Emergency stops and safety stops

Similar documents
Emergency stops and safety stops

Emergency Stops. Shut down all machine functions! Protect machine during breakdown! Meet emergency stop regulations!

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Safety Light Curtain Orion1 Extended

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Accessories. Accessories

Complete units: Mushroom heads ø 22mm

Control Stations ø 22

Complete units: Push-buttons ø 22mm

Electronic Circuit Breaker with reset input ESS20-1..

Complete units: Selector switches ø 22mm

Local control stations for Zone 1 and Zone 21. Features. Description

Datasheet - PROTECT-IE-02

Operator Heads: ø 22mm

Operator Heads: ø 22mm

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

02/11/2015

Model Number Structure

Acceleration sensors With relay output for limit monitoring Analog / CANopen

02/11/2015

Separate units: Blocks

HMI Components. Series. Front mounting Glass mounting. Illuminated pushbutton Indicator Warning indicator Emergency call button. Public transportation

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Inductive sensor slot-type SI2-K08-AP7

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

PHOENIX CONTACT

02/11/2015

Original operating instructions Fail-safe inductive sensor GM705S

PD140FNT60QMU-02C. Through Beam. Main features. Description

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE

New Products Catalogue 2009 Safety Relays ESR5

OMRON MK-I / -S RELAY

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

General-purpose Relay

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PHOENIX CONTACT - 09/2009

General-purpose Relay

E-STOP relays, safety gate monitors

02/11/2015

The Best Relaytion. Cradle Relay N Rev. B EC-JM ECOC: JM10 1. Aug. 04

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Original operating instructions Fail-safe inductive sensor GG507S

Safety detection solutions Preventa

Incremental hollow shaft encoder BRIH EcoMag

The Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Product Data Sheet 3252J/2H3PU

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

CMM System - Encapsulated Modules

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

ACTUATOR LA36 PRODUCT DATA SHEET

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Diffuse reflection light scanner with background suppression. Dimensioned drawing. Electrical connection. see remarks!

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electronic Circuit Breaker ESS20-0..

PHOENIX CONTACT

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Actuator LA12 PRODUCT DATA SHEET

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

SAFETY LIGHT CURTAINS

Absolute Encoders Singleturn

maxon document number:

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

ORIGINAL INSTRUCTIONS

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

Technical data. General specifications. Measurement range min max. 360

Temposonics. Magnetostrictive Linear Position Sensors. EP2 IO-Link Data Sheet

Operating instructions Fail-safe delay timer AZS About this document. Content

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

Type Nominal voltage (V) Code HSV V

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Product Information ECN 424 S EQN 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Laser contrast scanner. Dimensioned drawing

Grundfos Direct Sensor

W 23-2: Focussing on what is essential and economic

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928


Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

TECHNICAL PRODUCT DATASHEET

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

E-STOP relays, safety gate monitors

SINEAX B 811 Power Pack with additional Functions

05/09/2014

XXXX e. X d.. X X X a

Transcription:

Emergency stops and safety stops

Contents Page Why do you need an Emergency stop? : Emergency stop for enclosure installation INC : Emergency stop for enclosure installation INC Tina : Emergency stop with LED Smile : Emergency stop with LED Smile Tina :0 Emergency stop with LED Smile S-i : Safety stop Inca and Smile : Reset button Smile R :7 7 8 9 0 Descriptions and examples in this book show how the products work and can be used. This does not mean that they can meet the requirements for all types of machines and processes. The purchaser/user is responsible for ensuring that the product is installed and used in accordance with the applicable regulations and standards. We reserve the right to make changes in products and product sheets without previous notice. For the latest updates, refer to www.abb.com/lowvoltage. 0. :

