Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

DWDM SFP+ Transceiver With Digital Diagnostic Function

SNR-SFP+LR-2 10Gbps. Applications 10GBASE-LR at 10.31Gbps 10GBASE-LW at 9.95Gbps Other optical links

XFP-BIDI-xx-10D. 10Gbps XFP Bi-Directional Transceiver, 10km Reach

4.25Gbps SFP Transceiver

DWDM SFP+ Series DWDM EML DWDM EML

DWDM SFP+ Series. EOLP XXXN series. Features. Applications. Ordering Information

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

DWDM SFP+ Series. EOLP XXXN MSA Series. Features. Applications. Ordering Information

2.5Gbps SFP Transceiver

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

OCTECH 1.25Gbps SFP Transceiver

DWDM SFP+ Series EOLP XXN MSA Series

XFP BIDI Series JB1330-XFP-LC.S60. Features. Applications. Ordering information. Regulatory Compliance

10Gb/s DWDM Single-mode SFP+ Transceiver

DWDM SFP Series. Laser

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

OCTECH 1.25Gbps SFP Transceiver

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

XFP-10GB-LR. 10Gbps XFP Optical Transceiver, 10km Reach

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

1.25Gbps SFP Transceiver

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP+ Series EOLP XN MSA Series

4.25G 2km BIDI SFP Series

XFP Series JD1310-XFP-LC.S10. Features. Applications. Ordering information

CWDM EML. SMF 23dB YES LC. note1: X refers to CWDM Wavelength range 1470nm to 1610nm, X=K~R, denotes 1470~1610nm.

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP Series. EOLS X Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1xFC /GBE Duplex SFP Transceiver RoHS6 Compliant

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

LEG. 10Gbps SFP+ Transceiver

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

10Gbps 1550nm 80KM SFP+ Optical Transceiver

KRN-SF-SM GD 10G SFP+ ER

STM-1/OC-3 Bidirectional SFP Transceiver With Digital Diagnostic Function. Features: Applications: Product Description

SFP-10G-SR-LEG. 10Gbs SFP+ Transceiver

SDH STM-1/SONET OC-3 SFP Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

Part No. Data Rate Fiber Distance Interface Temperature DDMI

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

XBR C. 8Gbs SFP+ Transceiver

WDM SFP+ модули предназначены для создания каналов связи по одноволоконному SM кабелю на расстояние до 20км.

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

Laser TX/RX. Laser. Fiber Temp Rate. (nm)

LEG. 10Gbs SFP+ Transceiver

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

SNR-XFP-WXX-40 10Gbps

Ousent Technologies Co,.Ltd

SNR-XFP-DXX-40 10Gbps

DWDM SFP Series. Laser

SFP+ Series EOLP M-I. Features. Applications. Ordering information

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SFP+ Tunable Preliminary. EOLP-1696-TDW-23XXXN MSA Series. Features. Applications. Ordering Information

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

10GBASE-LR/LW SFP MSA SFF-8472 SFF-8431 SFF-8432 Compliant

SFP-10GCWZR-xx-TP 10Gb/s CWDM SFP+ 80km Transceiver

PRODUCT SPECIFACTION

DWDM XFP Series XFPD-ER. XFP Single-Mode Dual Fiber DWDM Transceiver for 10GbE/10GFC/SDH/SONET. Features. Applications. Product Description

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

Data Sheet. GPON OLT CLASS B+/C+ Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

Fiber Distance* (note2) Interface Temperature DDMI Rate

Part Number Operating Case temperature DDMI. ESD to the Electrical PINs: compatible with MIL-STD-883 Method 3015

Part No. Data Rate Media type Distance

PRODUCT SPECIFICATION

TSP-EB66-xxxxS. Data Sheet. 1.25G GEPON OLT Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

SFP- 10G- GIG- SR- AO. 10Gbs SFP+ Transceiver

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial

SFP-BIDI G 1310/1490nm BIDI

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

SO-SFP-10GE-BX10D-3327-E

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

AXM762-A AXM762-A. Features. Up to 11.1Gbps Data Links. Up to 10km transmission on SMF. DBF Laser and PIN receiver. Metal enclosure, for lower EMI

XTBxxA-20LY 10 Gbps SFP+ Bi-Directional Transceiver, 20 km Reach

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

PRODUCT SPECIFICATION

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

BC-BL 35(53)12-20 SFP BIDI 1.25G 1310/1550nm (1550/1310nm) DDM 20KM Transceiver

Transcription:

