof construction. Product Name DO electrode holder with jet- cleaner DO electrode holder with jetcleaner Throw- in type DO electrode holder with jet-cleaner Model JOC- 7B JOC- 8B JOC- 950A Cleaning method Intermittent air or water jet cleaning Mounting method Immersion type Flow- though type Throw- in type Temp. Sample 0~45 o C (no freezing) range Ambient 0~50 o C Pressure range Below 0.03MPa Below 0.3MPa Below 0.MPa Cleaning cycle ~3h (up to 2h available as option) Cleaning time 0.6~4min/cleaning (jet cleaning time adjustable between 30~60s) Pressure 0.05~0.5MPa (sample pressure + 0.05~0.MPa) Cleaning Water.4~3.5L/min water/air Consumption Air 6~0L/min Power source 00V AC ±0%, 50/60Hz Power consumption Approx. 25VA Approx. 20kg Approx. 7kg Approx. 9kg (protection tube; (total length; m) 5m) Electrode 7533L or 7536L Wetted part material Holder; PVC, PP, Case; SUS36 Holder; PVC, PP, Case; SUS6 Sensor; SUS36, PVC, PP Protection tube; SUS304 Paint colour Metallic silver Construction Rain proof construction Connection - 25A JIS 0K RF - JUNCTION BOX When the transmitter is installed remotely to the sensor (mainly for panel mounted transmitters) and the standard electrode lead length is too short, a junction box is required. Model : FC-4 Construction : Field installation, spray proof (JIS CO920) Mounting : 25~50A Pipe, wall or panelmount Material : ABS resin Finish : Matted chromium plating, metallic silver : Approx. 0.9kg Applicable extension cable : EC-0 EXTENSION CABLE The extension cable is a special cable specifically manufactured for use with ph analysers. It is used for connection between transmitter and junction box. Maximum cable length is 00m. The cable must not be spliced. FC-4 EC-0 Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0 Page 5

BARGRAPH METER RELAY Model : 94 Output Signal : 4~20mA DC Alarm Outputs : High-high, high, low, low-low. (Contact rating: 25V, 0.5A) Scale : Specify with purchase order. Scale Length : 00mm Display : Red LED, 0 dots. Power Requirements : 85~264V AC, 50/60Hz Power Consumption : Approx. 7VA Ambient Conditions : 0~45 o C, 40~80% RH : Approx 420g SUN-SHADE (For protection from direct sun-light) Material : 304 Stainless Steel Mounting : 50A Pipe bracket Model 94 DKK-TOA CORPORATION Do not operate products before consulting instruction manual. International Operations: DKK-TOA Corporation 29-0, -Chome, Takadanobaba, Shinjuku-ku, Tokyo 69-8648 Japan Tel: +8-3-3202-0225 Fax: +8-3-3202-5685 Representative Office (Europe): DKK-TOA European Representative St. Johns Innovation Centre, Cowley Rd., Cambridge CB4 0WS UK. Tel : +44 (0)223-52647 Fax : +44 (0)223-709239 http://www.toadkk.co.jp Information and specifications are for a typical system and are subject to change without notice. Page 6 Model: ODM-36A - Dissolved Oxygen Analyzer/Transmitter - Issue: ODM-36A-007-R0