Why do you need an Emergency stop? So that anyone shall be able to stop a machine during a machine break-down or if someone is in danger. How do I recognise an E-stop? E-stop buttons shall according to relevant standards be red with a yellow background. n emergency stop grab wire shall be red for high visibility. sign that indicates the location of the E-stop shall be green with a white picture and possibly with text in the local country's language. How shall an E-stop stop the machine? n E-stop shall stop the machine as quickly as possible. To obtain a quick stop one either removes the power directly or one lets a frequency converter 'run down' and afterwards after a little delay, remove the power. n E-stop shall not create other hazards. Therefore a risk analysis must be made for the E-stop to be correctly connected. From 00//EC, clause...... This device must: - have clearly identifiable, clearly visible and quickly accessible control devices, - stop the hazardous process as quickly as possible, without creating additional risks, - where necessary, trigger or permit the triggering of certain safeguard movements.... Requirements for E-stops are stated in the following standards and regulations 00//EC The Machinery Directive Clause... in nnex gives requirements for the emergency stop function for new machines). See also clause.. Control devices. (see chapter Standard and Regulations ) Council Directive 89//EEC (with amendments) concerning the minimum safety and health requirements for the use of work equipment by workers at work Clause. gives the requirements for the emergency stop function for older machines. See also clause.. (see chapter Standard and Regulations ) EN ISO 80 Safety of machinery Emergency stop Principles for design harmonized standard that gives technical specifications for the requirements in the Machinery Directive. Could also be used for older machinery. EN 00- Safety of Machinery - Electrical equipment of machines Part : General requirements. Harmonized standard that gives requirements for the electrical equipment of machinery including the emergency stop actuator/function. Se clauses 9.. and 9... :

Emergency stop for enclosure installation INC pproval: pplication: CERTIFIED BY Emergency push button for installation in cabinets dvantages: Terminal blocks Emergency push button up to cat. /PL e acc. to EN ISO 89- Only mm's construction depth With LED info in print Push button IP, connector IP0 vailable as safety stop (black push button) 7 INC is an emergency stop designed for installation in. mm holes on cabinets. INC has potential free contacts for connection to safety relays. The connection is made in cabinets via a removable terminal which also have excellent measuring points. Inca is also available with a black pushbutton and used as a safety stop. See section on safety stops. In the emergency stop button there is a LED that displays current status on: Green = everything ok Red = this emergency push button has been pressed Off = a unit earlier in the circuit is affected 8 9 +V IQ 0 pulse I RT (+) S S () S S S INC Yellow front ring and emergency stop signs for emergency stop. 0 :

Emergency stop for enclosure installation INC Tina pproval: CERTIFIED BY pplication: Emergency push button for installation in cabinets dvantages: Terminal blocks Emergency push button up to cat. /PL e acc. to EN ISO 89- Only mm's construction depth With LED info in push button Info output (Inca Tina) Push button IP, connector IP0 vailable as safety stop (black push button) INC Tina is an emergency stop designed for installation in. mm holes in equipment cabinets. In addition to the INC version, "INC Tina" is also available with electronic adjustment of the dynamic safety loop for connection to the Vital and units. The connection is made in equipment cabinets via a removable terminal block which also has marked measuring points. Inca Tina is also available with black push button and is used in this case as a safety stop. See section on safety stops. The emergency stop button has a LED that displays the current status: Green = everything is OK Red = this emergency stop has been pressed. Flashing red/green = a protection device earlier in the loop has been actuated. Vital INC Tina +V IQ 0 pulse B T B R Yellow front ring and emergency stop signs for emergency stop. Info PLC :

Technical data - INC /INC Tina Manufacturer: rticle no./ordering data: INC INC Tina Impact resistance (half sinusoidal) Vibration resistance (sinusoidal) Climate resistance Damp heat, cyclical Damp heat, sustained Dry heat Cooling Salt mist Level of safety: Cat. /PL e Category SIL SIL PFH D : INC INC Tina: Colour: Weight: Size: Material: Temperature: Enclosure classification Installation: B/Jokab Safety, Sweden TL000R000 TL000R0000 Max. 0m/s², pulse width ms, -axis, acc. to EN IEC 008--7 Max. 0 m/s² at 0 Hz 00 Hz, 0 cycles, axis, acc. to EN IEC 008-- 9 hours, + C / 97%, + C / 9 % relative humidity, as per EN IEC 008--0 days, +0 C / 9 % relative humidity, as per EN IEC 008--78 9 hours, +70 C, as per EN IEC 008-- 9 hours, -0 C, as per EN IEC 008-- 9 hours, + C in a chemical solution with NaCl as per EN IEC 008-- EN ISO 89- EN 9- EN 0 IEC/EN 08-...7 PFH D :,0 0-0 PFH D :. 0-9 Yellow, red and black pprox. grams See drawing Polyamide P, Macromelt, Polybutylenterephthalate PBT UL 9 V0-0 C to + C (operation), -0 C to +70 C (storage) Print: IP, Connector: IP0, mm Emergency stop LEDs: INC : Green: Safety device OK. Not lit: unit earlier in the circuit is affected. Red: This emergency stop has been pressed. INC Tina: Green: Safety device OK, safety circuit OK Flashing: Safety device OK, safety circuit previously broken. Red: This button is pressed in, and the safety circuit is broken. Operating voltage (LED): Current consumption (LED): Emergency stop button Operating force: Operating movement: Contact material: INC : VDC INC Tina: VDC +% -% INC : m INC Tina: 7 m ± N pprox. mm to locked position Gold-plated silver alloy Minimum current: INC : 0 m, 0 VDC/0 VC INC Tina: Maximum current: INC : VDC INC Tina: Mechanical life: > 0 000 operations Standards: EN 00, EN 097-- & - EN ISO 80 ccessories: Front ring yellow for INC TL000R000 Emergency stop sign S D F,,mm TL000R000 Emergency stop sign E FT,,mm TL000R000 Conformity: 00//EG EN 9-, EN ISO 89-, EN 0, EN 00-, EN 9-, IEC 0-, EN 000--, EN 000--, EN 097--, EN 088 7 8 9 0 :