SFP+-DWDM-xx-80D 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach Features Available in all C-Band Wavelengths on the 100GHz DWDM ITU Grid Temperature-Stabilized DWDM EML Transmitter Duplex LC Connector Power Dissipation < 1.5 W Dispersion tolerance from -500ps/nm to 1600ps/nm Hot-Pluggable SFP+ Footprint Operating Case Temperature Standard : 0 C to +70 C Compliant with SFF-8431 MSA Compliant with SFF-8432 MSA Applications 10GBASE-ZR/ZW 10G FC Other optical links Description The SFP+-DWDM-xx-80D series single mode transceiver is small form factor pluggable module for duplex optical data communications. This module is designed for single mode fiber and operates at a nominal DWDM wavelength from 1528nm to 1566nm as specified by the ITU-T. It is designed to deploy in the DWDM networking equipment in metropolitan access and core networks. It is with the SFP+ 20-pin connector to allow hot plug capability. The transmitter section uses a DWDM EML laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses a PIN detector and a limiting post-amplifier IC. The SFP+-DWDM-xx-80D series are designed to be compliant with SFP+ Multi-Source Agreement (MSA) Specification SFF-8431. 1/11

Absolute Maximum Ratings *Note Parameter Symbol Min Max Unit Supply Voltage Vcc -0.5 3.6 V Storage Temperature Ts -40 +85 C Operating Relative Humidity 95 % Note: Exceeding any one of these values may destroy the device immediately. Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Tc 0 +70 C Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc 300 430 ma Baud Rate 10.3 Gbps Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter CML Inputs(Differential) Vin 250 1000 mvpp After internal AC coupling Input Impedance (Differential) Zin 85 100 115 ohm Rin > 100kohm @ DC TX_Dis Disable 2 Vcc+0.3 V Enable 0 0.8 V TX_FAULT Fault 2 Vcc+0.3 V Normal 0 0.5 V Receiver CML Outputs (Differential) Vout 350 700 mvpp AC coupled output Output Impedance (Differential) Zout 85 100 115 ohm RX_LOS MOD_DEF (0:2) LOS 2 Vcc+0.3 V Normal 0 0.8 V VoH 2.5 V VoL 0 0.5 V With Serial ID 2/11

Optical Characteristics Parameter Symbol Min Typical Max Unit Data Rate 10.3 Gbps Center Wavelength Spacing Transmitter 100 GHz 0.8 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power Note1 P out 0 5 dbm Average Power of OFF Transmitter -30 dbm Extinction Ratio ER 3.5 db Transmitter and Dispersion Penalty TDP 3.5 db P out @TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -128 db/hz TX Jitter TXj Per 802.3ae requirements Receiver Receiver Sensitivity Note2 P min -23 dbm Receiver Overload P MAX -6 dbm LOS De-Assert LOS D -24 dbm LOS Assert LOS A -40 dbm LOS Hysteresis 1 db Note1: Output is coupled into a 9/125um SMF. Note2: Minimum average optical power measured at the BER less than 1E-12. The measure pattern is PRBS 2 31-1 3/11

DWDM Wavelength Guide Table 1- DWDM Wavelength Guide ITU Channel Product Code Frequency (THz) Wavelength (nm) ITU Channel Product Code Frequency (THz) Wavelength (nm) 17 191.7 1563.86 40 194.0 1545.32 18 191.8 1563.05 41 194.1 1544.53 19 191.9 1562.23 42 194.2 1543.73 20 192.0 1561.42 43 194.3 1542.94 21 192.1 1560.61 44 194.4 1542.14 22 192.2 1559.79 45 194.5 1541.35 23 192.3 1558.98 46 194.6 1540.56 24 192.4 1558.17 47 194.7 1539.77 25 192.5 1557.36 48 194.8 1538.98 26 192.6 1556.55 49 194.9 1538.19 27 192.7 1555.75 50 195.0 1537.40 28 192.8 1554.94 51 195.1 1536.61 29 192.9 1554.13 52 195.2 1535.82 30 193.0 1553.33 53 195.3 1535.04 31 193.1 1552.52 54 195.4 1534.25 32 193.2 1551.72 55 195.5 1533.47 33 193.3 1550.92 56 195.6 1532.68 34 193.4 1550.12 57 195.7 1531.90 35 193.5 1549.32 58 195.8 1531.12 36 193.6 1548.51 59 195.9 1530.33 37 193.7 1547.72 60 196.0 1529.55 38 193.8 1546.92 61 196.1 1528.77 39 193.9 1546.12 Note: Please contact with OPTONE for the channel availability. 4/11