Emergency stop with indication Smile pprovals; CERTIFIED BY pplication: To stop a machine or a process Features: Smile - small and cost effective E-stop Emergency push button up to cat. /PL e acc. to EN ISO 89- With LED info in push button Robust Push button IP, housing IP7 vailable as safety stop (black push button) vailable for S-i In order to fulfil the need for a small and easy to install E-stop, Smile has been developed. The size of the device makes it possible to be installed wherever you want. With M connection/s or cable and centralised mounting holes Smile is very easy to install, especially on aluminium extrusions. Smile is available for E-stops in both dynamic and static safety circuits i.e. for interfacing to Vital/ and Safety relays. Each version is available with either one or two M connections or cable. t the top of Smile, a LED shows the current status as: green = protection OK, red = this emergency stop has been pressed and if the LED is off, an emergency stop earlier in the loop has been actuated. Smile is also available with black push button and is used as a safety stop. See section on safety stops. Smile emergency stop has six different variants:. Smile 0E has a m cable connected through the base of the unit.. Smile 0EK has four m short connecting leads through the base of the unit. No LED.. Smile E has a five-pole M connector on one end of the unit. lso available with S-i.. Smile E has two five-pole M connectors, one on each end of the unit.. Smile ER has one -pole M connector at one end.. Smile ER has two -pole M connectors at each end. Smile E adapted for S-i The Smile E also comes in a version adapted for direct attachment to the S-i bus. :

Connection examples Smile Smile 0E can be connected to either or a safety relay. Single channel example with LED indication. Safety category. The connection cable exits from underneath the unit. safety PLC +V (+) S Safety relay E.g. RT, RT9 Smile 0E Smile E can be connected to either or a safety relay. Single channel example with LED indication. Safety category. Connection via M connector. safety PLC +V Safety relay E.g. RT, RT9 Smile E can be connected to either or a safety relay. Single channel example with LED indication. Safety category. Connection via M connector + termination connector. S S (+) S S S Smile E Smile 0E can be connected to either or a safety relay. Two channel example with LED indication. Safety circuit category. safety PLC +V IQ 0 -pulse I (+) S Safety relay E.g. RT, RT9 Smile 0E Smile E can be connected to either or a safety relay. Two channel example with LED indication. Safety circuit category. Connection via M connector. safety PLC +V IQ 0 -pulse I Safety relay E.g. RT, RT9 S () S (+) S S Smile E can be connected to either or a safety relay. Two channel example with LED indication. Safety circuit category. Connection via M connector + termination connector. S S () S S S Smile E 7 8 safety PLC +V (+) S Safety relay E.g. RT, RT9 S S Smile E JST safety PLC +V IQ 0 -pulse I Safety relay E.g. RT, RT9 (+) S S () S S S Smile E JST 9 0 Smile E can be connected to either or a safety relay. Two channel serial connection example with LED indication. Safety circuit category. Connection via M connectors. Connection is made here without a termination device for Smile E (C), this unit is reconnected to the /safety relay via a separate cable. You can also use JST as a termination device after SmileE (C). safety PLC +V IQ 0 -pulse I +V IQ 0 -pulse I Safety relay E.g. RT, RT9 (+) S S () S S S (+) S S () S S S Smile E Smile E Smile E B B C C :7

Connection examples Smile Smile E and E can be connected to either or safety relay. Two channel example with LED indication. Safety circuit category. Connection via M connectors. Note that there is no termination connector as the Smile E (C) completes the circuit without the need for a termination connector (JST) or return cable. safety PLC +V IQ 0 -pulse I (+) S Safety relay E.g. RT, RT9 S () S S S Smile E Smile E Smile E E-Stop Button status LED Indication The table shows the LED indication status of the E-Stop B C B C buttons from the example shown in above example. R R R G G G R R D G G Rd = Smile E R D R G Rd B B = Smile E R D D G Rd B C = Smile E R = Released D R R Rd B B D = Depressed D R D Rd B B G = Green light from the top of the button D D R Rd B B Rd = Red light from the top of the button D D D Rd B B Termination B = Blank, no light device JST Smile 0E/E/E are like any other emergency stops when to the LED indication is not connected. This means that any suitable Safety PLC or safety relay can be used. If the LED indication is used, the voltage between Pin (+) and Pin (-) should be between 9. 8.8 VDC. The following examples show connections to Safety PLC and Safety relay. B C Single channel PLC connection Two channel Safety relay connection Output Output PLC Safety Relay Output Input Input Smile E Input Smile E Brown White Blue Black Grey Smile 0E Brown White Black Grey Smile 0EK The cable is connected to Smile 0E via the lid at the back.. Input. Input. 0 VDC (to be connected only if LED indication is required). Output. Output Brown White Blue Black Grey Smile E (R) Brown White Blue Black Grey The leads are connected to Smile 0EK via the lid at the back. No LED connection. Brown Input White Input Black Output Grey Output Smile E (R) Brown White Blue Black Grey. Input. Input. 0 VDC (to be connected only if LED indication is required). Output. Output. Input. Input. 0 VDC (to be connected only if LED indication is required). Output, feedback. Output, feedback. Output. Output. 0 VDC. Input, feedback. Input, feedback :8

Technical data Smile Manufacturer: rticle number/ ordering data: Smile 0E with m cable Smile 0EK with short connecting leads (No LED connection) Smile E with M male connector Smile E with male and female M connectors Smile ER Smile ER JST termination for Smile. Smile E S-i Note. There are versions for dynamic technology (with Tina). Impact resistance (half sinusoidal) Vibration resistance (sinusoidal) Climate resistance Damp heat, cyclical Damp heat, sustained Dry heat Cooling Salt mist B/Jokab Safety, Sweden TL000R000 TL000R000 TL000R0000 TL000R000 TL000R000 TL000R000 TL000R00 TL000R0000 max. 0 m/s, pulse width ms, -axis, as per EN IEC 008--7 max. 0 m/s at 0 Hz, 0 cycles, -axis, as per EN IEC 008-- 9 hours, + C / 97%, + C / 9 % relative humidity, as per EN IEC 008--0 days, +0 C / 9 % relative humidity, as per EN IEC 008--78 9 hours, +70 C, as per EN IEC 008-- 9 hours, -0 C, as per EN IEC 008-- 9 hours, + C in a chemical solution with NaCl as per EN IEC 008-- Level of safety: IEC/EN 08-...7 SIL PFH D :,0E-0 Colour: Yellow, red and black Weight: pprox. grams Size: Length: 8 mm + M contact(s) (. mm each) Width: 0 mm Height: mm Material: Polyamide P, Macromelt, Polybutylentere phthalate PBT, Polypropylene PP, UL 9 V0 mbient temperature: -0 C to + C (operation), -0 C to +70 C (stock) Protection class: IP Mounting: Two M recessed hexagon head screws, L mm. Hole cc: mm LED on E-Stop: Green: Safety device ok, Safety circuit closed Off: Safety circuit broken (When an E-Stop is depressed all following units in the circuit lose the LED function). Red: Safety device actuator depressed and Safety circuit broken. Input voltage (LED): 7-7 VDC ripple ±0% (LED supply voltage) Current consumption (LED): m E-Stop button ctuating force: ± N ctuator travel: pprox. mm to latch Material, contacts: Silver alloy gold plated Min current: 0 m 0 VDC/ 0 VC Max current: VDC Life, mechanical: > 0 000 operationer ccessories: Emergency stop button S D F,,mm TL000R0700 Emergency stop button E F T,,mm TL000R0800 Conformity: EN ISO 80, EN 00, EN 097-- & - Sign for emergency stop 7 8 9 0 :9