SFP+ Transceiver Electrical Pad Layout 5/11

Pin Descriptions Pin Signal Name FUNCTION Plug Seq. Notes 1 VeeT Transmitter Ground 1 Note 5 2 TX Fault Transmitter Fault Indication 3 Note 1 3 TX Disable Transmitter Disable 3 Note 2 4 SDA Module Definition 2 3 2-wire Serial Interface Data Line. 5 SCL Module Definition 1 3 2-wire Serial Interface Clock. 6 MOD_ABS Module Definition 0 3 Note 3 7 RS0 RX Rate Select (LVTTL). 3 Rate Select 0, optionally controls SFP+ module receiver. This pin is pulled low to VeeT with a >30K resistor. 8 LOS Loss of Signal 3 Note 4 9 RS1 TX Rate Select (LVTTL). 1 Rate Select 1, optionally controls SFP+ module transmitter. This pin is pulled low to VeeT with a >30K resistor. 10 VeeR Receiver ground 1 Note 5 11 VeeR Receiver ground 1 Note 5 12 RD- Inv. Received Data Out 3 Note 6 13 RD+ Received Data Out 3 Note 6 14 VeeR Receiver ground 1 Note 5 15 VccR Receiver Power Supply 2 3.3V ± 5%, Note 7 16 VccT Transmitter Power Supply 2 3.3V ± 5%, Note 7 17 VeeT Transmitter Ground 1 Note 5 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 VeeT Transmitter Ground 1 Note 5 Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT/R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7K 10 KΩ resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Module Absent, connected to VeeT or VeeR in the module. 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT/R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) The module signal ground contacts, VeeR and VeeT, should be isolated from the module case. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 350 and 700 Mv differential (175 350 Mv single ended) when properly terminated. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP+ connector pin. Maximum supply current is 680Ma. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP+ input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP+ transceiver module will result in an inrush current of no more than 30Ma greater than the steady state value. VccR and VccT may be internally connected within the SFP+ transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 150 1200 Mv (75 600Mv single-ended). 6/11

Digital Diagnostic Interface Definition The optical transceiver contains an EEPROM. It provides access to sophisticated identification information that describes the transceiver s capabilities, standard interfaces, manufacturer, and other information. The serial interface uses the 2-wire serial CMOS EEPROM protocol. When the serial protocol is activated, the host generates the serial clock signal (SCL, Mod Def 1). The positive edge clocks data into those segments of the EEPROM that are not writing protected within the SFP+ transceiver. The negative edge clocks data from the SFP+ transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Alarm/warning threshold data is written during device manufacture. TEC current monitoring, laser temperature monitoring, received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and transceiver temperature monitoring all are implemented. The diagnostic data are internal calibration and stored in memory locations 96 109 at wire serial bus address A2h. The transceiver memory map specific data field defines as following. 7/11

Recommended Interface Circuit 8/11

Mechanical Dimensions Laser Emission 9/11

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI) Immunity Laser Eye Safety Component Recognition RoHS6 MIL-STD-883G Method 3015.7 EN 55024:1998+A1+A2 IEC-61000-4-2 GR-1089-CORE FCC Part 15 Class B EN55022:2006 CISPR 22B :2006 VCCI Class B EN 55024:1998+A1+A2 IEC 61000-4-3 FDA 21CFR 1040.10 and 1040.11 EN (IEC) 60825-1:2007 EN (IEC) 60825-2:2004+A1 UL and CUL EN60950-1:2006 2002/95/EC 4.1&4.2 2005/747/EC 5&7&13 Class 1C (>1000 V) Compliant with standards Compliant with standards Noise frequency range: 30 MHz to 6 GHz. Good system EMI design practice required to achieve Class B margins. System margins depend on customer host board and chassis design. Compliant with standards. 1kHz sine-wave, 80% AM, from 80 MHz to 1 GHz. No effect on transmitter/receiver performance is detectable between these limits. CDRH compliant and Class I laser product. TüV Certificate No. 50135086 UL file E317337 TüV Certificate No. 50135086 (CB scheme ) Compliant with standards *note Note: For update of the equipments and strict control of raw materials, OPTONE has the ability to supply the customized products since Jan 1st, 2007, which meets the requirements of RoHS6 (Restrictions on use of certain Hazardous Substances) of European Union. In light of item 5 in RoHS exemption list of RoHS Directive 2002/95/EC, Item 5: Lead in glass of cathode ray tubes, electronic components and fluorescent tubes. In light of item 13 in RoHS exemption list of RoHS Directive 2005/747/EC, Item 13: Lead and cadmium in optical and filter glass. The three exemptions are being concerned for Optone s transceivers, because Optone s transceivers use glass, which may contain Pb, for components such as lenses, isolators, and other electronic components. 10/11

Ordering information Part Number Product Description SFP+-DWDM-xx-80D DWDM, 10Gbps, LC, 80km, 0 C~+70 C, With DDM Note: XX refers to DWDM Wavelength channel as ITU-T specified, please refer the Table 1- DWDM Wavelength Guide for detailed center wavelength information. Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by OPTONE before they become applicable to any particular order or contract. In accordance with the OPTONE policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of OPTONE or others. Further details are available from any OPTONE sales representative. sales@optone.net Edition Nov 05, 2013 Published by Copyright OPTONE All Rights Reserved 11/11