Emergency stop with indication Smile Tina pprovals: CERTIFIED BY pplication: To stop a machine or a process Features: Smile Tina - small and cost effective E-stop In order to fulfil the need for a small and easy to install E-stop, Smile has been developed. The size of the device makes it possible to be installed wherever you want. With M connections or cable and centralised mounting holes Smile is very easy to install, especially on aluminium extrusions. Smile is available for E-stops in both dynamic and static safety circuits i.e. for interfacing to Vital system/ safety PLC and Safety relays. Each version is available with either one or two M connections or cable. Two M connectors are used to enable the connection of E-stops in series, which is often used with dynamic safety circuits fulfilling safety category. In the top of the Smile Tina E-stop unit, LEDs show the actual status according to the dynamic system: Green = everything is OK, Red = E-stop activated. Flashing Red/Green = Stop activated from another preceding device. Smile is also available with black push button and used as a safety stop. See section on safety stops. The Smile Tina emergency stop is available in four versions:. Smile 0E Tina has a m cable connected via the base of the unit.. Smile E Tina has a five-pole M connector on the end of the unit for connecting the Jokab Safety cable.. Smile E Tina has two five-pole M connectors, one on each end of the unit for connecting the Jokab Safety cable.. Smile ER Tina has one -pole M connector at one end for connection of cable from Jokab Safety. Emergency push button up to cat. /PL e acc. to EN ISO 89- Light grids, emergency stop and Eden in the same safety loop together with Vital or gives cat. /PL e acc. to EN ISO 89- With LED indication on push button Robust Info-signal from each emergency stop Push button IP, housing IP7 vailable as safety stop (black push button) :0

Connection examples Smile Tina Smile 0E Tina can be connected to either a or Vital system. Safety circuit category with LED indication/information. The connection cable exits from underneath the unit. IQ0 Vital T R Smile 0E Tina Smile E Tina can be connected to either a or Vital system. Safety circuit category with LED indication/information. Connection via M connectors. The circuit below shows three Smile E Tina units connected in series via connection terminals in the electrical cabinet. Electrical cabinet IQ0 Vital T R Connection termination Smile E Tina Smile E Tina Smile E Tina B C 7 8 Smile E Tina can be connected to either a or Vital system. Safety circuit category with LED indication/information. Connection via M connectors. The circuit below shows three Smile E Tina units and one Eden connected in series via a Tina connection block. IQ0 Vital Tina T R Smile E Tina Smile E Tina Smile E Tina B C 9 0 Eden = dam & Eva :

Connection examples Smile Tina E-Stop Button status Information output signal B C B C R R R H H H R R D H H L R D R H L H R D D H L L D R R L H H D R D L H L D D R L L H D D D L L L The table shows the information output signal status from each of the Smile E Tina units in the previous connection examples. In the example showing connection with an Eden sensor, the Eden status information signal acts in the same way as the Smile Tina E units. The status information signal can be connected to e.g. PLC input. Note. The information signal must not be used as a safety signal. The signal should only be used to indicate the status of connected devices. = Smile E Tina B = Smile E Tina C = Smile E Tina R = Released Smile E can be connected to either a or Vital system. Safety circuit category with LED indication/information. Connection via M connectors. The last Smile E Tina unit feeds the dynamic signal back to the /Vital. D = Depressed H = High (i.e. supply voltage) L = Low (= 0 VDC) B C IQ0 Vital T R Smile E Tina Smile E Tina Smile E Tina E-Stop Button status LED Indication B C B C R R R G G G R R D G G Rd R D R G Rd F R D D G Rd Rd D R R Rd F F D R D Rd F Rd D D R Rd Rd F D D D Rd Rd Rd The table shows the LED indication status of the E-Stop buttons in the previous connection examples, where three Smile 0 E, Smile E or E Tina units are connected in series. = Smile 0// E Tina B = Smile 0// E Tina C = Smile 0// E Tina R = Released D = Depressed G = Green light from the top of the button Rd = Red light from the top of the button F = Flashes between green and red light Smile E can be connected to either a or Vital system. Safety circuit category with LED indication/information. Connection via M connectors. The circuit shows two Smile E Tina s, one Eden sensor and one Focus Light Curtain connected in series. Eden = dam & Eva Focus IQ0 Vital T R Smile E Tina Smile E Tina M- M- M-B Tina 0 Brown White Blue Black Grey + - Smile 0E Tina. Input voltage,7-7 VDC ripple+/- 0%. Dynamic input signal. 0 VDC. Dynamic output signal. Information output The connection cable is connected to the Smile 0E Tina unit via the back panel. Brown White Blue Black Grey + - Smile E Tina Brown White Blue Black Grey + - Smile E Tina + - Brown White Blue Black Grey. Input voltage,7-7 VDC ripple+/- 0%. Dynamic input signal. 0 VDC. Dynamic output signal. Information output. Input voltage,7-7 VDC ripple+/- 0%. Dynamic input signal. 0 VDC. Not used. Not used. Output voltage to next unit. Dynamic output signal (To next Smile or to or Vital system). 0 VDC. Not used. Information output :

Technical data Smile Tina Manufacturer: rticle number/ ordering data: Smile 0E Tina with m connection cable Smile E Tina with M male connector Smile E Tina with male and female M connectors Smile ER Tina Note. There are versions for use with relay technology (without Tina). Impact resistance (half sinusoidal) Vibration resistance (sinusoidal) Climate resistance Damp heat, cyclical Damp heat, sustained Dry heat Cooling Salt mist Level of safety: IEC/EN 08-...7 SIL PFH D : Colour: Weight: Size: Material: mbient temperature: B/Jokab Safety, Sweden TL0000R000 TL0000R0000 TL0000R000 TL0000R000 max. 0 m/s, pulse width ms, -axis, as per EN IEC 008--7 max. 0 m/s at 0 Hz, 0 cycles, -axis, as per EN IEC 008-- 9 hours, + C / 97%, + C / 9 % relative humidity, as per EN IEC 008--0 days, +0 C / 9 % relative humidity, as per EN IEC 008--78 9 hours, +70 C, as per EN IEC 008-- 9 hours, -0 C, as per EN IEC 008-- 9 hours, + C in a chemical solution with NaCl as per EN IEC 008--,E-09 Protection class: IP Mounting: Yellow, red and black pprox. grams Length: 8 mm + M contact(s) (.mm each) Width: 0 mm Height: mm Polyamid P, Macromelt, Polybutylenterephthalate PBT, Polypropylen PP, UL 9 V0-0 C to + C (operation) -0 C to +70 C (stock) Two M hexagon socket screws, L mm. Hole centres: mm LED on E-Stop: Time delay: Sign for emergency stop Green: Safety device OK, Safety circuit OK Flashing: Safety device OK, safety circuit broken. Red: Breaks in safety device and safety circuit :. (Two Smile units are equal to three Edens in time delay) Input voltage: 7-7 VDC ripple ±0% Current consumption: Current from information output: E-Stop button ctuating force: ctuator travel: Material, contacts: Life, mechanical: ccessories: Emergency stop sign S D F,.mm Emergency stop sign E F T,.mm 7 m (7m with max. current from information output) 0 m max ± N pprox. mm to latch Silver alloy gold plated > 0 000 operations TL000R0700 TL000R0800 Conformity: EN ISO 80, EN 00, EN 097-- & - 7 8 9 0 :

Emergency stop with indication Smile S-i pprovals: CERTIFIED BY pplication: To stop a machine or a process Safe input node in S-i systems Features: Smile E S-i is an emergency stop with a built-in dual channel safe S-i input node. The S-i bus and the safety around it is specified by the two organisations S-International ssociation and S-Interface Safety at Work, and is described in publications such as S-Interface The utomatic Solution. Smile E S-i is supplied with 0 V DC from the S-i bus. The recommended connection to the S-i bus is made via a flat cable terminal to M (see Figure), which makes it possible to quickly and easily connect the device to the yellow S-i cable. Smile S-i can also be connected directly to the S-i bus using only two conductors (pins and on the unit's M contact). Smile is also available with black push button and is used in this case as a safety stop. See section on safety stops. Emergency push button up to cat. /PL e acc. to EN ISO 89- Simple connection to S-i bus With LED indication on push button and S-i status indication Robust Push button IP, housing IP7 vailable as safety stop (black push button) :

Technical data Smile S-i Manufacturer: rticle number/ ordering data: Smile E S-i B/Jokab Safety, Sweden TL000R0000 S-i data S-i profile S-7.B.0 ddressing M-contact Node address on delivery 0 Response time across the S-i bus ms (+ response time for safety monitor) Pin configuration () S-i + () Not used () S-i () Not used () Not used Voltage supply Output voltage Total current consumption < 0 m 0 V DC from the S-i bus. Tolerance.. V DC. General Enclosure protection class IP mbient temperature - +0 C Dimensions x 0 x 8 (+, mm M contact) (H x B x D) Colour Base: Yellow Emergency stop button (Smile E S-i): Red Safe stop button (Smile S S-i): Black ctuating force ± N ctuating movement Ca mm till lås Mechanical life > 0 000 operationer PFH D,9x0-9 Safety/Harmonised standards IEC/EN 08-..7 SIL, PFDavr:,9x0 - EN 0 SIL EN ISO 89- Performance level PL e, Category, MTTF d : high EN 097-- & - For emergency stop buttons/ safety stop buttons EN ISO 80:008 For emergency stop buttons/ safety stop buttons Certification TÜV Nord Push button control panel LED in emergency stop button LED displays can be individually programmed in the PLC program as shown below. LED in pushbutton Indicator Description Red ON Output bit ON OFF Output bit OFF or Output bit & ON Green ON Output bit ON OFF Output bit OFF or Output bit & ON S-i LED and Fault LED in combination LED pair at the M contact. S-i (Green) Fault (Red) OFF OFF S-i voltage missing ON OFF Normal operation ON ON No data exchange with master Flash ON No data exchange due to address = 0 7 8 9 0 Smile xxxx-x with one S-i node for four pushbuttons. Smile Exxxx-x with one S-i safety node for e-stop and one S-i node for three pushbuttons. Smile EKxxxx-x with two safety nodes (e-stop and mode selector) and one S-i node for two pushbuttons. :

Safety stop Inca and Smile When should I use the safety stop? Safety stops are used to stop the operation of a machine in a safe manner. It must not be used as an emergency stop, but only as a stop for an individual hazardous motion. This is indicated by black push button. Likewise, an emergency stop push button with red push button must not be used as a safety stop. Inca for panel mounting The Inca series is available with black push button and is called Inca S/Inca S Tina. The safety stop is identical to the corresponding emergency stop apart from the black push button. For technical data see the Inca emergency stop. Smile with indication The Smile series is available with black push button and has a similar designation apart from an S in the name instead of E. The safety stops are identical to the corresponding emergency stops apart from the black push button. For technical data see the Smile emergency stop. rticle number TL000R000 TL000R000 Ordering data INC S INC S Tina rticle number Ordering data TL000R0900 Smile S TL000R000 Smile S TL000R00 Smile SR TL0000R000 Smile S Tina TL0000R000 Smile S Tina TL0000R0700 Smile SR Tina TL0000R0800 Smile SR Tina TL000R000 Smile S S-i :

Reset button Smile R When do I need reset push button? Smile R/B are reset Push buttons intended to reset safety circuits. Smile R has a connections for the NO-contact and for the LED in the PB. The reset LED is o be turned of after reset of the safety circuit. Smile RB is used together with our Safety Plc in order to reduce the numder of terminals, on terminal is used as both input for the reset as well as output for the LED. 7 Technical data Smile R Manufacturer rticle number/ ordering data Smile R Smile RB Colour Base Pushbutton Material Housing Pushbutton contact B/Jokab Safety, Sweden TL000R0000 TL000R000 yellow blue Polyprobylene PP u mbient temperature Humidity range Protection class Connectors Size Weight Mechanical life Switching reliability -...+ C to 8% (with no icing or condensation) IP -pole male M connector 8x0x (LxWxH) + mm for M connector (L) aprox. 0 g.000.000 operations at 0 m/ VDC 0 x 0 - at m/ VDC 8 9 0 Power Supply LED operating voltage LED current consumption Pushbutton operating voltage Pushbutton current consumption Pushbutton rated power VDC (maximum VDC) 0 m at VDC 0 m at VDC Min: V, max: V Min: M, max 00 m Max: 0 mw :7